| Brand | CYSEA |
|---|---|
| Model | STEMvision™ |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-MC |
| Detection Time (Brightfield) | <3 sec |
| Cell Concentration Range | 7×10²–2.5×10⁷ cells/mL |
| Adjustable Sample Height | 50 µm (5 µL), 100 µm (10 µL), 400 µm (40 µL) |
| Cell Diameter Range | 4–400 µm |
| Imaging Resolution | 5 MP brightfield |
| Excitation/Filter | AO 530 nm, PI 620 nm |
| Illumination | LED-based brightfield |
| Sample Stage Material | Hydrophilic quartz glass |
| Focus | Auto- and manual-focus modes |
| Power Supply | 12 V DC |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DEN-1 |
| Pricing | Upon Request |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | DEN-1 |
| Light Source | LED (565 ± 15 nm) |
| Measurement Range | 0.3–15.0 McFarland Units |
| Accuracy | ±3% |
| Standard Deviation (3.0 McF) | ±0.1 McF |
| Measurement Time | 1 s |
| Sample Tube OD | 18 mm (16 mm with D16 adapter) |
| Sample Volume | ≥2 mL |
| Display | 2-digit LED |
| Power Supply | 12 V, 300 mA |
| Operating Temperature | 4–45 °C |
| Dimensions (W×D×H) | 165 × 115 × 75 mm |
| Weight | 0.9 kg |
| Brand | Hiscore |
|---|---|
| Origin | Beijing, China |
| Model | Halocounter |
| Detection Time | 3 s |
| Cell Concentration Range | 1×10³–3×10⁷ cells/mL |
| Sample Volume | 5–40 µL |
| Throughput | 2–8 samples per run |
| Detectable Cell Diameter | 0.8–400 µm |
| Regulatory Compliance Option | FDA 21 CFR Part 11 Audit Trail (Software Module) |
| Key | Brand: NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-H2 |
| Application | Dedicated mounting system for IM-9C pneumatic microinjector with 1 mm capillary pipettes |
| Includes | HI-7 micromanipulator mount, CT-1 PTFE tubing (1 m), Type III connector, HI01PK01 silicone rubber gasket (2.5 mm ID, pack of 10) |
| Brand | JIMBIO |
|---|---|
| Model | CL II |
| Detection Time | 40 s |
| Sample Volume | 10 µL (full-sample analysis) |
| Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Particle Diameter Range | 5–30 µm |
| Resolution | 0.5 µm |
| CV Value | ≤5% |
| Cleaning | Fully automated in-situ rinse cycle |
| Data Interface | USB 2.0 |
| Power Supply | Dedicated external power adapter |
| Integrated System | Yes |
| Regulatory Compliance | 21 CFR Part 11-ready, 3Q validated (IQ/OQ/PQ documentation available) |
| Brand | Leopard |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BFCC-8 |
| Detection Time | <10 s |
| Cell Concentration Range | 2×10³–3×10⁷ cells/mL |
| Sample Volume | 10 µL |
| Sample Throughput | 1–200 µm (particle size range) |
| Detectable Cell Diameter | 1–200 µm |
| Ambient Operating Temperature | 4–32 °C |
| Relative Humidity | <80% (non-condensing) |
| Objective Lens | 10× |
| Imaging Sensor | 12 MP (12 million pixel) CMOS camera |
| Onboard Storage | 500 GB |
| Interfaces | HDMI ×1, USB ×2, RJ45 ×1 |
| Power Input | AC 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 280 × 280 × 370 mm |
| Weight | 8.2 kg |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L20001 |
| Detection Time | 30 s (fluorescence), 10 s (brightfield) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm (optimized for 5–60 µm) |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm (GFP), 600 nm (long-pass, RFP-compatible) |
| Light Source | High-stability LED |
| Image Resolution | 5 MP |
| Display | 800 × 480-pixel TFT LCD touchscreen |
| Dimensions (W×D×H) | 22 × 21 × 9 cm (8.6 × 8.3 × 3.5 in) |
