Chemical Analysis Instruments
Filter
Showing 9361–9390 of 10621 results
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Parameter Types | pH, Temperature, Time, Status |
| pH Measurement Range | 0.0 to 14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Precision | 0.001 pH (display resolution) |
| Calibration Standards | NIST-traceable (China version) / USA NBS-type (International version) |
| Display | 5.0-inch color TFT touchscreen |
| Data Storage | Cyclic memory with >10-year non-volatile retention |
| Compensation | Automatic temperature compensation (ATC) |
| Compliance | Designed for GLP-compliant lab environments |
| Power Supply | AC adapter (100–240 VAC, 50/60 Hz) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP101 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Power Industry-Specific |
| Temperature Control Range | 8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy) |
| Oven Ramp Rate | 0.1–39 °C/min (standard) |
| Oven Cool-Down Rate | 0.1–39 °C/min (standard) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | TimePower |
|---|---|
| Model | TP1051 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Producer) |
| Type | Laboratory & Field-Deployable Dew Point Analyzer |
| Measurement Principle | Chilled-Mirror–Calibrated Electrochemical Sensor (Vaisala CARBOCAP®-derived architecture) |
| Operating Temperature | −20 °C to +60 °C |
| Accuracy | ±2 °C dew point |
| Repeatability | ±0.5 °C dew point |
| Measurement Range | −100 °C to 0 °C dew point (frost point mode below 0 °C) |
| Response Time (T90) | < 60 s (dependent on gas flow and moisture level) |
| Resolution | 0.1 °C dew point |
| Gas Flow Rate | 0.5–1.5 L/min |
| Sample Temperature Range | −20 °C to +50 °C |
| Ambient Temperature (continuous operation) | 0 °C to 40 °C |
| Ambient Temperature (intermittent use) | −20 °C to +50 °C |
| Relative Humidity Range | 0–100 %RH |
| Maximum System Pressure | 0.6 MPa |
| Output Signal | 4–20 mA (max. load 800 Ω) |
| Power Supply | AC 220 V, 50 Hz |
| Probe Protection | Stainless steel sintered filter (ISO 4406 Class 17/14 compliant) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP106 |
| Price | Upon Request |
| Measurement Principle | Molybdenum Blue Photometric Method (Silicomolybdate Reduction with 1-Amino-2-Naphthol-4-Sulfonic Acid) |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% FS |
| Repeatability | ≤±1% FS |
| Drift | <±1% FS/24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Light Source | Monochromatic Cold LED |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Channels | 1–6 Configurable |
| Environmental Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (user-selectable) |
| Alarm Outputs | Independent per channel — flow interruption, upper/lower limit |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 mm × 720 mm × 280 mm |
| Panel Cutout | 670 mm × 410 mm |
| Weight | 22 kg |
| Compliance | Designed for continuous industrial water quality monitoring in regulated environments |
| Brand | TimePower |
|---|---|
| Model | TP106 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instruments Co., Ltd. |
| Measurement Principle | Molybdenum Blue Photometric Method |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulate Limit | <5 µm, non-colloidal |
| Light Source | Monochromatic cold LED |
| Display | 7.0-inch color TFT touchscreen (Chinese UI) |
| Channels | 1–6 configurable |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable) |
| Alarm Outputs | Independent per channel — high/low limit, flow interruption |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460×720×280 mm |
| Panel Cutout | 670×410 mm |
| Weight | 22 kg |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP106 |
| Price | Upon Request |
| Measurement Principle | Molybdenum Blue Photometric Method |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% FS |
| Repeatability | ≤±1% FS |
| Drift | <±1% FS/24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Light Source | Monochromatic Cold LED |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Channels | 1–6 selectable |
| Data Storage | 30 days local history |
| Environmental Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460×720×280 mm |
| Panel Cutout | 670×410 mm |
| Weight | 22 kg |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (configurable) |
