Chemical Analysis Instruments
Filter
Showing 10051–10080 of 10462 results
| Brand | Yoke |
|---|---|
| Model | P911 |
| Type | Benchtop pH Meter |
| Parameter Type | Single-parameter (pH/mV/Temperature) |
| pH Range | -2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | -1999.9 to 1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | 0 to 100 °C |
| Temperature Resolution | 0.1 °C |
| Input Impedance | ≥1 × 10¹² Ω |
| Input Current | ≤2 × 10⁻¹² A |
| Calibration | 1–3 point, auto-buffer recognition (US/EU, NIST, and Chinese standard buffer series) |
| Data Storage | 2000 sets |
| Connectivity | USB 2.0 port, optional Bluetooth module for wireless printing and data transmission |
| GLP Compliance | Yes |
| IP Rating | IP54 |
| Power Supply | 9 V DC, 2 A (110–220 V AC, 50–60 Hz adapter) |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Conductivity Meter |
| Model | P912 |
| Measurement Parameters | Single-parameter (Conductivity/TDS/Resistivity/Salinity/Temp) |
| Form Factor | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0–2000 mS/cm (6 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±0.5% FS (instrument), ±0.8% FS (with electrode) |
| Resolution | 0.01 / 0.1 / 1 µS/cm |
| Temperature Resolution | 0.1 °C |
| Temp Accuracy | ±0.5 °C |
| Data Storage | 2000 sets |
| Connectivity | USB-A port, micro-USB service port, optional Bluetooth 4.2 module |
| Enclosure Rating | IP54 |
| Power Supply | 12 V DC, 1 A (universal 110–220 V AC, 50/60 Hz adapter) |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Brand | Yoke |
|---|---|
| Model | PHB-8 |
| Type | Pen-Style pH Meter |
| Measurement Range | 0–14 pH |
| Accuracy | ±0.1 pH |
| Electrode | E-300 Combination pH Electrode |
| Power Supply | Three CR2032 Lithium Coin Cells (3 V × 3) |
| Battery Life | >1500 hours (typical continuous operation) |
| Origin | Shanghai, China |
| Manufacturer | Yoke Instrument Co., Ltd. |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV) |
| Measurement Range | 0.0–14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Temperature Compensation | Manual (0–60 °C) |
| Display | 3½-digit LED |
| Input Impedance | ≥1×10¹² Ω |
| Stability | ±0.1 pH / 3 h |
| Calibration | One-point or two-point using standard buffer solutions (Chinese national buffer series) |
| Included Accessories | E-201-C combination pH electrode, two sets of pH calibration buffer powders |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV) |
| pH Range | 0.00–14.00 pH |
| Extended pH Range | –2.00–18.00 pH |
| mV Range | –1999–+1999 mV |
| Temperature Range | 0.0–99.9 °C |
| Resolution | 0.01 pH / 1 mV / 0.1 °C |
| Accuracy | ±0.01 pH ±1 digit / ±1 mV ±1 digit / ±0.3 °C ±1 digit |
| Input Impedance | ≥1 × 10¹² Ω |
| Stability | ±0.01 pH ±1 digit / 3 h |
| Temperature Compensation | Manual (0–60 °C) or Automatic (0–100 °C) |
| Calibration Options | One-point or Two-point |
| Compatible Buffers | NIST-traceable and Chinese Standard pH buffer series |
| Display | Dual-line LCD with blue backlight |
| Electrode Compatibility | E-201-C pH composite electrode |
| Dimensions | 300 × 220 × 90 mm |
| Weight | 1.5 kg |
| Included Accessories | 1 × E-201-C electrode, 2 sets of pH standard buffer powders, 1 × T-818-B-6 temperature probe |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RG-3604AA |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Solid-State Detector |
| Background Correction | Deuterium Lamp Correction |
| Repeatability (RSD) | ≤0.7% |
| Detection Limit | ≤0.008 µg/mL |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidths | 0.1, 0.2, 0.7, 1.4, 2.0 nm (5-step auto-switching) |
| Wavelength Accuracy | ±0.3 nm |
| Lamp Positions | 4 |
| Atomization System | Flame only (graphite furnace optional, external) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3604AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0–2.0 A |
| Optical System | Single-beam |
| Lamp Positions | 4 |
| Background Correction | Combined D₂ Lamp + Self-Reversal Full-Spectrum Background Correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3608AA |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Repeatability | ≤ 0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0 – 2.0 A |
| Background Correction | Deuterium Lamp + Self-Reversal Full-Spectrum Correction |
| Lamp Holder | 8-position, 360° Rotating, Compatible with High-Performance Hollow Cathode Lamps |
| Optical System | Single-Beam, All-Reflective Optics |
| Atomizer Type | Flame-Based Atomization System |
| Software Platform | RG-WinAAS Workstation (Windows OS) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp Correction + Self-Reversal Double Background Correction |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.7, 1.4, 2.0 nm (5-step automatic selection) |
| Wavelength Accuracy | ±0.2 nm |
| Lamp Positions | 8-position rotating turret (360° rotation) |
| Atomization Modes | Flame only (graphite furnace compatible via external module) |
| Detection Limit (Flame) | ≤0.006 µg/mL (for Cu) |
| Repeatability (RSD) | ≤0.6% |
| Background Correction Method | Deuterium Arc Lamp + High-Performance Self-Reversal Dual-Mode Correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | RG-3608AA |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Resolution | 0.2 nm |
| Repeatability (RSD) | ≤0.6% |
