Thermo Fisher
Filter
Showing 391–420 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye HEC |
| Instrument Category | Dose Rate / Activity Meter |
| Form Factor | Portable |
| Measured Radiation Types | Alpha and Beta Emitters |
| Detector Type | Scintillation Detector (Lu₂O₃-based) |
| Counting Range | Alpha: 1–10,000 cps |
| Beta | 1–100,000 cps |
| Background | Alpha <2 cpm, Beta <70 cpm (under 0.25 µSv/h gamma background) |
| Detector Diameter | 5 cm |
| Detection Efficiency (2π geometry, 50 mm source) | Pu-239 >85%, Am-241 >75%, Tc-99 >45%, Sr/Y-90 >70%, C-14 >20% |
| Sample Chamber Dimensions | 51.6 mm × 9.6 mm |
| Adjustable Sample Height | 3.2–7.9 mm |
| Data Storage | 250 system events (alarms/errors/parameter changes), 4500 full sample records |
| Calibration & Decay Correction | Built-in automated routines |
| Interface | Serial and USB |
| Regulatory Compliance | CE Marked |
| Internal Check Source | 9 g lutetium oxide (¹⁷⁶Lu) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye NBR |
| Instrument Category | Radiation Survey Meter / Dose Rate Meter |
| Form Factor | Portable |
| Detection Target | Trace Artificial Gamma Emitters |
| Detector Type | Multi-Function NBR Probe (FHZ 674) |
| Measurement Range | 0.01 µSv/h – 100 µSv/h |
| Sensitivity | >1500 cps per µSv/h (at 30 keV) |
| Operating Temperature | −20 °C to +50 °C |
| Dimensions (RadEye SX) | 110 mm × 67 mm × 62 mm |
| Weight (RadEye SX only) | ~160 g (with 2×AA batteries and rubber boot) |
| Weight (FHZ 674 probe + SX) | ~2.8 kg (excluding shoulder strap) |
| Battery Life | ~150 h (with FHZ 674 probe, part #4250693) |
| Data Storage | 1500 measurement records + 250 operation logs |
| Alarm | Dual configurable thresholds (count rate / dose rate), audible alarm ≥80 dB at 30 cm |
| Probe Cable | RG58, up to 1.5 m, MHV connector |
| High Voltage Output | 100–1400 V, 2 MΩ load |
| Compatible Probes | 16 selectable probe types (configurable via HV, calibration factor, dead-time correction, overload threshold, and range) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye NL |
| Instrument Category | Neutron Dose Rate Meter |
| Form Factor | Portable |
| Detector Type | Pressurized He-3 Proportional Counter (2.5 bar) |
| Measurement Range | <0.2 cps (in presence of 10 mSv/h Cs-137 gamma field) |
| Neutron Sensitivity | −0.15 cps per μSv/h (calibrated to Cf-252 neutron source) |
| Background Count Rate | 0.0025 cps (at 300 m elevation) |
| Gamma Rejection Ratio | <0.2 cps for 10 mSv/h Cs-137 |
| Units Displayed | Counts per second (cps) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Personal Radiation Detector (PRD) |
| Detector Type | NaI(Tl) Scintillation Crystal |
| Measurement Principle | Gamma Photon Detection via Scintillation & Pulse Height Analysis |
| Dose Rate Range | 0.01 µSv/h – 250 µSv/h (PRD mode) |
| Extended Range (PRD-ER) | 0.01 µSv/h – 100 mSv/h |
| Energy Response Range | 60 keV – 1.3 MeV |
| Sensitivity | 150 cps/(µSv/h) for ¹³⁷Cs |
| Data Storage Capacity | 1600 dose rate readings with timestamps |
| Ingress Protection Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Battery Life | Up to 1,000 hours (typical alkaline battery operation) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Survey Meter / Dose Rate Meter |
| Detector Type | NaI(Tl), GM Tube, ZnS(Ag)-Plastic Scintillator, He-3 Proportional Counter |
| Radiation Types Detected | Alpha (α), Beta (β), Gamma (γ), X-ray, Neutron |
| Measurement Modes | Dose rate (μSv/h, mR/h), Count rate (cps), Surface contamination (Bq, Bq/cm², dpm), Spectral identification (RadEye GN+/NBR) |
| Dose Rate Range (RadEye PRD) | 0.01 μSv/h – 250 μSv/h |
| Sensitivity (Cs-137, RadEye PRD) | 150 cps per 1 μSv/h |
| Energy Response | 30 keV – 4 MeV (model-dependent) |
| Compliance | IEC 62533, IEC 62401, ANSI N42.32, ATEX II 2G Ex ia IIB T4 (G-10-Ex) |
| Operating Environment | Field-deployable, battery-powered, ruggedized for industrial, emergency response, and regulatory use |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 96000-61091 |
| Category | Mass Spectrometry Component |
| Import Status | Imported |