| Weight | 1.8 kg (4 lb) |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L70001 |
| Detection Concentration Range | 1 × 10⁴ – 5 × 10⁷ cells/mL |
| Detectable Cell Size Range | 1–90 µm |
| Optical Modes | Brightfield, Dual-Fluorescence (Green: Ex 470±20 nm / Em 530±25 nm |
| Red | Ex 530±20 nm / Em 620±30 nm) |
| Autofocus | Motorized Precision Autofocus |
| Display | 7" Capacitive Touch LCD |
| Data Export | USB, Wi-Fi, Ethernet |
| Storage | 250 GB internal |
| Compliance | FDA 21 CFR Part 11 (via optional CountWire™ software) |
| Dimensions | 245 × 280 × 240 mm |
| Weight | 5.0 kg |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L10001 |
| Counting Time | <10 s (manual focus), <15 s (auto-focus) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Cell Size Range | 3–60 µm (optimal: 8–30 µm) |
| Viability Range | 0–100% |
| Image Resolution | 5 MP |
| Output Formats | TIFF (annotated), PDF reports |
| Dimensions (W×D×H) | 16 × 18 × 28 cm |
| Weight | 1.6 kg |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC output | 12 VDC, 3.3 A |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L30001 |
| Detection Time | 30–60 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm and 600 nm (long-pass) |
| Light Source | LED |
| Image Resolution | 5 MP |
| Display | 800 × 480 pixels |
| Dimensions (W×D×H) | 22 × 21 × 9 cm |
| Weight | 1.8 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | CytoDirect |
| Sample Volume | 20 µL |
| Pixel Size | 1.1 µm × 1.1 µm |
| Cell Diameter Range (Counting) | 2–80 µm |
| Display Resolution | 1280 × 800 px |
| Screen Size | 7 in |
| Dimensions (H×W×D) | 60 mm × 128 mm × 260 mm |
| Weight | 1.11 kg |
| Detection Technology | Digital Holographic Microscopy |
| Autofocus | Yes |
| Processing Time | < 15 s |
| Total Imaging Area | 31.28 mm² |
| Sensor Count | 2 |
| Battery | Rechargeable Li-ion |
| Power Input | USB-C |
| Connectivity | Wi-Fi, Ethernet |
| Data Export Formats | CSV, PDF, PNG, RAW |
| Sterilizable | Yes |
| Portability | Yes |
| CV (at > 5 × 10⁶ cells/mL) | ≤ 5% |
| Cell Types Supported | B cells, CHO, HEK293, HeLa, MSC, NK cells, PBMC, RBC, Sf9, T cells, iPSC, monocytes, granulocytes, *Saccharomyces cerevisiae*, oval/round plant cells |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | MDCI10000 |
| Dimensions (L×W×H) | 6 in × 11 in × 12 in |
| Weight | 5.67 lb |
| Connectivity | USB / Ethernet / Wi-Fi |
| Sample Compatibility | Adherent cells, microtissues, organoids |
| Data Management | Web-based cloud platform with audit-trail-capable image archiving and time-series growth analytics |
| Regulatory Context | Designed to support GLP-compliant cell culture monitoring |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | Scepter 3.0 |
| Measurement Time | ≤30 s per sample |
| Sample Volume | 5 µL |
| Cell Size Detection Range | 10–30 µm |
| Cell Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Throughput | Up to 100 samples per day |
| Principle | Electrical Impedance (Coulter Principle) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Modulus |
|---|---|
| Origin | USA |
| Model | COMP-U-DIFF |
| Detection Time | 1 sec per channel |
| Detection Concentration Range | 5 × 10³ to 5 × 10⁶ cells/µL |
| Sample Volume | 5 µL |
| Throughput | 12 samples per batch |
| Detectable Cell Size Range | 1–25 µm |
| Display | Backlit LCD (simultaneous 12-channel numeric readout) |
| Memory Capacity | 127 sample records |
