SCIEX
Filter
Showing 1–30 of 66 results
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole / Linear Ion Trap Hybrid System |
| Model | 3200 Q-TRAP |
| Mass Range | 5–2,000 m/z (typical operational range) |
| Sensitivity | Sub-pg on-column for small molecules (e.g., <10 fg injected for reserpine S/N ≥ 50:1 in MRM) |
| Resolution | Unit mass resolution in both Q1 and Q3 |
| Accurate Mass Capability | Not applicable (non-high-resolution system) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 3200 MD |
| Configuration | Integrated Shimadzu Prominence LC-20A HPLC System (LC-20AD pump, SIL-20A HT autosampler, CTO-20A column oven, DGU-20A3 degasser, CBM-20A system controller) |
| Ion Source | Turbo V™ ESI/APCI (standard), optional DuoSpray™, PhotoSpray™, NanoSpray™ |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with triple quadrupole mass filtering and collision-induced dissociation (CID) in LINAC™ collision cell |
| Vacuum System | Dual-stage rotary vane roughing pump |
| Software | Analyst® 1.6.2 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Warranty | 90-day comprehensive hardware and software functionality warranty |
| Brand | SCIEX |
|---|---|
| Origin | Canada |
| Model | API 4000 |
| Instrument Type | Triple Quadrupole / Linear Ion Trap Hybrid Mass Spectrometer |
| Usage Duration | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 5000 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Ionization Modes | ESI & APCI |
| Software | Analyst® 1.6.3 |
| Vacuum System | Integrated Foreline Pump |
| Warranty | 6 months |
| Operational Age | 4–5 years |
| Compliance | Designed for GLP/GMP environments |
| Sample Throughput | High-throughput quantitative analysis platform |
| Brand | SCIEX |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | QTRAP 2000 |
| Price Range | USD 14,000 – 43,000 (FOB) |
| Product Category | Chromatography & Mass Spectrometry |
| Operational Age | 5–7 years |
| Warranty | 6 months limited hardware warranty |
| Configuration | Integrated with NanoSpray Ion Source, Video Monitoring Camera, and LC Packings Nano-HPLC System |
| Condition | Refurbished, Fully Functionally Tested |
| Compliance | Meets original factory specifications per SCIEX Service Bulletin SB-2000-08 |
| Brand | SCIEX |
|---|---|
| Origin | Canada |
| Model | QTRAP 3200 |
| Configuration | LC-MS/MS System with Integrated Linear Ion Trap |
| Condition | Factory-Refurbished & Performance-Validated |
| Warranty | 90-Day Comprehensive Hardware Warranty |
| Regulatory Readiness | Compliant with GLP/GMP data integrity expectations |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP 4500 |
| Instrument Type | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Year of Manufacture | 2016 (Demo Unit) |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Included LC System | Agilent 1290 UPLC (G1379B degasser, G4220A binary pump, G7167A multisampler, G1316C column oven) |
| Software Suite | Analyst v1.7, MultiQuant v3.0.3, PeakView v2.2 |
| Vacuum System | Integrated turbomolecular pump |
| Detection Mode | AcQuRate pulse-counting detector with analog fallback |
| Scan Speed | Up to 20,000 amu/sec (linear ion trap) |
| Polarity Switching Time | ≤50 ms |
| Mass Range | m/z 5–2000 |
| Ion Guide | QJet RF-only ion funnel |
| Collision Cell | Curved linear accelerator (LINAC) high-pressure collision cell |
| Ionization Compatibility | ESI, APCI, NanoSpray III, DuoSpray, PhotoSpray, LDTD, Triversa Nanomate |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP 5500, LC-20AD XR, SIL-20AC XR, CTO-20AC, DGU-20A3R, CBM-20A |
| Mass Range | Up to 1250 Da |
| Ion Sources | Turbo V™ ESI/APCI, DuoSpray™, NanoSpray III™, SelexION™ |
| Scan Modes | MRM, MS, MS/MS, MS³, PI, NL, EMS, EPI, ER, MRM³, TripleTrap™ |
| Detector | AcQuRate™ Pulse-Counting Detector |
| Usage Duration | 4 years |
| Warranty | 6 months |
| Compliance | FDA 21 CFR Part 11–ready software architecture, GLP/GMP-supportive audit trail capabilities |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Triple Quad 5500 |
| Instrument Type | Tandem Quadrupole (QqQ) LC-MS/MS |
| Ionization Sources | Turbo V, DuoSpray, PhotoSpray |
| Key Technology | eQ Electronics (50 ms polarity switching) |
| Software | Analyst® 1.7 or later |
| Compliance | Designed for GLP/GMP environments |
| Dimensions | 114 cm × 81 cm × 76 cm (W × D × H) |
| Weight | ~350 kg |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | AB SCIEX 5500 QTRAP |
| Instrument Type | Triple Quadrupole (QqQ) with Linear Ion Trap Capability |
| Mass Range | 5–1250 m/z |
| Sensitivity | 50 fg reserpine (ESI positive mode) |
| Resolution | 0.7 amu |
| Scan Speed | ≥12,000 amu/s |
| Mass Stability | ≤±0.1 Da/24 h |
| Polarity Switching Time | ≤50 ms |
| Max LC Pressure | 15,000 psi |
| Column Temperature Range | 5–65 °C |
| Signal-to-Noise Ratio (S/N) | >500:1 |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF 5600 |
| Configuration | LC-coupled Time-of-Flight Mass Spectrometer with Integrated Eksigent nanoLC System |
