| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx |
| Instrument Type | Floor-standing |
| Excitation Source | Spark Discharge |
| Detector | Charge-Coupled Device (CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | User-configurable |
| Number of Channels | User-configurable |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx08 |
| Excitation Source | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | User-configurable |
| Number of Channels | Not applicable (Full-spectrum CCD-based system) |
| Instrument Form Factor | Floor-standing |
| Application Domain | Metal & Foundry Quality Control, Incoming/Outgoing Material Inspection, Process Monitoring |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SPECTROPORT |
| Instrument Type | Portable / Field-Deployable |
| Excitation Method | Spark Discharge |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 300 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 178–530 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Number of Channels | Unlimited |
| Power Supply | Rechargeable Battery (up to 800 measurements per charge) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTRO TEST |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Spectral Coverage | Full-Spectrum (Echelle + Prism Cross-Dispersion) |
| Price Range | USD 52,000–65,000 (FOB Hamburg) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | XEPOS Polarized |
| Instrument Type | Polarized ED-XRF |
| Configuration | Benchtop/Floor-standing |
| Regulatory Compliance | CE, RoHS, ISO/IEC 17025 compatible (when operated under GLP/GMP conditions) |
| Software | TurboQuant II with ASTM E1621, ISO 21043, and USP <233> method support |
| Detector | High-resolution silicon drift detector (SDD), >140 eV Mn Kα resolution |
| Excitation Source | Dual-target polarized X-ray tube (Mo/Rh), variable kV/mA control |
| Multi-layer Analysis Capability | Up to 8 layers, 55 elements simultaneously quantifiable |
| Detection Limits | Sub-ppm for heavy metals in polymer matrices |
| Sample Forms | Solids (flat, irregular, coated), powders (pressed pellets), liquids (in sealed cells) |
| Data Security | FDA 21 CFR Part 11 compliant audit trail, electronic signature, role-based access control |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO XEPOS |
| Configuration | Benchtop/Floor-standing |
| Application Scope | Universal |
| Elemental Range | Na to U (11–92) |
| Quantification Range | 0.1 ppm – 100 wt% |
| Energy Resolution | <130 eV (Mn Kα) |
| Detector | High-resolution Peltier-cooled Silicon Drift Detector (SDD) |
| Maximum Count Rate | 1,000,000 cps |
| Coating Analysis | Up to 8 layers, down to 1 nm thickness, 55 elements supported |
| Software Platform | Windows-based SPECTRO XRF Suite with TURBOQUANT, FP, Compton Normalization, Lucas-Tooth, α-empirical, MAC, and Average Atomic Number correction models |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | XEPOS |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit Improvement | Up to 3× lower vs. prior-generation ED-XRF |
| Analytical Range | Sub-ppm to 100% w/w |
| Repeatability | < 0.1% RSD (at mid-range concentrations) |
| Energy Resolution | < 130 eV (Mn Kα) |
| Excitation Mode | Polarized, Single-Wavelength (Monochromatic) Secondary Target Excitation |
| Software Platform | TurboQuant II |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO xSORT |
| Portability | Handheld / Field-Deployable |
| Detection Range | Mg (12) to U (92) |
| Display | 5-inch HD touchscreen |
| Operating System | Android-based embedded OS |
| Connectivity | Wi-Fi, Bluetooth, USB, MicroSD |
| Integrated Sensors | GPS, dual cameras |
| Ergonomics | Glove-compatible physical buttons, low-force trigger, balanced weight distribution |
| Compliance | Meets ISO 12847, ASTM E2865, and EU RoHS/WEEE screening requirements |
