Thermo Fisher
Filter
Showing 421–450 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Israel |
| Manufacturer | OPGAL (Thermo Fisher subsidiary) |
| Type | Portable OGI Camera |
| Detection Principle | Infrared Absorption Imaging (Mid-Wave IR, MWIR) |
| Detection Range | >400 VOCs including methane, ethylene, propane, butane, pentane, hexane, heptane, octane, benzene, toluene, xylene, styrene, ethylbenzene, formaldehyde, acetaldehyde, propionaldehyde, butadiene, butene, isobutylene, isoprene, methanol, ethanol, isopropanol, methyl ethyl ketone, acetone, ethyl acetate, methyl acetate, ethylene oxide, propylene oxide, acetic acid, and other hydrocarbons & oxygenates |
| Display Resolution | 640 × 480 |
| Thermal Sensitivity (NETD) | <12 mK @ 25 °C (for methane) |
| Temperature Measurement Accuracy | ±1 °C (0–100 °C) |
| Response Time | Real-time / ≤0.1 s |
| Certifications | ATEX Zone 2 |
| Data Storage | Integrated 64 GB SSD |
| Connectivity | Built-in Wi-Fi for live streaming and remote file transfer |
| LDAR Integration | Onboard LDAR workflow engine with component tagging, geotagging, and Method 21 data fusion (PID/FID) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Box-Type Muffle Furnace |
| Model | F30400 |
| Maximum Temperature | 1200°C |
| Temperature Uniformity (at 1000°C) | ±3.45°C |
| Temperature Stability (at 1000°C) | ±1.2°C |
| Control Accuracy | ±2–4°C |
| Chamber Dimensions (W×H×D) | 360 × 360 × 360 mm |
| Chamber Volume | 45 L |
| Max Power | 5500 W |
| Heating Rate (to max temp) | 6–12°C/min |
| Heating Method | Resistance Wire Heating |
| Electrical Supply | 240 V, 50/60 Hz, 22.9 A |
| Weight (Shipping) | 117.9 kg |
| Safety | 35 A Circuit Breaker, Door-Interlocked Power Cut-off, Mechanical Over-Temperature Relay |
| Optional Accessories | Dual Removable Shelves (enabling up to 3× sample capacity) |
| Exhaust Port | 9.5 mm diameter rear port for external monitoring or venting |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Crucible Muffle Furnace |
| Max Temperature | 975°C / 1093°C (with Inconel manifold) |
| Temperature Control Accuracy | ±2–4°C |
| Max Power | 5500 W |
| Heating Rate to Max Temp | 6–12°C/min |
| Heating Method | Resistance Wire Heating |
| Internal Dimensions | 360 × 360 × 360 mm / 330 × 180 × 250 mm |
| Chamber Volume | 45 L / 14 L |
| Compliance | ASTM D3174 |
| Control Options | B1 (single-setpoint), C1 (8-segment program), D1 (4×16-segment program + RS232) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Box-Type Muffle Furnace |
| Model | F6000 |
| Max Temperature | 1200°C |
| Temperature Uniformity (at 1000°C) | ±2.2°C |
| Temperature Stability (at 1000°C) | ±0.2°C |
| Control Accuracy | ±2–4°C |
| Max Power | 4400 W |
| Heating Rate (to 1200°C) | 6–12°C/min |
| Heating Method | Resistance Wire Heating |
| Internal Dimensions (W×H×D) | 330 × 180 × 250 mm |
| Chamber Volume | 14 L |
| External Dimensions (W×H×D) | 485 × 533 × 749 mm (with door open) |
| Net Weight | 60.8 kg |
| Safety Features | Door-Interlocked Power Cut-off, Thermocouple Fault Protection, Mechanical Over-Temperature Relay (on B1/C1/D1 variants) |
| Optional Accessories | Stainless Steel Shelf (max service temp: 900°C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GasBench II |
| Instrument Category | Stable Isotope Ratio Mass Spectrometer Interface |
| Measurement Precision | High-precision isotopic ratio analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Heracell VIOS 160i |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.3 °C |
| Humidity Range & Accuracy | 20–95% RH |
| Chamber Volume | 165 L |
