| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II C |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Method 7473, SN/T 3511–2013, HJ 910–2017, HJ 917–2017, HJ 923–2017, Cosmetics Safety Technical Specifications (2015 Edition) |
| Sample Introduction | Direct Solid/Liquid Injection Without Prior Digestion |
| Optical Design | Dual-Beam, Dual-Cell Configuration with Real-Time Baseline Monitoring |
| Moisture Management | Integrated Desiccant Drying Tube |
| Operational Readiness | Ambient-Temperature Operation, No Preheating Required |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Model | ONH836-G8 |
| Analysis Range | O: 0.01 ppm–5 wt% |
| N | 0.01 ppm–3 wt% |
| H | 0.01 ppm–0.3 wt% |
| Analytical Precision | O/N: ±0.25 ppm |
| H | ±0.5 ppm |
| Detection Limit | 0.001 ppm |
| Analysis Time | 90 s |
| Pulse Furnace Power | 10 kW |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy7 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit (Zn at 213.856 nm) | <0.1 µg/L |
| Precision (RSD) | ≤1.0% |
| Stability (RSD over 4 hours) | ≤1.0% |
| Wavelength Range | 165–1100 nm |
| Optical Resolution | ≤0.007 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Detection Limit (Ca at 396.847 nm) | 0.155 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (2-hr drift) | ≤1.0% |
| Optical Resolution | 0.005 nm |
| RF Generator Cooling | Air-Cooled |
| Plasma Torch Assembly | Ceramic RF Load Coil |
| Optical System | Echelle Grating with ICCD Detector |
| Compliance | ASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E |
| Brand | Teledyne Photon Machines |
|---|---|
| Origin | Imported |
| Model | LSX-213 G2+ |
| Laser Wavelength | 213 nm (5th harmonic of Nd:YAG) |
| Pulse Energy | >4 mJ |
| Pulse Width | <5 ns |
| Ablation Spot Size Range | 4–200 µm (14 standard apertures) |
| Microscope Magnification | 2.6×–32.5× |
| Optical Resolution | <2 µm |
| XY Stage Step Resolution | 0.16 µm |
| Laser Type | Q-switched, solid-state Nd:YAG |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | HRS-300, HRS-500 |
| Focal Length | 300 mm (HRS-300), 500 mm (HRS-500) |
| f-number | f/3.9 (HRS-300), f/6.5 (HRS-500) |
| Linear Dispersion | 2.38 nm/mm (HRS-300), 1.52 nm/mm (HRS-500) |
| PMT Resolution (1200 g/mm grating, 435.8 nm, 10 µm slit) | 0.09 nm (HRS-300), 0.05 nm (HRS-500) |
| CCD Resolution (1200 g/mm grating, 435.8 nm, 20 µm pixel & slit) | 0.10 nm (HRS-300), 0.07 nm (HRS-500) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tekmar 3100 |
| Instrument Type | Water & Soil Dual-Mode Purge and Trap System |
| Sample Tray Capacity | 84 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | 180–300 °C |
| Purge Heater Temperature Range | Ambient to 90 °C |
| Sample Vial Chilling Temperature | 4–10 °C |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Integrated Online LIBS System |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Online |
| Integration Level | Fully Integrated |
| Core Components | Q-switched Nd:YAG Laser Source, Echelle or Czerny–Turner Spectrometer, ICCD Detector, Synchronization Controller, LIBS-Specific Acquisition & Analysis Software |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OLED/QLED Device Lifetime Testing System |
| Price Range | USD 14,000 – 28,000 |
| Channel Capacity | 32 / 64 / 128 (scalable to 512 channels) |
| Operating Modes | Constant Current, Constant Voltage, Constant Luminance (user-selectable) |
| Current Output Range | 0.03 µA – 100 mA (accuracy ±1% of reading) |
| Voltage Output Range | 1.0 – 20 V (accuracy <±1%) |
| Device Architecture Support | Bottom-emission, top-emission, inverted, and standard stack configurations (customizable per device architecture) |
| Substrate Compatibility | Standard 5 cm × 5 cm |
| Temperature Range | RT+10°C to 100°C (standard) |
| Environmental Options | Inert atmosphere testing (N₂/Ar), glovebox-integrated operation, UPS-backed power supply |
| Software Platform | LabVIEW-based control and data acquisition with real-time logging, timestamped event tracking, and export-ready CSV/Excel output |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RTS-B |
| Price | USD 70,000 (approx.) |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 60–5000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Excitation Lasers | Standard 532 nm |
| Microscope | Olympus BX53 or Leica DM2700 upright research-grade microscope |
| Gratings | 150, 600, 1800 grooves/mm (blaze wavelength selectable) |
