Chemical Analysis Instruments
Filter
Showing 3961–3990 of 4194 results
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L1 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (default per spec sheet) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂ method) |
| Display | 7-inch color TFT-LCD touchscreen (1024 × 768 resolution) |
| Data Storage | 2000 spectra or absorbance readings |
| Connectivity | USB 2.0 port, integrated Wi-Fi module, Bluetooth 5.0 module |
| Software Compatibility | Yokelab PC software (optional), cloud sync via YOKE@Cloud Data app |
| Data Export | CSV/Excel-compatible format via USB flash drive |
| Compliance | Designed to support GLP-compliant workflows with timestamped audit trails, user-access logging, and exportable metadata |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L2 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (optional) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch color TFT-LCD (1024 × 768) with capacitive touch |
| Data Storage | 2000 spectra + 96 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Interface | Yokelab PC software (optional), YOKE@Cloud Data mobile app (QR-code enabled) |
| Output Format | CSV/Excel-compatible export via USB drive |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L3 |
| Optical Design | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 320–1100 nm |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤±0.5 nm |
| Stray Light | ≤0.1% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% T, –3 to +3 A |
| Photometric Accuracy | ±0.5% T / ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Photometric Repeatability | ±0.5% T / ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Baseline Stability | ±0.002 A (500 nm, 3 min) |
| Noise Level | ≤0.15% T |
| Grating | Holographic Blazed Grating, 1200 lines/mm |
| Display | 7-inch TFT-LCD Touchscreen (1024 × 768) |
| Connectivity | USB 2.0, Wi-Fi (standard), Bluetooth 4.2 (standard) |
| Data Storage | 2000 spectra + 96 calibration curves |
| Software | YokeLab PC software (optional), YOKE@Cloud IoT platform (standard) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L4 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Stray Light | ≤0.1% T |
| Display | 7-inch color TFT LCD (1024 × 768) |
| Data Storage | 2000 spectra + 96 calibration curves |
| Scan Speed | up to 3000 nm/min |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Compatibility | Yokelab PC Suite (optional), cloud-integrated via YOKE@Cloud Data app |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | L5 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Automation Level | Automatic Wavelength Selection & Lamp Switching |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L6 |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Automation Level | Automatic Wavelength Scanning & Lamp Switching |
| Connectivity | USB 2.0, Wi-Fi Module, Bluetooth 4.2 |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L8 Series |
| Price | USD 2,500 (FOB Shanghai) |
| Optical Design | Dual-Beam Ratio System |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% T (at 220 nm, using NaI solution) |
| Display | 10-inch capacitive touchscreen (1024 × 800 resolution) |
| Data Storage | Internal memory for up to 5,000 absorbance readings or 500 calibration curves |
| Connectivity | RS-232C (printer), USB Device (PC connection), USB Host (U-disk support) |
| File Export Formats | CSV, QUA, TXT, BMP |
| Optional Accessories | 8-position automated cuvette changer, integrated flow cell module |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M5 |
| Optical System | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.5 / 1 / 2 / 4 / 5 nm (adjustable) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% (at 220 nm, using NaI solution) |
| Photometric Resolution | 0.00001 Abs |
| Display | 11-inch 2.8K tablet with touch interface |
| Light Sources | Deuterium lamp + Tungsten-halogen lamp |
| Connectivity | Bluetooth, Wi-Fi, IoT-enabled remote monitoring |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M600 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Absorbance Resolution | 0.00001 Abs |
| Photometric Range | –4 to +4 Abs |
| Light Sources | Deuterium lamp (UV), Tungsten-halogen lamp (Vis) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M6S |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (standard), adjustable from 0.1 to 5 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Photometric Resolution | 0.00001 Abs |
| Auto-Wavelength Scanning | Yes |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Display | Integrated 11-inch 2.8K tablet with Bluetooth connectivity |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments, supports GLP/GMP data integrity requirements including user-level access control and audit trail-ready operation |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | M700S |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Wavelength Scanning Automation | Fully Automatic |
| Display Interface | 11-inch 2.8K resolution tablet with integrated Bluetooth connectivity |
| Software Language Support | Auto-switching between English and Chinese |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M8 |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% T (at 220 nm, NaI solution) |
| Absorbance Resolution | 0.00001 Abs |
| Absorbance Range | –4 to +4 Abs |
| Light Sources | Deuterium lamp + Tungsten-halogen lamp |
| Automation | Motorized wavelength scanning, auto-zero, auto-calibration |
| Connectivity | Bluetooth 5.0, Wi-Fi, cloud-enabled IoT architecture |
| Display | Integrated 11-inch 2.8K resolution tablet with touch interface |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M900 |
| Optical System | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Light Sources | Deuterium Lamp & Tungsten Halogen Lamp |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3604AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0–2.0 A |
| Optical System | Single-beam |
| Lamp Positions | 4 |
| Background Correction | Combined D₂ Lamp + Self-Reversal Full-Spectrum Background Correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3608AA |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Repeatability | ≤ 0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0 – 2.0 A |
| Background Correction | Deuterium Lamp + Self-Reversal Full-Spectrum Correction |
| Lamp Holder | 8-position, 360° Rotating, Compatible with High-Performance Hollow Cathode Lamps |
| Optical System | Single-Beam, All-Reflective Optics |
| Atomizer Type | Flame-Based Atomization System |
| Software Platform | RG-WinAAS Workstation (Windows OS) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3618AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Dual-Beam |
| Lamp Positions | 8-position rotating turret (compatible with high-performance hollow cathode lamps) |
| Background Correction | Combined deuterium lamp and self-reversal (SR) full-spectrum background correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3624AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Single-beam |