| CO₂ Sensor | IR180Si infrared (MEMS-based) |
| Optional O₂ Control | 1–21% |
| Sterilization Cycle | Steri-Run dry heat at 180 °C (12-log SAL) |
| Air Filtration | Internal HEPA filter (ISO Class 5) |
| Chamber Liner Options | Electropolished stainless steel or 100% pure copper |
| Door Configuration | 6 airtight individual doors + 3 adjustable shelves |
| Humidification System | Integrated covered reservoir (condensation-free operation) |
| Control Interface | iCAN touchscreen with full audit trail and parameter logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Low-Concentration CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | SO₂, NOₓ, Particulate Matter (PM), Hg, NH₃ |
| Integrated with Thermo Fisher Analyzers | 43i (SO₂), 42i (NOₓ), 48i (CO), 410i (CO₂), 17i (NH₃), PM CEMS, Mercury Freedom™ |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PreCon |
| Instrument Type | Stable Isotope Ratio Mass Spectrometry (IRMS) Pre-Concentration System |
| Measurement Precision | High-Precision Isotopic Ratio Analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | Protect-1FD (Catalog No. 117122004) |
| ISO Class | 5 (Formerly Class 100) |
| Airflow Pattern | Vertical Downflow |
| User Capacity | Dual-Operator, Dual-Facing |
| Noise Level | ≤65 dB(A) |
| Work Surface | 304 Stainless Steel |
| Pre-filter | Integrated Particle & Grease Pre-filter |
| HEPA Filter | AAF Ultra-Low Penetration Air (ULPA)-equivalent HEPA, ≥99.995% @ 0.3 µm |
| Sash Height Adjustment | Motorized or counterbalanced 5 mm tempered glass sash with positional memory and height-limit safety interlock |
| Fan Control | 8-step adjustable DC EC fan with real-time LCD wind speed display (m/s) |
| UV System | Timer-controlled germicidal UV-C lamp (254 nm) with usage-hour monitoring and automatic shutoff interlock |
| Safety Interlocks | UV lamp disabled when sash is open > safety threshold |
| Service Ports | PAO upstream test port for quantitative HEPA integrity testing (e.g., EN 1822, ISO 14644-3) |
| Power Outlets | Two splash-proof, grounded 120 V AC outlets integrated into work area |
| Compliance | Designed to meet NSF/ANSI 49–2022 (Class I), ISO 14644-1, and EU GMP Annex 1 (2022) environmental control requirements for non-sterile compounding and low-risk aseptic processing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-DF |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter) |
| Compliance | U.S. EPA Equivalent Method EQPM-0609-182 |
| Operating Temperature Range | −40 °C to +60 °C (sample gas) |
| Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Output Interval | Configurable from 10 sec to 24 hr |
| Internal Memory | 500,000 records |
| Analog Outputs | 8 user-defined (0–1 V or 0–5 V DC) |
| Digital Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Power | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in |
| Weight | 38 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ThermoMixer C |
| Temperature Range | 4–95 °C |
| Type | Refrigerated & Heating Metal Block Thermostat |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Cooling Method | Peltier-based active cooling |
| Heating Method | Precision resistive heating |
| Block Material | Anodized aluminum alloy |
| Block Compatibility | Interchangeable blocks for 0.2 mL, 0.5 mL, 1.5 mL, 2.0 mL tubes, PCR strips, and 96-well plates |
| Temperature Uniformity | ±0.2 °C across block surface (at 37 °C) |
| Temperature Accuracy | ±0.1 °C (at 37 °C) |
| Ramp Rate | Up to 2.5 °C/min (heating), 1.8 °C/min (cooling) |
| Control Interface | Touchscreen with intuitive icon-driven menu |
| Data Logging | Internal memory for up to 1,000 temperature/time records |