| Warranty | 90-day comprehensive hardware & software coverage |
| Calibration Status | Factory-verified mass accuracy (<1 ppm error over 24 h, EasyMass™), resolution validated at m/z 100 (25,000 FWHM) and m/z 950 (40,000 FWHM) |
| Scan Speed | Up to 100 Hz (100 spectra/s) |
| Dynamic Range | >4 orders of magnitude (linear) |
| Mass Accuracy | <1 ppm RMS (external calibration, 24 h stability) |
| Sensitivity | Sub-femtomole LOD for peptide standards under standard LC-MS/MS conditions |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX 7500+ System |
| Instrument Type | Triple Quadrupole (Tandem Quadrupole, QqQ) |
| Application Scope | Universal LC-MS/MS Analysis |
| MRM Transition Rate | 800 transitions/sec |
| Vacuum System Compatibility | Dry Pump Compatible |
| Regulatory Alignment | Designed for GLP/GMP-compliant laboratories |
| Software Platform | SCIEX OS |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | AB API 4000 |
| Instrument Type | Triple Quadrupole (QqQ) with Linear Accelerator (LINAC) Collision Cell |
| Mass Range | 10–3000 Da |
| Sensitivity | S/N ≥ 100:1 for 1 pg on-column reserpine (ESI+) |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Ionization Sources | TurboIonSpray® and APCI® (plug-and-play interchangeable probes) |
| Vacuum System | Dual-stage air-cooled turbomolecular pumps |
| Dimensions (H×D×L) | 52 × 50 × 130 cm |
| Operating Environment | 15–30 °C, 208–240 V AC, High-Purity Nitrogen & Zero-Air |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (for reserpine, ESI+) |
| Resolution | Full Width at Half Maximum (FWHM) 0.5–0.7 m/z |
| Mass Accuracy | ±0.1 Da (internal calibration) |
| Configuration | Used / Refurbished System with HPLC Integration Capability |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | AB-4000 |
| Instrument Type | Triple Quadrupole (QqQ) |
| Mass Range | 5–2,000 m/z |
| Sensitivity | <10 fg on-column for reserpine (ESI+, 400 µL/min) |
| Resolution | Unit mass resolution (±0.13 u at full width at half maximum) |
| Accurate Mass Capability | ±0.13 u (calibrated, external standard) |
| Ionization Sources | Turbo V™ ESI/APCI dual-mode source with rapid switchable probe |
| Collision Cell | Linear Accelerator (LINAC™) collision cell |
| Detector | Digital Pulse Detection System with >5-decade dynamic range |
| Software | Analyst® 1.7.2 or later (21 CFR Part 11 compliant) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | AB5500 |
| Instrument Age | 10 years |
| Category | Used Liquid Chromatography–Tandem Mass Spectrometer (LC-MS/MS) |
| Compliance Context | Designed for GLP/GMP-regulated environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 2000 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Configuration | LC-MS/MS System |
| Ionization Sources | TurboIonSpray® (ESI) and Heated Nebulizer (APCI) |
| Flow Rate Range (ESI) | 2–1000 µL/min |
| Flow Rate Range (APCI) | 0.2–2.0 mL/min |
| Collision Cell Technology | LINAC™ Linear Accelerator |
| Detection Mode | Pulse-counting Electron Multiplier |
| Dynamic Range | 1–4 × 10⁶ cps |
| Vacuum System | Air-cooled Differential Turbomolecular Pumps |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, Single-phase |
| Required Gases | High-purity Nitrogen, Zero-air (oil-free, clean compressed air) |
| Dimensions (H×D×L) | 60.5 × 50 × 105 cm |
| Service History | Refurbished & Fully Tested |
| Operational Age | ~4 years |
| Warranty | 6 months limited hardware warranty |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 3000 |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | 10–3000 Da |
| Sensitivity | S/N ≥ 100:1 for 1 pg on-column reserpine (ESI+) |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Ion Sources | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle-filtered compressed air) |
| Vacuum System | Varian DS602 dual-stage rotary vane pump with oil mist filter |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 3000 |
| Instrument Type | Triple Quadrupole LC-MS/MS System |
| Usage Duration | 4–5 years |
| Warranty | 6 months |
| Vacuum System | Dual-stage Turbo-V 551 Navigator molecular pump (Agilent) |
| Ionization Sources | TurboIonSpray® and APCI |
| Flow Rate Range (ESI) | 2–1000 µL/min |
| Flow Rate Range (APCI) | 0.2–2.0 mL/min |
| Detection | Pulse-counting detector with polarity switching |
| Dynamic Range | 1–4 × 10⁶ cps |
| Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | API 4000 Q-Trap |
| Instrument Type | Triple Quadrupole Linear Ion Trap Hybrid |
| Mass Range | 5–2000 m/z |
| Sensitivity | <10 fg on-column for SRM (e.g., reserpine) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Accurate Mass Capability | Not applicable (nominal mass instrument) |
| Ion Source Options | TurboIonSpray® and APCI® with plug-and-play interchangeability |
| Collision Cell | LINAC™ high-efficiency linear accelerator collision cell |
| Detection System | Pulse-counting electron multiplier |
| Dynamic Range | 1–4 × 10⁶ cps |
