Chemical Analysis Instruments
Filter
Showing 8371–8400 of 10669 results
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | UV2800PC |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05%T at 220 nm and 360 nm |
| Display | 320×240 LCD (6-inch) |
| Software | UV-Solution 3.0 |
| Compliance | ASTM E275, ISO 6223, USP <857>, GLP-ready audit trail support |
| Brand | SOTAX |
|---|---|
| Model | CE 7smart |
| Apparatus Type | USP <724> Apparatus 4 (Flow-Through Cell) |
| Compliance | USP <711>, <1088>, Ph. Eur. 2.9.3, 2.9.42, 2.9.43, JP Dissolution Test Method 3 |
| Temperature Control Range | Ambient – 45 °C (±0.2 °C) |
| Flow Rate Range | 1.5–35 mL/min (with CP 7-35 piston pump) |
| Cell Capacity | 6 positions |
| Bath Volume | 8 L |
| Dimensions (H×D×W) | 470 × 600 × 580 mm |
| Weight | 36 kg |
| Software | WinSOTAX (21 CFR Part 11 compliant, client-server architecture supported) |
| Sample Handling | Online UV/Vis/UV-FO coupling or offline fraction collection for HPLC analysis |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | H2S-725 |
| Explosion Protection | Class 1, Div 1, Groups B, C, D |
| Measurement Range | 0–200 ppm or 0–2000 ppm H₂S |
| Accuracy | ±2% FS |
| Output | 4–20 mA |
| Power Supply | 12–24 V DC |
| Current Draw | 50 mA |
| Response Time (T90) | <60 s |
| Sample Flow Rate | 0.25–5.0 SCFH |
| Inlet Pressure | 0.1–50 PSIG |
| Operating Temperature | 0–50 °C |
| Enclosure Dimensions | 15.25" × 12.5" × 5.25" |
| Weight | 18.5 lb |
| Sensor Type | Electrochemical fuel cell (current-based) |
| Calibration Interval | Recommended every 1–3 months |
| Warranty | 12 months (sensor and electronics) |
| Gas Connection | 1/4" Swagelok |
| Interference Response | Methyl mercaptan (40%), SO₂ (18%) |
| Optional Features | Heated enclosure, custom range configuration, sampling system integration, bidirectional RS485 communication |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | MOMD480, MOMD525 |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Range Options | 0–1%/5%/10%/25%/100% (MOMD480) |
| Accuracy | ±1% FS |
| Display | Backlit Color LCD |
| Enclosure Rating | IP66 / NEMA 4X |
| Output | Dual Adjustable Relay Alarms (MOMD525) |
| Operating Environment | Inert, N₂, H₂, CO₂-containing, or mixed gas matrices |
| Compliance | CE, Class I, Div. 1, Groups B, C, D (MOMD625 variant) |
| Brand | Southland Sensing |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −20 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Display | Touchscreen with optional Chinese language interface |
| Output Signals | 4–20 mA (configurable), High/Low alarm relay outputs |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Intrinsic Safety | Integrated Zener barrier compliant with IEC/EN 60079-11 for hazardous area use |
| Brand | SP (Spectral Products) |
|---|---|
| Origin | USA |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Optical Resolution | 0.15–10 nm (FWHM, configuration-dependent) |
| Stray Light | <0.05% at 632 nm (<0.1% across full range) |
| Sensitivity | High quantum efficiency (QE >60% typical in 350–800 nm) |
| Signal-to-Noise Ratio | ≥300:1 (full well, 1 s integration) |
| Dynamic Range | >10,000:1 (with 16-bit digitization and on-board baseline correction) |
| Brand | SP/Spectral Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SM301 |
| Spectral Range | 1.0–5.0 µm |
| Detector Type | Thermoelectrically Cooled PbS/PbSe Linear Array |
| Resolution | 30 nm |
| Sensitivity | High |
| Signal-to-Noise Ratio | High |
| Dynamic Range | High |
| Stray Light | < 0.1% |
| Pixel Count | 256 elements |
| Readout Rate | Up to 2 MHz |
| Cooling | Peltier-cooled to –4 °C |
| Software | SM32Pro (Windows-based) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-1920 |
| Optical Design | Dual-beam, spatially separated, asymmetric vertical optical path |