| Connectivity | USB port for data export and firmware updates |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Transcend II |
| Instrument Type | UHPLC–Online Solid-Phase Extraction (SPE) Coupled System |
| Configuration Flexibility | Single-method quad-channel or multi-method independent-channel operation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | TriPlus RSH |
| Instrument Category | Gas Chromatography Autosampler |
| Sample Capacity | 972 × 2 mL vials + multiple 100 mL wash/waste bottles |
| Needle Exchange | Automatic Tool Change (ATC) |
| Minimum Sample Uptake | 5 µL (with bottom-sensing precision) |
| Liquid Injection Modes | Conventional, Fast (<100 ms), Sandwich |
| Headspace Capacity | 300 × 10/20 mL vials |
| SPME Automation | Full cycle (conditioning, extraction, desorption, cleaning) |
| Integrated Functions | Continuous dilution, spiking, derivatization, vortexing, barcode reading |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tube Rotator |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Horizon UHPLC System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Maximum Pressure | 1500 bar |
| Flow Rate Range | Up to 5 mL/min |
| Solvent Channels | 2 × 3 (six independent solvent lines, enabling up to nine binary gradient combinations) |
| Column Oven Temperature Range | 5–120 °C with dual-gas thermal regulation |
| Sample Capacity (Standard) | 208 injections (single vial) |
| Sample Capacity (Optional Loader) | 8832 injections (23-position microplate format) |
| Detector | Diode Array Detector (DAD) with LightPipe™ technology, 3000 mAU linearity, ±3 µAU noise level |
| Software | Thermo Scientific Dionex Chromeleon CDS (FDA 21 CFR Part 11 compliant, GLP/GMP audit trail enabled) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Pro |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) Coupled Online Sampling |
| Instrument Type | Continuous Online Analyzer |
| Typical Configuration | Multi-Channel VOC Monitoring System |
| Detection Range | 0.01–1 ppm (v/v) |
| Resolution | Dual Slit Selection — 60 (1 mm slit), 20 (4 mm slit) |
| Accuracy | <0.1% relative error |
| Response Time | ≤15 min for up to 100 sampling points |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Sentinel Pro |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) Coupled Online Sampling |
| Instrument Category | Online Real-Time Analyzer |
| Typical Configuration | Multi-Channel VOC Monitoring System |
| Detection Range | 0.01–1 ppm (v/v) |
| Resolution | Dual-Slit Selector — 60 (1 mm slit), 20 (4 mm slit) |
| Accuracy | <0.1% relative precision |
| Response Time | ≤15 min for up to 100 sampling points |
| Brand | Thermo Fisher |
|---|---|
| Origin | Japan |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | SeqStudio Flex |
| Instrument Category | First-Generation (Sanger) Sequencer |
| Throughput | Supports up to 4 sample plates (96-well, 384-well, or 8-tube strips) |
| Data Output Format | Capillary Electrophoresis (CE) Trace Files (.fsa) |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Capillary Configuration | 8-capillary or 24-capillary array |
| Connectivity | LAN, Wi-Fi, USB, LIMS integration |
| Software Options | Secure Audit & Electronic Signature (SAE) module compliant with 21 CFR Part 11 |
| Remote Service Capability | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | SGS I, SGS II |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Portability | Portable |
| Measured Radiation Types | Gamma (γ) and Neutron (n) |
| Detector Configuration | Dual plastic scintillator gamma detectors |