| Software Platform | XRF Analyzer Pro (PC-based, supports audit trail, method management, and GLP-compliant reporting) |
| Sample Handling | Compatible with portable sample chamber and docking station for lab-grade repeatability |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Type | Handheld/Portable |
| Model | xSORT |
| Element Range | Mg–U (47 elements) |
| Detection Limit | 7 ppm |
| Concentration Range | 7 ppm – 99.99% |
| Energy Resolution | 140 eV (at Mn Kα) |
| Repeatability | ≤ 0.1% RSD |
| Safety Compliance | EN 62471, IEC 61010-1, EU RoHS Directive |
| Weight | 1.64 kg (3.62 lb) |
| Dimensions (H×W×D) | 270 × 93 × 230 mm |
| Light Element Analysis | Mg, Al, Si, P in air |
| Analysis Time | 2–60 s |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | xSORT |
| Type | Handheld ED-XRF Spectrometer |
| Safety Compliance | CE, IEC 62471, EN 61000-6-3/6-4 |
| Regulatory Conformance | RoHS/WEEE Compliant, ASTM E2857, ISO 21043, USP <232>/<233> for Elemental Impurities |
| Detection Range | Mg (12) to U (92) |
| Light Element Capability | Mg, Al, Si, P analyzed in air |
| Typical Analysis Time | 2–60 s |
| Sample Form | Solids, powders, soils, sludges, filters, thin films, alloys, ores |
| Calibration | Built-in ICAL self-calibration reference |
| Data Storage | Onboard memory with timestamp, GPS coordinates, and CCD image capture |
| Software | SPECTRO XRF Analyzer Suite (supports GLP/GMP audit trails, 21 CFR Part 11 optional modules) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO xSORT XHH04 |
| Application | Field-Portable Elemental Analysis |
| Element Range | Na (11) to U (92) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Operating System | Android-based Custom Firmware |
| Display | 5-inch Wide-Angle HD Touchscreen |
| Connectivity | Wi-Fi, Bluetooth 5.0, USB-C, microSD Slot |
| Optional Modules | Integrated GPS, Dual-Camera Imaging System (Sample Positioning + Test Area Documentation), Docking Station for Lab-Grade Expansion |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROBLUE |
| Optical System | Paschen-Runge mount with 750 mm focal length |
| Detectors | 15 linear CCD arrays |
| Software | SPECTRO’s SMART ANALYSIS VISION |
| Compliance | Designed for ASTM D1976, ISO 11885, EPA Methods 200.7 & 200.8, EN 16173 |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROCHECK LMM02 |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTROGREEN |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb |
| Precision (RSD) | <1.5% |
| Long-Term Stability (RSD) | <0.5% |
| Wavelength Range | 165–770 nm |
| Optical Resolution | 0.007 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTROGREEN MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range | 4–255 amu |
| Unit Mass Resolution | 0.2–0.66 amu |
| Detection Limit | Sub-ppt (ng·L⁻¹) |
| Sensitivity | Co ≥ 360 Mcps/(mg·L⁻¹), Y ≥ 400 Mcps/(mg·L⁻¹) |
| Short-Term Stability (RSD) | <1% |
| Long-Term Stability (RSD) | <2% |
| Brand | Spectrolight |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SP-FL |
| Price Range | USD 14,000–28,000 (approx.) |
| Dispersive Element | Grating and Interference Filters |
| Spectral Bandwidth (Slit) | 6–15 nm |
| Resolution | 62,500 (SP-FL-245) / 600,000 (SP-FL-303) / 200,000 (SP-FL-642) |
| Sensitivity | 62,500 (SP-FL-245) / 600,000 (SP-FL-303) / 200,000 (SP-FL-642) |
| Wavelength Accuracy | ±1% of reading |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | SPECTRONIC 200 |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 340 nm – 1000 nm |
| Wavelength Scanning | Motorized Auto-wavelength Selection |
| Spectral Bandwidth | < 4 nm |
| Wavelength Accuracy | ±1.0 nm (typical, per ASTM E275) |
| Stray Light | < 0.1% T at 340 nm (as measured per ISO 9050) |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SpectroSense2 |
| Price | Upon Request |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | TEST |
| Instrument Type | Portable / Mobile |
