| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Orion AquaMate 7100 |
| Optical Design | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5.0 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Wavelength Scanning | Automatic |
| Display | 7-inch High-Resolution Touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Orion AquaMate 8100 |
| Optical Design | Double-Beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 2.0 nm |
| Stray Light | <1.0%T @ 198 nm (KCl), <0.05%T @ 220 nm (NaI), <0.03%T @ 340 nm (NaNO₂) |
| Automation Level | Automatic Wavelength Selection |
| Display | 7-inch High-Resolution Touchscreen |
| Brand | Orion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Lab Star Series Benchtop Water Quality Analyzer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 320P-06 |
| Pricing | Available Upon Request |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A112, A122 |
| Pricing | Upon Request |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A111 (Benchtop), A121 (Portable) |
| Instrument Type | Benchtop & Portable |
| Parameter Type | Single-Parameter (pH/mV/Temp) |
| pH Accuracy | ±0.01 |
| pH Range | –2.00 to 16.00 |
| pH Resolution | 0.1 / 0.01 |
| mV Range | ±1600.0 mV (mV), ±1999.9 mV (RmV) |
| mV Resolution | 0.1 |
| mV Accuracy | ±0.1 mV |
| Temperature Range | –5 to 105 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.1 °C |
| Calibration Points | Up to 3-point pH |
| Buffer Recognition | USA, NIST, DIN |
| Data Storage | 50 entries (manual/auto) |
| Input Interfaces | BNC (pH electrode), 8-pin mini-DIN (ATC probe) |
| Power | 4 × AA alkaline batteries or universal 100–240 V AC adapter |
| IP Rating | IP54 (A111), IP67 (A121) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A211 (Benchtop), A221 (Portable) |
| Instrument Type | Benchtop pH Meter |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| mV/RmV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Points | Up to 5 (pH) |
| Calibration Edit | Yes (A211 only) |
| Data Storage | 2000 entries (A211), 1000 entries (A221), GLP-compliant |
| Record Modes | Manual, Auto, Timed Interval (A211) |
| Input | BNC pH electrode, 8-pin mini-DIN ATC probe |
| Output | RS232, USB |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries |
| IP Rating | IP54 (A211), IP67 (A221) |
| [Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A212 (Benchtop), A222 (Portable) |
| Measurement Parameters | Conductivity, TDS, Salinity, Resistivity, Temperature |
| Portability | Benchtop (IP54) / Portable (IP67) |
| Conductivity Range | 0.001 μS/cm to 3000 mS/cm |
| TDS Range | 0–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt (practical) |
| Temperature Range | −5 to 105 °C |
| Accuracy | ±0.5% of reading (conductivity/resistivity/TDS/salinity), ±0.1 °C (temperature) |
| Minimum Resolution | 0.001 μS/cm or 4 significant digits |
| Calibration Points | Up to 5-point conductivity |
| Data Storage | 2000 GLP-compliant entries (A212), 1000 GLP-compliant entries (A222) |
| Connectivity | RS232, USB, optional PC software |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries] |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A214 (Benchtop), A324 (Portable) |
| Instrument Type | Benchtop / Portable Multiparameter Electrochemical Analyzer |
| Parameter Types | pH, mV/RmV, ISE (Ion Concentration), Temperature |
| pH Range | –2.000 to 20.000 |
| ISE Range | 0–19999 (unitless or in ppm, mg/L, M, %, ppb) |
| pH Resolution | 0.001 |
| ISE Resolution | Up to 4 significant digits |
| pH Accuracy | ±0.001 |
| mV Accuracy | ±0.1 mV |
| Temperature Range | –5 to 105 °C (RDO mode: 0–50 °C) |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 2000 (A214), 5000 (A324) GLP-compliant records |
| Calibration Points | Up to 6 (pH/ISE), up to 5 (portable) |
| Compliance | GLP, ASTM D1293, ISO 10523, USP <791>, FDA 21 CFR Part 11 (via optional software audit trail) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A222 |
| Detection Parameters | Multi-parameter (Conductivity, TDS, Resistivity, Salinity, Temperature) |
| Portability | Portable |
| Conductivity Range | 0.001 µS/cm to 3000 mS/cm |
| TDS Range | 0–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt practical salinity |
| Temperature Range | −5 to 105 °C |
| Accuracy | ±0.5% of reading (conductivity, resistivity, TDS, salinity) |
| Minimum Resolution | 0.001 µS/cm or 4 significant digits |
| Calibration Points | Up to 5-point conductivity calibration |
| Electrode Constant Range | 0.001–199.9 cm⁻¹ |
| Temperature Compensation | Linear (0–10.0%/°C) and non-linear (seawater curve) |
| Data Storage | 2000 measurements with GLP-compliant metadata (date/time, sample ID, user ID, calibration info) |