| Detector Type | Digital dual high-performance photodiodes |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm (typical) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05% T at 220 nm (NaI) and 340 nm (NaNO₂) |
| Display | 8-inch color capacitive touchscreen |
| Light Sources | 6V/10W halogen lamp (2000 h lifetime), deuterium lamp (1000 h lifetime) |
| Sample Compartment | Fixed 100 mm pathlength cuvette holder |
| Power Supply | 110/220 VAC, 50/60 Hz, ±10% |
| Dimensions (W×D×H) | 655 × 420 × 265 mm |
| Compliance | Meets ISO 9001 manufacturing standards |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | SP-2020 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Up to 400 °C |
| Temperature Ramp Rate | 0.1–50 °C/min |
| Oven Cooling Rate | 0.1–50 °C/min |
| Carrier Gas Flow Control Range | 0–600 kPa |
| Carrier Gas Pressure Control Range | 0–600 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–600 kPa |
| Injector Total Flow Setting Range | 0–100 / 200 / 500 mL/min (selectable) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SP-2100A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 20 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Rate | 400 °C → 20 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD |
| TCD Sensitivity | ≥5000 mV·mL/mg n-C₁₆ |
| FID Detection Limit | ≤1×10⁻¹¹ g/s |
| ECD Detection Limit | ≤4×10⁻¹³ g/s (α-HCH) |
| FPD [P] Detection Limit | ≤5×10⁻¹² g/s (parathion) |
| FPD [S] Detection Limit | ≤1×10⁻¹⁰ g/s (parathion) |
| Column Oven Programmable Steps | 5-stage ramp |
| Injector Configurations | Dual packed-column injectors + 1 capillary injector |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz, 15 A |
| Dimensions (W×D×H) | 445 × 550 × 560 mm |
| Net Weight | ~38 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | SP-3400 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 4°C to 450°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0.1–1200 mL/min |
| Carrier Gas Pressure Range & Control | ±0.05 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | ±0.05 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 methods |
| Key Features | Real-time self-diagnosis, programmable detector range/attenuation, automated valve & signal switching, multi-safety interlocks (TCD flow failure, overtemperature, FPD light leakage), microprocessor-based full-keyboard interface |
| [Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3882AAS |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp, Self-absorption, and Transverse Zeeman Effect |
| Atomizer Configuration | Integrated Flame-GF Platform (No Mechanical Switching Required) |
| Burner Head | Titanium Alloy |
| Nebulizer | High-efficiency Glass Nebulizer with Optional Ceramic Upgrade |
| Graphite Furnace | Longitudinally Heated with Transverse Magnetic Field |
| Lamp System | 8-position Automatic Lamp Carousel |
| Lamp Control | Gap-controlled Hollow Cathode Lamp Power Supply |
| Safety Features | Graphite Tube Purge Gas Flow Monitoring with Auto-alarm and Interlock] |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-I |
| Instrument Category | TLC Sample Spotter |
| Spotting Uniformity | < 0.2 mm |
| Maximum Plate Size | 200 mm × 200 mm |
| Spotting Mechanism | Capillary or Microsyringe-Based Manual Deposition |
| Plate Protection Feature | Non-penetrating Tip Design |
| Compliance | Designed for GLP-aligned manual sample preparation workflows |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP1-12012 Self-Adhesive Quartz Crystal Holder |
| Pricing | Upon Request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP1-24018 Self-Adhesive Quartz Crystal Carrier Box |
| Pricing | Upon Request |
| External Dimensions | 240 mm × 120 mm × 18 mm |
| Internal Dimensions | 235 mm × 115 mm × 13 mm |
| Lid/Bottom Height | 9 mm / 9 mm |
| Adhesion Strength | Selectable Low or High |