| Alarm Outputs | Independent per channel — high/low limit, flow interruption |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Valves | Imported High-Precision Electromagnetic Valves |
| Compliance | Designed for continuous industrial water quality monitoring in regulated environments |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP107 |
| Measurement Principle | Vanadomolybdophosphoric Yellow Photometric Method (Acidic Medium) |
| Display | 7.0-inch TFT Color Touchscreen (Chinese UI) |
| Range Options | 0.00–20.00 mg/L or 0.00–50.00 mg/L |
| Accuracy | ±2% FS |
| Repeatability | ≤±1% FS |
| Drift | ≤±1% FS/24 h |
| Response Time | < 4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Particulates | < 5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (configurable) |
| Alarm Outputs | Independent per channel (flow loss, high/low limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions | 460 × 280 × 720 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Channel Configurability | 1–6 channels selectable |
| Data Storage | 30 days of historical measurement records |
| Light Source | Monochromatic cold LED |
| Calibration | Automated dual-point standard calibration on user-defined schedule |
| Compliance | GB/T 6913–2008 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP107 |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | TP107 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP108 |
| Price | Upon Request |
| Measurement Principle | Colorimetric Analysis (p-Dimethylaminobenzaldehyde Reaction in Acidic Medium) |
| Measurement Range | 0.0–100.0 µg/L |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <4 min |
| Cycle Time | ~3 min per channel |
| Channels | 1–6 configurable |
| Light Source | Monochromatic Cold LED |
| Valve Actuation | Imported High-Precision Solenoid Valves |
| Calibration | Automated Dual-Point Standard Calibration (User-Defined Interval) |
| Data Storage | 30 days of historical data (timestamped, per channel) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable per channel) |
| Alarm Outputs | Independent per-channel alarms (flow loss, upper/lower limit) |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP108 |
| Price | Upon Request |
| Measurement Range | 0.0–100.0 μg/L |
| Display | 7.0-inch color LCD touchscreen, Chinese interface |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated analog current outputs (0–20 mA / 4–20 mA / 0–10 mA, user-selectable) |
| Alarm Outputs | Independent per-channel alarms (flow interruption, upper/lower limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Channel Configuration | 1–6 channels selectable |
| Light Source | Monochromatic cold LED source |
| Calibration | Automated dual-point standard calibration at user-defined intervals |
| Data Storage | 30 days of historical data (per channel) |
| Compliance | Designed for continuous operation in industrial process environments per IEC 61000-6-2/6-4 EMI immunity & emission standards |
| Brand | TimePower |
|---|---|
| Model | TP110 |
| Type | Online (Process) pH Meter |
| Form Factor | Panel-Mount / Wall-Mountable Transmitter |
| Measurement Parameters | pH and Temperature |
| pH Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Repeatability | ≤1% |
| Input Impedance | >1×10¹² Ω |
| Temperature Sensor | Pt1000 |
| Temp. Measurement Range | 0.0–99.9 °C |
| Automatic Temperature Compensation (ATC) Range | 0.1–60.0 °C |
| Sample Temp. Operating Range | 5–60 °C |
| Ambient Temp. Operating Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Storage Temp. | −25–+55 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable, galvanically isolated) |
| Relay Outputs | 2 SPST (AC 220 V / 3 A or DC 30 V / 3 A), user-configurable |
| Enclosure Rating | IP65 |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic memory with >10-year retention after power loss |
| Mounting Options | Panel cutout (138×138 mm), wall-mount, or rack-mount |
| Electrode Interface | Compatible with flow-through, immersion, flanged, and pipe-threaded pH electrodes |
| Standard Electrodes | TP110-001 (ultrapure water), TP110-002 (general-purpose), TP110-003 (wastewater), TP110-004 (high-temp), TP110-005 (flat-surface), TP110-006 (wastewater reference) |
| Calibration | Two-point calibration using standard buffer solutions (e.g., pH 4.00, 6.86, 9.18) |
| Dimensions (H×W×D) | 155×142×125 mm |
| Weight | 1.6 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP110 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | TP120 |
