| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | 850-011-100706 |
| Material | Perfluoroalkoxy (PFA) |
| Configuration | Dual-channel nebulizer spray chamber assembly with detachable O-ring sealed end cap, integrated make-up gas port, 6 mm OD nebulizer inlet, PFA drain connector kit, quartz torch, PFA injection tube, support stand, and pre-cleaned components (pre-rinsed in high-purity HNO₃/HF) |
| Compliance | Compatible with Thermo Scientific Element 2 HR-ICP-MS and Neptune MC-ICP-MS platforms |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | C-Flow |
| Flow Rates | 50 µL/min and 200 µL/min |
| Material | Perfluoroalkoxy (PFA) |
| Compliance | Compatible with Scott-type spray chambers (35 mm), O-ring-free design |
| Certification | Manufactured under ISO 9001-certified processes, compliant with ASTM D5673 and USP <232>/<233> for trace metal analysis |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Product Type | Microwave Digestion Vessels |
| Material | High-Purity PFA (Perfluoroalkoxy) |
| Compatibility | Fully compatible with all microwave digestion systems (e.g., CEM MARS, Anton Paar Multiwave, Milestone ETHOS) |
| Thermal Stability | Continuous use up to 260 °C, short-term peak tolerance ≥300 °C |
| Pressure Rating | Designed for sealed-vessel high-pressure microwave digestion (up to 100 bar typical operational limit) |
| Surface Finish | Electro-polished inner surface, ultra-low extractables (<1 pg/mL metal leaching per ASTM D5127) |
| Regulatory Compliance | Meets ASTM E2918 (Standard Practice for Handling and Storage of Trace Metal Samples), USP <232>/<233> elemental impurities requirements, and ISO/IEC 17025 traceability standards |
| Packaging | Individually clean-room packaged (Class 100 / ISO 5), certified for trace-metal analysis |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000 |
| Instrument Type | Sub-boiling Distiller |
| Cooling Method | Passive (Air) Cooling |
| Distillation Endpoint Control | Automatic |
| Power Supply | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (excluding funnel) |
| Capacity | 125 mL – 1 L |
| Wetted Materials | Molded PFA Only |
| Compliance | ASTM D511, ISO 17294-2, USP <645>, FDA 21 CFR Part 11 (software-enabled audit trail optional) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000 |
| Power Input | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (excl. funnel) |
| Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA |
| Cooling | Air-cooled (no water required) |
| Drainage | Integrated gravity-fed drain channel |
| Temperature Control | Adjustable, sub-boiling range |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DST-1000 |
| Price | Upon Request |
| Power Supply | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg (10.15 lbs) |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (10.15″ × 10.15″ × 16.92″) |
| H with funnel | 51 cm (20.08″) |
| Capacity | 125 mL – 1 L |
| Material Construction | High-Purity PFA (Perfluoroalkoxy alkane) |
| Cooling | Air-cooled, no water required |
| Drainage | Integrated gravity-fed waste channel |
| Temperature Control | Adjustable analog thermostat |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000A |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Resistive Heating (Corrosion-Resistant Heater Sleeve) |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | 1000 mL/24 h |
| Warm-up Time | 30 min |
| Endpoint Control | Manual |
| Heating Element | Corrosion-Resistant PFA-Encapsulated Heater Sleeve |
| Power Input | 70 W |
| Voltage Options | 100/115/230 VAC ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 20 × 20 × 43 cm (excl. funnel) |
| Weight | 4.6 kg |
| Maximum Capacity | 1 L |
| Material of Wetted Parts | Injection-Molded PFA |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000B |
| Power Input | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg (10.15 lbs) |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (10.15" × 10.15" × 16.92") |
| Height with Funnel | 51 cm (20.08") |
| Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA Fluoropolymer |
| Cooling | Air-cooled (no water required) |
| Temperature Control | Adjustable, sub-boiling range |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000N |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Silicone Rubber Heating Mantle |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | Up to 500 mL per 12 hours |
| Warm-up Time | 30 minutes |
| Endpoint Control | Temperature-based Setpoint Activation |
| Heating Element | Silicone Rubber Heating Mantle |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-4000 |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Resistive Heating (Corrosion-Resistant Heater Sleeve) |
| Cooling Method | Passive Air Cooling |
| Endpoint Control | Automatic |
| Heating Element | PFA-Encapsulated Resistive Heater in Corrosion-Resistant Protective Sleeve |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (excluding funnel) |