| Connectivity | USB and RS232 |
| Power | 4 × AA batteries or optional AC adapter |
| IP Rating | IP67 (portable unit) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310C-01 |
| Pricing | Upon Request |
| Conductivity Range | 0.000 to 3000 mS/cm |
| Resolution | Up to 4 significant digits, down to 0.001 µS/cm |
| Conductivity Accuracy | ±0.5% of reading or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001 to 100 MΩ·cm |
| Salinity Range | 0.01 to 80.0 ppt NaCl |
| TDS Range | 0 to 19,999 mg/L |
| Cell Constant Range | 0.001 to 199.9 cm⁻¹ |
| Reference Temperatures | 15°C, 20°C, or 25°C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 points |
| Temperature Range | −5°C to 105°C |
| Temperature Resolution | 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD |
| Sensor Interface | Conductivity – miniDIN |
| Communication | Bidirectional RS232, optional USB cable |
| Data Storage | 200 GLP-compliant measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Self-Test | Yes |
| Password Protection | Yes |
| Firmware/Method Update | Network-enabled |
| Power | 4 × AA batteries + universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Ingress Protection | IP54 (benchtop), IP67 (portable variant) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310C-06 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 320C-01 |
| Price | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Resolution | Up to 4 significant digits, down to 0.001 µS/cm |
| Accuracy | ±0.5% of reading or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19,999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 15°C, 20°C, or 25°C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 points |
| Temperature Range | −5°C to 105°C |
| Temperature Resolution | 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C) |
| Temp. Accuracy | ±0.1°C |
| Temp. Compensation | Automatic or manual |
| Display | Backlit LCD |
| Sensor Interface | Conductivity – miniDIN |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 200 entries |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Self-Test | Yes |
| Password Protection | Yes |
| Firmware/Method Update | Via PC software |
| Power | 4 × AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Ingress Protection | Benchtop – IP54 |
| [Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 320C-06 |
| Price | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Resolution | Up to 4 significant digits, down to 0.001 µS/cm |
| Conductivity Accuracy | ±0.5% of reading or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19,999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 15°C, 20°C, or 25°C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 points |
| Temperature Range | −5°C to 105°C |
| Temperature Resolution | 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD |
| Connectivity | Mini-DIN conductivity sensor port |
| Data Logging | 200 entries |
| Calibration History | Last 10 calibrations stored |
| Method Storage | 10 user-defined methods |
| Self-Test | Yes |
| Password Protection | Yes |
| Firmware Update | Network-enabled via PC software |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Ingress Protection | IP67 (portable unit), IP54 (benchtop variant)] |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | A321 |
| Instrument Type | Portable |
| Parameter Types | Dual (pH/mV) |
| Measurement Range | -2.000 to 20.000 |
| Resolution | 0.1 / 0.01 / 0.001 |
| Accuracy | ±0.001 |
| Calibration Buffer Recognition | Auto-detect (USA/NIST/DIN) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410C-01 |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Orion Star LogR Series |
| Model | LogR |
| Measurement Principle | Potentiometric pH with integrated LogR temperature sensing via pH electrode membrane resistance |
| pH Range | –2.000 to 19.999 |
| Resolution | 0.001 pH (selectable) |
| Accuracy | ±0.002 pH |
| Calibration Points | 1–5-point, auto-buffer recognition (USA/NIST, EURO/DIN) |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.2 mV or ±0.05% of reading, whichever is greater |
| Temperature Range | 0–100 °C (manual or LogR-compensated) |
| LogR Temp Accuracy | ±0.1 °C (10–100 °C) |
| Resistance Range | 0–6000 MΩ |
| Resistance Resolution | 0.1 MΩ (<2000 MΩ), 1 MΩ (≥2000 MΩ) |
| Data Storage | 1000 readings with timestamp |
| Interface | RS232 |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Scientific Orion |
|---|---|
| Origin | USA |
| Model | T910 |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| pH Range | 2.000 to 20.000 |
| mV Range | −2000.0 to +2000.0 mV |
| Meter Accuracy | ±0.2% of reading |
