Chemical Analysis Instruments
Filter
Showing 10141–10170 of 10347 results
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTB-3420A |
| Adsorption Tubes Capacity | 20 |
| Temperature Control Range | Ambient to 400 °C (typical operational range for tube conditioning) |
| Timer Range | 0–99 h 99 min |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 170 mm × 390 mm × 400 mm |
| Net Weight | ~8 kg |
| Tube Compatibility | 6 mm OD (¼″ OD), unlimited length |
| Purge Gas | Nitrogen (requires external supply, filtered via integrated deep-gas purifier) |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTB-3420B |
| Adsorption Tubes Capacity | 24 |
| Heating Stages | 5-zone programmable ramping |
| Cooling Method | Forced-air rapid cooling |
| Gas Control | Electronic mass flow controllers (MFCs) |
| User Interface | 7-inch capacitive touch screen |
| Exhaust Management | Electronically actuated exhaust valve with centralized outlet |
| Tubing Material | Stainless steel |
| Pre-filtering | Integrated particulate and hydrocarbon filter at gas inlet |
| Tube Connection | Quick-release fittings with low-wear sealing design |
| Independent Channel Operation | Per-tube gas flow isolation and activation control |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PT-7900D |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Sample Tray Capacity | 30-position |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT-7900D-II |
| Instrument Type | Water & Soil Integrated Purge and Trap System |
| Sample Tray Capacity | 72 positions |
| Fluid Handling | Integrated Syringe Pump for Automated Liquid Addition |
| Temperature Control Zones | 7 (Sample Zone, Valve Oven, Purge Tube, Transfer Line, Cold Trap, Water Trap, Desorption Zone) |
| Desorption Ramp Rate | Up to 2000 °C/min |
| Gas Path Materials | Passivated Stainless Steel & PEEK |
| Valves | Imported Electromechanical Switching Valves |
| Pressure Monitoring | Digital Electronic Pressure Sensors |
| Flow Control | Mass Flow Controllers (MFCs) |
| User Interface | 7-inch Touchscreen with Real-time Status Visualization |
| Compliance Standards | ASTM D6866, EPA Methods 502.2, 524.2, 624, 8260D, 8270E |
| Safety Features | System Self-Check at Power-On, Over-Temperature Protection, Leak Detection, Electrical Leakage Protection |
| Cleaning Functions | Methanol Rinse, High-Temperature Water Rinse, Automated Back-Flush of Entire Gas Path |
| Sample Agitation | Motorized Stirring Module |
| Optional Purge Tube Configurations | U-shaped, 5 mL or 25 mL |
| GC/GC-MS Synchronization | Universal Trigger Interface for Major Chromatographic Platforms (Agilent, Thermo Fisher, Shimadzu, Waters, PerkinElmer) |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | PT-8030 |
| Sample Tray Capacity | 30 positions |
| Instrument Type | Water & Soil Dual-Mode Purge and Trap System |
| [Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-8100 |
| Sample Tray Capacity | 100 positions |
| Sample Type Compatibility | Aqueous and Solid (Soil/Sediment) |
| Dual-Needle Architecture | Independent aqueous & solid sample pathways |
| Cryogenic Sample Cooling Option | Available |
| Automated Trap Bake-Out & Desorption | Yes |
| Automated Line Cleaning & Blank Analysis | Yes |
| Calibration Curve Automation | Up to 10 concentration levels |
| Methanol Extraction Module | Integrated for soil samples |
| Soil Heating Range | Up to 90 °C with variable-speed magnetic stirring |
| GC Trigger Interface | Configurable TTL/relay signal output |
| Software Control | PC-based method editor, queue management, real-time status monitoring, audit-trail-enabled logging] |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Model | PT-8200 |
| Sample Tray Capacity | 120 positions |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Compliance | ASTM D6866, ISO 15681-2, USP <621>, EPA Methods 502.2, 524.2, 624, 8260D, 8270E (via GC/GC-MS coupling) |
| Software Control | PC-based GUI with method scheduling, audit trail, and instrument status monitoring |
| Cooling Function | Peltier-cooled sample tray (4–10 °C) |
