Chemical Analysis Instruments
Filter
Showing 4021–4050 of 10742 results
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaHUB |
| Core Technology | Time-Correlated Single-Photon Counting (TCSPC) |
| Lifetime Range | 25 ps – 11 s (source-dependent) |
| Excitation Sources | 100 MHz Deltadiode ps-Laser, NanoLED, or SpectraLED |
| Detector | Picosecond Photon-Counting Detector |
| Integrated Platform | TCSPC-HUB Workstation |
| Optional Accessories | Monochromator for Time-Resolved Emission Spectra (TRES), Liquid Nitrogen Cryostat, 400 MPa High-Pressure Liquid Cell |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | DeltaPro |
| Dispersion Element | Grating |
| Slit Width / Spectral Bandpass | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Wavelength Accuracy | Not Specified |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Model | DS-71 |
| Measurement Parameters | Conductivity, Resistivity, Salinity, TDS, Temperature |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 100 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C |
| Accuracy | ±0.05% of full scale |
| Resolution | 0.001 (for primary parameters) |
| Measurement Principle | Dual-electrode AC excitation (2-electrode alternating current method) |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, ChP |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-71 |
| Form Factor | Benchtop |
| Conductivity Range | 0.00 mS/m – 199.9 S/m |
| TDS Range | 0.01 mg/L – 100 g/L |
| Resistivity Range | 0 – 1.999 MΩ·m |
| Salinity Range | 0 – 80 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.5% FS ±1 digit (conductivity/resistivity/salinity/TDS), ±0.1 °C ±1 digit (temperature) |
| Resolution | 0.05% FS (conductivity/resistivity), 0.01 mg/L (TDS), 0.01 ppt (salinity), 0.1 °C (temperature) |
| Data Storage | 999 measurements |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVI, ChP |
| Communication | USB port for PC connectivity and data export |
| Power Supply | AC adapter (100–240 V, 50/60 Hz), ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-72 |
| Form Factor | Benchtop |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 1000 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.5% F.S. ±1 digit (conductivity/resistivity/salinity/TDS), ±0.1 °C ±1 digit (temperature) |
| Resolution | 0.05% F.S. (conductivity/resistivity), 0.01 ppt (salinity), 0.01 mg/L (TDS), 0.1 °C (temperature) |
| Data Storage | 2000 measurements |
| Compliance | JIS Z 8806, USP <645>, EP 2.2.38, JP XVIII, ChP (Chinese Pharmacopoeia) General Chapter 0681 |
| Language Support | English, Japanese, Chinese, Korean |
| Power Supply | AC adapter 100–240 V, 50/60 Hz, ~9.8 VA |
| Weight | 700 g |
| Interfaces | USB port for PC communication and USB mass storage |
| GLP/GMP Features | Audit trail-capable data logging, user authentication support, calibration history with timestamped entries |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-72 |
| Form Factor | Benchtop |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 1000 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.05% F.S. |
| Resolution | 0.001 (unit-dependent) |
| Data Storage | 2000 sets |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, ChP |
| Language Support | English, Japanese, Chinese, Korean |
| Power Supply | AC adapter 100–240 V, 50/60 Hz |
| Power Consumption | ~9.8 VA |
| Weight | ~700 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-72 |
| Form Factor | Benchtop |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 1000 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.05% of Full Scale |
| Resolution | 0.05% of Full Scale |
| Data Storage | 2000 measurements |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, ChP |
| Connectivity | USB host/device, GLP/GMP-compliant data export |
| Language Support | English, Japanese, Chinese, Korean |
| Power | AC adapter 100–240 V, 50/60 Hz, ~9.8 VA |
| Weight | 700 g |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | Duetta |
| Wavelength Range (Excitation/Absorption) | 250–1000 nm |
| Wavelength Range (Emission) | 250–1100 nm |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Fluorescence Sensitivity (Water Raman SNR) | ≥6000:1 (350 nm excitation, 5 nm bandwidth) |
| Absorbance Accuracy | ≤±0.02 A |
| Absorbance Range | 0–2 A |
| Spectral Acquisition Rate | ≥510,000 nm/min |
| A-TEEM Mode Acquisition Time | ≤30 s |
| EEM 3D Scan Time | ≤1 s (configurable) |
| Light Source | 75 W Xenon Arc Lamp |
| Detector (Fluorescence) | CCD Array |
| Detector (Absorption) | Silicon Photodiode |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Detection Technology | Back-Illuminated CCD |
| Sensitivity (Water Raman S/N) | >6000:1 |
| Dispersion Element | Holographic Grating |
| Slit Width / Spectral Bandpass | Variable, software-controlled |
