Sea-Bird Scientific
Filter
Showing all 11 results
| Brand | Sea-Bird Scientific |
|---|---|
| Model | HydroCAT |
| Measurement Parameters | Conductivity, Temperature, Pressure (Depth), Optical Dissolved Oxygen |
| Depth Rating | 350 m |
| Sampling Interval | 2.3–3.2 sec/sample |
| Clock Stability | ±5 sec/month |
| Power Supply (Optional) | 9–24 VDC |
| Compliance | EPA-Approved Anti-Fouling System |
| Calibration | Factory-calibrated to 2–4× specification accuracy in temperature-controlled environment |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Model | Cycle PO₄ |
| Detection Principle | Colorimetric Microfluidic Analysis (EPA Method 365.3) |
| Detection Limit | ≤75 nM PO₄-P (3σ in 18 MΩ·cm water) |
| Quantitation Limit | ≤0.25 µM PO₄-P (10σ) |
| Typical Range | 0–10 µM PO₄-P (0–0.3 mg/L as PO₄-P) |
| Optical Path Length | 5 cm |
| LED Wavelength | 870 nm |
| Linearity | ≥95% R² |
| Operating Depth | Up to 200 m |
| Temperature Range | 1–35 °C |
| Power Input | 10–18 VDC |
| Average Current Draw | 125 mA |
| Sampling Frequency | Up to 2 samples/hour |
| Data Storage | 1 GB internal |
| Output Interfaces | RS-232, SDI-12 |
| Filter | Dual-stage (copper mesh + 10 µm stainless steel) |
| Calibration | Onboard NIST-traceable peak calibration with user-configurable schedule |
| Reagent Cartridge Life | >1000 analyses per cartridge (including QA/QC calibrations) |
| Housing Dimensions | 56 cm (H incl. handle) × 18 cm (W) × — cm (D) |
| Air Weight | 6.8 kg (with reagents) |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Hydrocat |
| Price | Upon Request |
| Temperature Range | −5 to 45 °C |
| Temp Resolution | 0.0001 °C |
| Temp Accuracy | ±0.002 °C |
| Conductivity Range | 0–70 mS/cm |
| Cond Resolution | 0.0001 mS/cm |
| Cond Accuracy | ±0.003 mS/cm |
| Pressure Range | 0–350 m (depth equivalent) |
| Pressure Resolution | 0.002% FS |
| Pressure Accuracy | ±0.1% FS |
| Dissolved Oxygen Range | 0–120% saturation |
| DO Resolution | 0.007 mg/L |
| DO Accuracy | ±0.1 mg/L or ±2% (whichever is greater) |
| Housing | Engineering-grade polymer |
| Weight (air/water) | 3.4 kg / 1.5 kg |
| Sampling Interval | 2.3–3.2 s per profile |
| Power Supply | 9–24 V DC, 0.25 A |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Hydro-T |
| Measurement Range | –5 to 45 °C |
| Initial Accuracy | ±0.002 °C |
| Typical Stability | <0.002 °C/year |
| Resolution | 0.0001 °C |
| Clock Accuracy | ±5 seconds/month |
| Battery | Saft LS14500 3.6 V Li-SOCl₂ (hazard-free) |
| Sampling Capacity | 15.9M samples |
| Max Deployment Duration | Up to 2 years (dependent on sampling interval) |
| Housing Material | Engineering-grade polymer |
| Pressure Rating | 1500 m (4900 ft) |
| Weight | 0.2 kg (air), 0.05 kg (water) |
| Calibration | 11-point NIST-traceable calibration in SBE’s ISO/IEC 17025-accredited thermal calibration bath |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | USA |
| Manufacturer | WET Labs (designed and manufactured) |
| Model | ECO Series |
| Instrument Type | Submersible Optical Sensor Platform |
| Deployment Modes | Profiling, Moored, Buoy-Mounted, Handheld (via optional interface) |
| Compliance | IP68 rated, ASTM D3921-22 (for turbidity), ISO 10264-2 (for chlorophyll-a fluorescence calibration traceability), GLP-compliant data logging |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Model | ECO Series |
| Optical Excitation/Emission Wavelengths | Chl-a 470/695 nm, CDOM 370/460 nm, Fluorescein 470/530 nm, Rhodamine WT 540/570 nm, Phycoerythrin 540/570 nm, Phycocyanin 630/680 nm |
| Backscatter Wavelengths | 470, 532, 650 nm |
| Chl-a Sensitivity | 0.02 µg/L |
| Chl-a Range | 0–125 µg/L |
| Turbidity Accuracy | ±0.003 NTU (0–10 NTU) to ±0.25 NTU (0–1000 NTU) |
| Backscatter Sensitivity | 0.003 m⁻¹ |
| Backscatter Range | ~0.0024–5 m⁻¹ |
| Digital Resolution | 12–14 bit |
| RS-232 Baud Rate | 19200 |
| Analog Output | 0–5 V |
