| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Domestic |
| Model | VIS 721 |
| Optical System | Achromatic Czerny-Turner (1200 L/mm grating) |
| Wavelength Range | 350–1020 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ≤1 nm |
| Spectral Bandwidth | 6 nm |
| Photometric Accuracy (Transmittance) | ±1% T |
| Photometric Stability | ±0.004 A/h @ 500 nm |
| Drift | ≤0.2% T |
| Noise | ≤0.3% T |
| Stray Light | ≤0.3% T @ 360 nm |
| Detector Type | Silicon Photocell |
| Wavelength Adjustment | Manual |
| Sample Compartment | Accommodates up to 10 cm pathlength cuvettes |
| Display | Digital LED |
| Zero & 100% T Calibration | Automatic |
| Optional Interface | RS232 for printer or PC connectivity |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1020 nm |
| Wavelength Selection | Manual (Knob-Actuated) |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.3% T at 360 nm |
| Photometric Accuracy | ±0.5% T |
| Wavelength Repeatability | ≤1 nm |
| Baseline Stability | ±0.004 A/h at 500 nm |
| Drift | ≤0.1% T |
| Noise | ≤0.2% T |
| Photometric Modes | Transmittance (%T), Absorbance (A), Concentration (C) |
| Light Source | Imported Tungsten-Halogen Lamp |
| Sample Compartment Dimensions | Accommodates up to 10 cm pathlength cuvettes |
| Interface Options | Optional RS-232 Serial Port for Printer or PC Connectivity |
| Net Weight | 8 kg |
| Optical System | Achromatic Czerny-Turner Monochromator with 1200 lines/mm Grating |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Domestic |
| Model | VIS-722N |
| Optical System | Achromatic Czerny-Turner with 1200 L/mm Grating |
| Wavelength Range | 320–1020 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 4 nm |
| Photometric Accuracy (Transmittance) | ±0.5% T |
| Photometric Linearity | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Baseline Stability | ±0.002 A/h @ 500 nm |
| Drift | ≤0.1% T |
| Noise | ≤0.2% T |
| Stray Light | ≤0.2% T @ 360 nm |
| Detector Type | Silicon Photocell |
| Light Source | Imported Tungsten-Halogen Lamp |
| Sample Chamber Dimensions | Accommodates up to 10 cm pathlength cuvettes |
| Operating Modes | Transmittance (T), Absorbance (A), Concentration (C) |
| Zeroing Method | Automatic |
| Interface Options | Optional RS-232 Serial Port for Printer/PC Connectivity |
| Net Weight | 8 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 320–1100 nm |
| Wavelength Automation | Motorized Auto-Scan |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.1%T at 360 nm |
| Wavelength Repeatability | ±0.5 nm |
| Photometric Accuracy | ±0.5%T |
| Photometric Repeatability | ±0.2%T |
| Photometric Range | 0–200%T, −0.301–3.000 A |
| Baseline Linearity | ±0.004 A |
| Drift Stability | ±0.002 A/h @ 500 nm |
| Display | 128×64 Dot-Matrix LCD |
| Light Source | Imported Tungsten Halogen Lamp |
| Sample Compartment Size | Accommodates Cuvettes from 5 mm to 100 mm Pathlength |
| Net Weight | 12 kg |
| Software Compatibility | YOKE 3.0 PC Control & Data Analysis Suite |
| Warranty | 12-month Limited Hardware Warranty with Lifetime Technical Support |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ZD-2A |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Range | −2.00 to 20.00 pH |
| mV Range | −1999 to +1999 mV |
| Temperature Measurement Range | −5.0 to 105.0 °C |
| pH/mV Accuracy | ±0.03 pH / ±5 mV |
| Temperature Accuracy | ±0.3 °C |
| pH/mV Resolution | 0.01 pH / 1 mV / 0.1 °C |
| Input Impedance | ≥1 × 10¹¹ Ω |
| Input Current | ≤6 × 10⁻¹² A |
| Stability | (±0.3 mV ±1 digit)/3 h |
| Endpoint Sensitivity | ±0.1 pH or ±5 mV |
| Relative pH Precision | ±0.03 pH |
| Titration Repeatability | 0.2% |
| Data Storage Capacity | 2000 records |
| Storage Content | Sample Name, Endpoint Value, Concentration, Date & Time |
| Operating Environment | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ZD-3A |