| Gamma Sensitivity | 500 cps/μR/h |
| Neutron Detection | He-3 proportional counter (3 atm) |
| Operating Temperature | –20 °C to +50 °C |
| Compliance | IAEA TS-G-1.2, ITRAP+10, ANSI N42.35-2019 |
| Data Storage | 1300 measurement records |
| Communication | RS-485 (to detectors), RS-232 (to PC) |
| Alarm Logic | Dual-threshold per channel, configurable alarm levels |
| Gamma Detector Volume (SGS I) | 50 L total (2 × 25 L) |
| Gamma Detector Volume (SGS II per 1500 GN unit) | 25 L |
| Neutron Detection Limit (SGS II, 10 s, 2 m, 252Cf) | 20,000 n/s |
| Gamma Detection Limit (SGS II) | <100 nSv/h (background 200 nSv/h) |
| Detection Probability | >99.9% |
| False Alarm Rate | <1 per 10,000 measurements |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Ultra-Pure Water System |
| Models | 50129845, 50129688, 50129870, 50129872 |
| Purified Water Grade | ASTM Type I (ISO 3696 Grade 1) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | 1–5 ppb |
| Microbial Contamination | < 0.001 EU/mL |
| Particulates (>0.1 µm) | < 1 particle/mL |
| UV Lamp & UF Filter | Optional |
| CO₂ Absorber | Optional |
| Integrated Reservoir | 6 L (Smart2Pure 3/6), 30 or 60 L (Smart2Pure 12) |
| Circulation Pump | Integrated |
| Wall-Mountable | Yes |
| Display | Tilt-adjustable LCD |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model No. | 75006590 |
| Instrument Type | Floor-standing Centrifuge |
| Speed Class | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Cooling Function | Refrigerated Centrifuge |
| Configuration | Fixed-angle Rotor System |
| Maximum Capacity | 6 L |
| Maximum RCF | 100,605 × g |
| Rotor Interface | Auto-ID Enabled |
| Display | Centri-Touch High-Visibility Touchscreen |
| Connectivity | Centri-Vue Mobile App (Local & Networked Control) |
| Compliance | GLP/GMP-Ready Data Management, FDA 21 CFR Part 11 Compatible Audit Trail Support |
| Safety | Integrated HEPA Filtration Option, Non-bolted Door Mechanism, Automatic Lid Locking |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Sorvall LYNX |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–29,000 rpm |
| Max RCF | 100,650 × g |
| Max Capacity | 6 × 1000 mL |
| Dimensions (H×D×W) | 930 × 805 × 700 mm |
| Weight | 293 kg |
| Temperature Range | –20 to +40 °C |
| Vacuum System | Intelligent vacuum system with optional HEPA filtration |
| Drive | High-torque brushless motor |
| Rotor Locking | Auto-Lock® |
| Rotor Recognition | Auto-ID® |
| Rotor Material | Fiberlite® carbon fiber |
| Biosafety | ClickSeal® biocontainment lid |
| Acceleration/Deceleration | 9 acceleration / 10 deceleration profiles |
| Run Time | Up to 99 h continuous |
| Pre-cooling | Yes |
| ACE Integrator | Yes |
| Compliance Features | User log, role-based access control, audit trail, automatic door opening, rotor cover handle, integrated training videos, multilingual UI |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | MTX 150 |
| Max. Capacity | 6 × 30 mL |
| Max. Speed | 150,000 rpm |
| Dimensions (H×W×D, lid closed) | 40 cm × 59 cm × 58 cm |
| Noise Level | <45 dBA |
| Max. RCF | 1,048,000 × g |
| Acceleration Time to 150,000 rpm (with S150-AT rotor) | ≤80 s |
| Power Supply | Standard laboratory AC outlet (100–240 V, 50/60 Hz) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ST 8 |
| Maximum RCF | 24,328 × g |
| Max Speed | 16,000 rpm |
| Min Speed | 300 rpm |
| Capacity (Horizontal) | 4 × 145 mL |
| Capacity (Fixed-Angle) | 6 × 50 mL |
| Rotor Locking | Auto-Lock® |
| Biosafety Lid | ClickSeal® Certified |
| Control System | Microprocessor-Driven Direct-Drive Induction Motor |
| Acceleration/Deceleration Profiles | 2 (Standard & Soft) |
