| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ABER FUTURA |
| Pricing | Upon Request |
| Measurement Speed | Real-time |
| Measurable Cell Concentration Range | Yeast (6 µm): 10⁶–10¹⁰ cells/mL |
| Bacteria (1 µm) | 10⁹–10¹³ cells/mL |
| Animal Cells (12 µm) | 10⁵–10⁹ cells/mL |
| Plant Cells (50 µm) | 10³–10⁷ cells/mL |
| Sample Handling | Insertion-type in-line probe |
| Throughput | Continuous in-line monitoring |
| Detectable Cell Types | Plant cells, animal cells, microorganisms, bacteria |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Count 100 / Leap-Count 100A |
| Measurement Principle | Brightfield optical imaging with AI-powered image segmentation |
| Cell Diameter Range | 3–60 µm |
| Cell Concentration Range | 1×10⁴–1×10⁹ cells/mL |
| Optimal Concentration Range | 1×10⁵–1×10⁷ cells/mL |
| Viability Detection Range | 0–100% |
| Sample Volume per Chamber | 10 µL |
| Analysis Time (Leap-Count 100) | ≤8 s |
| Analysis Time (Leap-Count 100A) | ≤2 s |
| Imaging Sensor | 6 MP CMOS |
| Objective Magnification | 3× |
| Repeatability (CV) | <5% |
| Storage Capacity | 1 TB (Leap-Count 100), External PC only (Leap-Count 100A) |
| Display | 10.1″ LCD, 1920×1200 (Leap-Count 100), None (Leap-Count 100A) |
| Data Export Formats | PDF, XLS, TIFF, PNG, JPG |
| Operating System | Windows 10 or later |
| Interface | USB 3.2 Gen 2 ×2 + Ethernet (Leap-Count 100) |
| Dimensions (W×D×H) | 260×268×246 mm (flat) / 260×268×376 mm (vertical) (Leap-Count 100) |
| Weight | 6.5 kg (Leap-Count 100), 5.0 kg (Leap-Count 100A) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Anvajo |
|---|---|
| Origin | Germany |
| Model | Fluidlab R-300 |
| Detection Time | ≤20 s (cell counting) |
| Cell Concentration Range | 1×10⁴–2×10⁷ cells/mL |
| Sample Volume | <20 µL |
| Sample Throughput | 3–80 µL |
| Wavelength Range | 375–700 nm |
| Weight | 240 g |
| Sterilization Method | Alcohol-wipe compatible surface |
| Brand | Anvajo |
|---|---|
| Origin | USA (Designed in Germany, Assembled/Qualified in USA) |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | fluidlab R-300 |
| Pricing | Available Upon Request |
| Brand | Applitech |
|---|---|
| Model | Countleader FL 100 |
| Detection Principle | Digital Imaging Cytometry with Dual-Channel Fluorescence (470/525 nm & 535/617 nm) |
| Sample Volume | 15 µL per well |
| Throughput | Up to 8 samples simultaneously |
| Analysis Modes | Brightfield, Trypan Blue Exclusion, AO/PI Dual-Fluorescence, GFP/RFP Transfection Efficiency |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Consumable | Proprietary FL8-slide (8-well, single-use) |
| Software | Integrated image analysis platform with audit trail, electronic signature, and 3Q validation support |
| Data Output | PDF, Excel, TIFF |
| User Management | Three-tier role-based access control (Administrator, Operator, Viewer) |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Countleader FL 1000 |
| Pricing | Upon Request |
| Brand | Axion BioSystems |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Axion Exact FL |
| Pricing | Available Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vi-CELL BLU |
| Assay Time | Fast Mode 80 s/sample, Standard Mode 110 s/sample |
| Cell Concentration Range | 2 × 10⁴ to 1.5 × 10⁷ cells/mL |
| Sample Volume | Fast Mode 170 µL, Standard Mode 200 µL |
| Throughput | 96 samples per run |
| Detectable Cell Size | 2–60 µm |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | TC20 |
| Measurement Time | 30 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 2 samples per run |
| Detectable Cell Diameter | 6–50 µm |
| Data Storage | Internal memory for 100 assays |
| Dimensions (W × D × H) | 19 × 15 × 25.4 cm |
| Weight | 2.2 kg |
| Brand | Chuanyi Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Qi3531 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Sample Throughput | Up to 20 cell types per analysis session |
| Power Supply | Dual-mode (AC adapter + internal rechargeable battery) |
| Display | Integrated LCD screen with real-time classification summary |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Countess® |
| Detection Range | 1 × 10⁴ – 1 × 10⁷ cells/mL (optimal: 1 × 10⁵ – 4 × 10⁶ cells/mL) |
| Cell Size Range | 5 – 60 µm |
| Sample Volume | 10 µL |
| Counting Time | ≤30 seconds |
| Staining Method | Trypan Blue exclusion |
| Data Storage | Internal memory with USB export capability |
| Dimensions | 27 × 20 × 19 cm |