| Distributor Type | Authorized Third-Party Distributor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Spectrometer |
| Model | RIIDEye |
| Detector Types | NaI(Tl), LaBr₃(Ce), LiI(Eu), CLYC (Cs₂LiYCl₆:Ce) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 10 nSv/h – 0.1 Sv/h |
| Total Dose Range | 100 nSv – 1 Sv |
| Sensitivity | 3000 cps/μSv/h |
| ADC Resolution | 14-bit fast baseline restoration |
| Spectral Stabilization | K-40-based automatic temperature-compensated stabilization |
| Nuclide Library | ANSI N42.34-compliant library of 88 isotopes (expandable to 125), including ITRAP/IAEA, medical, industrial, SNM, and user-defined nuclides |
| Identification Algorithms | QCC™ Quantitative Composite Comparison and Hysteresis™ pattern-matching technologies |
| Display | 3.5″ color LCD (320×240, 32k colors) |
| Interface | 7-key single-finger keypad, Ethernet or RS-232 |
| Data Storage | ≥10,000 spectra with timestamp, GPS (optional), and full metadata |
| Power | Rechargeable battery or AA cells |
| Environmental Rating | IP67-rated ruggedized enclosure (RIIDEyeX) |
| Compliance | ANSI N42.34, IEC 62327, IEEE 309, MIL-STD-810G |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Rocket |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SAM12 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Form Factor | Portable |
| Detection Target | Gamma-emitting Radionuclides |
| Detector Technology | Co-60–Optimized Scintillation Detection with NBR (Natural Background Rejection) Algorithm |
| Measurement Scope | Discrimination of Artificial vs. Natural Gamma Radioactivity |
| Performance Context | High-reliability detection under elevated natural background radiation conditions |
| Sensitivity | Enhanced for low-level gamma contamination screening |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic LIMS Software |
| Model | SampleManager LIMS |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | 096019 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 1300 A2 |
| Instrument Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1300 × 1580 × 870 mm |
| Internal Dimensions (L×W×H) | 1200 × 780 × 630 mm |
| Filter Efficiency | >99.999% for 0.3 µm particles |
| Airflow Pattern | 30% exhaust / 70% recirculation |
| Work Area Dimensions (W×D×H) | 1200 × 495 × 780 mm or 1800 × 495 × 780 mm |
| Exhaust Flow Rate | 330 or 490 CFM |
| Work Surface Area | 0.56 or 0.84 m² |
| Sash Opening Height | 250 mm |
| Fluorescent Illumination | >65 foot-candles (fc) |
| Sound Pressure Level | 63 or 65 dB(A) |
| Heat Output at 25°C | 150 or 260 W |
| Voltage Range | 90–250 V AC |
| Power Consumption | 200 or 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 1300 B2 |
| Instrument Type | Class II, Type B2 Biosafety Cabinet |
| External Dimensions (L×W×H) | 1379 × 1844 × 803 mm |
| Internal Dimensions (L×W×H) | 1232 × (653–742) × 648 mm |
| Filter Efficiency | >99.99% for 0.3 µm particles |
| Airflow Mode | Total Exhaust (No Recirculation) |
| Inflow Velocity | 0.5 m/s (typical, per NSF/ANSI 49) |
| Downflow Velocity | 0.3 m/s (typical) |
| Exhaust Flow Rate | 665–998 CFM |
| Work Surface Area | 0.55–0.82 m² |
| Sash Opening Height | 203 mm |
| Illumination | 91 foot-candles |
| Sound Pressure Level | 65–66 dB(A) |
| Heat Dissipation at 25°C | 22–24 W |
| Voltage | 230 V AC |
| Power Consumption | 280–370 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Online Sodium Ion Analyzer |
| Model | 2111LL |
| Measurement Range | 0.001 ppb – 10 ppm |
| Detection Limit | 0.001 ppb |
| Response Time | 2 min (to 95% of final value) |
| Accuracy | ±0.1 ppb or ±0.5% (whichever is greater) |
| Temperature Operating Range | 5–45 °C |
| Electrode Type | Sodium-Selective Glass Electrode (ROSS Ultra®) |
| Calibration Method | Dual-Standard Known Addition (DKA) |
| Output | Isolated 4–20 mA (linear/logarithmic selectable) |
| Display | Backlit LCD, 54 × 76 mm, graphical marquee + concentration + mV/status |
| Power | 85–132 VAC / 170–264 VAC, 50–60 Hz |
| Enclosure Dimensions | 65 × 45 × 27 cm (L×W×D) |
| Weight | 22.7 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 2230XP |
| Type | Online Analyzer |
| Detection Range | 0–5000 ppb (SiO₂) |