| Foam Detection & Suppression | Real-time optical foam sensor with automated antifoam reagent injection |
| Dual-Needle Architecture | Independent solid-phase and liquid-phase sampling needles (Patent ZL202220256614.6) |
| Internal Standard Delivery | 3-position (expandable to 5) pressurized vial station with N₂-driven precision dispensing (10 programmable volume settings) |
| Solid-Phase Needle Heating | Adjustable temperature control (up to 120 °C) to prevent condensation |
| Positional Calibration | 3-axis robotic coordinate mapping with multi-point auto-calibration |
| GC Trigger Interface | Configurable TTL/relay signal output for seamless synchronization with GC or GC-MS systems |
| Data Integrity | Full electronic logbook (sample history, warnings, errors), automatic fault-induced shutdown, 21 CFR Part 11–compliant user access controls and audit trail (optional firmware module) |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PT-8600 |
| Instrument Type | Aqueous Sample Dedicated |
| Dimensions | 8U (19-inch Rack Mountable) |
| Sample Handling | Fully Automated Online Flow-through Sampling |
| Trap Configuration | Straight-Path Ambient-Temperature Trap |
| Thermal Management | Independent Trap Bake-out, Pre-heat & Desorption Control |
| Fluidic Architecture | Fully Enclosed Inert Gas/Liquid Path (Stainless Steel + PEEK) |
| Calibration & QC | Automated Internal Standard Addition (3× amber vials, 10-step volumetric precision), Auto Blank Analysis, Auto Dilution, Auto Calibration Curve Generation |
| System Intelligence | Programmable Cycle Timing, Real-time Foam Detection & Suppression, Zone-specific Temperature/Flow Optimization (Purge, Dry-Purge, Bake, Desorb), Modular Integrated Fluidics with Minimized Dead Volume |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Positions | 16 |
| Standard Quantitative Loop Volume | 100 µL (customizable) |
| Leak Detection | Pre-valve-opening automated leak check |
| Flow Path Treatment | Passivated (inertized) tubing and valves |
| Cleaning Protocol | Software-controlled reverse-flush for all flow paths |
| Valve Architecture | Multi-position rotary valve |
| Control Interface | PC-based method programming with unattended operation (scheduled, repetitive, continuous injection) |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | STP-6 |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Positions | 6 |
| Repeat Injection Capability | Unlimited cycles per tube |
| Flow Control | Mass Flow Controller (MFC) |
| Vaporization Chamber | Heated, Temperature-Controlled |
| Valve Architecture | Integrated Solenoid Valve Manifold |
| User Interface | Standalone Touchscreen Control Panel |
| Power Supply | 220 V / 110 V (±10%), 50 Hz / 60 Hz (±2%) |
| Brand | Zhonhuipu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 40 positions |
| Simultaneous Heating Positions | 12 |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | 40–200 °C (optional up to 300 °C) |
| Valve & Transfer Line Temperature Range | 40–200 °C (optional up to 330 °C) |
| Quantitative Loop Volume | 1 mL (customizable up to 3 mL) |
| Temperature Control Accuracy | ±1 °C |
| Equilibration Time | 0–99.9 min |
| Pressurization Time | 0–9.99 min |
| Sampling Time | 0–9.99 min |
| Loop Equilibration Time | 0–9.99 min |
| Injection Time | 0–9.99 min |
| Analysis Time | 0–99.9 min |
| RSD | <1.2% (for 100 ppm ethanol in water) |
| Power Consumption | Peak 450 W |
| Dimensions (L×W×H) | 500 × 575 × 505 mm |
| Net Weight | ~36 kg |
| Brand | ZHP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ZND-1 |
| Automation Level | Fully Automated |
| Valve Inlet Temperature Range | 50–240 °C (customizable up to 330 °C), Control Accuracy: ±1 °C |
| Transfer Line Temperature Range | 40–230 °C, Control Accuracy: ±1 °C |
| Trap Temperature Range | −35 to 400 °C |
| Flash Heating Rate | >50 °C/s |
| Enrichment Time | 0–60 min |
| Injection Time | 0–10 min |
| Interval Time | 0–60 min |
| Sampling Time | 0–60 min |
| Sampling Flow Rate | 16–160 mL/min |
| RSD | ≤2.5% |
