Spectro Scientific
Filter
Showing 1–30 of 74 results
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Type | Portable Mid-IR ATR Analyzer |
| Model | InfraCal 2 ATR-B |
| Detection Range | 0–100% biodiesel in diesel |
| Analysis Time | <30 s |
| Repeatability | ±0.2% (0–30%), ±1.0% (30–100%) |
| Compliant With | ASTM D7371, EN 14078 |
| Power | Rechargeable Li-ion battery (6+ hrs operation), 18 V DC input |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Wavelength | 5.7 µm (1745 cm⁻¹) |
| Interface | USB, RS-232 |
| Data Storage | Internal, password-protected, with operator/location/timestamp metadata |
| Display | Touchscreen LCD |
| Language Support | English, Spanish, French, Arabic |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-B |
| Measurement Principle | Attenuated Total Reflectance (ATR) Mid-Infrared Spectroscopy |
| Compliant Standards | ASTM D7371, EN 14078 |
| Detection Range | 0–100% biodiesel in diesel |
| Repeatability | ±0.2% (0–30%), ±1.0% (30–100%) |
| Analysis Time | <30 seconds |
| Power Supply | Rechargeable Li-ion battery (18 V DC, 3.3 A), >6 h operation |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Interface | Touchscreen display, USB, RS-232 |
| Data Storage | Internal memory with user, location, date/time stamping |
| Language Support | English, Spanish, French, Arabic |
| Calibration Options | Pre-loaded ATR-B curve (405-2041-24), optional multi-point calibration kits (e.g., 403-1024) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniLab EL |
| Application | Elemental Analysis of Lubricating Oils |
| Instrument Type | Benchtop/Field-Deployable Laboratory Analyzer |
| Compliance | Designed for ASTM D6595, ASTM D5185, ISO 8217, SAE J183, MIL-STD-3007 |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | CoolCheck 2 |
| Spectral Range | 200–1100 nm |
| Detection Time | 45 seconds per sample |
| Sample Volume | 15 mL |
| Light Sources | Dual xenon lamps (UV-Vis: 200–750 nm |
| NIR | 750–1100 nm) |
| Calibration | Multi-parameter calibration using three certified reference standards |
| Reagents/Solvents Required | None |
| Power Supply | Integrated rechargeable lithium-ion battery |
| Compliance | Designed for field-deployable, GLP-aligned operation in maintenance environments |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM 6000 |
| Type | Portable Instrument |
| Detection Principle | Surface Acoustic Wave (SAW) Sensor Technology |
| Measurement Range | 0.2–15% fuel dilution (v/v) |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 seconds per sample |
| Sample Volume | <1 mL |
| Power Source | Rechargeable lithium-ion battery |
| Data Storage | Up to 3 calibration curves |
| Display | Color touchscreen interface |
| Compliance | Designed for ASTM D7943-22 and ISO 4406-aligned maintenance practices |
| Software Guidance | Multilingual audio-assisted operation (including English voice prompts) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FDM 6000 |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FDM 6000 |
| Instrument Type | Portable Analyzer |
| Detection Parameter | Fuel Dilution in Engine Oil |
| Measurement Principle | Surface Acoustic Wave (SAW) Sensor Analysis of Head-Space Vapor |
| Detection Range | 0.2–15% v/v Fuel Dilution |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 seconds per sample |
| Sample Volume Required | <1 mL |
| Power Source | Rechargeable Lithium-Ion Battery |
| Data Storage | Up to 3 Calibration Curves |
| Interface | Color Touchscreen with Audio Guidance (Multilingual, including English) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FDM 6000 Series |
| Product Type | Portable Instrument |
| Detection Parameter | Fuel Dilution in Engine Oil |
| Detection Principle | Surface Acoustic Wave (SAW) Sensor + Headspace Vapor Analysis per Henry’s Law |
| Detection Range | 0.2–15% v/v |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 s |
| Sample Volume | <1 mL |
| Power Supply | Rechargeable Li-ion Battery |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −30–85 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Weight | >3 kg |