| Measurement Parameter | Single-parameter (Conductivity/TDS/Resistivity/Salinity/Temp) |
| Portability | Portable |
| Application | Industrial online monitoring |
| Conductivity Range | 0–300 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 5–45 °C |
| Accuracy | ±1% FS |
| Minimum Resolution | 0.001 µS/cm |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Temperature Sensor | Pt1000 |
| Temp Compensation Range | 0–60 °C |
| Sample Temp Range | 5–60 °C |
| Max Sample Pressure | <0.6 MPa |
| Environmental Humidity | ≤90% RH (non-condensing) |
| IP Rating | IP65 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 145 × 120 × 150 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.64 kg |
| Output Options | Isolated 0–10 mA / 0–20 mA / 4–20 mA (load <300 Ω) |
| Relay Outputs | 2 SPST, configurable, AC 220 V / 3 A or DC 30 V / 3 A |
| Data Storage | Cyclic non-volatile memory, >10 years retention after power loss |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP120 |
| Detection Parameters | Multi-parameter |
| Portability | Portable |
| Conductivity Range | 0–1000 µS/cm (with selectable cell constants: K=0.01, 0.1, 1.0, 10.0 cm⁻¹) |
| TDS Range | 0–500 ppm (calculated) |
| Resistivity Range | 0.001–1000 MΩ·cm |
| Salinity Range | 0–35 ppt (NaCl equivalent) |
| Temperature Range | 5–60 °C |
| Accuracy | ±2.5% FS |
| Minimum Resolution | 0.001 µS/cm |
| Repeatability | ≤1% FS |
| Temperature Sensor | Pt1000 |
| Temp. Compensation Range | 0–60 °C |
| IP Rating | IP65 |
| Output Signals | 4–20 mA (isolated, load <300 Ω), 0–10 mA, 0–20 mA |
| Relay Outputs | 2 SPST, AC 220 V / 3 A or DC 30 V / 3 A |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 145 × 120 × 150 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.64 kg |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic memory with >10-year data retention upon power loss |
| Operating Humidity | ≤90% RH (non-condensing) |
| Storage Temperature | −25 to +55 °C |
| Sample Pressure Limit | <0.6 MPa |
| Brand | TimePower |
|---|---|
| Model | TP120 / TP121 / TP122 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Portability | Portable |
| Application Environment | Industrial Online Process Monitoring |
| Conductivity Measurement Ranges | K=0.01 cm⁻¹: 0.000–3.000 µS/cm and 0.00–30.00 µS/cm |
| K=0.1 cm⁻¹ | 0.00–30.00 µS/cm and 0.0–300.0 µS/cm |
| K=1.0 cm⁻¹ | 0.0–300.0 µS/cm and 0–3000 µS/cm |
| K=10.0 cm⁻¹ | 0–3000 µS/cm and 0–30,000 µS/cm |
| Temperature Range | 0–60 °C |
| Accuracy | ±2.5% of Full Scale (F.S.) |
| Minimum Resolution | 0.001 µS/cm |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP122 |
| Price | Upon Request |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Measurement Range | 0–1000 mS/cm |
| Accuracy | ±2.5% F.S. |
| Resolution | 0.1 mS/cm |
| Repeatability | 1% F.S. |
| Temperature Sensor | Pt1000 |
| Temp. Compensation Range | 0–60 °C |
| Sample Temp. Range | 5–50 °C |
| Ambient Temp. Range | 5–45 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Error | ±0.5 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 145 × 120 × 150 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.64 kg |
| Isolated Current Output | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Load Capacity | ≤750 Ω |
| Output Accuracy | 1% F.S. |
| Relay Output | AC 250 V / 5 A or DC 30 V / 5 A |
| Mounting | Panel-mount / Wall-mount / Rack-mount |
| Electrode Options | Flow-through / Immersion / Flanged (custom configurations available) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP130 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Model | TP130 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Channel Options | 1–4 independent channels |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Measurement Range | pNa 0.0–8.00 (equivalent to 2300 µg/L–0.023 µg/L Na⁺) |
| Accuracy | ±0.03 pNa or ±2 µg/L (whichever is greater) |
| Repeatability | ±1% F.S. |
| Drift | <±0.02 pNa/24 h or <±0.5 µg/L/24 h |
| Temperature Compensation Range | 0.1–60 °C |
| Calibration | Two-point calibration (e.g., 20 µg/L and 200 µg/L Na⁺ standards) |
| Response Time | <2 minutes (t₉₀) |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 0.1–60 °C |
| Sample Particulate Limit | <5 µm, non-colloidal |
| Ambient Operating Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~1.5 L/month (diisopropylamine, DIPA) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (user-selectable per channel) |