| Detector | Deep-cooled, infrared-enhanced, low-noise scientific CCD |
| Confocal Mode | Slit-CCD coupled high-throughput confocal architecture |
| Optical Path | Horizontal, rigid monolithic design |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-EX |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1100 nm |
| Spectral Resolution | <0.8 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-HiR |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1100 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-mini |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TES-300 |
| Optical Design | Single-Beam |
| Detector | CCD Array |
| Wavelength Range | 104–1040 nm |
| Wavelength Selection | Manual Drive |
| Spectral Bandwidth | 10 nm |
| Wavelength Accuracy | ±0.01 nm |
| Stray Light | < 0.01% T |
| Grating | 1200 l/mm, Al/MgF₂ coated (optimized 100–300 nm), user-replaceable |
| Input Focal Length | 200 mm |
| Output Focal Length | 187.9 mm |
| F/# | 4.2 |
| Deviation Angle | 64° |
| Optimal Operational Range | 115–300 nm |
| Full Usable Range | 25–1000 nm (gold coating recommended below 100 nm) |
| Slit | Adjustable entrance and exit slits on dual-arm configuration |
| Grating Drive | Encoded Angular Encoder Grating Drive (AEGD) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | TESC-5133 |
| Temperature Control Range | −42 °C to 90 °C |
| Compliance | ASTM D5133, ASTM D7110, SH/T 0732, GB/T 11121 |
| Cooling Method | Solid-State Peltier |
| Sample Chamber | Sealed, Thermally Isolated Enclosure |
| Automation Level | Fully Automated, Unattended Operation |
| Footprint | Compact Benchtop Design |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | FIB-SEM-TOF-SIMS |
| Price Range | USD 1.3M–2.6M (FOB Europe) |
| Mass Analyzer Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | 1–2500 Da |
| Mass Resolution (M/ΔM) | >800 (at 10% valley definition) |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nanospace SIMS |
| Instrument Type | Orthogonal Time-of-Flight (OTOF) SIMS |
| Mass Range | 1–1,500 Da |
| Mass Resolution | >9,500 (FWHM at m/z 100) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2051 |
| Instrument Type | Portable |
| Parameter Types | pH & Temperature |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with NIST-traceable buffers |
| Electrolyte | Replaceable gel electrolyte |
| Probe Tip Diameter | 11 mm |
| Probe Shaft Length | 25 mm |
| Display | Dual-line backlit LCD |
| Housing Material | ABS |
| Protection Rating | IP65 |
| Weight | 135 g |
| Dimensions (L×W×H) | 145 × 38 × 167 mm |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–+70 °C |
| Battery | LR44 button cell (≈80 h operation) |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2061 |
| Instrument Type | Pen-style pH Meter |
| Parameters Measured | pH and Temperature |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to 80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Standard | NIST-traceable buffer solutions |
| IP Rating (with TopSafe protective sleeve) | IP68 |
| Weight | 69 g |
| Dimensions (L×W×H) | 197 × 33 × 20 mm (including probe and TopSafe) |
| Display | 2-line LCD with backlight |
| Power Supply | 1 × CR2032 battery (≈80 h operating time) |
| Housing Material | ABS |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–+70 °C |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2061 |
| Instrument Type | Pen-style |
| Parameter Types | Dual-parameter (pH + temperature) |
| pH Measurement Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0 to +60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Solution Standard | NIST-traceable |
| Protection Rating (with TopSafe sleeve) | IP68 |
| Weight | 69 g |
| Dimensions (L×W×H) | 197 × 33 × 20 mm (with probe and TopSafe) |
| Display | Backlit 2-line LCD |
| Battery | CR2032 (≈80 h operation) |
| Operating Temperature | 0 to +60 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2062 |
| Instrument Type | Pen-style pH Meter |
| Parameter Types | pH + Temperature (NTC) |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range | 0–+60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with NIST-traceable buffer solutions |
| Electrode Type | Integrated gel-filled pH electrode with annular transparent reference junction |
| Probe Diameter | 11 mm |
| Probe Sleeve Length | 35 mm |
| IP Rating | IP68 |
| Display | 2-line LCD |
| Power | 1 × CR2032 battery (≈80 h operation) |
