Chemical Analysis Instruments
Filter
Showing 8581–8610 of 10347 results
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Sensor Types | Tubular, Planar, Fork-Type, TipTop & Custom Configurations |
| Application Scope | Laboratory QC, In-Line Process Monitoring, Batch Sampling |
| Material Compatibility | Powders, Granules, Tablets, Sheets, Fibers, Pellets, Non-Adhesive Bulk Solids |
| Construction | Stainless Steel (AISI 316L) + High-Strength Alumina Ceramic |
| Interface | Analog 4–20 mA / Digital RS-485 / EtherNet/IP (compatible with TEWS MW-E Series Electronics, excluding MW-T) |
| Compliance | CE, RoHS, ATEX Zone 22 (optional), ISO/IEC 17025 traceable calibration support |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW3012 |
| Measurement Principle | Microwave Absorption Spectroscopy (2.45 GHz) |
| Moisture Range | 10 ppm – 20 wt% |
| Sampling Rate | Up to 40,000 measurements per second |
| Response Time | < 1 ms |
| Sample Types | Powders, granules, tablets, capsules, fibers, films, sheets, yarns, cigarettes |
| Output | Simultaneous moisture content (%) and bulk density (g/cm³) |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible workflows |
| Interface | RS-485, Ethernet (TCP/IP), 4–20 mA analog output |
| Operating Temperature | 0–50 °C |
| Enclosure Rating | IP65 |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Volume Range | 50–60 mL |
| Material | PTFE (Polytetrafluoroethylene) |
| Outer Diameter | 28–29 mm |
| Total Height | 135 mm |
| Cap Options | Threaded, Reflux, Handle, Dual-Integrated, Flared, Flat |
| Temperature Resistance | Up to 250 °C (ambient-pressure operation) |
| Compliance | ASTM D5511, ISO 11466, USP <231>, GLP-compliant sample handling |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Classification | Domestic (China) |
| Model | M6 Microwave Digestion Vessel |
| Price Range | USD 0.15 – 165 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TG-I |
| Price Range | USD 140–700 (FOB Shanghai) |
| Instrument Category | TLC Auxiliary Equipment |
| Cutting Platform Dimensions | 300 × 250 mm |
| Origin | Hubei, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TH-980C |
| Instrument Type | Laboratory |
| Anion Separation | 7 anions in ≤16 min |
| Anion Detection Limit | ≤5 µg/L (as Cl⁻) |
| Anion RSD | ≤3% (as SO₄²⁻) |
| Linear Range | ≥10² |
| Cation Separation | Li⁺, Na⁺, NH₄⁺, K⁺ in ≤16 min |
| Na⁺ Detection Limit | <50 µg/L |
| Conductivity Detector Resolution | ≤1/20,000 |
| Conductivity Range | 1–1000 µS |
| Pump Flow Rate | 0.1–5 mL/min |
| Max Pressure | 0–15 MPa |
| Flow Stability | ±1% |
| Pressure Fluctuation | ±1% |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KL-01 |
| Heating Module Temperature Range | Ambient to 150 °C |
| Gas Flow Control Range | 0–300 mL/min (dynamically adjustable) |
| Flow Control Accuracy | ≤ 0.1 mL/min |
| Maximum Operating Pressure | ≥ 1.0 MPa |
| Concentration Range Supported | ppt to ppm |
| Temperature Control Accuracy | ≤ ±1 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 1R 120354-A110 |
| Category | Mass Spectrometry Component |
| Import Status | Genuine Imported OEM Part |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | AAA-Direct |
| Pricing | Upon Request |
| Pump Material | PEEK (chemically inert, pH 0–14 compatible) |
| Pump Type | Tandem dual-piston, constant stroke |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | <0.1% at 1.0 mL/min |
| Flow Precision | <0.1% RSD at 1.0 mL/min |
| Pressure Range | 50–5000 psi |
| Pressure Pulsation | ≤1% |
| Gradient Ratio Accuracy | ±0.5% at 2.0 mL/min |
| Gradient Ratio Precision | ±0.5% RSD at 2.0 mL/min |
| Eluent Options | Isocratic: 1 |
| Gradient | up to 4 |
| Gradient Delay Volume | <400 µL |
| EG Concentration Range | 0.01–100 mM |
| EG Compatible Eluents | KOH, LiOH, NaOH, CO₃²⁻/HCO₃⁻, CO₃²⁻, MSA |
| EG Concentration Increment | 0.01 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| Max EG Operating Pressure | 3000 psi (21 MPa) |
| Organic Solvent Tolerance | Anion mode: ≤25% methanol |
| Cation mode | solvent-free aqueous only |
| Operating Temperature | 4–40 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Dimensions (H×W×D) | 41×23×56 cm |
| Weight | 25 kg |
| Power | 90–265 V AC, 47–63 Hz |
| Ion Reservoir Dimensions | 23×7×10 cm, 1.6 kg |
| Cr-TC Trap Column | 3.8×3.8×5.8 cm, 60 g |
| Eluent Organizer (EO) | Holds four 1–2 L or two 4 L chemically resistant PE/epoxy-coated bottles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AI/AS 1310 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity | 8-position (AI 1310) or 155-position (AS 1310) |
| Needle Wash Options | Single or dual-solvent (A/B/C/D, A+B, C+D) pre- and post-injection |
| Injection Modes | Minimum Needle Depth & Standard Needle Depth |
| Compatibility | Thermo Scientific GC systems (e.g., TRACE 1300/1600 series) |
| Upgrade Path | AI 1310 → AS 1310 |
| Optional Dual-Inlet Kit | AS 1310 Gemini Kit (enables simultaneous dual-port injection) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Antaris II |
| Instrument Type | Laboratory |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–12000 cm⁻¹ |
| Scan Speed | 5 scans/sec |
| Data Sampling Interval | 2 cm⁻¹ |
