SIELINS
Filter
Showing 31–37 of 37 results
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-802 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% FS |
| Repeatability | ≤2% FS |
| Response Time | ≤90 s |
| Long-term Stability | ≤2% FS/7 days |
| Measured Gases | CO, CO₂, H₂, O₂ |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-900 |
| Output | 4–20 mA analog signal per gas component |
| Alarm Output | Dry contact (NO/NC) for concentration threshold violation |
| Communication Interface | RS-485 (Modbus RTU) |
| Application Domain | Microbial fermentation off-gas monitoring (O₂, CO₂, exhaust airflow) |
| Compliance Context | Designed for integration into GMP-compliant biomanufacturing environments with audit-ready data logging capability |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | XLZ-901 |
| Pricing | Upon Request |
| Brand | SIELINS |
|---|---|
| Model | XLZ-902 |
| Origin | Beijing, China |
| Instrument Type | Flue Gas CEMS |
| Measurement Parameters | SO₂, NOₓ (as HOx), CO, CO₂ |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time | ≤ 200 s |
| Drift (24 h) | ≤ ±2% FS |
| Compliance | Designed for EPA Method 6C, 7E, 10, and ISO 15848-1 / EN 15267-3 referenced performance criteria |
| Brand | SIELINS |
|---|---|
| Model | XLZ-903 |
| Origin | Beijing, China |
| Instrument Type | Online CEMS |
| Measured Gases | SO₂, NOₓ, CO, CO₂, CH₄, NH₃, O₂ (configurable multi-component) |
| Measurement Range (min) | 0–50 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.1 ppm |
| Response Time | ≤25 s |
| Zero Drift | ±5% FS / 24 h |
| Span Drift | ±1% FS / 24 h |
| Linearity Error | ±2% FS |
| Compliance | Designed for EN 15267-3, EN 14181, and GB/T 16157–2018 referenced operation |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-940 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Portable Multi-Gas Flue Gas Analyzer |
| Accuracy | ≤ ±5% FS (SO₂, CO, NO, NO₂, CO₂) |
| Repeatability | ≤ 1% RSD |
| Response Time | < 3 s (T₉₀) |
| Stability | Long-term baseline drift < 2% FS/week |
| Measured Gases | O₂, SO₂, CO, NO, NO₂, CO₂ (calculated), flue gas temperature, ambient temperature, differential pressure |
| Sensor Configuration | Interchangeable electrochemical sensors (1–3 toxic gases selectable) |
| Operating Temperature | 0–50 °C |
| Battery Life | Up to 8 h continuous operation (rechargeable Li-ion) |
| Data Storage | 150 measurement sets with timestamp, location tag (optional), and calculated parameters |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | SIELINS-904 |
| Power Supply | AC 220 V ±10%, 50 Hz ±1% |
| Total Power Consumption | 2000 VA |
| Probe Power | 800 VA |
| � | �热管线供电: 1500 VA |
| Compressed Air Requirement | 0.6 MPa, oil-free & dry |
| Ambient Temperature Range | −10–50 °C |
| Relative Humidity | <80% RH |
| Output Signal | Isolated 4–20 mA DC |
| Alarm Output | Dry contact (NO/NC configurable) |
| Sample Gas | Wet, dusty process gas containing CO |
| Primary Analyte | Carbon Monoxide (CO) |
| Compliance | Designed for industrial process monitoring per IEC 61511 functional safety principles (non-SIL certified), compatible with DCS/PLC integration under ISO 50001 energy management contexts |