Teledyne Princeton Instruments
Filter
Showing all 13 results
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Acton LS 785 |
| Focal Length | 85 mm |
| Aperture Ratio | f/2.0 |
| Spectral Resolution | 5 cm⁻¹ (with 25 µm fiber) |
| Linear Dispersion | 6.13 nm/mm @ 900 nm |
| Grating | 1200 g/mm, gold-coated |
| Wavelength Range | 750–1100 nm (tunable via micrometer-driven grating stage) |
| Optical Design | Prism-based, AR-coated fused silica prism + optimized f/2 imaging optics |
| Detector Compatibility | Fully compatible with Teledyne Princeton Instruments PIXIS and PyLoN deep-depletion CCD cameras |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | UK |
| Model | Modulab XM PhotoEchem |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | XF-1024F, XF-1024B, XF-2048F, XF-2048B |
| Pixel Size | 13 × 13 µm (XF-1024 series), 13.5 × 13.5 µm (XF-2048 series) |
| X-ray Energy Range | <3 keV to >20 keV |
| Readout Speeds | 100 kHz and 2 MHz |
| ADC Resolution | 16-bit |
| Interface | High-speed USB 2.0 |
| Sensor Architecture | Front-illuminated (FI) or back-illuminated (BI) scientific CCD |
| Quantum Efficiency | Up to 97% at 550 nm (BI), 32% at 550 nm (FI) |
| Cooling | Thermoelectric (TE) with hot-spot suppression |
| Optical Coupling | Vacuum-integrated fiber-optic taper |
| Software Platform | LightField (64-bit), PICAM API |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | PIXIS-XO-100B, PIXIS-XO-100BR, PIXIS-XO-400B, PIXIS-XO-400BR, PIXIS-XO-1024B, PIXIS-XO-1024BR, PIXIS-XO-1300B, PIXIS-XO-2KB, PIXIS-XO-2048B |
| Pixel Sizes | 13 × 13 µm, 13.5 × 13.5 µm, 20 × 20 µm |
| Detection Range | <30 eV to ~20 keV |
| Cooling | Thermoelectric (–70 °C to –90 °C) |
| Readout Interface | High-speed USB 2.0 |
| ADC Resolution | 16-bit |
| Readout Speed | Up to 2 MHz |
| Sensor Architecture | Back-illuminated, deep-depletion CCD options available |
| Vacuum Interface | Rotatable ConFlat (CF) flange |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | KURO 1200B / KURO 2048B |
| Pixel Size | 11.0 × 11.0 µm |
| Quantum Efficiency | >95% (peak) |
| Read Noise | 1.3 e⁻ rms (median) |
| Full-Well Capacity | 80,000 e⁻ |
| Dynamic Range | 61,500:1 (95 dB) |
| Frame Rate | 82 fps @ 1200 × 1200 (12-bit), 41 fps @ 1200 × 1200 (16-bit) |
| Fill Factor | 100% |
| Spectral Optimization | UV–NIR (180–1100 nm) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | NIRvana: LN / NIRvana: 640 / NIRvana: 640ST |
| Sensor Format | 640 × 512 InGaAs FPA |
| Pixel Size | 20 × 20 µm |
| Spectral Range | 0.9–1.7 µm (NIRvana: 640 & 640ST), 0.9–1.55 µm (NIRvana: LN) |
| Peak Quantum Efficiency | up to 85% (0.95–1.5 µm) |
| Operating Temperature | –190 °C (LN), –85 °C (TE-cooled), –65 °C (ST) |
| Frame Rate | up to 110 fps |
| Interface | GigE Vision compliant |
| Bit Depth | 16-bit digitization |
| Readout Modes | 2 MHz / 5 MHz / 10 MHz |
| Software Platform | LightField 64-bit |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP audit trail capable, ASTM E1317-22 compatible for spectral radiometric calibration |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | 512×512, 1024×1024, 1600×200, 1600×400 |
| Pixel Sizes | 13×13 µm, 13.5×13.5 µm, 20×20 µm, 24×24 µm |
| Sensor Architecture | Back-Illuminated EMCCD with eXcelon3 anti-fringing technology |