| Lamp Positions | 4 |
| Background Correction | D₂ Lamp + Self-Reversal Full-Spectrum Correction |
| Atomizer Type | Electrothermal Graphite Furnace |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RG-3628AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Spectral Bandwidth | 0.1, 0.2, 0.7, 1.4, 2.0 nm (5-step automatic selection) |
| Lamp Positions | 8-slot rotating turret (360° motorized rotation) |
| Atomization Modes | Flame and External Graphite Furnace |
| Background Correction | Dual-mode — D₂ continuum lamp (full-spectrum) and high-performance self-reversal (SR) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3638AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Single-beam |
| Lamp Positions | 8-position rotating turret (360° rotation, compatible with high-performance hollow cathode lamps) |
| Background Correction | Dual-mode — D₂ lamp + self-reversal (SR) full-spectrum background correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3668AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0–2.0 A |
| Optical System | Dual-beam |
| Lamp Positions | 8-position rotating turret (compatible with high-performance hollow cathode lamps) |
| Background Correction | Combined deuterium lamp and self-reversal (SR) background correction across full wavelength range |
| Software Platform | RG-WinAAS workstation for Windows OS |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-N6000 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch color TFT touchscreen |
| Data Storage | Internal 8 GB flash memory (supports ≥5000 absorbance readings or ≥500 calibration curves) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 hours (dual-lamp auto-switching with usage logging) |
| Grating | 1200 lines/mm plane holographic grating |
| Interface | RS-232, USB Host (Type-B), USB Device (Type-A), optional thermal printer port |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 8 GB internal memory (supports ≥5000 absorbance readings or 500 calibration curves) |
| Microprocessor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 hours (automated D₂ and W lamp switching with usage logging) |
| Grating | 1200 lines/mm holographic plane grating |
| Sample Compartment | Extra-large, compatible with optional 8-position rotating carousel and 5-cell wide-format cuvette holder |
| Interface Ports | RS-232 printer port, USB Host (Type-B), USB Device (Type-A), SD/USB flash drive export |
| Software | PC-based spectral analysis suite with GLP-compliant audit trail, CFR Part 11 ready configuration options |
| Firmware | Field-upgradable via network download |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-N6000Plus |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch color TFT LCD |
| Data Storage | 8 GB internal flash memory (supports up to 5000 absorbance readings or 500 calibration curves) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 hours (automatically switched D₂ and W lamp with usage tracking) |
| Grating | 1200 lines/mm holographic plane grating |
| Sample Compartment | Large-volume chamber compatible with optional 8-position rotating carousel or 5-position ultra-wide sample holder |
| Connectivity | RS-232 printer port, USB Host (Type-B), USB Device (Type-A), firmware upgrade via network |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-U6S |
| Optical System | Dual-beam with CT monochromator |
| Detector | Hamamatsu photomultiplier tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm (fixed) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Display | 7-inch TFT-LCD (1024×768) with Omron tactile keypad |
| Internal Storage | 32 GB flash memory |
| Data Capacity | Up to 5,000 absorbance measurements or 500 calibration curves |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Interface | RS-232C (printer), USB Device (PC connection), USB Host (U-disk support) |
| File Export Formats | CSV, QUA, TXT, BMP |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T-U8 |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (2 nm optional) |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Light Source | Pulsed Xenon Lamp |
| Automation Level | Automatic Wavelength Scanning |
| Display | 7-inch TFT True-Color LCD |
| Data Storage | Internal 32 GB + USB Host (U-disk support) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Data Capacity | Up to 5,000 absorbance readings or 500 calibration curves |
| Interface | RS-232C (printer), USB Device (PC connection), USB Host (U-disk) |
| Output Formats | *.csv, *.qua, *.txt, *.bmp |
| Language Support | English & Chinese |
| Optional Accessory | 8-position Rotating Cuvette Holder |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-U9 |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Automation Level | Automatic Wavelength Scanning |
| Light Source | Pulsed Xenon Lamp |
| Display | 10.1-inch Color Touchscreen |
| Internal Storage | 32 GB |
| Data Storage Capacity | Up to 5,000 absorbance readings or 500 calibration curves |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Interface Ports | RS-232C (for printer), USB Device (for PC connection), USB Host (for U-disk), Support for CSV, QUA, TXT, BMP export formats |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T2602 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% T (at 220 nm, using NaI solution) |
| Display | 7-inch TFT color LCD (1024 × 600 resolution) |
| Data Storage | 16 GB internal memory |
| Interfaces | RS-232C, USB Device, USB Host |
| Supported Output Formats | CSV, QUA, TXT, BMP |
| Maximum Data Capacity | 2000 absorbance measurements or 500 calibration curves |
| Light Sources | Imported deuterium lamp and tungsten-halogen lamp |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T2602S |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (selectable) |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch TFT true-color LCD |
| Data Storage | Internal 16 GB + USB flash drive support |
| Connectivity | RS-232C, USB Device, USB Host |
| Processor | ARM11 |
| Data Capacity | Up to 2000 absorbance measurements or 500 calibration curves |
| Optional Accessories | 8-position rotating cuvette holder, integrated auto-sampler flow path |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T3202S |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (standard), adjustable to 0.5/1/2/4/5 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal 8 GB + USB drive support |
| Interface | RS-232C, USB Device, USB Host |
| Onboard Memory | Up to 5000 absorbance measurements or 500 calibration curves |
| Optional Accessories | 8-position rotating cuvette changer, integrated flow cell system |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TSF-50A-5 |
| Heating Source | Halogen Lamp |
| Display | 4.3-inch Capacitive Touchscreen LCD |
| Readability | 0.01% / 1 mg |
| Compliance | GB/T 29249–2012 (Electronic Moisture Analyzer Based on Drying Method) |
| Interface | RS232 for Printer & PC Connectivity |
| Data Output | Real-time Drying Curve, Auto-finalization, Lock-on-Completion |