| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9681-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Combined Glass/Reference/ATC (Integrated Temperature Compensation) |
| Construction | Ruggedized Plastic Body with Hemispherical Tip |
| Sensing Surface | Flat-Tip Glass Membrane |
| Compliance | Meets JIS Z 8802 for pH electrode mechanical strength (10× requirement) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Instrument Type | Imported |
| Model | AquaLog |
| Wavelength Range (Excitation) | 200–800 nm |
| Wavelength Range (Emission) | 250–800 nm |
| Wavelength Range (Absorption) | 230–800 nm |
| Excitation Monochromator | Dual-grating with automatic order-sorting filter wheel |
| Emission Monochromator | CCD-based spectrometer with 405 g/mm grating (blazed at 250 nm) |
| Spectral Bandwidth (Slit) | 5 nm |
| Spectral Resolution | 0.41 nm/pixel (configurable to 0.82, 1.64, 3.28 nm/pixel) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio | >20,000:1 (RMS, 350 nm excitation, water Raman peak) |
| Full EEM Acquisition Time | 30 s |
| Full Emission Spectrum Readout Time | 5 ms |
| Detector | TE-cooled back-illuminated CCD |
| Built-in Corrections | Dark current, excitation source drift, excitation/emission spectral response, inner-filter effect, 1st/2nd-order Rayleigh scatter zeroing, Raman peak subtraction |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualog® |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Optical Resolution | 0.58 nm |
| Sensitivity | 20,000:1 (SNR, RMS, water Raman at 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1.0 nm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Measurement Principle | Ion-selective Electrode Method |
| Salinity Range | 0.1–10% (NaCl, w/w) |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Resolution | 0.1% |
| Minimum Sample Volume | 0.05 mL × 2 or ≥0.3 mL |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| Auto-Hold Function | Yes |
| Ingress Protection | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | ~50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.0–10% (NaCl) |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Resistivity Range | 0–19.9 mS/cm (expressed as reciprocal conductivity) |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% (salinity), 0.1 mS/cm (conductivity), 1 ppm (TDS), 0.1 °C (temperature) |
| Calibration | Two-point calibration with NaCl standard solutions |
| Temperature Compensation | Automatic, fixed 2%/°C coefficient |
| Ingress Protection | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | Approx. 50 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, batteries excluded) |
| Measurement Principle | Ion-selective electrode (ISE) method for NaCl-specific salinity |
| Sample Volume | 0.05 mL × 2 or ≥0.3 mL |
| Calibration | Two-point calibration with standard NaCl solutions |
| Compliance | Designed for field and lab use under ISO 8665, ASTM D1125, and USP <645> environmental constraints |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Measurement Principle | Ion-selective electrode (NaCl-specific) |
| Salinity Range | 0.1–10% (w/w NaCl) |
| Temperature Range | 5–40 °C |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| Accuracy | ±10% of reading |
| Resolution | 0.1% |
| IP Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe tip) |
| Weight | ~50 g (instrument only, no batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic, fixed 2%/°C coefficient |
| Protection Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | ~50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Measurement Principle | Ion-Selective Electrode Method |
| Salinity Range | 0.1–10% w/w (based on specific gravity) |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Resolution | 0.1% |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | Approx. 50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salt Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-731 |
| Type | Pen-style portable ion meter |
| Measurement Principle | Solid-state ion-selective electrode (ISE) method |
| Measuring Range | 39–3900 ppm (mg/L) or 10⁻³–10⁻¹ mol/L K⁺ |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Resolution | 0.1 ppm (mg/L) |
| Calibration | Two-point calibration |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | Approx. 50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-731 |
| Measurement Principle | Solid-State Ion-Selective Electrode (ISE) Method |
| Detection Parameter | Single-Parameter (K⁺) |
| Portability | Pen-Type Design |
| Sample Volume Requirement | 0.05 mL (minimum, dual measurement) or ≥0.3 mL |
| Measurement Range | 39–3900 ppm (mg/L), equivalent to 1.0 × 10⁻³ – 1.0 × 10⁻¹ mol/L |
| Calibration | Two-Point Calibration |
| Accuracy | ±10% of reading |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| Resolution | 0.1 ppm (mg/L) |
| Temperature Measurement Range | 0–40 °C |
| Temperature Accuracy | ±0.5 °C |
| IP Rating | IP67 |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | Two CR2032 lithium coin cells |
| Dimensions | 164 × 29 × 20 mm (excluding probe protrusion) |
| Weight | Approx. 50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-741/B-742/B-743 |
| Detection Parameter | Nitrate (NO₃⁻) only |
| Portability | Pen-type |
| Temperature Measurement Range | 5–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| NO₃⁻ Measurement Range | 62–6200 mg/L (10⁻³–10⁻¹ mol/L) |
| NO₃⁻-N Range | 14–1400 mg/L |
| Calibration | Two-point calibration |
| Accuracy | ±10% of reading |
| IP Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-741/B-742/B-743 |
| Type | Pen-style single-parameter ion meter |
| Measurement Principle | Solid-state ion-selective electrode (ISE) method |
| Nitrate (NO₃⁻) Range | 62–6,200 ppm (mg/L) [10⁻³–10⁻¹ mol/L] |
| Nitrate-nitrogen (NO₃⁻–N) Range | 14–1,400 ppm (mg/L) |
| Temperature Range | 5–40 °C |
| Temperature Compensation | Automatic (2 %/°C fixed coefficient) |
| Accuracy | ±10 % of reading |
| Resolution | 0.1 ppm (for NO₃⁻) |
| Calibration | Two-point calibration with standard solutions |
| IP Rating | IP67 |