| Power Consumption | 450 W |
| Dimensions | 550 × 484 × 222 mm (5U rack-mount chassis) |
| Cooling Method | Semiconductor-based cryogenic trapping |
| Adsorbent Configuration | Dual-trap (A/B), each packed with three selective, deactived sorbents |
| Flow Control | Dual-channel Mass Flow Controller (MFC) |
| Valve Type | High-temp motor-driven 6-port valve (max. 240 °C standard |
| Interface | Universal TTL/RS-232 trigger output for synchronized GC and data system activation |
| Brand | ZHP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ZTD-1 |
| Automation Level | Fully Automated |
| Valve Injection Zone Temperature Range | 50–240 °C, Control Accuracy: ±1 °C (customizable to 330 °C) |
| Transfer Line Temperature Range | 40–230 °C, Control Accuracy: ±1 °C |
| Trap Temperature Range | −35 to 400 °C |
| Flash Desorption Ramp Rate | >50 °C/s |
| Enrichment Time | 0–60 min |
| Injection Time | 0–10 min |
| Interval Time | 0–60 min |
| Sampling Time | 0–60 min |
| Sampling Flow Rate | 16–160 mL/min |
| RSD | ≤2.5% |
| Power Consumption | 200 W |
| Dimensions | 550 × 484 × 175 mm (4U Rack-Mount Chassis) |
| Brand | Zhuhui HP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JX-5N |
| Automation Level | Semi-Automatic |
| Desorption Temperature Range | -35 °C to 450 °C |
| Valve Injection Zone Temperature Range | 50 °C to 240 °C, ±1 °C accuracy |
| Transfer Line Temperature Range | 50 °C to 240 °C, ±1 °C accuracy |
| Flash Heating Rate | >70 °C/s |
| Cryofocusing Trap Temperature | Down to -40 °C (ambient-dependent) |
| Enrichment Time | 0–60 min |
| Desorption Time | 0–10 min |
| Simulated Sampling Flow Rate | 16–160 mL/min |
| Power Consumption | 500 W |
| Cold Trap Cooling Method | Thermoelectric (Peltier) |
| Valve Type | Motor-Driven, Sulfinert-Passivated High-Temperature 6-Port Switching Valve |
| Tubing Material | Electropolished 316 Stainless Steel with Sulfinert Surface Treatment |
| Seals | PTFE |
| Dead Volume Optimization | Engineered Variable-Diameter Sulfinert-Treated Fittings |
| Brand | Zhuhui |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | 40–400 °C |
| Secondary Desorption (Cryofocusing) Temperature Range | −35 to 450 °C |
| Valve & Transfer Line Temperature Range | 40–240 °C, ±1 °C accuracy |
| Cryotrap Temperature Range | −35 to −5 °C |
| Sample Tray Capacity | Dual 20-position (40 total) |
| Cryofocusing Rate | >70 °C/s |
| Peak Width (Secondary Desorption) | <3 s |
| RSD | ≤2.5% (benzene in 0.05 μg methanol) |
| Sample Tube Dimensions | 1/4″ OD × 3.5″ L |
| Simulated Sampling Flow | 0–200 mL/min |
| Power | 500 W peak |
| Dimensions | 600 × 370 × 400 mm |
| Net Weight | ~25 kg |
| Brand | Zhuhui |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber / Cold-Trap Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | 40–400 °C |
| Secondary Desorption Temperature Range | −35–450 °C |
| Valve Heating Range | 40–240 °C, Accuracy: ±1 °C |
| Transfer Line Temperature Range | 40–240 °C, Accuracy: ±1 °C |
| Cold Trap Temperature Range | −35 to −5 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Positions | 40 |
| Cold Trap Cooling Method | Semiconductor-based |
| Secondary Desorption Ramp Rate | >70 °C/s |
| Peak Width (at 450 °C) | <3 s |
| Sample Tube Dimensions | 1/4″ OD × 3.5″ L |
| Enrichment Time | 0–60 min |
| Injection Time | 0–10 min |
| Simulated Sampling Time | 0–60 min |
| Simulated Flow Rate | 0–200 mL/min |
| RSD | ≤2.5% (benzene in 0.05 μg methanol) |
| Max Power Consumption | 500 W |
| Gas Path Materials | Passivated 316 stainless steel (RESTEK Siltek®/Sulfinert®-treated), PTFE seals, heated valve oven & transfer lines integrated |
| Compliance | GB 50325-2020, GB/T 18883-2022, HJ 583-2010, HJ 644-2013, HJ 734-2014 |
| Brand | ZHUOLIHANG |
|---|---|
| Origin | Shanghai, China |
| Model | XS11639-350-1050-25 |
| Detector | Hamamatsu S11639 InGaAs-enhanced CCD linear array |
| Spectral Range | 350–1050 nm |
| Pixels | 2048 |
| Slit Width | 25 µm |
| Optical Resolution | ~1.5 nm (FWHM @ 200 µm fiber) |
| Wavelength Accuracy | < ±0.5 nm |