| Weight | 115 g (with TopSafe protective sleeve), 65 g (without) |
| Dimensions | 197 × 33 × 20 mm (L×W×H, with probe & sleeve) |
| Housing Material | ABS |
| Operating Temperature | 0–+60 °C |
| Storage Temperature | −20–+70 °C |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2062 |
| Instrument Type | Pen-Style |
| Parameter Types | pH & Temperature |
| Measurement Accuracy | ±0.02 pH |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to 80 °C, max 5 min) |
| Temp. Accuracy | ±0.4 °C |
| Temp. Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with automatic buffer recognition |
| Calibration Standard | NIST-traceable buffers |
| Protection Rating | IP68 |
| Electrode Type | Integrated gel-filled ring-electrode with built-in temperature sensor |
| Probe Shaft Diameter | 11 mm |
| Sleeve Length | 35 mm |
| Weight | 115 g (with TopSafe protective sleeve), 65 g (without) |
| Dimensions | 197 × 33 × 20 mm (L×W×H, with probe & sleeve) |
| Display | 2-line LCD |
| Battery | CR2032 (≈80 h operation) |
| Housing Material | ABS |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–+70 °C |
| CE Marked | 2014/30/EU |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1100 |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 0–40 °C |
| Measurement Time | < 1 s |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Display | 3.5-inch backlit graphical LCD |
| Data Storage | EEPROM, up to 250 measurements |
| Memory Slots | 25 product-specific calibration profiles |
| Power Supply | NiMH rechargeable battery |
| Battery Life | ~5 h (median usage, fully charged) |
| Protection Rating | IP20 |
| Interface | USB |
| Software | TEWS Moisture View Lite © |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1150 |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Measurement Time | <1 s |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Sample Temperature Range | 5–60 °C (with optional Pt100 or IR temperature sensor and auto thermal stabilization compensation) |
| Ambient Temperature Range | 0–40 °C |
| Enclosure Rating | IP20 |
| Display | Backlit LCD graphic display (320 × 240 pixels), 5.7-inch diagonal |
| Internal Memory | EEPROM storage for up to 25 product profiles and 250 measurement records |
| Data Interface | USB (PC connectivity) |
| Analog Output | 0(4)–20 mA with current isolation |
| Software Support | TEWS Moisture View Lite © |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 3012 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Temperature | 0–40 °C |
| Analog Input | Product Temperature |
| Analog Output | Measured Values |
| Digital I/O | Control & Status Signals |
| Communication Interfaces | RS-232/RS-485 Serial, Ethernet (10/100BASE-T), CAN 2.0A/B, LAN |
| Max Sampling Rate | 40,000 readings/s |
| Application Scope | In-line moisture & density measurement of fast-moving discrete or continuous materials (e.g., cigarettes, yarns, tablets, capsules, filter rods) |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4260 / MW 4270 / MW 4200 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 160 VA (MW 4260), 200 VA (MW 4270) |
| Operating Temperature | 0–45 °C |
| Display | 10.4" LED color touchscreen (MW 4270), 5" LCD (MW 4260), single-line LED (MW 4200) |
| Data Interfaces | 1× Ethernet, 1× analog input (0/4–20 mA), 3× analog outputs (0/4–20 mA), 8× passive digital outputs, 8× digital inputs |
| Measurement Rate | up to 3,500 readings per second |
| Internal Data Storage | 60,000 measurements |
| Enclosure Rating | IP55 (industrial duty), ATEX-certified variants available for gas/dust hazardous areas |
| Sensor-to-Display Distance | up to 8 m (MW 4200 optimized for remote mounting) |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4300 / MW 4310 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 60 VA |
| Operating Temperature | 0–45 °C |
| Data Interfaces | 2× RS-232 (COM + Service), 1× Ethernet, 3× USB, 1× Analog Input (0/4–20 mA for optional IR sensor), 1× Pt100 temperature sensor input, PS/2 mouse & keyboard + VGA display support |
| Measurement Time | Millisecond-scale |
| Internal Data Storage | 6,000 measurements |
| External Server Storage | Unlimited |
| Display | MW 4300 — integrated 10.4" (26.4 cm) LCD color touchscreen |
| Sample Volume Range | 1–2000 mL |
| Max. Sensor Units Supported | 2 (lab-grade microwave sensors) |
| Calibration Profiles | Up to 200 product-specific calibration curves |
| Software | Pre-installed TEWS Moisture View© |