| Material | Ultra-Clean Polymer Adhesive Layer + Rigid Polycarbonate Housing |
| Optical Transparency | Fully Transparent or Black Opaque Variant Available |
| Compatibility | Standard AT-cut quartz crystal resonators (5–14 mm diameter), SAW/BAW substrates, and thin-film sensor wafers |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP1-8512 Self-Adhesive Quartz Crystal Holder |
| Pricing | Upon Request |
| Dimensions (OD) | 85 mm × 85 mm × 12 mm |
| Dimensions (ID) | 81 mm × 81 mm × 8.5 mm |
| Lid/Bottom Height | 6 mm each |
| Adhesion Strength | Low or High Option |
| Transparency | Clear or Black Variant |
| Material | High-Purity Polymer Adhesive Layer + Rigid Polypropylene Housing |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP3-3818 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP6900 |
| Pricing | Available Upon Request |
| Temperature Control | 5-Channel Independent Zones |
| Oven Temperature Range | Ambient +15°C to 399°C |
| Temperature Accuracy | Better than ±0.1°C |
| Ramp Rate | 0.1–40°C/min |
| Programmed Temperature Steps | Up to 5 stages |
| Hold Time Range | 0–255 min per step |
| TCD Detector Sensitivity | ≥3500 mV·mL/mg |
| Baseline Noise | ≤0.02 mV |
| Drift | <0.1 mV/h |
| Instrument Weight | ~60 kg |
| Sample Introduction | Six-Port Rotary Valve |
| Data Output | Real-time digital display of LPG composition and purity via integrated PC software |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Alias |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 48 × 2 mL vials (2 racks) |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 100 µL (optional up to 10 mL) |
| Positioning Accuracy | < 0.4 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external needle wash with pressurized headspace purge |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPH1299 |
| Instrument Type | Binary HPLC Pump |
| Maximum Pressure | 18,850 psi (130 MPa) |
| Flow Rate Range | 1–4000 µL/min |
| Flow Precision | ≤ 0.075 % RSD (at 200–2000 µL/min) |
| Flow Accuracy | ±1 % (at 200–2000 µL/min) |
| Gradient Delivery Capability | Dual-solvent binary gradient with active compressibility compensation |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Model | UHPLC Spark |
| Instrument Type | Ultra-High-Performance Liquid Chromatography–Online Solid-Phase Extraction (UHPLC–SPE) System |
| Flow Rate Range | 1–4000 µL/min |
| Maximum Pressure | 18,850 psi |
| Flow Precision | ≤ 0.075 % RSD (at 200–2000 µL/min) |
| Flow Accuracy | ±1 % (at 200–2000 µL/min) |
| Sample Tray Capacity | 96 positions × 1.5 mL vials |
| Injection Volume Range | 1–10,000 µL |
| Column Oven Temperature Range | 5–90 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Kunyuan Instruments |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | Sparkle |
| Price Range | USD 810,000 – 910,000 (based on exchange rate of ¥1 = USD 0.14) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | SpeBOX-1 |
| Form Factor | Benchtop/Floor-standing |
| Instrument Type | Conventional EDXRF |
| Application Scope | Universal |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | ppm-level |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SPEC Pro 6000 |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Safety Integration | Integrated Glovebox System |
| RF Generator Architecture | Separated Solid-State RF Source |
| Optical System | Echelle Grating with Thermally Stabilized Optics |
| Detector | Back-Illuminated High-Speed CCD with Anti-Blooming Design |
| RF Power Range | 700–1600 W (Continuously Adjustable) |
| RF Cooling | Water-Cooled |
| Power Stability | <0.1% |
| Gas Control | Multi-Channel Digital Mass Flow Controllers (Accuracy: ±0.01 L/min) |
| Nebulization System | 12-Rotor, 4-Channel Peristaltic Pump with Optional Internal Standard/Standard Addition Capability |