| Detection Limit (Cu) | ≤0.006 µg/mL |
| Software Platform | RG-WinAAS (Windows-based) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3618AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Dual-Beam |
| Lamp Positions | 8-position rotating turret (compatible with high-performance hollow cathode lamps) |
| Background Correction | Combined deuterium lamp and self-reversal (SR) full-spectrum background correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | RG-3618AA |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.7 / 1.4 / 2.0 nm (5-step automatic selection) |
| Wavelength Accuracy | ±0.15 nm |
| Lamp Positions | 8-slot rotating turret (360° motorized rotation) |
| Optical System | Single-beam with all-reflective optics |
| Monochromator | Plane grating |
| Detector | Solid-state photodiode array |
| Background Correction | Dual-mode — D₂-lamp and self-absorption (SA) methods |
| Detection Limit (Flame) | ≤0.004 µg/mL for Cu |
| Precision (RSD) | ≤0.5% (n=10, typical aqueous standards) |
| Atomization Modes | Air-acetylene flame |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3624AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Single-beam |
| Lamp Positions | 4 |
| Background Correction | D₂ Lamp + Self-Reversal Full-Spectrum Correction |
| Atomizer Type | Electrothermal Graphite Furnace |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RG-3628AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Spectral Bandwidth | 0.1, 0.2, 0.7, 1.4, 2.0 nm (5-step automatic selection) |
| Lamp Positions | 8-slot rotating turret (360° motorized rotation) |
| Atomization Modes | Flame and External Graphite Furnace |
| Background Correction | Dual-mode — D₂ continuum lamp (full-spectrum) and high-performance self-reversal (SR) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating (1200 grooves/mm) |
| Optical System | Single-Beam Czerny-Turner (350 mm focal length) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Spectral Bandwidth | 0.1/0.2/0.4/0.7/1.4/2.0 nm (6-step motorized selection) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Resolution | 0.2 nm |
| Baseline Drift (Flame, Cu) | ±0.003 A/30 min (static), ±0.005 A/15 min (dynamic) |
| Detection Limits | Cd ≤1.0 pg, Cu ≤25 pg (GF-AAS) |
| Characteristic Mass | Cd ≤0.6 pg, Cu ≤20 pg |
| Precision (RSD) | ≤0.6% (Flame, Cu), ≤3% (GF-AAS, Cd) |
| Lamp Positions | 8-slot automatic turret |
| Light Sources | Hollow Cathode Lamps (HCLs) and Electrodeless Discharge Lamps (EDLs) |
| Safety Systems | Flame gas/oxidant pressure monitoring, graphite furnace cooling water flow & argon pressure interlocks, temperature and power fault detection |
| Power Requirement | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 830 × 650 × 560 mm |
| Weight | 90 kg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3638AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Single-beam |
| Lamp Positions | 8-position rotating turret (360° rotation, compatible with high-performance hollow cathode lamps) |
| Background Correction | Dual-mode — D₂ lamp + self-reversal (SR) full-spectrum background correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3668AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0–2.0 A |
| Optical System | Dual-beam |
| Lamp Positions | 8-position rotating turret (compatible with high-performance hollow cathode lamps) |
| Background Correction | Combined deuterium lamp and self-reversal (SR) background correction across full wavelength range |
| Software Platform | RG-WinAAS workstation for Windows OS |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-N6000 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch color TFT touchscreen |
| Data Storage | Internal 8 GB flash memory (supports ≥5000 absorbance readings or ≥500 calibration curves) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 hours (dual-lamp auto-switching with usage logging) |
| Grating | 1200 lines/mm plane holographic grating |
| Interface | RS-232, USB Host (Type-B), USB Device (Type-A), optional thermal printer port |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 8 GB internal memory (supports ≥5000 absorbance readings or 500 calibration curves) |
| Microprocessor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 hours (automated D₂ and W lamp switching with usage logging) |
| Grating | 1200 lines/mm holographic plane grating |
| Sample Compartment | Extra-large, compatible with optional 8-position rotating carousel and 5-cell wide-format cuvette holder |
| Interface Ports | RS-232 printer port, USB Host (Type-B), USB Device (Type-A), SD/USB flash drive export |
| Software | PC-based spectral analysis suite with GLP-compliant audit trail, CFR Part 11 ready configuration options |
| Firmware | Field-upgradable via network download |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-N6000Plus |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch color TFT LCD |
| Data Storage | 8 GB internal flash memory (supports up to 5000 absorbance readings or 500 calibration curves) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 hours (automatically switched D₂ and W lamp with usage tracking) |
| Grating | 1200 lines/mm holographic plane grating |
| Sample Compartment | Large-volume chamber compatible with optional 8-position rotating carousel or 5-position ultra-wide sample holder |