| SNR | 300:1 (full signal, 100 ms integration) |
| Dark Noise | 50 RMS counts (100 ms) |
| Dynamic Range | 1300:1 (@ 100 ms) |
| A/D Resolution | 16-bit |
| Integration Time | 1 ms – 65 s |
| Interface | USB-Micro |
| Dimensions | 75 × 63.5 × 31.5 mm |
| Weight | 185 g |
| Brand | ZHYSHEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Sample Capacity | 20 positions per channel (dual-channel, total 40 samples per batch) |
| Compliance | HJ 644–2013, HJ/T 400–2007, GB/T 18883–2002, HJ 583–2010, GB 50325–2020, HJ 734–2014 |
| Thermal Zones | Four independently controlled zones (primary desorption, valve oven, transfer line, secondary desorption) |
| Sample Tube Activation | Built-in programmable tube conditioning |
| GC Interface | Universal hardware interface for Agilent, Thermo Fisher, Shimadzu, PerkinElmer, and domestic GC systems |
| Optional Accessories | Ambient-temperature or cryo-cooled secondary desorption module, fused quartz transfer line, replaceable injection needle |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | YSZ Single-Crystal Substrate |
| Pricing | Upon Request |
| Chemical Formula | (Zr,Y)O₂ (Zr:Y = 91:9) |
| Crystal Structure | Cubic |
| Lattice Constant | a = 5.125 Å |
| Density | 5.8 g/cm³ |
| Purity | 99.99% |
| Melting Point | 2800 °C |
| Thermal Expansion Coefficient | 10.3 × 10⁻⁶ /°C |
| Dielectric Constant | 27 |
| Growth Method | Arc Melting |
| Orientations Available | <100>, <110>, <111> (±0.5° tolerance) |
| Standard Dimensions | Ø2" × 0.5 mm, 10 × 10 × 0.5 mm, 10 × 5 × 0.5 mm |
| Surface Finish | Single- or Double-Polished, Ra < 5 Å |
| Packaging | Class 1000 Cleanroom Assembly, Sealed in Class 100 Clean Bags or Individual Protective Cassette Boxes |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HQ-10-pH |
| Instrument Type | Pen-style |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.07 pH |
| Repeatability | ±0.08 pH |
| Temperature Compensation Accuracy | ±0.04 pH |
| Response Time | 15 s |
| Offset at pH 4.00 | −0.02 pH |
| Offset at pH 6.86 | +0.03 pH |
| Offset at pH 9.18 | −0.05 pH |
| Output Interface | RS485 with Modbus RTU protocol |
| Enclosure Rating | IP68 |
| Housing Material | Stainless Steel (316L) |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HQ100-COD-STD |
| Price | Upon Request |
| Measurement Principle | UV254 nm Absorption Spectrophotometry |
| Range | 0–500 mg/L COD |
| Accuracy | ≤ ±10% FS |
| Resolution | 0.01 mg/L |
| Optical Path Length | 20 mm |
| Compensation Method | Dual-beam turbidity compensation at 546 nm |
| Response Time | ≤30 s (adjustable) |
| Output Interface | RS485 with Modbus RTU protocol |
| IP Rating | IP68 |
| Integrated Features | Simultaneous measurement of COD, turbidity, Specific UV Absorbance (SAC), and temperature |
| Cleaning Mechanism | Motor-driven mechanical wiper with programmable cleaning intervals |
| Power Supply | 12–24 VDC |
| Operating Temperature | 0–50 °C |
| Housing Material | Corrosion-resistant stainless steel (316L) and PEEK |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HQ11-TA5030 |
| Pricing | Upon Request |
| Brand | ZOEX |
|---|---|
| Origin | USA |
| Model | GC×GC×HiResTOFMS |
| Configuration | Agilent 8890 GC Platform + QTOF HiRes TOFMS Detector |
| Modulator Type | Dual-Stage Thermal Modulator (ZX-1 or ZX-2) |
| Software | GC Image™ v2.9+ with HRMS Extension |
| Compliance | Fully compatible with ASTM D7504, ASTM D7901, ISO 17993, and USP <1225> for method validation |
| Brand | ZOEX |
|---|---|
| Origin | USA |
| Model | ZX-1 / ZX-2 |
| Cooling Method | Liquid Nitrogen or Electronic Cryogenic Cooling |
| Modulation Principle | Dual-Stage Thermal Jet Modulation |
| Compatibility | Agilent, Shimadzu, Thermo Fisher, and Other Standard GC Platforms |
| Interface | Non-destructive, GC-native mounting |
| MS Coupling | Compatible with Quadrupole GC-MS, TOF-MS, and High-Resolution Mass Spectrometers |
| Peak Capacity Enhancement | >10× vs. 1D-GC |
| Minimum Detectable Volatility | C4 hydrocarbons (with LN₂ cooling) |
| Regulatory Alignment | Designed for GLP-compliant laboratories |