| Dimensions | 17 × 20 × 13 cm |
| Environmental Rating | IP34, NEMA Enclosure |
| Shock & Vibration Compliance | MIL-STD-810G |
| Electrical Safety Certifications | FCC Class B, CE |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM Vial Kit (Qty 50) |
| Package | 50 vials per kit |
| Part Number | 346162035 |
| Application | Fuel dilution analysis in lubricating oil samples |
| Compliance | Designed for use with ASTM D3524, D7897, and ISO 3104-compliant instrumentation |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Product Type | Imported |
| Model | FDM Vial Kit (Qty 50) |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FerroCheck 2000 |
| Price | Upon Request |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −30–85 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Weight | >3 kg |
| Dimensions | 17 cm × 20 cm × 13 cm |
| Shock & Vibration Certification | MIL-STD-810G |
| Electrical Safety | FCC Class B, CE |
| Environmental Rating | NEMA 3R, IP34 |
| Sample Type | In-service lubricating oils and hydraulic fluids |
| Measurement Principle | Magnetic susceptibility-based ferrous particle quantification |
| Response Time | ≤30 seconds per sample |
| Detectable Ferrous Particle Size Range | ~1 µm to >1 mm |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Detection Principle | Magnetic Susceptibility-Based Quantitative Ferrous Particle Measurement |
| Measurement Range | 0–10,000 ppm |
| Repeatability | <5 ppm |
| Particle Size Sensitivity | Nanoscale to Millimeter-Scale Ferromagnetic Particles |
| Analysis Time | <30 seconds per sample |
| Power Supply | Rechargeable Lithium-Ion Battery |
| Data Storage | Internal Non-Volatile Memory with USB Export Capability |
| Sample Requirement | No Pre-treatment or Organic Solvents Required |
| Compliance | Designed for ASTM D7684 (Standard Test Method for Quantitative Measurement of Wear Debris in Used Lubricants by Ferrography), ISO 4406, and GLP/GMP-Ready Data Traceability |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Compliance | ASTM D8120 |
| Detection Principle | Magnetic Susceptibility-Based Impedance Measurement |
| Sample Volume | 1.5 mL (oil), 0.75 mL (grease) |
| Analysis Time | ≤30 s |
| Detection Limit | <3 ppm Fe |
| Repeatability | ±2% RSD |
| Power | Rechargeable Li-ion battery (4 h runtime) |
| Data Output | CSV, AMS OilView-compatible |
| Calibration | Pre-loaded with certified calibration standards |
| Temperature Compensation | Automatic real-time coil current balancing |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58 |
| Product Type | Portable Instrument |
| Detection Capabilities | Elemental Analysis (XRF), Particle Counting, Kinematic Viscosity at 40 °C, FTIR-based Oxidation, Nitration, Soot, Water, TAN/TBN, Fuel & Glycol Contamination |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 487.68 × 386.08 × 228.6 mm (L × W × H) |
| Compliance | ASTM D6595, D7690, D7883, D7621, D7943, ISO 11171, ISO 4406, ISO 21468, ISO 21469, USP <1058>, FDA 21 CFR Part 11 (audit trail enabled in software) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58 |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 32 × 24 × 18 cm (L×W×H) |
| Weight | 6.8 kg |
| Analytical Methods | XRF Elemental Analysis, Differential Pressure Particle Counting (FPQ), Gravity Capillary Viscometry at 40 °C, FTIR Spectroscopy |
| Sample Volume | 3–5 mL per test |
| Test Time | <10 minutes per full suite |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 5.0 |
| Compliance | ASTM D6595 (XRF), ISO 4406 / ISO 11500 (particle counting), ASTM D445 (viscosity), ASTM E2412 / D7414 (FTIR oil analysis), GLP-compliant audit trail |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | FieldLab 58 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Product Type | Portable Instrument |
| Detection Principle | Direct Reading Infrared (DIR) Spectroscopy |
| Compliance | ASTM D7889, ASTM E2412, ASTM D4739, ASTM D664, ASTM E1655 |