| Low-Range Accuracy | Optimized for 0–500 ppb |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Light Source | 810 nm LED (filter-free, fiber-optic-free) |
| Sample Temperature Control | Integrated heater maintains 25 °C |
| Zero Calibration | Performed before each analysis cycle |
| Pump Maintenance Interval | Every 6 months |
| Power Input | 100–240 VAC, 50–60 Hz |
| Enclosure Rating | NEMA 4 |
| Data Storage | 31 days of calibration and measurement logs |
| Display | Backlit LCD with multi-parameter status view |
| Installation | Panel-mount or wall-mount compatible |
| Compliance | Designed for continuous operation in power generation, semiconductor, and pharmaceutical water monitoring environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2230XP |
| Instrument Type | Online Analyzer |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Enclosure Rating | NEMA 4 |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Measurement Range | 0–5000 ppb SiO₂ (with enhanced accuracy in 0–500 ppb sub-range) |
| Temperature Control | Heats sample to 25 °C for low-temperature inlet streams |
| Light Source | 810 nm LED (filter-free, fiber-optic-free, maintenance-free) |
| Pump Maintenance Interval | Every 6 months |
| Data Storage | 31 days of calibration and analytical records |
| Display | Backlit LCD with multi-parameter status visualization |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Sample Interface | Integrated on-line flow cell + optional grab-sample port |
| Installation | Panel-mount or wall-mount compatible |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | 4105MAT |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | 43i, 43i-HL, 43i-TLE |
| Instrument Type | Online Continuous Emission Monitor |
| Target Gas | SO₂ |
| Response Time (Lag Time) | <20 s |
| Measurement Precision | 1 ppb (for 43i) |
| Measurement Ranges | 43i: 0–0.05 / 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 ppm |
| 43i-HL | 0–10 / 20 / 50 / 100 / 200 / 500 / 1000 ppm |
| 43i-TLE | 0–10 / 20 / 50 / 100 / 200 / 500 / 1000 ppb |
| Zero Noise | 0.5 ppb RMS (60 s avg, 43i) / 0.25 ppm RMS (300 s avg, 43i-HL) / 0.025 ppb RMS (300 s avg, 43i-TLE) |
| Detection Limit | <0.5 ppb (43i) / 0.5 ppm (43i-HL) / 0.05 ppb (43i-TLE) |
| Zero Drift (24 h) | <1.0 ppb (43i) / <1 ppm (43i-HL) / <0.2 ppb (43i-TLE) |
| Span Drift (24 h) | ±0.5% FS (43i) / ±1% FS (43i-HL & 43i-TLE) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Variants | 48i, 48i-HL, 48i-TLE |
| Instrument Type | Online Continuous Emission Monitor |
| Measurement Principle | Gas Filter Correlation Infrared (GFC-IR) Absorption |
| Detection Target | Single-component CO gas |
| Range Options | 0–1 to 0–10,000 ppm (48i) |
| Repeatability | ±0.1 ppm |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤60 s |
| Zero Drift (24 h) | <0.1 ppm (48i/48i-TLE), <4 ppm (48i-HL) |
| Span Drift (24 h) | ±1% FS (48i/48i-TLE), ±2% FS (48i-HL) |
| Linearity Error | ±1% FS (<1000 ppm), ±2.5% FS (>1000 ppm) |
| Zero Noise | 0.02 ppm RMS (30-s avg, 48i/48i-TLE), 2.0 ppm RMS (10-s avg, 48i-HL) |
| MDL | 0.04 ppm (48i/48i-TLE), 4.0 ppm (48i-HL) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 55i |
| Price | Upon Request |
| Measurement Principle | Back-Flush Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Detection Target | CH₄ and Total Non-Methane Hydrocarbons (TNMHC) |
| Analysis Cycle | 70 seconds |
| Detection Limit | 0.050 ppm (as propane, 300-s average) |
| Zero Noise | 0.025 ppm RMS |
| Precision | ±2.0% of reading or ±50 ppb (whichever is greater) |
| Linearity | ±2% of span (10–100% full scale) |
| Operating Temperature | 15–35 °C |
| Power Requirement | 100–240 V AC, 50/60 Hz, 420 W |
| Dimensions | 42.5 × 21.9 × 58.4 cm (W×H×D) |
| Weight | 27.2 kg |
| Sample Flow Rate | ≥0.5 L/min |
| Carrier Gas | N₂ (25–50 mL/min) |
| Zero Air | 275–350 mL/min (hydrocarbon-free) |
| Fuel Gas | H₂ (25–50 mL/min) or H₂/He mix (100–150 mL/min) |
| Output Options | 0–20/4–20 mA (isolated), RS232/RS485, TCP/IP, 10 relay status outputs, power failure alarm |
| Input Options | 16-bit digital input (standard), 8–10 V analog input (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 70111-61340 |