| Connectivity | RS-232 printer port, USB Host (Type-B), USB Device (Type-A), firmware upgrade via network |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-U6S |
| Optical System | Dual-beam with CT monochromator |
| Detector | Hamamatsu photomultiplier tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm (fixed) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Display | 7-inch TFT-LCD (1024×768) with Omron tactile keypad |
| Internal Storage | 32 GB flash memory |
| Data Capacity | Up to 5,000 absorbance measurements or 500 calibration curves |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Interface | RS-232C (printer), USB Device (PC connection), USB Host (U-disk support) |
| File Export Formats | CSV, QUA, TXT, BMP |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T-U8 |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (2 nm optional) |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Light Source | Pulsed Xenon Lamp |
| Automation Level | Automatic Wavelength Scanning |
| Display | 7-inch TFT True-Color LCD |
| Data Storage | Internal 32 GB + USB Host (U-disk support) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Data Capacity | Up to 5,000 absorbance readings or 500 calibration curves |
| Interface | RS-232C (printer), USB Device (PC connection), USB Host (U-disk) |
| Output Formats | *.csv, *.qua, *.txt, *.bmp |
| Language Support | English & Chinese |
| Optional Accessory | 8-position Rotating Cuvette Holder |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T-U9 |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Automation Level | Automatic Wavelength Scanning |
| Light Source | Pulsed Xenon Lamp |
| Display | 10.1-inch Color Touchscreen |
| Internal Storage | 32 GB |
| Data Storage Capacity | Up to 5,000 absorbance readings or 500 calibration curves |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Interface Ports | RS-232C (for printer), USB Device (for PC connection), USB Host (for U-disk), Support for CSV, QUA, TXT, BMP export formats |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | T2600 |
| Price Range | USD 2,800–4,200 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.05% at 220 nm |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T2602 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% T (at 220 nm, using NaI solution) |
| Display | 7-inch TFT color LCD (1024 × 600 resolution) |
| Data Storage | 16 GB internal memory |
| Interfaces | RS-232C, USB Device, USB Host |
| Supported Output Formats | CSV, QUA, TXT, BMP |
| Maximum Data Capacity | 2000 absorbance measurements or 500 calibration curves |
| Light Sources | Imported deuterium lamp and tungsten-halogen lamp |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | T2602 |
| Optical System | Dual-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (full range), ±0.1 nm at 656.1 nm |
| Spectral Bandwidth | 2 nm (fixed) |
| Stray Light | ≤0.05% at 220 nm |
| Transmittance Accuracy | ±0.3% T |
| Wavelength Repeatability | ±0.1 nm |
| Display | 7-inch TFT LCD (1024 × 600) |
| Data Storage | Internal 16 GB + USB Host support |
| Interfaces | RS-232C, USB Drive, USB HOST |
| Light Sources | Imported deuterium lamp & tungsten-halogen lamp |
| Optical Design | Czerny-Turner monochromator with suspended optical bench |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T2602S |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (selectable) |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 7-inch TFT true-color LCD |
| Data Storage | Internal 16 GB + USB flash drive support |
| Connectivity | RS-232C, USB Device, USB Host |
| Processor | ARM11 |
| Data Capacity | Up to 2000 absorbance measurements or 500 calibration curves |
| Optional Accessories | 8-position rotating cuvette holder, integrated auto-sampler flow path |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Domestic (PRC-made) |
| Model | T3200 |
| Price Range | USD 4,200 – 7,000 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scan |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.05% at 220 nm |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | T3202 |
| Optical System | Dual-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (full range), ±0.1 nm at 656.1 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05% at 220 nm |
| Transmittance Accuracy | ±0.3% T |
| Wavelength Repeatability | ±0.1 nm |
| Display | 10.1-inch color capacitive touchscreen (1024 × 600) |
| Internal Storage | 8 GB |
| Data Interfaces | RS-232C, USB Device (for PC connection), USB Host (for flash drive) |
| Onboard Data Capacity | 5,000 absorbance readings or 500 calibration curves |
| Supported Output Formats | *.csv, *.qua, *.txt, *.bmp |
| Self-Diagnostic Function | Yes |
| Optical Design | Suspended optical bench with reinforced aluminum baseplate |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T3202S |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (standard), adjustable to 0.5/1/2/4/5 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal 8 GB + USB drive support |
| Interface | RS-232C, USB Device, USB Host |
| Onboard Memory | Up to 5000 absorbance measurements or 500 calibration curves |
| Optional Accessories | 8-position rotating cuvette changer, integrated flow cell system |