| Alarm Outputs | Configurable relay outputs for high/low sodium, high sample temperature |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ~40 W |
| Dimensions (H×W×D) | 690×450×300 mm |
| Panel Cutout | 645×410 mm |
| Weight | ~15 kg |
| Brand | Timepower |
|---|---|
| Model | TP130 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Category | Online Electrochemical Analyzer for Sodium Ion (Na⁺) |
| Measurement Principle | Potentiometric Detection via Sodium-Selective Electrode (Nernstian Response) |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Measurement Range | pNa 0.00–9.36 (equivalent to 0.01 µg/L – 23.0 g/L Na⁺) |
| Accuracy | ±0.03 pNa or ±3 µg/L (whichever is greater) |
| Repeatability | ≤±1% F.S. |
| Drift | <±0.02 pNa/24 h or <±0.5 µg/L/24 h |
| Temperature Compensation Range | 0–60 °C |
| Calibration Method | Two-point calibration (using standard Na⁺ solutions) |
| Response Time | <2 min |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 0–60 °C |
| Sample Particulate Limit | <5 µm, no colloidal content |
| Ambient Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Reagent Consumption | ~1.5 L/month (diisopropylamine, DIPA) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (≤750 Ω) |
| Alarm Outputs | Independent relay outputs per channel (flow failure, high/low limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Data Storage | Cyclic non-volatile memory |
| Channel Configurability | 1–4 independent measurement channels |
| A/D Resolution | 24-bit |
| Microcontroller Architecture | Low-power, high-integrity single-chip system |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Equipment Co., Ltd. |
| Model | TP140 |
| Measurement Principle | Conductivity-based concentration determination |
| Measurable Media | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% FS |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Temperature Sensor | Pt1000 |
| Temp. Measurement Range | 0.0–99.9 °C |
| Temp. Compensation Range | 0.1–60.0 °C |
| Sample Temp. Range | 5–60 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Enclosure Rating | IP65 |
| Dimensions (L×W×H) | 142 mm × 125 mm × 155 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 1.6 kg |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Relay Outputs | 2 SPST, AC220 V / 3 A or DC30 V / 3 A |
| Data Storage | Cyclic non-volatile memory, >10 years retention after power loss |
| Mounting Options | Panel-mount (standard), wall-mount, rack-mount |
| Electrode Mounting | Flow-through, immersion, flanged, or inline pipe mount |
| Display | 128×64 dot-matrix LCD, full Chinese interface |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Model | TP140 |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Alarm Relays | 2 SPST (AC 220 V / DC 30 V, 3 A) |
| Display | 128 × 64 dot-matrix LCD with Chinese interface |
| Measurement Range | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% FS |
| Resolution | 0.01% |
| Repeatability | <1% FS |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Sample Temp. Range | 5–50 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C (electrode excluded |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 145 × 120 × 150 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.64 kg |
| Mounting | Panel-mount / wall-mount / rack-mount |
| Electrode Options | Flow-through / immersion / flanged (custom configurations available upon consultation) |
| Data Logging | Cyclic memory with auto-overflow overwrite |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP140 |
| Pricing | Upon Request |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Measurement Ranges | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Temperature Sensor | Pt1000 |
| Temp. Measurement Range | 0.0–99.9 °C |
| Automatic Temp. Compensation Range | 0.1–60.0 °C |
| Sample Temp. Range | 5–60 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Storage/Transport Temp. | −25–55 °C (electrode excluded |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Dimensions (L×W×H) | 142×125×155 mm |
| Panel Cutout | 138×138 mm |
| Weight | 1.6 kg |
| Brand | TimePower |
|---|---|