| Measurement Modes | Transmission, Diffuse Reflectance, Transflectance, Transdiffuse |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ARL 3460 |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Line Density | 3600 lines/mm |
| Wavelength Range | 120–850 nm |
| Number of Channels | 60 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ARL 3460 |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets ASTM E1184, ISO 11577, and EN 10052 for metallic alloy analysis |
| Software | ARL SpectraGraph v8.x (with full calibration history and audit trail) |
| Detector Type | Photomultiplier Tube (PMT) array |
| Excitation Source | High-energy spark discharge (400–1000 V, adjustable frequency) |
| Typical Analysis Time | 20–45 s per sample |
| Wavelength Range | 120–800 nm |
| Resolution | ≤ 0.01 nm at 200 nm |
| Sample Form | Solid metal discs or pins (Ø 25–40 mm, thickness ≥ 5 mm) |
| Gas Requirement | Argon purge (99.995% purity, flow rate 3–5 L/min) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | easySpark 1160 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARL PERFORM'X Sequential WDXRF |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ARL Perform’X |
| Instrument Type | Floor-standing |
| Instrument Class | Scanning-type |
| X-ray Tube Power Options | 1500 W / 2500 W / 4200 W |
| Elemental Range | Be to U (Atomic Number 4 to 92) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ARL QUANT'X |
| Form Factor | Benchtop/Floor-standing |
| Application Scope | General-purpose |
| Elemental Range | F to U (no elemental restrictions) |
| Quantification Range | <1 ppm to 100% |
| Energy Resolution | ≤140 eV at Mn Kα |
| Short-term Precision | RSD < 0.3% over 8 hours |
| Detector | High-performance Peltier-cooled Silicon Drift Detector (SDD) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ/θ |
| Angular Accuracy | ±0.002° |
| Detector | Solid-state 2D pixel detector (55 × 55 µm pixel pitch) |
| Sample Handling | Manual 1-position holder or optional 6-position autosampler |
| X-ray Source | Cu or Co sealed-tube anode |
| Cooling | Optional water-cooling system |
| Data Output | Automated LIMS integration |
| Compliance | IEC 61000-4, IEC 62471, EN 61000-6-3, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher technology transfer & quality oversight) |
| Model | ARL™ QUANT EDXRF |
| Pricing | Available upon consultation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biomate 160 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioMate 160 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Automated |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Chromeleon™ 7.4 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Thermo Fisher Cindion Combustion Ion Chromatography System |
| Price | Upon Request |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Flow Rate Range | 100–500 mL/min |
| Maximum Operating Pressure | 30–45 psi |
| Operating Temperature Range | 500–1200 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DFS High-Resolution GC/MS |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| GC Configuration | Dual-Column, Dual-Trace 1310 GC Integration |
| Automation | TriPlus RSH Autosampler |
| Ion Source | Removable, Vacuum-Lock Ion Box |
| Analyzer Architecture | Double-Focusing Magnetic Sector with Ring-shaped Electrostatic Analyzer (ESA) |
| Calibration | Field-Based Mass Calibration Independent of Scan Speed, Ion Polarity, and Ionization Mode |
| Detection | Dual-Stage Electron Multiplier with Pneumatic Valve Vacuum Lock |
| Regulatory Compliance | Designed for EPA Method 1613/8270, EU Directive 2006/122/EC, WHO IPCS Dioxin Guidelines, USP <1225>, FDA 21 CFR Part 11 Audit Trail Support |
| Brand | Thermo Fisher |
|---|---|
| Model | DFS |
| Type | Double-Focusing Magnetic Sector GC-MS |
| Detector | Dual-Channel Electron Multiplier with Convertor Electrode |
| Resolution | Up to 100,000 (10% Valley) |
| Mass Range | 10–2000 m/z |
| Ion Source | Removable, Modular EI/CI Source |
| Vacuum System | Pneumatic Valve Lock for Ion Box Exchange Without Venting |
| GC Compatibility | Dual Trace 1310 GCs on Single Ion Source |
| Automation | TriPlus RSH Autosampler with Dual-Column Sequential Injection |
| Calibration | Field-Based, Mode-Independent Mass Calibration |
| Software | Thermo Xcalibur with DFS-Specific Acquisition & Quantitation Modules |
| Compliance | Designed for EPA Method 1613/8270, EU 2017/625, ISO 18073, and GLP/GMP environments requiring 21 CFR Part 11 audit trails |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate Range | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-AP |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 1152 positions (microtiter plate) / 81 vials (10 mL) |
| Injection Cycle Time | <30 s for 5 µL injection |
| Precision | RSD <0.3% |
| Fluidic Path | Full PEEK™ construction |
| Needle Design | Moving-needle architecture |
| Temperature Control | 4–60 °C sample tray cooling |
| Integrated Pre-injection Analysis | Conductivity & pH measurement |
| Automation Capabilities | Automated internal standard addition, on-line dilution, pre-column derivatization, matrix removal, analyte preconcentration, fraction collection, re-injection, and sample ejection |