Merck
Filter
Showing 31–51 of 51 results
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | MQuant® pH Indicator Strips Series |
| Price | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MQuant® Phosphate Test Strips Series |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model Series | MQuant® Total Hardness Test Strips |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NOVA30 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Wavelengths | 340, 445, 525, 550, 605, 690 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | −0.300 to 3.200 A |
| Light Source | Tungsten Halogen Lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Cuvette Format | 16 mm round tubes |
| Barcode Method Recognition | Yes |
| AQA Modes | 3 (including zero-point and turbidity correction) |
| Data Storage Capacity | Up to 500 results |
| Interface | RS232-C |
| Real-Time Clock | Integrated |
| Power Supply | 220 V, 50 Hz with optional rechargeable battery |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.8 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NOVA60A |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Total Phosphorus, Total Nitrogen, and over 50 additional water quality parameters |
| Wavelength Range | 340–820 nm (12 fixed wavelengths) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | –0.300 to 3.200 A |
| Cuvette Compatibility | 10 mm, 20 mm, 50 mm square cuvettes and 16 mm round tubes (auto-recognized) |
| Barcode Method Recognition | Yes |
| Light Source | Tungsten halogen lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Quality Control Modes | 3 AQA modes (including zero-point correction and turbidity compensation) |
| Internal Memory | Up to 1000 measurement results |
| User-Defined Methods | Up to 50 custom calibration curves (10 at fixed wavelengths) |
| Real-Time Clock | Yes |
| Interface | RS232C (for PC connection, printer output, and method updates) |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | –25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.3 kg |
| Battery Option | Rechargeable battery available for field use |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectroquant Multy |
| Price | Upon Request |
| Display | 6-digit LCD with backlight |
| Wavelengths | 430 nm, 530 nm, 560 nm, 580 nm, 610 nm, 660 nm (fixed LED sources) |
| Optical Technology | Dual-beam photometry with interference filter compensation |
| Temperature Compensation | 6-point automatic |
| Sample Holders | 16 mm and 24 mm round cuvettes (included) |
| Dimensions (instrument) | 265 × 195 × 70 mm |
| Dimensions (carrying case) | 440 × 370 × 140 mm |
| Interface | RS232 serial port |
| Power Supply | Rechargeable NiCd battery pack (7 cells) |
| Operating Conditions | 0–50 °C, <90% RH (non-condensing) |
| Data Storage | 1000 measurement records with timestamp, parameter ID, and user-defined sample ID |
| Keypad | Chemical-resistant capacitive touch keys |
| Self-Test | Automatic power-on diagnostic routine |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 180.1, and EN ISO 15704 for colorimetric water analysis |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Spectroquant TR 420 |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual heating blocks |
| Batch Capacity | 24 × 16 mm digestion tubes |
| Temperature Range | Ambient to 170 °C |
| Temperature Accuracy | ±1.0 °C |
| Display | LCD with real-time setpoint/actual temperature & time monitoring |
| Heating Status Indication | LED (flashing during ramp-up |
| Safety Features | Contact-protected heating surface |
| Preprogrammed Methods | 8 standard digestion protocols |
| Power Supply | 115–230 V, 50–60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | 3.6 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move |
| Instrument Type | Portable |
| Measurement Principle | Absorption Photometry (LED-based, Fixed-Wavelength) |
| Measured Parameters | Residual Chlorine, Chlorine Dioxide, and Other Water Quality Parameters (via Preloaded Methods) |
| Range | 0.02–6 mg/L |
| Accuracy | ±1 nm (wavelength), ±3% FS (absorbance, 20–25°C) |
| Repeatability | ≤3% RSD |
| Resolution | 0.01 A (absorbance), 1 mAbs (instrumental) |
| LOD | 0.0035 mg/L |
| Wavelength | 530 nm |
| Light Source | High-Stability LED |
| Optical Path | Fixed 10-mm Cuvette Chamber |
| Display | LCD with Backlight |
| Keyboard | Chemical-Resistant Membrane |
| Power | 4 × AAA batteries (up to 17 h operation or ~5,000 measurements) |
| Weight | 260 g |
| Dimensions (H × W × D) | 155 × 75 × 35 mm |
| Carry Case Dimensions | 340 × 270 × 80 mm |
| Ingress Protection | IP68 |
| Data Storage | 16 measurement results |
| Data Transfer | Optional Infrared Interface (Spectroquant® IR Adapter) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Pharo 100 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capability | Multi-Parameter (≥50 parameters) |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical System | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600) |
| Cuvette Compatibility | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Data Storage | 1000 test results + 4 MB for spectral/dynamic data (e.g., 100 scans, 400 kinetics curves) |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS232 |
| Compliance | DIN, US EPA certified methods |
| Power | 100–240 V~, 50–60 Hz |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm |
| Weight | ~3.7 kg (without battery) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzer |
| Model | Pharo 300 |