| Wavelength Accuracy | ±0.5 nm |
| Internal Correction | Automated primary and secondary inner-filter effect compensation |
| Core Technology | A-TEEM™ (Absorbance-Transmitted Excitation-Emission Matrix) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Optical Resolution | 1 nm |
| Sensitivity (Water Raman RMS) | 6000:1 |
| Wavelength Accuracy | ±1 nm |
| Dispersion Element | Grating |
| Detector | CCD |
| Measurement Modes | Simultaneous Fluorescence & Absorbance |
| A-TEEM™ Capability | Yes |
| Auto Inner-Filter Correction | Yes |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyRatioPro |
| Spectral Dispersion Element | Grating |
| Excitation Wavelength Control | Motorized Dual-Filter Wheel with Precision Filter Positioning |
| Maximum Wavelength Scanning Speed | 500 nm/s |
| Illumination Technology | DeltaRAM™ High-Speed Monochromatic Illumination System |
| Data Acquisition Engine | PAE (Precision Acquisition Engine) |
| Human Interface | WarpDrive™ Ergonomic Control Console |
| Primary Applications | Intracellular Ca²⁺, Na⁺, and pH Ratiometric Imaging |
| Brand | HORIBA |
|---|---|
| Origin | Imported |
| Manufacturer | HORIBA, Ltd. |
| Model | EMGA-Expert |
| Detection Principle | Pulse Heating Extraction + NDIR (CO/CO₂, H₂O) & TCD (N₂) |
| Gas Detection Methods | Non-Dispersive Infrared (NDIR) for O and H |
| Automation Options | Auto-Sampler, Auto-Crucible Loader, Auto-Electrode Cleaner, Halogen Trap |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22356, JIS G 1257, USP <233>, FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready software architecture |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | EMIA-Expert |
| Pricing | Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace |
| Maintenance Interval | Up to 200 Analyses Without Service |
| Analysis Time | ≤70 Seconds per Sample |
| 清扫 Mechanism | Brushless Automatic Cleaning System |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | EMIA-Pro |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Measurement Range | C: 0.0002–6.0 wt% |
| S | 0.0002–1.0 wt% |
| Sensitivity | C: 0.01 ppm |
| S | 0.01 ppm |
| Accuracy | C: ±1 ppm or ±1.0% RSD |
| S | ±1 ppm or ±1.5% RSD |
| Analysis Time | 40 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Measurement Parameters | Conductivity, Resistivity, TDS, Salinity, Temperature |
| Conductivity Range | 0–200 S/m (configurable via cell constant: 0.000 mS/m–199.9 S/m) |
| TDS Range | 0.01 mg/L–100 g/L |
| Resistivity Range | 0.000 Ω·m–1.999 MΩ·m |
| Salinity Range | 0.00–80.00 ppt |
| Temperature Range | 0.0–100.0 °C (extended to −30.0–130.0 °C with optional probe) |
| Accuracy | ±0.5% of full scale |
| Resolution | 0.05% F.S. for conductivity/resistivity/salinity/TDS |
| Temperature Resolution | 0.1 °C |
| Repeatability | ±0.5% F.S. ±1 digit (conductivity/resistivity) |
| Data Storage | 999 measurement records |
| Compliance | JIS Z 8806, USP <645>, EP 2.2.38, JP XVI, CP 2020 Chapter 0903 |
| Connectivity | USB port for PC communication and data export |
| Power Supply | AC adapter (100–240 V, 50/60 Hz), ~0.7 VA |
| Weight | ~500 g |
| Display | Capacitive touchscreen (full graphical interface) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EV 2.0 |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Dynamic Range | >3000:1 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F-50 |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 Series |
| Instrument Type | Benchtop |
| Parameter Types | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution & Accuracy | 0.001 |
| Calibration Buffers | pH 4.01, 7.00, 9.21 |
| Measurement Principle | Glass Electrode (pH), Ion-Selective Electrode (ISE), AC Two-Electrode Conductometry (Conductivity) |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Data Storage | Up to 2000 datasets (F-72/F-73/F-74) |
| Connectivity | USB host/device, optional thermal printer interface |
| Display | Capacitive touchscreen (F-74BW), multilingual UI (English, Japanese, Chinese, Korean) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Parameter Channels | Dual (pH/ORP + Ion/Temp) |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.01 |
| pH Repeatability | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV |
| Ion Concentration Range | 0.00 µg/L – 999 g/L (mol/L basis) |
| Ion Resolution | 3 significant digits |
| Ion Repeatability | ±0.5% F.S. |
| Temperature Range | −30.0 to 130.0 °C |
| Temp Resolution | 0.1 °C |
| Temp Repeatability | ±0.1 °C |
| Calibration Buffers | pH 4.01, 7.00, 9.21 |
| Data Storage Capacity | 2000 measurements |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC Adapter 100–240 V, 50/60 Hz |
| Power Consumption | ~9.8 VA |
| Net Weight | 700 g |