| Operating Depth | 600 m |
| Temperature Range | 0–30 °C |
| Power Supply | 7–15 VDC |
| Typical Current Draw | 50–60 mA |
| Sleep Current | 140 µA |
| Housing Material | Acetal Copolymer |
| Connector | MCBH6MP |
| Optional Features | Anti-fouling Copper Brush, Internal Battery, Onboard Memory (up to 108,000 samples), Integrated T/P Sensor |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LOBO |
| Pricing | Upon Request |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SUNA V2 |
| Optical Path Length Options | 5 mm or 10 mm |
| Detection Range | 0.5–4000 µM NO₃⁻ (0.007–56 mg/L N) |
| Accuracy | ±2 µM (10 mm) or ±4 µM (5 mm), or ±10% of reading, whichever is greater |
| Short-Term Precision (3σ) | 0.3 µM (T-S-corrected freshwater/seawater) |
| Long-Term Drift | ≤0.3 µM/h (T-S-corrected) |
| Turbidity Tolerance | 625 NTU (10 mm), 1250 NTU (5 mm) |
| Wavelength Range | 190–370 nm |
| Lamp Lifetime | 900 h |
| Operating Voltage | 8–18 VDC (8–15 VDC with biofouling brush) |
| Power Consumption | 7.5 W at 12 VDC (0.625 A) |
| Housing Material | Polyoxymethylene (POM) and Titanium Alloy |
| Depth Rating | 500 m (standard) |
| Weight | 2.5 kg (standard) |
| Calibration Options | Freshwater and Seawater Modes |
| Data Interface | USB (PC/Mac compatible) |
| Software | SUNACom v3.x (Windows/macOS) |
| Brand | Sea-Bird Scientific |
|---|---|
| Manufacturer | Satlantic (Canada) |
| Model | SUNA V2 |
| Detection Principle | In-Situ Ultraviolet Spectroscopy (ISUS) |
| Measurement Target | Nitrate-N (NO₃⁻) |
| Form Factor | Submersible, Online-Ready |
| Path Length Options | 5 mm or 10 mm |
| Detection Range | 0.5–4000 µM (0.007–56 mg/L as N) |
| Accuracy | ±2 µM (10 mm) / ±4 µM (5 mm) or ±10% |
| Short-Term Precision (3σ) | 0.3 µM (freshwater/seawater T-S corrected) |
| Long-Term Drift | ≤0.3 µM/h (T-S corrected) |
| Turbidity Tolerance | 625 NTU (10 mm), 1250 NTU (5 mm) |
| Wavelength Range | 190–370 nm |
| Lamp Lifetime | 900 h |
| Operating Voltage | 8–18 VDC (8–15 VDC with biowiper) |
| Power Consumption | 7.5 W (0.625 A @ 12 V) |
| Housing Material | Titanium / Acetal |
| Maximum Depth Rating | 500 m (100 m with biowiper) |
| Weight | 2.5 kg (3.1 kg with biowiper) |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | USA |
| Model | WQM |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | CTD (Conductivity, Temperature, Depth), Dissolved Oxygen (DO), Fluorescence (Chlorophyll-a), Turbidity (FLNTU) |
| Optional Parameters | CDOM, PAR, Phycocyanin, Phycoerythrin, pH |
| Conductivity Range | 0–9 S/m |
| Conductivity Accuracy | ±0.003 mS/cm |
| Conductivity Resolution | 0.0005 S/m |
| Temperature Range | −5 to 35 °C |
| Temperature Accuracy | ±0.002 °C |
| Temperature Resolution | 0.001 °C |
| Depth Range | 0–100 m or 0–200 m |
| Depth Accuracy | ±0.1% FS |
| DO Range | 0–120% saturation |
| DO Accuracy | ±2% saturation |
| DO Resolution | ±0.035% saturation |
| Chlorophyll Fluorescence Range | 0–30 µg/L |
| Fluorescence Accuracy | ±0.2% FS |
| Excitation/Emission | 470/695 nm |
| Turbidity Range | 0–25 NTU |
| Turbidity Accuracy | ±0.1 FS NTU |
| Detection Wavelength | 700 nm |
| Biofouling Mitigation | Pump-controlled flow, Copper anti-fouling panel, Light-shielded sample chamber, Rotating copper brush for optical surface cleaning, EPA-certified conductive cell anti-fouling ring, Bleach Injection System (BLIS) for DO and CTD channel protection |
| Brand | Sea-Bird Scientific |
|---|---|
| Manufacturer Origin | USA |
| Model | WQMX |
| Sensor Integration | CTD + FLNTU + DO + CDOM + Optional PAR/Phycocyanin/Phycoerythrin/pH |
| Depth Rating | 200 m |
| Power Input | 9–16 V DC |
| Communication | RS-232 |
| Sampling Rate | 1 Hz |
| Weight (air/water) | 6.25 kg / 1.7 kg |
| Biofouling Resistance | 3–6 months continuous deployment |
| Compliance | ASTM D888, ISO 5814, USP <643>, EPA Method 4500-O, GLP/GMP-ready data logging |