| Vacuum System | Dual-stage turbomolecular pumps with air-cooled design |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle-free compressed air) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 4000 |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Ionization Modes | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Software Platform | Analyst® 1.6.3 or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Mass Range | m/z 5–3,000 (typical operational range) |
| Sensitivity | Sub-femtogram on-column detection for selected pharmaceutical compounds (e.g., ≤5 fg on-column for midazolam in MRM mode) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum, FWHM) |
| Mass Accuracy | ±0.2 Da (calibrated) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | API 4000 |
| Application Domain | Pharmaceutical Development, Clinical Research, Environmental & Food Safety Analysis |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Compliance | FDA 21 CFR Part 11 (via Analyst® software), GLP/GMP-ready |
| Detection Modes | ESI and APCI |
| Maximum LC Flow Rate | 3 mL/min |
| Collision Cell Technology | LINAC® High-Pressure Collision Cell |
| Ion Source | Turbo V™ Dual-Gas Heated Electrospray and Atmospheric Pressure Chemical Ionization Source |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API4000 Q-Trap |
| Instrument Type | Hybrid Triple Quadrupole/Linear Ion Trap Mass Spectrometer |
| Mass Range | 5–2,000 m/z |
| Sensitivity | <10 fg on-column for reserpine (MRM, ESI+) |
| Resolution | Unit mass resolution in Q1 and Q3 |
| Mass Accuracy | ±0.2 Da (calibrated) |
| Scan Speed | Up to 6,000 Da/sec |
| Dynamic Range | 4 orders of magnitude (1–4 × 10⁶ cps) |
| Vacuum System | Dual-stage air-cooled turbomolecular pumps |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle- and hydrocarbon-free compressed air) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API4000 |
| Instrument Type | Triple Quadrupole Liquid Chromatography-Tandem Mass Spectrometer |
| Application Domain | Quantitative Bioanalysis, DMPK, Clinical Research, Impurity & Metabolite Identification |
| Condition | Factory-Refurbished |
| Operational Age | 6–8 years |
| Warranty | 12 months comprehensive coverage |
| Regulatory Compliance Support | FDA 21 CFR Part 11–ready software configuration, GLP/GMP-aligned audit trail capability |
| Ionization Modes | TurboIonSpray®, APCI, optional DuoSpray™ and PhotoSpray™ sources |
| Brand | SCIEX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC-Compatible Vertical Tower Autosampler |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Volume | 250 µL |
| Minimum Injection Volume | 0.1 µL |
| Loop Volume | 100 µL |
| Positioning Accuracy | < 0.3 mm |
| Motion Axes | XYZ Three-Dimensional |
| Needle Wash Mode | Internal and External Wall Rinse |
| Repeat Injection Capability | Unlimited Cycles |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | BioPhase 8800 + NFD |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Detector | Native Fluorescence Detector (NFD) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| CE Modes Supported | CE-SDS, cIEF, CZE |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Linear Dynamic Range | >4 decades |
| Correlation Coefficient (R²) | ≥0.995 |
| Sensitivity | Sub-μg/mL for native protein detection |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX BioPhase™ 8800 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Channel Capacity | 8 parallel capillaries |
| Detection Modes | UV-Vis and Laser-Induced Fluorescence (LIF) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| Application Focus | Biopharmaceutical characterization (mAb, bispecifics, ADCs, gene therapy vectors) |
| Sensitivity | ≤1 µg/mL (CE-SDS), linear dynamic range >4 orders of magnitude (R² > 0.995) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | C100 HT |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis |
| Voltage Range | 1–25 kV |
| Detection Modes | UV and Laser-Induced Fluorescence (LIF) |
| Injection Method | Pressure-driven |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-based Temperature Control |
| Operating Mode | Constant Current |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | CESI 8000 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Type | Organic Analysis |
| Detector Options | UV and Laser-Induced Fluorescence (LIF) |
| Operating Mode | Current-Controlled |
| Injection Method | Electrokinetic |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-Cooled Temperature Control |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Tandem Quadrupole Mass Spectrometer |
| Configuration | Acoustic Droplet Ejection (ADE) Coupled to Triple Quadrupole MS |
| Regulatory Design | Designed for GLP/GMP-Compliant Quantitative Bioanalysis |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail and Electronic Signatures |
| Throughput | Up to 3 samples per second |
| Workflow Integration | Direct ADE-to-MS Interface Without Chromatographic Separation |
| Application Focus | High-Throughput Quantitative Screening in Drug Discovery, ADME, and Clinical Biomarker Analysis |