| Instrument Type | Benchtop UV-Vis Spectrophotometer for Water Analysis |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon Flash Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A), ±0.5 % (for 0.600 ≤ A ≤ 2.000 A), ±1.0 % (for A > 2.000 A) |
| Cuvette Compatibility | 16 mm round, and 10/20/50 mm square cuvettes with automatic recognition |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan (1 nm increment), Kinetic Assays |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Connectivity | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, US EPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Enclosure Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L × H × W) |
| Weight | 3.7 kg (without battery) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Pharo 300 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon Flash Lamp |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A) |
| Cuvette Types | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Scan Increment | 1 nm |
| Data Storage | 1000 measurement results + 4 MB for spectral/dynamic data (e.g., 100 scans or 400 kinetics curves) |
| Compliance | DIN, US EPA certified methods |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Pharo100 |
| Price | Upon Request |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A) |
| Cuvette Types | 16 mm round, and 10/20/50 mm square (auto-recognized) |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan, Kinetics |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, USEPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco Cl₂/O₃/pH/ClO₂/CyA |
| Instrument Type | Laboratory & Field-Portable Water Quality Analyzer |
| Optical System | Wavelength-Specific LED Light Source with Interference Filter |
| Measurement Wavelength | 528 nm |
| Measurement Time | 3–4 seconds per test |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per battery) |
| Auto Power-Off | Activated after ≈5 minutes of inactivity |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90 % RH (non-condensing) |
| Compliance | CE-marked per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Picco COD/CSB |
| Pricing | Available Upon Request |
| Optical System | LED Light Source with Interference Filter at 605 nm |
| Measurement Accuracy | ±3.5% |
| Measurement Time | 3–4 seconds |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90% RH (non-condensing) |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per set) |
| Auto-Off Delay | ~5 minutes after last keypress |
| Safety Certifications | CE compliant per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Sample Cell Format | 16 mm round glass cuvettes |
| Required Pre-treatment | Digestion using external COD digestion unit (e.g., Merck Spectroquant® Thermoreactor) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco F |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzers |
| Models | TR320, TR420, TR620 |
| Detection Parameters | COD, Total Phosphorus (TP), Total Nitrogen (TN) |
| Sample Capacity | TR320 – 12 × 16 mm tubes |
| TR420 & TR620 – 24 × 16 mm tubes (TR620 | two independent 12-position blocks) |
| Temperature Range | TR320 – 100 °C, 120 °C, 148 °C (fixed) |
| Temperature Uniformity | ±1.5 °C max deviation between center and peripheral wells |
| Heating Time Range | TR320 – preset only |
| Predefined Programs | 7 standard digestion protocols (e.g., 148 °C/20 min for COD, 120 °C/60 min for TP) |
| User-Defined Programs | TR420 & TR620 support up to 8 custom methods |
| Compliance Features | Optional external temperature probe for analytical quality assurance (AQA) |
| Power Supply | 115 V~ / 230 V~, 50/60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | TR320 – 2.85 kg |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Total Alkalinity Titration Test Kit |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | TR 320 |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual Independent Heating Blocks |
| Batch Capacity | 12 samples |
| Temperature Setpoints | 100 °C, 120 °C, 148 °C |
| Temperature Accuracy | ±1.0 °C |
| Digestion Tube Diameter | 16 mm |
| Display | LCD with Real-Time Setpoint & Actual Temperature/Time Monitoring |
| Safety Features | Touch-Safe Heating Surface, Integrated Protective Cover |
| Power Supply | 115–230 V, 50–60 Hz |
| Dimensions (H×W×L) | 180 × 256 × 307 mm |
| Weight | 2.85 kg |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA |
| Product Type | Epithelial Resistance & Voltage Measurement System |
| Model | Millicell® ERS-2 |
| Measurement Principle | AC-based impedance spectroscopy (12.5 Hz sinusoidal current) |
| Electrode Type | Dual Ag/AgCl miniaturized probe electrodes |
| Probe Tip Diameter | ≤1.0 mm |
| Voltage Range | ±100 mV |
| Resistance Range | 0–10,000 Ω |
| Resolution | 1 Ω (0–1,000 Ω), 10 Ω (1,000–10,000 Ω) |
| Accuracy | ±2% of reading |
| Power Supply | 9 V alkaline battery (included) |
| Compliance | Designed for GLP-compliant TEER monitoring in vitro |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA, Darmstadt, Germany |
| Product Line | Mobius® CellReady |
| Vessel Volume | 3 L (working volume) |
| Configuration | Benchtop Stirred-Tank Bioreactor |
| Sterility | Pre-sterilized, Gamma-Irradiated |
| Material | USP Class VI–compliant Polymeric Film (Multi-layer EVOH barrier) |
| Controller Compatibility | Compatible with standard Mobius® controllers (e.g., Mobius® Control Unit, or third-party PID-based bioreactor controllers via analog/digital I/O) |
| Regulatory Support | Designed for use in process development under GMP-aligned workflows |