| Torch Design | Modular, Self-Aligning, Center-Tube-Replaceable Echelle Torch |
| Software Platform | Element V (Fully Localized Chinese Interface with GLP-Compliant Audit Trail) |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Quadrupole ICP-MS |
| Configuration | Integrated Glovebox-Coupled System |
| Application Environment | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO/IEC 17025 method validation frameworks |
| Sample Handling | Fully enclosed, operator-isolated glovebox integration (vacuum/negative-pressure/ultra-clean operation) |
| Matrix Tolerance | Direct analysis of up to 10% total dissolved solids (TDS) |
| Detection Limit | Sub-ppt (ng/L) for key isotopes under optimized conditions |
| Ion Source | Self-excited all-solid-state RF generator with argon plasma stabilization |
| Interface Design | Aerodynamically optimized ion optics at plasma–vacuum boundary |
| Collision/Reaction Cell | Integrated dynamic reaction cell (DRC) with multi-gas capability (He, H₂, NH₃, O₂) |
| Automation Readiness | Compatible with EXPEC automated inorganic sample preparation platforms |
| Brand | SPEC (Beijing Spark) |
|---|---|
| Origin | Beijing, China |
| Model | SPEC-3015V |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Sample Compatibility | Solid–Liquid Dual-Phase Core Samples |
| Operating Mode | Pulsed Fourier Transform (PFT) |
| Magnet Bore Diameter | 300 mm |
| Field Strength Range | 0.05–1.5 T (Tunable) |
| Maximum Operating Temperature | 150 °C |
| Maximum Confining Pressure | 100 MPa |
| Supported Nuclei | ¹H, ²³Na, ¹⁹F, ¹³C |
| Cryogen Requirement | Cryogen-Free (Zero-Liquid-Helium) |
| Brand | Specac |
|---|---|
| Origin | United Kingdom |
| Model | Atlas |
| Max Operating Temperature | 300 °C or 400 °C |
| Adjustable Film Thickness | 15, 25, 50, 100, 250, 500 µm |
| Sample Diameter | 29 mm |
| Configuration Options | Standalone press unit (15631/15800) or integrated press + manual 15-ton hydraulic press (15633/15810) |
| Compliance | Designed for ASTM E1252, ISO 18381, and USP <1118> FTIR sample preparation |
| Brand | Specim (Finland) |
|---|---|
| Origin | Finland |
| Model | AFX10 / AFX17 |
| Spectral Range | AFX10 — 400–1000 nm (Vis-NIR), AFX17 — 900–1700 nm (NIR) |
| Spatial Resolution | Up to 1280 pixels across track |
| Frame Rate | Up to 300 fps (configurable) |
| Integration | GNSS/IMU-aided georeferencing |
| Platform Compatibility | UAVs (multirotor, fixed-wing), light aircraft |
| Onboard Processing | Embedded real-time data acquisition & preprocessing unit |
| Data Output Format | ENVI-compatible raw and radiometrically calibrated cubes (.bil/.hdr) |
| Weight | < 2.5 kg (full integrated system) |
| Brand | Specim (a Konica Minolta company) |
|---|---|
| Origin | Japan |
| Model | Specim AFX Series |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5.5 nm |
| Platform Compatibility | UAV-mounted (multirotor & fixed-wing) and ground-based operation |
| Integration | Integrated GNSS/IMU, onboard computing unit, FX-series hyperspectral camera |
| Software Compatibility | Specim CaliGeo PRO, ENVI, PCI Geomatica, QGIS (with appropriate plugins) |
| Data Output Format | Radiometrically calibrated, georeferenced ENVI-compatible .hdr/.raw files |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | AISA |
| Imaging Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and airborne (fixed-wing, rotary-wing, manned & unmanned aircraft) |
| Spectral Range | 400–1000 nm (VNIR), 600–1600 nm (VNIR-SWIR overlap), 400–2500 nm (full VNIR-SWIR), 7.7–12.3 µm (LWIR) |
| Spectral Resolution | 1.75 nm / 3.5 nm / 7 nm (VNIR), 10 nm / 15 nm (SWIR), 100 nm (LWIR) |
| Spatial Pixels | 2048 (VNIR), 384–1024 (SWIR variants), 616 (LWIR) |
| Field of View (TFOV) | 32° |
| Instantaneous Field of View (IFOV) | Height-dependent |
| Frame Rate | ≥100 fps |