| Compliance | JIS Z 8802, USP <791>, EP 2.2.3, JP XVI, GLP/GMP-ready data logging and audit trail support |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FHR1000 |
| Application System | Universal |
| Grating Mount | Dual-Grating Turret |
| Spectral Resolution | 0.010 nm |
| Dispersion | 0.8 nm/mm |
| F-number | f/9.0 |
| Focal Length | 1000 mm |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Maximum Scanning Speed | >300 nm/s |
| Grating Dimensions | Single grating: 110 mm × 110 mm |
| Dual-grating configuration | 80 mm × 110 mm each |
| Stray Light | <1×10⁻⁶ (typical, per ISO 14785) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | FHR640 / FHR1000 |
| Focal Length | 640 mm (FHR640) / 1000 mm (FHR1000) |
| f-number | f/5.4 (FHR640) / f/9.0 (FHR1000) |
| Spectral Resolution | 0.016 nm (FHR640) / 0.010 nm (FHR1000) |
| Spectral Dispersion | 1.2 nm/mm (FHR640) / 0.8 nm/mm (FHR1000) |
| Grating Size | 110 × 110 mm (single) / 80 × 110 mm (dual) |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scan Speed | >300 nm/s |
| Optical Design | Monolithic cast aluminum body with in-axis grating scanning mechanism |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | FHR640/FHR1000 |
| Focal Length | 640 mm (FHR640) / 1000 mm (FHR1000) |
| f-number | f/5.4 (FHR640) / f/9.0 (FHR1000) |
| Spectral Resolution | 0.016 nm (FHR640) / 0.010 nm (FHR1000) |
| Linear Dispersion | 1.2 nm/mm (FHR640) / 0.8 nm/mm (FHR1000) |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scanning Speed | >300 nm/s |
| Grating Mount | Dual-grating turret (up to two 110×110 mm or 80×110 mm gratings) |
| Output Ports | Dual simultaneous exit ports |
| Structural Design | Monolithic aluminum cast housing |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3573-10C |
| Cell Constant | 1000 m⁻¹ (10 cm⁻¹) |
| Conductivity Range | 1 mS/cm to 100 S/cm (10 μS/cm to 1 S/cm) |
| Minimum Sample Volume | 4 mL |
| Operating Temperature Range | 0–60 °C |
| Electrical Connection | BNC or DIN-compatible analog output |
| Material | Platinum electrodes, PEEK body, EPDM or Viton O-rings (standard configuration) |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Fluorolog-QM |
| Wavelength Range | 180–5500 nm |
| Spectral Resolution | < ±0.1 nm |
| Sensitivity | > 35,000:1 (Water Raman S/N) |
| Wavelength Accuracy | < ±0.1 nm |
| Monochromator Type | Reflective Czerny-Turner |
| Focal Length | 350 mm (single stage), 700 mm (dual stage) |
| Stray Light Rejection | 1×10⁻⁵ (single), 1×10⁻¹⁰ (dual) |
| Grating Options | >30 selectable gratings |
| Slit Control | Motorized, step resolution down to 0.01 nm |
| Light Sources | Up to 4 simultaneously controlled (Xe arc, pulsed LEDs, lasers, OPOs) |
| Detectors | Up to 6 concurrently addressable (PMT, NIR PMT, InGaAs, InAs, InSb) |
| Lifetime Techniques | TCSPC (5 ps – ∞), MCS, SSTD (1 µs – seconds), gated detection |
| Software Platform | FelixFL v5.x with FDA 21 CFR Part 11 compliance mode |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | FluoroLog-QM |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersion Elements | Dual-grating monochromator with motorized filter wheels |
| Spectral Slit Width (Spectral Bandpass) | 0.01 nm |
| Optical Resolution | 0.1 nm |
| Sensitivity (Water Raman SNR) | 35,000:1 |
| Wavelength Accuracy | ±0.3 nm |
| Excitation Sources | Continuous Xenon lamp, Pulsed Xenon lamp, CW and Pulsed Lasers (210–2200 nm coverage via modular coupling) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FluoroMax Plus |
| Dispersion Element | Holographic Grating |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm, Motorized & Computer-Controlled |
| Sensitivity | >16,000:1 (RMS Method) |
| Wavelength Accuracy | ±0.5 nm |
| Optical Design | All-Reflective Czerny–Turner Monochromator |
| Excitation Source | 150 W Ozone-Free Xenon Arc Lamp (Vertically Mounted) |
| Reference Detector | Stabilized Silicon Photodiode |
| Detection Mode | Photon Counting PMT with Optional TCSPC Upgrade Capability |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluoroMax+ |
| Price Range | USD 42,000–70,000 (FOB) |
| Dispersive Element | Plane Grating |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Spectral Resolution | 0.02–200 nm |
| Sensitivity | >16,000:1 (RMS Method) |
| Wavelength Accuracy | ±0.5 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FluoroMax+ |
| Dispersion Element | Holographic Grating |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0.05–30 nm |
| Spectral Resolution | ≤0.2 nm |
| Sensitivity (S/N Ratio) | >16,000:1 (water Raman, 5 nm bandwidth, 1 s integration, no order-sorting filters) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | 150 W Ozone-Free Xenon Lamp, Flash Xenon Lamp, Pulsed Laser Options |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GD Profiler 2 |
| Pricing | Available Upon Request |