| Consumable | Single-use disposable counting chambers |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COUNTESS® II FL |
| Price Range | USD 7,000 – 14,000 (FOB US) |
| Brand | Applitech |
|---|---|
| Model | BF 100 |
| Principle | Trypan Blue Exclusion with Digital Image Analysis |
| Throughput | 8 samples per run |
| Sample Volume per Channel | 15 µL |
| Analysis Time | ≤90 sec for 8 samples |
| Focus | Auto-focus optical system |
| Compliance | FDA 21 CFR Part 11, GMP-aligned user management and audit trail |
| Software | Integrated analysis suite with multi-field imaging, dilution compensation, growth curve generation, and PDF/Excel/TIFF export |
| Consumable | FL8-slide (8-channel disposable chamber slide) |
| Regulatory Support | IQ/OQ/PQ documentation package included |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | FL 2000 |
| Pricing | Upon Request |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | AItair |
| Detection Time | 150 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IY1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IE1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IA1000 |
| Analysis Time | <20 s |
| Detection Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IM1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IC1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira BF |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2 – 180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 1–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Plus |
| Measurement Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Enhanced via fixed-focus optical architecture |
| Fluorescence Channels | AO/PI, GFP, RFP |
| Compliance | FDA 21 CFR Part 11, GMP-aligned data integrity framework |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Pro |
| Detection Time | 20–50 s |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Optical Magnification | 10× |
| Imaging Sensor | 8.3 MP CMOS |
| Compatible Consumables | Standard Countstar counting chambers & newly developed 60-µm-depth chambers |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-aligned |
| Validation Support | Full 3Q (IQ/OQ/PQ) documentation available |
| Data Management | Audit trail, user access control, server & printer integration |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira HT |
| Detection Concentration Range | 1 × 10⁴ – 3 × 10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 24 samples (standard) / 15 samples (fluorescence mode) |
| Detectable Cell Size | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Optimized for ≥2× field area vs. standard hemocytometer |
| Trypan Blue Mode Acquisition Time | <10 s per image |
| AO/PI Dual-Fluorescence Mode Acquisition Time | <22 s per image |
| Total Analysis Time per Sample | <30 s (brightfield), <60 s (fluorescence) |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, 3Q validation support |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Rigel |
| Detection Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Fluorescence Channels | Up to 13 (4 excitation sources + 5 emission filter combinations) |
| Regulatory Compliance | CE-marked, FDA 21 CFR Part 11–compliant software architecture |
| Intended Use | Research use only (RUO), not for diagnostic purposes |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CT-1 |
| Outer Diameter | 2.0 mm |
| Inner Diameter | 0.9 mm |
| Material | Polytetrafluoroethylene (PTFE) |
| Length | 1 m (standard) |
| Compatible with | NARISHIGE Oil-Hydraulic Micromanipulators and Injection Holders |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CT-4 |
| Material | 304 Stainless Steel (optional PTFE-lined) |
| Outer Diameter | 2.0 mm |
| Length per Coil | 1 m (standard) |
| Working Pressure | up to 20 MPa |
| Temperature Range | −20 °C to +150 °C |
| Surface Finish | Electropolished, Ra < 0.4 µm |
| Compliance | ISO 13485, RoHS, REACH, FDA-compliant variants available |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | C100TB / C100TF |
| Detection Time | 60 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 50 µL / 100 µL |
| Throughput | 12 or 24 samples per run |
| Detectable Cell Diameter | 4–200 µm |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | H120B |
| Detection Time | 60 s per sample |
| Cell Concentration Range | 1×10²–2×10⁷ cells/mL |
| Sample Volume | 50 µL or 100 µL |
| Throughput Options | 12-well or 24-well sample carousel |
| Detectable Cell Diameter | 1–80 µm |