Merck
Filter
Showing 1–30 of 57 results
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Erenna® |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | easyCyte 8 |
| Product Category | Flow Cytometer |
| Laser Configuration | Dual-laser (488 nm blue + 635 nm red) |
| Fluorescence Channels | 6 (Green, Yellow, Red1, Red2, NIR1, NIR2) + 2 Scatter (FSC, SSC) |
| Sample Format | 1.2 mL or 1.5 mL microtubes |
| Software Platform | guava InCyte v3.x |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA, Darmstadt, Germany |
| Product Type | Benchtop Flow Cytometer |
| Laser Configuration | 488 nm Blue Laser + 638 nm Red Laser |
| Fluorescence Channels | 6 (Green, Yellow, Red1, Red2, NIR1, NIR2) + 2 Scatter (FSC, SSC) |
| Detection Optics | High-Transmission Bandpass Filters (e.g., 525/30 nm, 583/26 nm, 692/46 nm, 661/19 nm, 785/70 nm ×2) |
| Sample Format | 96-Well Microplate (Standard ANSI/SLAS), 1.2–1.5 mL Tubes |
| Automation | Integrated 96-Well Plate Autoloader |
| Software | Guava InCyte v3.x (FDA 21 CFR Part 11–Ready, Audit Trail Enabled, GLP/GMP-Compatible Workflow Support) |
| Brand | Merck |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MAS-100 NT |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Rate Range | 1–2000 L/min |
| Flow Measurement Accuracy | ±2.5% at 100 L/min |
| Total Operating Time | Approx. 5.5 h on full battery charge |
| Storage Temperature | −10°C to +50°C |
| Operating Temperature | 0°C to +40°C |
| Operating Relative Humidity | ≤80% RH (up to +31°C), linearly decreasing to ≤50% RH at +40°C, non-condensing |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Calcium Ion Titration Test Kit |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CellStream |
| Product Type | Flow Cytometry Analyzer |
| Lasers | Up to 7 (configurable) |
| Detection Channels | 22 |
| Fluorescence Sensitivity (MESF) | FITC < 10, PE < 5 |
| Flow Rate | 3.66–14.64 µL/min |
| Fluorescence Detection Limit | 20,000 events/sec |
| Cell Analysis Throughput | FITC MESF < 10, PE MESF < 5 |
| Detector Technology | Time-Delay Integration CCD (TDI-CCD) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | guava easyCyte 6-2L |
| Product Type | Flow Cytometer |
| Sample Vial Format | 1.2 mL or 1.5 mL microtubes |
| Fluorescence Channels | Red2 (661/19 nm), Red1 (690/50 nm), Yellow (583/26 nm), Green (525/30 nm) |
| Excitation Lasers | 488 nm blue laser, 638 nm red laser |
| Parameters Measured | 6-parameter (4 fluorescence + 2 light scatter) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | guava easyCyte 6HT-2L |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Milli-Q Advantage A10 |
| Purified Water Grade | Type I (ASTM D1193-22) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| [Brand | Merck |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Ultra-Pure Water System |
| Model | Elix® Essential |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C (typical 10–15 MΩ·cm @ 25 °C) |
| Conductivity | <0.2 µS/cm @ 25 °C (typical 0.067–0.1 µS/cm @ 25 °C) |
| TOC | <30 ppb (typical) |
| Microbial Count | <10 CFU/mL (with optional UV lamp) |
| Endotoxin | <0.001 EU/mL (with terminal 0.22 µm filter) |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate | 3–15 L/h (selectable) |
| Operating Ambient | 5–35 °C, 20–80% RH |
| Power Supply | 100–230 V AC ±10%, 50–60 Hz |
| Feed Water Pressure | 0.5–6 bar] |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Milli-Q Integral |
| Pure Water Grade | Type II |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Microbial Count | < 0.1 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Pure Water Flow Rate | 3–15 L/h |
| Ultra-Pure Water Flow Rate | 2 L/min |
| Silicon Rejection Rate | >99.9% |
| TOC in Pure Water Output | <30 ppb |
| Brand | Merck |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IPAK Gard® |
| Pricing | Available Upon Request |
| Purified Water Grade | Type I (Ultra-Pure Water) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 5 ppb |
| Microbial Count / Endotoxins | < 0.001 EU/mL |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Milli-Q IQ 7000 |
| Pure Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 2 ppb (typical ≤ 5 ppb) |
| Microbial Count | < 0.001 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | Zero particles > 0.22 µm per 100 mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Milli-Q Reference |
| Price Range | USD 13,500 – 40,500 (est.) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 5 ppb (µg/L) |
| Microbial Count | < 0.1 CFU/mL |
| Endotoxins | < 0.001 EU/mL (pyrogen-free) |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | < 1 pg/mL (with BioPak) |
| DNase | < 5 pg/mL (with BioPak) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | IX7003 / IX7005 / IX7010 / IX7015 |
| Purified Water Grade | ASTM Type II |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <1 ppb |