| Interface | RS-232 dual-port (PC + printer) |
| Output Formats | Horizontal (PC), Vertical with header (printer) |
| RBC Morphology Codes | 24 predefined 4-character descriptors (e.g., HYPO, P01K), 6-tier quantification scale |
| NRBC Channel | Dedicated non-inclusive counting channel |
| Count Correction | Per-channel manual override |
| Real-time % Calculation | Auto-updated during entry |
| Audible Prompt | Every 100 counts |
| Dimensions | 15.2 × 22.9 cm (6" × 9") |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CI-1 |
| Dimensions | 20 mm (W) × 7 mm (D) × 6 mm (H) |
| Weight | 2 g |
| Material | Stainless Steel |
| Seal Type | Integrated High-Performance Elastomeric Gasket |
| Compatible Tubing | PTFE Capillary Tubing (ID 0.1–0.5 mm) |
| Application | Secure Connection Between Micropipette and PTFE Tubing in Microinjection & Electrophysiology Setups |
| Brand | Narishige |
|---|---|
| Model | CI-2 |
| Origin | Japan |
| Material | Medical-grade PEEK or 316L stainless steel |
| Interface | Luer Lock / universal threaded (optional) |
| Sealing Pressure | 0.5 MPa (dynamic) |
| Weight | 5 g |
| Dimensions (adapter body) | W20 × D7 × H6 mm |
| Compliance | ISO 9001, CE, USP Class VI |
| Sterilization | Autoclavable at 121°C for 20 min |
| Flow Rate | 1–200 µL/s (customizable) |
| Tolerance | ≤0.01 mm |
| Seal Configuration | Triple-ring (FKM fluorocarbon + silicone) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CI-3 |
| Body Material | 316L Stainless Steel or PEEK |
| Max Operating Pressure | 25 MPa |
| Temperature Range | −30 °C to +180 °C |
| Valve Type | Normally Closed / Normally Open (Selectable) |
| Flow Rate | 0.1–30 L/min |
| Actuation Torque | ≤0.2 N·m |
| Sealing | Dual O-ring + Metal Seal |
| Cycle Life | ≥100,000 cycles |
| Interface Standards | 1/8″–1/4″ NPT / BSPP / BSPT |
| Dimensions | W21 × D8 × H17 mm |
| Weight | 10 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CT-2 |
| Inner Diameter | 0.9 mm |
| Outer Diameter | 2.0 mm |
| Material | Medical-Grade Polyethylene (PE) |
| Length | 1 m (100 cm) per piece |
| Pack Quantity | 3 pieces per pack |
| Compatible With | NARISHIGE MO-202, IM-300, IM-400 Micromanipulators |
| Chemical Resistance | Resistant to alcohols, glycerol, mineral oils, silicone oils, and common hydraulic fluids used in microinjection systems |
| Sterilization | Autoclavable (121°C, 20 min), gamma-irradiated options available upon request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-11-2 |
| Actuation Type | Pneumatic |
| Control Mechanism | Coaxial coarse/fine rotary knobs |
| Syringe Stroke | 40 mm |
| Dimensions (W×D×H) | 167–214 × 55 × 78 mm |
| Weight | 680 g |
| Tubing Length | 1.2 m |
| Accessories Included | HI-9 Injector Holder, Cleaning Rod, CT-1-1.5 & CT-4 Capillary Tubing, O-rings, Silicone Grease, HI01PK01 Silicone Gasket, Hex Wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-21 |
| Plunger Stroke | 20 mm |
| Full Knob Rotation Displacement | 500 µm |
| Volume Control per Full Knob Rotation | ~10 µL |
| Compatible Capillary Tube Length | 1 m |
| Dimensions (W×D×H) | 127–147 × 56 × 78 mm |
| Weight | 620 g |
| Accessories | IM-H3 Injection Holder, HI01PK01 Cleaning Rod & Silicone Rubber Pad, IMO4 O-Ring, Silicone Grease |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-3 |
| Operating Pressure Range | 50–500 kPa |
| Time Setting Range | 10 ms – 99.99 s |