| Model | TP140 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Measuring Range | NaOH (0–10.00%), Na₂CO₃ (0–10.00%), HCl (0–10.00%), H₂SO₄ (0–20.00%), HNO₃ (0–15.00%), NaCl (0–20.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sensor Type | Pt1000 RTD |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Relay Outputs | 2 × SPST (AC220 V / 3 A or DC30 V / 3 A) |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Power Supply | AC 220 V ±10%, 50 Hz, <5 W |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 155×142×125 mm |
| Panel Cutout | 138×138 mm |
| Weight | 1.6 kg |
| Data Retention | >10 years (non-volatile memory) |
| Installation | Panel-mount / Wall-mount / Rack-mount |
| Electrode Mounting | Flow-through / Immersion / Flanged / In-line |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP140 |
| Price | Upon Request |
| Measurement Principle | Potentiometric pH sensing with temperature-compensated conductivity correlation for acid/base concentration estimation |
| Compliance Context | Designed for industrial process monitoring per ISO 5725 (accuracy/trueness), ASTM D1125 (electrical conductivity of water), and GLP-aligned data integrity requirements |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP150 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP151 |
| Price | Upon Request |
| Measurement Principle | Clark-type polarographic membrane electrode |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable), load < 300 Ω |
| Relay Output | AC 220 V / 3 A or DC 30 V / 3 A |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Display | 128 × 64 LCD, Chinese interface |
| Measurement Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ≤1% |
| Accuracy | ±1.5% FS |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25 to +55 °C (electrode ≥0 °C) |
| Enclosure Rating | IP65 |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Conversion | 24-bit |
| Microcontroller Architecture | Integrated low-power MCU |
| Housing Dimensions | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TP152 |
| Output Signals | (0–10) mA, (0–20) mA, (4–20) mA (selectable) |
| Load Impedance | < 300 Ω |
| Relay Output | AC 220 V / 3 A or DC 30 V / 3 A |
| Power Supply | AC (85–265) V, 45–65 Hz |
| Power Consumption | ≤ 15 W |
| Display | 128 × 64 LCD, Chinese interface |
| Measurement Range | (0.00–20.00) mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ≤ 1% |
| Accuracy | ±1.5% FS |
| Response Time (T90) | < 5 min at 25 °C |
| Temperature Compensation Range | (0.0–60.0) °C |
| Sample Temperature Range | (5–60) °C |
| Ambient Temperature Range | (5–45) °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Storage & Transport Temp. | (−25–55) °C (electrode ≥ 0 °C) |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Data Retention | > 10 years after power loss |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP160 |
| Instrument Type | Industrial Online ORP Meter |
| Display | 128×64 Dot-Matrix LCD (Chinese Interface) |
| ORP Measurement Range | ±2000 mV |
| Electrical Indication Error | ±1 mV |
| Resolution | 1 mV |
| Temperature Compensation Range | 0–60 °C |
| Sample Temperature Range | 5–60 °C |
| Sample Pressure Rating | <0.6 MPa |
| Ambient Temperature Range | 5–45 °C |
| Ambient Humidity | ≤85% RH (non-condensing) |
| Storage & Transport Temperature | −25–55 °C |
| Isolated Current Output | 0–10 mA / 0–20 mA / 4–20 mA (user-selectable, load ≤750 Ω) |
| Relay Outputs | 2 SPST NO contacts (configurable, AC220 V/3 A or DC30 V/3 A) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Enclosure Rating | IP65 |
| Power Consumption | ≤15 W |
| Data Retention on Power Loss | >10 years |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP160 |
| Instrument Type | Industrial Online ORP Meter |
| Display | 128×64 Dot-Matrix LCD (Chinese Interface) |
| Measurement Range | ±2000 mV |
| Electrical Accuracy | ±1 mV |
| Resolution | 0.1 mV |
| Temperature Compensation Range | 0–60 °C |
| Sample Temperature Range | 5–60 °C |
| Sample Pressure Limit | < 0.6 MPa |
| Environmental Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Output Signals | Isolated Current Output (0–10 mA / 0–20 mA / 4–20 mA), Load < 300 Ω |
| Relay Outputs | 2 SPST (AC 220 V / 3 A or DC 30 V / 3 A), Configurable Alarm Thresholds |
| Enclosure Rating | IP65 |
| Data Logging | Cyclic Storage with Auto-Overflow Management |
| Memory Retention After Power Loss | >10 Years |
| Dimensions (H×W×D) | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Electrode Type | Pt-based Redox Electrode (Direct Potentiometric Measurement) |