| Price | USD 4,500 (approx.) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Ambient Gas MS |
| Type | Fully Automated Ambient Air Quality Monitoring System |
| Compliance | EPA Reference/Equivalent Methods, CNAS-ISO/IEC 17025 Accredited Deployment, Meets China HJ 653–2013 & HJ 654–2013 Standards |
| Data Capture Rate | >90% (7-day rolling average) |
| Measurement Uncertainty | ≤1% deviation between acquired and true reference values |
| Output Interfaces | 0–10 V analog, RS-232/RS-485 bidirectional digital communication |
| Software Platform | ENVIDATA v5.x (Windows-based, 21 CFR Part 11 compliant audit trail option available) |
| Configuration | Central Station + Remote Substations + QA/QC Laboratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ambient Gas MS |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Apreo ChemiSEM |
| Quotation | Upon Request |
| Instrument Form Factor | Floor-Standing |
| Electron Source Type | Thermal Field-Emission Gun (TFEG) |
| Microscope Class | Ultra-High-Resolution Field-Emission SEM |
| Secondary Electron Resolution | 0.7 nm @ 30 kV |
| Magnification Range | 29× to 200,000× |
| Accelerating Voltage Range | 200 V – 30 kV |
| Backscattered Electron Resolution | 0.8 nm @ 1 kV |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ASM-IV |
| Instrument Category | Radiation Dose Rate Meter |
| Form Factor | Portable |
| Measured Substance | Radioactive Materials |
| Detector Type | Large-Volume Scintillation Detector |
| Measurement Scope | Wide Dynamic Range |
| Sensitivity | High |
| Compliance | ANSI N42.35-2006 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CAD |
| Instrument Type | Universal Chromatographic Detector |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1200 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Maximum Operating Pressure | 1200 bar |
| Column Compatibility | 75 cm columns packed with 1.9 µm particles |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EV-1000 VOCs CEMS |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Multi-component VOC Analyzer |
| Detection Range | Volatile Organic Compounds (VOCs), configurable up to 50 ppm, 500 ppm, 5000 ppm, 5% or 50% as methane |
| Resolution | 0.05 ppm |
| Accuracy | ±1 % of full scale or ±0.1 ppm (whichever is tighter) |
| Response Time | ≤60 seconds (average analysis cycle time) |
| Repeatability | ±1 % f.s. or ±0.1 ppm |
| Zero Drift | ±1 % f.s. or ±0.1 ppm |
| Span Drift | ±2 % f.s. or ±0.1 ppm |
| Sample Flow Rate | 600 mL/min (analysis stream) |
| Sample Replacement Rate | 3–10 L/min (max) |
| Calibration Interval | User-configurable (monthly to annual) |
| Operating Temperature | 0–45 °C |
| Ambient Storage Temperature | –20–60 °C |
| Relative Humidity | 0–85 % RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz, 1.5 kW |
| Dimensions | 650 mm (W) × 580 mm (D) × 1250 mm (H) |
| Weight | 160 kg |
| Carrier Gas | Oil/water-free air or N₂, 60 mL/min at 2 kg/cm², THC < 0.1 ppm |
| FID Fuel Gas | H₂, 30 mL/min at 2 kg/cm², purity >99.999%, THC < 0.1 ppm |
| FID Make-up Gas | Oil/water-free air, 300 mL/min at 2 kg/cm², THC < 0.1 ppm |
| Zero Gas | Oil/water-free air or N₂, 2 kg/cm², THC < 0.1 ppm |
| Span Gas | Hydrocarbon standard in balance gas (air or N₂), 1 kg/cm² inlet pressure |
| Purge Gas | Oil/water-free air, 10 L/min at 2 kg/cm², THC < 1 ppm |
| Standard Output | Modbus TCP |
| Optional Outputs | 4–20 mA, RS232, RS485 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Evolution One Plus |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm to 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm (at Hg lines 541.9 nm and 546.1 nm), ±0.8 nm (full range 190–1100 nm) |
| Wavelength Repeatability | ≤0.05 nm (SD, n=10 at 546.1 nm Hg line) |
| Stray Light | <0.01% T (i.e., >2 A at specified wavelengths) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution One |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.5–4 nm (selectable) |
| Wavelength Accuracy | ±0.5 nm (at Hg emission lines 541.9 nm and 546.1 nm), ±0.8 nm (full range) |
| Wavelength Repeatability | ≤0.05 nm (SD, 10 measurements at 546.1 nm Hg line) |
| Stray Light | <0.01% T (at 220 nm, NaI |