| Count Setting Range | 1–99 |
| Interval Setting Range | 10 ms – 99.99 s |
| Power Supply | AC 100–240 V (±5%), 50/60 Hz |
| Dimensions (Main Unit) | 240 × 215 × 130 mm |
| Weight (Main Unit) | 4 kg |
| Compatible Syringe Diameter | Ø5–Ø10 mm |
| Syringe Plunger Travel | 50 mm |
| Fine Adjustment Step | 500 µm |
| Accessories Included | HI-7 Syringe Holder, Tubing Connectors, Silicone O-Rings, AC Power Cord, Footswitch |
| Brand | Narishige |
|---|---|
| Model | IM-400 |
| Origin | Japan |
| Detection Time | 10 s (manual focusing) or 15 s (autofocusing) at ~1,000,000 cells/mL |
| Cell Concentration Range | 5×10⁴–10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 50,000 cells |
| Detectable Cell Diameter | 1–60 µm |
| Operating Gas Pressure (Injection/Balance) | 0–0.5 MPa |
| Supply Pressure Range | 0.4–0.7 MPa |
| Power Input | AC 100–240 V, 50/60 Hz |
| Power Consumption | 15 W |
| Control Unit Dimensions | 120 × 211 × 264 mm, 3.1 kg |
| Manipulator Unit Dimensions | 130 × 153 × 61.5 mm, 780 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | IM-H1 |
| Pricing | Available Upon Request |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-HD1 |
| Dimensions | 24 × 55 × 54 mm |
| Weight | 58 g |
| Compatible Pipettes | CT-4 (inner diameter 0.4 mm), CT-1-1.5 (inner diameter 1.5 mm) |
| Actuation | Pneumatic (foot or finger-controlled via manipulator linkage) |
| Includes | HI-9 Injector Holder, Cleaning Rod, HIO1PKO1 Silicone Gasket, Hex Wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-HD1T |
| Dimensions | 24 × 55 × 54 mm (W×D×H) |
| Weight | 58 g |
| Construction | Stainless steel housing with ergonomic form factor |
| Actuation | Pneumatic (external air supply required) |
| Control mode | Manual trigger + optional external TTL/relay interface for automated integration |
| Compatible syringes | Standard 10 µL–100 µL glass or plastic microsyringes (e.g., Drummond Nanoject, Hamilton 7000 series) |
| Accessories included | HI-9 injector holder, CT-4 polyimide tubing (0.28 mm ID), CT-1-1.5 fused silica capillary tubing (1.5 m length), HIO1PKO1 silicone O-rings, hex wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IMS-3 |
| Syringe Travel Range | 5–10 mm |
| Plunger Displacement per Full Knob Rotation | 500 µm |
| Dimensions (W×D×H) | 50 × 30 × 120 mm |
| Weight | 115 g |
| Injection Volume Control via Interchangeable Syringes (Bore Diameter | 5–10 mm) |
| Accuracy | ±0.5% |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SCIENTZ-CFS |
| Quotation | Upon Request |
| Measurement Time Range | 0–999 s (user-configurable) |
| Turbidity Detection Range | 0.00–6.00 McFarland (MCF) |
| Sample Volume | 1.5–4 mL |
| Throughput | 6 samples per run |
| Detectable Cell Size Range | 1.5–4 µm |
| Step Resolution | 0.01 MCF |
| Brand | OLS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CASY |
| Quotation | Available Upon Request |
| Measurement Time | 10 s |
| Cell Concentration Range | 1×10²–1×10⁷ cells/mL |
| Sample Volume | 10–100 µL |
| Sample Throughput | 512,000 channels |
| Detectable Cell Size Resolution | 1 in 512,000 |
| Measurement Principle | Electrical Sensing Zone (Coulter Principle), Compliant with ISO 13319 |
| Viability Assessment | Exclusion Current Elimination (ECE) Technology |
| Dynamic Diameter Ratio | >1:40 |
| Dynamic Volume Ratio | >1:70,000 |
| Channel Resolution | 512,000 size bins |
| Display Bins | 1,024 |
| Diameter Range | 0.7–120 µm |