| Power | Two CR2032 lithium batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Form Factor | Pen-type |
| Measurement Parameters | Conductivity (EC), TDS, Salinity, Temperature |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1 % (NaCl) |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. (conductivity), ±0.1 °C (temperature) |
| Resolution | 0.1 mS/cm, 0.1 ppm (TDS), 0.01 % (salinity), 0.1 °C |
| Temperature Compensation | Automatic, fixed 2 %/°C coefficient |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe tip) |
| Weight | Approx. 45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% NaCl |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. |
| Resolution | 0.1 (for conductivity, salinity, TDS, and temperature) |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excluding protrusions) |
| Weight | ~45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% (NaCl) |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Resolution | 0.1 (for conductivity, TDS, salinity, and temperature) |
| Measurement Principle | Two-electrode AC conductometric method |
| Sample Volume | ≥0.12 mL |
| Temperature Compensation | Fixed 2%/°C (linear, referenced to 25 °C) |
| Calibration | Two-point calibration (using standard KCl solutions) |
| Ingress Protection | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (L×W×H, excluding probe protrusion) |
| Weight | ~45 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Detection Parameter | Single (Conductivity) |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% NaCl |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Resolution | 0.1 mS/cm, 0.1 ppm, 0.01% NaCl, 0.1 °C |
| Calibration | Two-point (KCl standard solutions) |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | ~45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Detection Parameter | Single (Conductivity) |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% NaCl |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Resolution | 0.1 mS/cm, 0.1 ppm, 0.01% |
| Measurement Principle | Two-electrode AC method |
| Sample Volume | ≥0.12 mL |
| Temperature Compensation | Fixed 2%/°C |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm |
| Weight | ~45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% NaCl |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Resolution | 0.1 (for all primary parameters) |
| Measurement Principle | Two-electrode AC conductometry |
| Minimum Sample Volume | ≥0.12 mL |
| Temperature Compensation | Fixed 2%/°C |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | ~45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Resolution | 0.1 |
| Calibration | Two-point |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Measurement Principle | Two-Electrode AC Method |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% (NaCl) |
| Resistivity Range | Not applicable |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% FS ±1 digit (per range) |
| Resolution | 0.1 (for conductivity, TDS, salinity, temperature) |
| Temperature Compensation | Fixed 2%/°C |
| Calibration | Two-point calibration |
| Protection Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | Approx. 45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Portability | Pen-type |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Salinity Range | 0–1.1% |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Resolution | 0.1 |
| Calibration | Two-point |
| IP Rating | IP67 |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~45 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-771 |
| Detection Parameter | Single (Conductivity) |
| Portability | Pen-style |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Resistivity Range | Not applicable |
| Salinity Range | Not applicable |
| Temperature Range | 5–40 °C |
| Accuracy | ±2% F.S. ±1 digit |
| Minimum Resolution | 0.1 mS/cm |
| Measurement Principle | Two-electrode AC method |
| Sample Volume | ≥0.12 mL |
| Calibration | Two-point calibration |
| Temperature Compensation | Fixed 2%/°C coefficient |
| IP Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~45 g (instrument only) |
| Origin | Japan |
|---|---|
| Type | Imported Instrument |
| Model | CS-131 / CS-131C (with integrated cooler) |
| Measurement Principle | UV-Vis Absorption Spectrophotometry |
| Analyte | SC-1 solution (NH₃ / H₂O₂ / H₂O) |
| Response Time | ≈2 s (excluding fluid exchange & cooling time) |
| NH₃ Range Options | 0.00–1.00%, 0.00–3.00%, or 0.00–5.00% w/w |
| H₂O₂ Range Options | 0.00–5.00%, 0.00–7.00%, or 0.00–10.00% w/w |
| H₂O Range | 85.0–100.0% w/w |
| Repeatability | NH₃ ±0.15–±0.25%, H₂O₂ ±0.3%, H₂O ±1.5% |
| Operating Temp. | CS-131: 20–30°C |
| CS-131C | 20–80°C |
| Flow Rate | CS-131: 20–60 mL/min |
| CS-131C | 20–40 mL/min |
| Pressure | 0.10–0.20 MPa |
| Power Supply | DC 24 V ±10%, 2 A |
| Output Interfaces | RS-232C, 4–20 mA (dual-channel), open-collector digital outputs, opto-isolated parallel inputs |
| Dimensions (W×D×H) | CS-131: 205 × 329 × 269 mm |
| CS-131C | 291 × 329 × 269 mm |
| Weight | CS-131: ~11 kg |
| CS-131C | ~12 kg |
| Tubing | 3 mm OD / 2 mm ID (Nippon Pillar Super fittings) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | Adjustable from 1 to 64 nm |
| Optical Resolution | 1 nm |
| Detection Sensitivity | Single-Photon Counting |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 1–64 nm Adjustable |
| Spectral Resolution | 1 nm |
| Sensitivity | Single-Photon Counting |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Instrument Type | Transient Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1–64 nm |
| Resolution | 1 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.05 nm |
| Excitation Source | Pulsed Laser Diode / LED System |
| Lifetime Range | <5 ps – 1 s |
| Minimum Acquisition Interval | 1 ms |
| Dead Time | 10 ns |
| Standard Detector | Picosecond PPD Module |
| Optional NIR Detection | up to ~1700 nm |
| Spectral Coverage | 200–1600 nm (with aberration-corrected gratings) |
| Sample Volume | as low as 1 µL |
| Software | Lifetime analysis suite with ≥5-exponential fitting, FRET, anisotropy, and decay-associated spectra (DAS) modules |