| Quantum Efficiency | Up to 95% at 650 nm |
| Cooling | Deep thermoelectric cooling (≤ –90 °C sensor operating temperature) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | 512BX3, 1024BX3, 1600 eXcelon3 |
| Pixel Size | 13 × 13 µm, 16 × 16 µm |
| Spectral Range | 180–1100 nm |
| Peak Quantum Efficiency | >95% |
| Cooling | −70°C vacuum-sealed thermo-electric |
| Readout Speed | Up to 34 fps full-frame |
| Interface | GigE Vision compliant |
| Data Depth | True 16-bit |
| Calibration | Built-in OptiCAL reference source with automated gain/offset correction |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Range | PyLoN 100B/BR, 400B/BR, 2KB, 2KBUV, 2KF, 256E/BR |
| Pixel Size | 20 × 20 µm, 13.5 × 13.5 µm, 26 × 26 µm |
| Cooling | Liquid Nitrogen to –120 °C |
| Dark Current | ≤1 e⁻/pixel/hour |
| Spectral Response | 200–1100 nm |
| Readout Speed | 50 kHz – 4 MHz |
| Interface | Gigabit Ethernet |
| Software | LightField (64-bit) |
| QE Peak | Up to 98% (eXcelon-enhanced deep-depletion back-illuminated) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | 1024-1.7, 1024-2.2 |
| Pixel Size | 25 µm (W) × 500 µm (H), 25 µm (W) × 250 µm (H) |
| Spectral Range | 800–1700 nm (1024-1.7), 1000–2200 nm (1024-2.2) |
| Digitization | 16-bit ADC |
| Max Acquisition Rate | 6600 spectra/sec |
| Cooling | Liquid nitrogen (77 K) |
| QE Peak | 88% (1024-1.7), 70% (1024-2.2) |
| Dark Current | <0.1 e⁻/pixel/sec @ 77 K |
| Read Noise | <15 e⁻ RMS (typ.) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Quad-RO 4320 |
| Pixel Size | 24 × 24 µm |
| Imaging Array | 2084 × 2084 pixels |
| Energy Range | ~3 keV to >20 keV |
| Quantum Efficiency (at 550 nm) | >70% |
| Readout Interface | IEEE 1394a (FireWire) |
| ADC Resolution | 16-bit |
| Maximum Readout Speed | 4 MHz (4 outputs × 1 MHz each) |
| Cooling | Thermoelectric (hot-stage) |
| Scintillator Compatibility | Interchangeable Gd₂O₂S:Tb screens optimized for 8, 12, and 17 keV |
| Software Platform | LightField (64-bit) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | SOPHIA 2048B / SOPHIA 2048BX |
| Pixel Size | 15 × 15 µm |
| Sensor Architecture | Back-Illuminated CCD |
| Peak Quantum Efficiency | >95% (eXcelon-enhanced for 2048BX) |
| Cooling | ArcTec™ Thermoelectric Vacuum-Sealed Cryogenic System (down to –90 °C) |
| Readout Noise | ~4 e⁻ rms |
| Readout Speed | Up to 16 MHz (quad-port) |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic extension (up to 50 m) |
| Software Platform | LightField® 64-bit with IntelliCal™, PICAM API, LabVIEW/MATLAB/EPICS compatibility |
| Vacuum Warranty | Lifetime hermetic seal |
| Spectral Compatibility | UV-VIS-NIR (enhanced with eXcelon anti-fringing technology) |
| Mechanical Interface | Standard Nikon F-mount or spectrograph-compatible flange (ConFlat for SOPHIA-XO variant) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | HRS-300, HRS-500 |
| Focal Length | 300 mm (HRS-300), 500 mm (HRS-500) |
| f-number | f/3.9 (HRS-300), f/6.5 (HRS-500) |
| Linear Dispersion | 2.38 nm/mm (HRS-300), 1.52 nm/mm (HRS-500) |
| PMT Resolution (1200 g/mm grating, 435.8 nm, 10 µm slit) | 0.09 nm (HRS-300), 0.05 nm (HRS-500) |
| CCD Resolution (1200 g/mm grating, 435.8 nm, 20 µm pixel & slit) | 0.10 nm (HRS-300), 0.07 nm (HRS-500) |