| Weight | 4.6 kg |
| Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA (Perfluoroalkoxy Alkane) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-4000S |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Encircling Electric Heating Mantle |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | 500 mL/24 h |
| Warm-up Time | 60 min |
| Endpoint Control | Max. 4 L total distillate volume |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg (10.15 lbs) |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (10.15″ × 10.15″ × 16.92″) |
| Reservoir Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST4000 |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Encircling Electric Heating Mantle |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | 1000 mL / 12 h |
| Ramp Time to Operating Temperature | 60 min |
| Endpoint Control | Temperature-Based Setpoint Activation |
| Heating Element | Integrated Electric Heating Mantle |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Power Consumption | 125 W |
| Weight | 7.25 kg |
| Capacity Range | 500 mL – 4 L |
| Wetted Materials | Molded PFA Only |
| Footprint | < 0.093 m² (< 1 ft²) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | HPX-100 |
| Heating Power | 230 V AC |
| Max Temperature | 240 °C |
| Temperature Uniformity | ±2 °C @ 150 °C |
| Top Plate Dimensions | 47.5 cm × 40.4 cm × 14.8 cm |
| Heating Zone Dimensions | 292 mm × 212 mm |
| Display | Digital LED |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | HPX-100-1 |
| Voltage | 230 V |
| Max Temperature | 240 °C |
| Temperature Uniformity | ±2 °C @ 150 °C |
| Plate Dimensions | 27.2 cm × 40.4 cm × 14.8 cm |
| Heating Zone | 292 mm × 212 mm |
| Display | Digital LED |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | HPX-200 |
| Heating Power | 230 V AC |
| Max Temperature | 240 °C |
| Temperature Uniformity | ±2 °C at 150 °C |
| Plate Dimensions | 47.5 cm × 40.4 cm × 14.8 cm |
| Heating Zone Dimensions | 415 mm × 212 mm |
| Display | Digital LED |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | HPX-200-1 |
| Heating Power | 230 V AC |
| Controller | Integrated digital controller |
| Max Operating Temperature | 240 °C |
| Temperature Uniformity | ±2 °C at 150 °C |
| Plate Dimensions | 47.5 cm × 40.4 cm × 14.8 cm |
| Heating Zone Dimensions | 415 mm × 212 mm |
| Display | LED digital display |
| Surface Material | Semiconductor-grade graphite core with full PFA (perfluoroalkoxy alkane) fluoropolymer coating |
| Edge Protection | Molded PTFE thermal guard ring |
| Certifications | TÜV-certified, CE-compliant, RoHS-conformant |
| Application Class | Trace-metal-clean sample digestion and evaporation |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Authorization Status | Authorized Distributor |
| Origin Category | Imported |
| Model No. | 850-011-100787 |
| Pricing | Upon Request |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Microcolumns |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Material | PFA (Perfluoroalkoxy Alkane) |
| Customization Available | Yes (Storage Volume & Capillary Length) |
| Compatibility | PTFE-compatible and PFA-compatible sample matrices |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | PFA Vial |
| Pricing | Upon Request |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | Compatible with Agilent 7500 Series |
| Nebulizer Type | PFA Concentric (C-Flow) & Cross-Flow (X-Flow) |
| Nominal Uptake Rate | 200 µL/min (C-Flow), 50 µL/min (C-Flow Low-Flow Option) |
| Material | 100% Perfluoroalkoxy (PFA), O-Ring-Free Construction |
| Torch Interface | Push-Fit Connector for Agilent ICP-MS Torch |
| Compliance | Fully Compatible with ASTM D5673, ISO/IEC 17025 Trace Metal Analysis Protocols, USP <232>/<233> Elemental Impurities Testing |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model No. | 850-011-100635 |
| Pricing | Upon Request |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PFA |
| Pricing | Upon Request |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Product Line | PFA Labware |
| Compliance | ASTM F2164, USP Class VI, ISO 10993-5 |
| Material Certification | Trace-Metal-Free (≤10 fg/g for As, Cd, Cr, Cu, Fe, Ni, Pb, Zn, Co), Halogen-Free |
| Thermal Stability | –270 °C to +260 °C |
| Density | 2.13–2.167 g/cm³ |
| Melt Processing Range | 350–400 °C |
| Elongation at Break | 100–300% |
| Dielectric Constant (1 MHz) | 2.02–2.10 |
| Coefficient of Friction (dynamic) | ≤0.05 |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | PFA Bottle |
| Material | Perfluoroalkoxy (PFA) Copolymer |
| Density | 2.13–2.167 g/cm³ |
| Thermal Stability | –270 °C to +260 °C |
| Chemical Resistance | Resistant to HF, aqua regia, concentrated HNO₃/H₂SO₄/HCl, organic solvents, and caustics |
| Compliance | ASTM D4894, ISO 1043-1, USP Class VI biocompatibility certified |
| Manufacturing Standard | Cleanroom-assembled, trace-metal-free (sub-ppt leachables), Class 100/ISO 5 environment |