| Meter Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| Titration Accuracy | ±0.5% RSD |
| Titration Resolution | 0.001 / 0.01 / 0.1 mL (user-selectable) |
| Burette Capacity Options | 10 mL, 20 mL (standard), 50 mL (ISO 8655-3 compliant) |
| Microstep Precision | 25,600 microsteps per motor revolution (≥2 million total steps over full stroke) |
| Stirrer Speed | 5 selectable speeds (250–3700 RPM) |
| Data Storage | 100 titration records with timestamp, calibration logs, and direct measurement history |
| Display | 5.7″ color capacitive touchscreen (640 × 480), glove-compatible |
| Operating Languages | English, Chinese, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Certifications | CE, TÜV 3-in-1, FCC, EN/IEC 61326-1, IEC 61010, IP51 |
| Dimensions & Weight | 25.4 × 40.6 × 35.6 cm (10 × 16 × 14 in), 5.67 kg (12.5 lb) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PDD Detector |
| Instrument Type | Universal Selective Detector for GC |
| Operating Temperature Range | Up to 400 °C |
| Linear Dynamic Range | 10⁵ |
| Method Detection Limit (MDL) | Low-picogram level |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Portable Optical Analyzer |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Prima PRO |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Prima PRO |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Q Exactive Focus LC-MS/MS |
| Price Range | USD 260,000 – 390,000 (based on configuration and regional duties) |
| Instrument Type | Hybrid Quadrupole-Orbitrap Mass Spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Q Exactive™ GC Orbitrap |
| Instrument Category | Orbitrap-based GC-MS/MS System |
| Chromatography Type | Conventional Gas Chromatography Coupled Mass Spectrometry |
| Mass Range | Not Specified |
| Resolution | Up to 100,000 (FWHM) at m/z 272 |
| Mass Accuracy | < 1 ppm (typical, internal calibration) |
| Sensitivity | < 6 fg OFN (octafluoronaphthalene) LOD under EI mode |
| Scan Speed | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Q Exactive HF LC-MS System |
| Instrument Type | Orbitrap-based Hybrid Quadrupole-Orbitrap Mass Spectrometer |
| Scan Speed | Up to 12 Hz MS/MS in 1 s |
| Resolution (at m/z 200) | 240,000 FWHM (standard mode), up to 500,000 FWHM (enhanced mode) |
| Mass Accuracy | < 1 ppm RMS (internal calibration), < 3 ppm RMS (external calibration) |
| Mass Range | m/z 50–6,000 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Q Exactive HF-X |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) hybrid with Orbitrap mass analyzer |
| Application Scope | General-purpose high-resolution LC-MS/MS for proteomics, metabolomics, and small-molecule analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q Exactive HF-X Hybrid Quadrupole-Orbitrap |
| Instrument Type | Orbitrap-Based LC-MS/MS |
| Application Scope | Universal (Proteomics, Metabolomics, Biopharma, Small Molecule Analysis) |
| Max Resolving Power | 240,000 (FWHM) at m/z 200 |
| Scan Speed | Up to 40 Hz (MS/MS) |
| Ionization Compatibility | Electrospray (ESI), Atmospheric Pressure Chemical Ionization (APCI), optional Nano-ESI |
| Acquisition Modes | Data-Dependent Acquisition (DDA), Data-Independent Acquisition (DIA), Parallel Reaction Monitoring (PRM), Intact Protein Mode, High Mass Range (HMR) Mode |
| Software Platform | Thermo Scientific™ Compound Discoverer™, Proteome Discoverer™, and xCalibur™ v4.5+ with FDA 21 CFR Part 11 compliance support |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Q Exactive Plus LCMS |
| Instrument Type | Hybrid Quadrupole-Orbitrap Mass Spectrometer |
| Pricing Range | USD 650,000 – 980,000 (FOB USA) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Q Exactive UHMR |
| Instrument Type | Quadrupole-Orbitrap Hybrid Mass Spectrometer |
| Mass Range | Up to 80,000 m/z |
| Precursor Selection Range | Up to 25,000 m/z |
| Ion Transmission | Enhanced In-Source Capture |
| Fragmentation | HCD in Injection Flatapole Cell |
| Application Focus | Native MS, Top-Down Proteomics, Intact Protein & Mega-Dalton Complex Analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured) |
| Model | Thermo Scientific Q Exactive UHMR Hybrid Quadrupole-Orbitrap Mass Spectrometer |
| Pricing | Upon Request |
| Mass Range | 350–80,000 m/z |
| Mass Accuracy (External Calibration) | <3 ppm RMS (CsI cluster ions) |
| Max Resolution | 200,000 @ m/z 400 |
| Scan Rate | up to 12 Hz @ m/z 400 with R = 12,500 |
| Dynamic Range | >5,000:1 |
| Precursor Selection Range | up to 25,000 m/z |
| Ion Transmission Mode | In-source trapping for enhanced desolvation and transmission efficiency |
| Detection Mode | Synchronous Charge Detection enabled for Direct Mass Technology™ |