| Key Parameters | TAN (mg KOH/g), TBN (mg KOH/g), Oxidation (Abs/0.1 mm), Nitration (Abs/mm²), Sulfation (Abs/mm²), Water (ppm), Glycol (%), Soot (%), FAME (%), Residual Carbon, Additive Depletion, Fuel Dilution, Oil Mismatch Index, FFA (%), Total Glycerin, Antioxidant Content (%) |
| Sample Volume | 1–2 drops |
| Measurement Time | ~60 seconds |
| Power | Rechargeable Li-ion battery (≥6 h operation) |
| Dimensions | 240 × 140 × 70 mm |
| Weight | 1.4 kg |
| Software | FluidScan Manager (PC-based, with trend analysis, asset management, automated reporting, audit trail, and data synchronization) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Instrument Type | Portable |
| Wavelength Range | 900–4000 cm⁻¹ |
| Measurement Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Sample Method | Direct Drop-on-Cell Dispersive Analysis |
| Software | Fluid Manager™ |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Application Domain | Industrial Lubrication Monitoring in Petrochemical, Power Generation, and Heavy Machinery Sectors |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Instrument Type | Portable Infrared Spectrometer |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Detection Targets | Water, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Contamination Index |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference oils |
| Lubricant Compatibility | Mineral & synthetic engine oils, gear oils, turbine oils, hydraulic fluids, transmission fluids, greases, biodiesel, and fuel blends |
| Cleaning Method | Solvent-free |
| Measurement Principle | Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluidScan 1000 Series |
| Instrument Type | Portable Analyzer |
| Measurement Parameters | Water Content, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Overall Oil Health Index |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference spectra (mineral & synthetic oils, greases, biodiesel, fuels) |
| Cleaning Method | Solvent-free |
| Detection Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Portability | Handheld, battery-operated, field-deployable |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluidScan |
| Product Type | Portable Instrument |
| Detection Parameters | Contaminants, Oxidation, Acid Number (AN), Base Number (BN), Water Content (Free & Dissolved), Fluid Identity |
| Compliance | ASTM D7889, JOAP Standards |
| Measurement Principle | Mid-Infrared (MIR) Absorption Spectroscopy |
| Sample Volume | 1 Drop (~50 µL) |
| Analysis Time | ≤ 60 Seconds |
| Onboard Database | > 800 Lubricant & Grease Reference Spectra |
| Calibration | Factory-Calibrated with Industry-Validated Algorithms |
| Reporting | Automated PDF Report Generation |
| Software Integration | FluidScan Manager (Windows-based Database & Trending Software) |
| Regulatory Support | Audit Trail, User Access Control, Data Export for GLP/GMP Environments |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-E |
| Portability | Portable |
| Compliance | ASTM D4815 |
| Detection Range | 0–20% and 70–98% ethanol in gasoline |
| Repeatability | ±0.2% (0–20%), ±1.0% (70–98%) |
| Analysis Time | <30 seconds |
| Wavelength | 9.6 µm (1045 cm⁻¹) |
| Power | 18 V DC, 3.3 A |
| Battery Life | >12 hours (rechargeable Li-ion) |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Interface | USB, RS-232 |
| Data Storage | Internal, password-protected |
| Display | Touchscreen LCD |
| Language Support | English, Spanish, French, Arabic |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-SP |
| Detection Limit (Water) | 0.3 ppm |
| Detection Limit (Soil) | 3 ppm |
| Wavelength | 3.4 μm (2930 cm⁻¹) |
| Power | 18 V DC, 3.3 A |
| Weight | 2.6 kg (net), 3.2 kg (with Li-ion battery) |
| Dimensions | 17 cm × 19.8 cm × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Analysis Time | 10–15 min (including extraction) |
| Repeatability | ±0.2 ppm |
| Communication Interface | USB |
| Compliance | EPA Method 1664, EPA Method 1164, ISO 9377-2 |
| Solvents | Hexane, Pentane, Cyclohexane, Vertrel MCA |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 |