| Brand | Zoeyun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Sample Capacity | 64 Positions |
| Heating Zones | 4 Independent Zones (Desorption Chamber, Injection Valve, Transfer Line, Secondary Desorption Trap) |
| Cooling Method | Electronic Peltier Cooling (No Liquid Nitrogen Required) |
| Sample Tube Material Compatibility | Standard 1/4" OD Stainless Steel or Silica Tubes |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Leak Detection | Automatic Tube Integrity Check |
| Interface | GC/GC-MS Synchronization with Start/Stop & Remote Control Signal Support |
| Software Features | Method Programming, Queue Management, Audit Trail, Event Logging, Tube Aging & Calibration Simulation |
| Compliance Standards | ASTM D6196, ISO 16017-1, US EPA TO-17, HJ 583–2010, HJ 644–2013, HJ 734–2014, GB/T 18883–2022, GB 50325–2020 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Single-beam Czerny-Turner monochromator with 1800 lines/mm holographic grating |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 1.0 / 2.0 nm (5-step auto-switching) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Baseline Stability | ≤0.003 A/30 min (dynamic), ≤0.002 A/30 min (static) |
| Resolution | <0.1 nm |
| Flame Cu Detection Limit | ≤0.003 µg/mL |
| Flame Cu Characteristic Concentration | ≤0.02 µg/mL/1% |
| Graphite Furnace Cd Characteristic Mass | 0.3×10⁻¹² g |
| Graphite Furnace Detection Limit | 0.2×10⁻¹² g |
| Graphite Furnace Temperature Range | Room temperature to 3000 °C |
| Max. Graphite Furnace Ramp Rate | ≥3000 °C/s (optical control), ≥2000 °C/s (power control) |
| Background Correction | D₂-lamp and self-absorption (AAS) modes, correction capacity >60× at 1.0 A background absorbance |
| Sample Introduction | Manual or automated (flame/graphite furnace/hydride generation) |
| Dimensions (W×D×H) | 880 × 540 × 450 mm |
| Weight | 125 kg |
| Power Supply | AC 220 V, 50 Hz |
| Main unit | 500 W |
| Graphite furnace module | 5 kW |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Czerny-Turner grating monochromator with 1800 lines/mm grating |
| Optical System | Single-beam |
| Background Correction | Deuterium lamp + Self-reversal (Self-absorption) background correction |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm (5-step automatic switching) |
| Cu Detection Limit (Flame) | ≤0.003 µg/mL |
| Cd Characteristic Mass (GFAAS) | 0.3×10⁻¹² g |
| Cd Detection Limit (GFAAS) | 0.2×10⁻¹² g |
| Graphite Furnace Temp. Range | Room temperature to 3000 °C |
| Max. Sample Volume (GFAAS) | 70 µL |
| Background Correction Capacity | >60× at up to 1.0 A absorbance |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame-Graphite Furnace Hybrid AAS |
| Background Correction | Dual-mode Deuterium Lamp + Longitudinal AC Zeeman |
| Optical Grating | 1800 lines/mm |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm (auto-switchable) |
| Flame Cu Detection Limit | ≤0.003 µg/mL |
| Graphite Furnace Cd Characteristic Mass | 0.5×10⁻¹² g |
| Graphite Furnace Detection Limit | 10×10⁻¹² g |
| Max Graphite Furnace Temp | 2700 °C |
| Heating Rate | ≥2500 °C/s |
| Background Correction Capacity | >60× (flame, D₂), >100× (GF, Zeeman at ~2.0 Abs) |
| Auto-sampler Compatibility | AS-600 Integrated Flame/GF Autosampler |
| Software Compliance | Audit Trail, Electronic Signature, Role-Based Access Control, 21 CFR Part 11 Readiness |
| Brand | ZOLIX |
|---|---|
| Model | BFC Series |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Chame-3000 |
| Pricing | Upon Request |
| Spectral Range | 380–780 nm |
| Measurement Speed (Optical) | 30 ms |
| Measurement Speed (Electrical) | 20–120 ms (model-dependent) |
| Voltage Range | 0–10.00 V |
| Current Range | 0–500 mA (SL series), up to ±1500 mA (SH series) |
| Luminous Intensity Sensitivity | 5 mcd – 30,000 mcd |
| Colorimetric Accuracy (x,y) | ±0.005 |
| Dominant Wavelength Accuracy | ±1 nm |
| IV Repeatability | ±2% |
| Spectral Resolution | 1 nm |
| Interface | USB 2.0 |
| Power Supply | USB 2.0 or DC 5 V |
| Dimensions | 140 × 80 × 180 mm |