| Excitation Source | Spark |
| Detector | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 185–520 nm |
| Spectral Coverage | Full-Spectrum |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Brand | Spectrum |
|---|---|
| Origin | USA |
| Model | 2266FS |
| Portability | Portable |
| Conductivity Ranges | 0.0–200.0 µS/cm |
| Resolution | 0.1 µS/cm |
| Accuracy | ±1% of full scale |
| Temperature Range | 0–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C (0–50 °C), ±1.0 °C (50–60 °C) |
| Automatic Temperature Compensation (ATC) | Yes |
| Ingress Protection | IP67 |
| Power | 4 × AAA 1.5 V batteries |
| Battery Life | >150 hours |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 6000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Long-Term Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EXPEC 7200 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 1–280 |
| Resolution (Unit Mass Resolution, amu) | ≤0.75 |
| Detection Limit (ng·L⁻¹) | <0.05 for ⁹Be, <0.003 for ²³⁸U |
| Sensitivity (Mcps/mg·L⁻¹) | >350 for ²³⁸U |
| Short-Term Stability (RSD, 10 min) | <2% |
| Long-Term Stability (RSD, 2 h) | <3% |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 650 / GDA 150 |
| Pricing | Available Upon Request |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA 750 / GDA 550 |
| Detection Principle | Glow Discharge Optical Emission Spectroscopy (GD-OES) |
| Spectral Range | 190–800 nm (standard PMT system) |
| Spectral Resolution | <20 pm FWHM (PMT) |
| Optical System | Paschen-Runge mount, 750 mm focal length, holographically ruled grating (2400 lines/mm) |
| Max. Analytical Depth | >200 µm |
| Depth Resolution | ≤1 nm |
| Elemental Coverage | H, O, N, Cl, C, and all elements from Li to U |
| Detection Limits | Sub-ppm (matrix-dependent) |
| Sputter Diameter | 1–8 mm (adjustable, same source) |
| DC Source | Up to 1500 V, 250 mA, fully programmable |
| RF Source | Up to 150 W, pulsed mode optional (GDA 750 only) |
| Sample Thickness Range | 50 µm – 45 mm |
| Vacuum System | Dual-stage rotary vane pump (<50 dB), oil-free pump for source chamber |
| Optional Accessories | High-resolution CCD optical system, RF pulse generator, load-lock transfer chamber, 100-position autosampler, monochromator with triple-grating turret |
| Brand | SPECTRUMA |
|---|---|
| Country of Origin | Germany |
| Model | GDA 750 / GDA 550 |
| Optical Resolution | <20 pm (FWHM) |
| Spectral Range | 190–800 nm (PMT), 200–800 nm (CCD option) |
| Maximum Analysis Depth | >200 µm |
| Depth Resolution | ≤1 nm |
| Detection Limits | Sub-ppm |
| Excitation Source | DC (0–1500 V, 0–250 mA), RF (up to 150 W, pulsed mode optional for GDA 750) |
| Sample Diameter Range | 1–8 mm |
| Vacuum System | Dual-stage rotary vane pump (oil-free for source), optional turbomolecular pump |
| Software Platform | WinGDOES (Windows XP or later) |
| Weight | ~580 kg |
| Dimensions | 1380 × 1440 × 890 mm |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA 750 HR |
| Detection Range | H–U (76 elements) |
| Detection Limit | sub-ppm level |
| Depth Resolution | nanometer-scale to several hundred micrometers |
| Quantitative Precision | RSD < 2% (content), RSD < 5% (depth) |
| Sample Types | conductive & non-conductive solids (flat, curved, thin-film, air-sensitive layers) |
| Compliance | ISO/IEC 17025-ready architecture, GLP-compatible data handling |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 750 HR |
| Price Range | USD 195,000 – 260,000 |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDA Alpha |
| Pricing | Upon Request |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA150 HR |
| Detector Type | Thermally Stabilized CCD |
| Light Element Capability | C, N, H (O optional) |
| Sample Type | Conductive solids only |
| Application Scope | Depth profiling, surface diffusion analysis, coating & plating evaluation, hard coating characterization |