| Detection Principle | Fixed-Filter Infrared Absorption (Near-IR) |
| Measurement Time | ≤10 s per sample |
| Sample Throughput | Continuous, sequential analysis |
| Power Supply | Rechargeable Li-ion battery (≥6 h operation) |
| Weight | <2.0 kg |
| Display | Touchscreen interface |
| Data Storage | Internal non-volatile memory with user, location, date/time stamps |
| Data Export | USB 2.0 port and removable USB flash drive support |
| Language Options | English, Spanish, French, Arabic |
| Calibration Security | Password-protected calibration curves and data management |
| Regulatory Alignment | Designed to support ASTM D7371 (Standard Test Method for Determination of Biodiesel (Fatty Acid Methyl Esters) in Diesel Fuel Oil by Mid Infrared Spectroscopy), ASTM D5798 (Ethanol in Gasoline), and EPA Method IO-3.2 compliance workflows |
| Software Compatibility | Standalone operation |
| Maintenance Requirements | No consumables beyond standard solvent wipes |
| Brand | Spectro Scientific |
|---|---|
| Model | InfraCal 2 |
| Origin | USA |
| Detection Principle | Infrared Absorption (C–H Stretch Band at ~2960 cm⁻¹) |
| Compliance | ASTM D7066 (Transmission Method), EPA Method 1664 (Reflectance Mode Equivalent) |
| Power | Rechargeable Lithium-ion Battery |
| Interface | Touchscreen Display |
| Calibration | Multi-curve Internal Library |
| Data Management | Onboard Storage & USB Export |
| Security | Password-Protected User Settings & Calibration Curves |
| Alarm | Configurable Threshold Alerts |
| Environmental Rating | Industrial-Grade Enclosure for Workshop & Cleanroom-Adjacent Use |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption Spectrophotometry (Fixed-Wavelength at 3.4 µm) |
| Measurement Range | 0.1–5000 ppm |
| Detection Limit | 0.1 ppm |
| Accuracy | < ±1% |
| Resolution | 0.1 ppm |
| Optical Bandpass | 3.4 µm filter with ±10 cm⁻¹ wavenumber tolerance |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Weight | 2.6 kg (net), 3.2 kg (with Li-ion battery) |
| Display | 640 × 480 color touchscreen |
| Power Supply | AC/DC adapter (110–220 V, 50–60 Hz) or 18 V DC / 3.3 Ah rechargeable Li-ion battery (≥16 h operation) |
| Operating Environment | 5–40 °C, <90% RH (non-condensing) |
| Connectivity | USB, RS232 |
| Compliance | ASTM D7066 (transmission mode), EPA Method 1664 (reflectance mode) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 Series |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption (Transmittance/Reflectance) |
| Compliance | ASTM D7066 (Transmittance Method), EPA Method 1664 (Reflectance Method) |
| Power Source | Rechargeable Lithium Battery |
| Calibration | Multi-curve Internal Calibration |
| Data Handling | Onboard Storage & USB/Bluetooth Export |
| Security | Password-Protected User Settings & Calibration Curves |
| Alarm | Configurable Threshold Alerts |
| Environmental Rating | Ruggedized for Field Use |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 TOG/TPH |
| Instrument Type | Portable |
| Compliance | ASTM D7066, EPA Method 413.2 & 418.1, Equivalent to EPA 1664 & ISO 9377-2 |
| Measurement Principle | Fixed-Filter Infrared Absorption at 3.4 µm C–H Stretch Band |
| Detection Range | Sub-ppm to % w/w (oil-in-water, TPH in soil, FOG in wastewater) |
| Data Storage | Internal memory for ≥1,000 test records |
| Interface | USB 2.0 for data export |
| Calibration | Multi-point calibration curves with user-defined curve management |
| Security | Password-protected settings and calibration access |
| Environmental Rating | IP65-rated enclosure |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 |
| Product Type | Laboratory Instrument |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range (undiluted) | 15–320 cSt |
| Detection of Water Droplets & Air Bubbles | Yes |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Optional Modules | Ferrous Particle Monitoring (ppm + size distribution ≥25 µm), Morphological Imaging & Neural Network-Based Classification (≥20 µm), Kinematic & Dynamic Viscosity Measurement at 40 °C, Automated Sample Processor (ASP) for 24 samples |