| Timer Range | 0–9 h 59 min + Continuous |
| Noise Level | <58 dBA (TX-150), <61 dBA (MicroClick 24) |
| Power Consumption | 310 W |
| Dimensions (H×W×D) | 67 cm (lid open) / 31 cm (lid closed) × 37 cm × 48 cm |
| Weight | 35 kg |
| Program Storage | 4 User-Named Protocols with Password Protection |
| Compliance | IEC 61010-1, ISO 13485 (for in vitro diagnostic use), EN 61326-1 (EMC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ST16R / ST40R |
| Max Rotor Capacity | 4×750 mL (ST40R, BIOLiner rotor) |
| Max Speed | 15,200 rpm (micro-angle rotors) |
| Max RCF | 25,830 ×g |
| Temperature Range | –10°C to +40°C |
| Acceleration/Deceleration Steps | 9/10 |
| Timer Range | 9 hr 59 min + continuous |
| Noise Level | <61 dBA (ST16R), <61 dBA (ST40R) |
| Refrigeration | CFC-free compressor-based system |
| Motor | Brushless DC induction motor |
| Control System | Microprocessor-driven SMARTSpin® with 6 programmable quick-start protocols |
| Safety Certifications | IEC 61010-1, ISO 13485 compliant design, ClickSeal® biosafety-certified lid locking |
| Rotor Locking | Auto-Lock® III mechanical self-aligning rotor engagement |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Ultracentrifuge |
| Speed Range | Up to 80,000 rpm |
| Max RCF | 546,883 × g (with T-890 rotor) |
| Max Capacity | 6 × 250 mL |
| Temperature Control | Refrigerated (0–40 °C) |
| Cooling System | Solid-state thermoelectric (CFC/HCFC/HFC-free) |
| Dimensions (H×W×D) | 88 × 79 × 69 cm |
| Net Weight | 390 kg |
| Noise Level | ≤51 dBA (1 m front, operational) |
| Power Supply | 208–240 V, 50/60 Hz, 16–20 A |
| Program Storage | 1,000 user-defined protocols with stepwise centrifugation |
| Compliance | CE, cCSAus |
| Rotor Type | Fixed-angle (standard configuration) |
| Application Class | Biomolecular separation (e.g., nucleic acids, viruses, subcellular organelles) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | WX100 |
| Max. Capacity | 6 × 250 mL |
| Max. Speed | 100,000 rpm |
| Dimensions (H × W × D) | 1000 mm × 790 mm × 690 mm |
| Weight | 400 kg |
| RCFmax | 802,000 × g |
| Temperature Range | 0–40 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Vacuum Level | 0.13 Pa |
| Drive System | Vacuum-coupled, imbalance-tolerant motor |
| Acceleration/Deceleration | 10/11 steps |
| Speed Setting Range | 1,000–100,000 rpm (100 rpm increments) |
| Speed Accuracy | ±10 rpm |
| Cooling System | Solid-state thermoelectric (CFC-free) |
| Vacuum System | Oil-rotary pump with dehydrator + oil diffusion pump |
| Noise Level | 53 dBA (1 m front) |
| Power Supply | 208–240 V, 50/60 Hz, single-phase, 16–20 A |
| Certifications | CE, cCSAus |
| Control Interface | Microprocessor-based, 20 programmable methods, step-wise centrifugation, RCF auto-conversion, ω²t integrator, real-time runtime control, user access levels, automatic rotor lifetime tracking |
| Heat Dissipation | <1 kW/h |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Sorvall™ Legend™ Micro 21R |
| Centrifuge Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 14,800 rpm |
| Max RCF | 21,100 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Cooling Time | ≤9 min (from 22°C to 4°C) |
| Acceleration to Max RCF | ≤12 s |
| Dimensions (W × D × H) | 33.0 × 29.5 × 44.5 cm |
| Rotor Options | 7 interchangeable microcentrifuge rotors |
| Compliance | EU Directive 98/79/EC (IVDD), IEC 61010-1, IEC 61010-2-020 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Sorvall™ ST 8 Benchtop Centrifuge |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Spectra S/TEM |
| Price Range | USD 4.2–4.9 million (approx.) |