| Total Organic Carbon (TOC) | ≤30 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Direct-Q3 |
| Pure Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Ultrapure Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | < 10 ppb (without UV), < 5 ppb (with optional 185/254 nm dual-wavelength UV lamp) |
| Endotoxins | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/mL |
| Particles (>0.22 µm) | < 1 particle/mL |
| Flow Rate (Ultrapure) | ≥ 0.5 L/min (up to 30 L/hr) |
| Flow Rate (Pure) | ≥ 3 L/hr |
| Internal Reservoir | 6 L (RO water) |
| Conductivity Sensor Electrode Constant | 0.01 cm⁻¹ |
| Temperature Compensation Accuracy | ±0.1 °C |
| Brand | Merck |
|---|---|
| Origin | France |
| Model | Direct-Q5 |
| Pure Water Grade | Type III (ASTM D1193-06) |
| Ultrapure Water Grade | Type I (ASTM D1193-06, ISO 3696 Class 1, CLSI EP21-A) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | < 5 ppb (with 185/254 nm UV lamp) |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.22 µm) | < 1/mL |
| Flow Rate (Ultrapure) | ≥ 0.5 L/min (up to 30 L/hr) |
| Flow Rate (Pure) | ≥ 5 L/hr |
| UV Lamp | Dual-wavelength 185/254 nm |
| Terminal Filtration Options | Millipak® Express 20 (0.22 µm), BioPak® UF (for endotoxin/RNase/DNase removal) |
| Reservoir Compatibility | Optional 30 L or 60 L integrated tank |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Elix Advantage |
| Price Range | USD 6,500 – 13,000 (est.) |
| Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Optional Tank Capacities | 30 L, 60 L, 100 L |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Elix Intelligent Pure Water Module |
| Price Range | USD 13,500 – 40,500 (est.) |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >10 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb (<10 ppb with optional UV-oxidation module) |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck Millipore (acquired Amnis) |
| Product Type | Imported Instrument |
| Model | FlowSight |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Merckoquant |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analytes | Ammonia-Nitrogen, Nitrate, Phosphate |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA |
| Product Category | Imported |
| Model | Mobius® |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MERCK |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Analytes | Cyanide, Arsenic, Heavy Metals (Cu, Ni, Cr⁶⁺, Zn, Fe, Mn, Pb, Cd, etc.) |
| Detection Principle | Colorimetric Semi-Quantitative Visual Comparison |
| Compliance | ASTM D3370, ISO 9562, ISO 10530, EN ISO 11732, US EPA Method 9010B (Cyanide), US EPA Method 7196A (Hexavalent Chromium), DIN 38405-27 |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Category | Imported |
| Model | Muse |
| Product Type | Flow Cytometry-Based Cell Analyzer |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | RiOs Smart Pure Water Module |
| Price Range | USD 13,500 – 40,500 (based on configuration) |
| Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >10 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb (optional <10 ppb with UV oxidation module) |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Simplicity |
| Quotation Range | USD 6,800 – 13,600 (est.) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| Flow Rate | >0.5 L/min |
| Integrated Reservoir | 2 L |
| UV Option | Dual-wavelength (185 nm + 254 nm) lamp available for TOC reduction |
| Final Filtration | Optional BioPak ultrafiltration cartridge (sterile, pyrogen-free, nuclease-free output) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MNKSAG0609 |
| Pricing | Upon Request |
| Diameter | 47 mm |
| Pore Size | 0.8 µm |
| Pack Size | 100 per Box |
| Compliance | SH/T 0175–2004, ASTM D2274 |
| Brand | Merck |
|---|---|
| Origin | USA |
| Product Line | MQuant® Ammonia-N Test Strips |
| Format | Dip-and-read colorimetric test strips |
| Measurement Range | 0.1–5.0 mg/L NH₃-N (typical for MQuant® Ammonia-N, per Merck technical documentation) |
| Detection Principle | Indophenol blue method (NH₃ + phenol + hypochlorite → blue chromophore) |
| Compliance | Designed to support ISO 7150-1, ASTM D1426, and EPA Method 350.1 screening protocols |
| Package Options | 50 or 100 tests per vial |
| Shelf Life | 24 months from manufacture when stored at 2–8 °C in sealed foil pouch |
| Brand | Merck |
|---|---|
| Origin | USA |
| Product Type | Imported Reagent Test Strips |
| Model Series | MQuant® Hydrogen Peroxide Test Strips |
| Measurement Range | 0.1–100 mg/L (ppm) H₂O₂ |
| Detection Method | Colorimetric (Peroxidase-catalyzed oxidation of chromogen) |
| Shelf Life | 24 months from manufacture (unopened, stored at 2–8 °C) |
| Format | Individual foil-wrapped strips (100 strips per pack) |
| Compliance | Designed in accordance with ISO 8694:1986 (Water quality — Determination of hydrogen peroxide — Spectrophotometric method) and compatible with GLP/GMP documentation workflows |