| Instrument Category | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Range | −2.00 to 20.00 pH |
| mV Range | −1999 to +1999 mV |
| Temperature Measurement Range | −5.0 to 105.0 °C |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.03 pH |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.3 °C |
| Input Current | ≤2 × 10⁻¹² A |
| Input Impedance | ≥3 × 10¹² Ω |
| Stability (Electronic Unit) | (±0.3 mV ±1 digit)/3 h |
| Endpoint Setting Range | −2.00–20.00 pH or −1999–+1999 mV |
| Titration Control Sensitivity | ±0.1 pH or ±5 mV |
| Repeatability (Volumetric Analysis) | 0.2% |
| Data Storage Capacity | 2000 records |
| Storage Content | Sample name, endpoint value, concentration, date & time |
| Operating Environment | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Brand | YOKO |
|---|---|
| Model | BD-II |
| Type | Electric Thin-Layer Chromatography Spotter |
| Spotting Mode | Contact-based circular spotting |
| Max Plate Size | 200 × 200 mm |
| Heating Platform Power | 600 W |
| Temperature Control Range | 0–200 °C (digital display & setpoint control) |
| Heating Stage Travel | 0–180 mm (bidirectional, stepper motor-driven with auto-limit protection) |
| Syringe Drive | Stepper motor actuation with downward行程 auto-protection |
| Syringe Options | 10 µL and 50 µL glass microsyringes included |
| Spotting Accuracy | < 1.0% RSD |
| Spotting Reproducibility | < 1.5% RSD |
| Sample Uptake | Direct capillary aspiration (bubble-free operation) |
| Cleaning | Removable syringe for manual cleaning |
| Input Power | 630 W, 220 V ± 10%, 50–60 Hz |
| Heating Platform Material | Stainless steel |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Model | YOKO-PN+PX |
| Instrument Type | Preparative Thin-Layer Chromatography System |
| Operation Mode | Automatic |
| Wavelength Range | 200–700 nm |
| Wavelength Accuracy | ±1 nm |
| Power (PN-I) | 50 W |
| Airflow (PN-I) | 65 L/min |
| Noise Level (PN-I) | <48 dB(A) |
| Dimensions (PN-I) | 207 × 142 × 215 mm |
| Power (PX-II-A) | 50 W |
| Airflow (PX-II-A) | 5000 L/min |
| Dimensions (PX-II-A) | 480 × 480 × 420 mm |
| Construction | Full Stainless Steel Enclosure |
| Exhaust Fan | Centrifugal Type |
| Duct Diameter | Φ150 mm × 2 m Extendable Hose |
| Brand | whYOKO |
|---|---|
| Model | YOKO-PX |
| Type | Manual Prep-TLC Spray Development Chamber |
| Construction | All-Stainless-Steel Enclosure |
| Exhaust System | Centrifugal Duct Fan |
| Exhaust Capacity | 5000 L/min (PX-A) / 8300 L/min (PX-B) |
| Dimensions | 460 × 460 × 460 mm (PX-A) / 500 × 500 × 500 mm (PX-B) |
| Duct | φ150 mm × 2 m telescopic stainless-steel flex duct with fittings |
| Power | 50 W (PX-A) / 90 W (PX-B) |
| Compliance | Designed for ISO/IEC 17025-aligned lab safety workflows |
| Application | Post-development spray reagent application and acid carbonization in thin-layer chromatography |
| Brand | YOKO |
|---|---|
| Model | TD-1 |
| Origin | Hubei, China |
| Type | Electrospray-based linear applicator for thin-layer chromatography (TLC) |
| Sample Delivery | Non-contact pneumatic spray |
| Spot/Strip Modes | Single-spot, multi-spot, continuous linear strip (0–180 mm) |
| Maximum Plate Size | 200 × 200 mm |
| Heating Platform | Stainless steel, 35–200 °C (±0.5 °C stability), 600 W |
| Motion Control | Synchronous stepper motors with end-stop protection (X-axis translation, Z-axis needle actuation) |
| Syringe Compatibility | 10 µL, 50 µL standard |
| Accuracy | <1.0% RSD |
| Precision (repeatability) | <1.5% RSD |
| Air Supply | Oil-free compressor, 0–0.12 MPa adjustable, gas flow 0.1–2.0 L/min |
| Power | 220 V ±10%, 50–60 Hz, 630 W |
| Dimensions (L×W×H) | 400 × 390 × 290 mm |
| Weight | 16 kg |
| Brand | YOKO |
|---|---|
| Model | XR-I |
| Type | TLC Development & Visualization Heater |
| Operation Mode | Automatic Temperature Control |
| Heating Surface | 210 × 210 mm Stainless Steel |
| Temperature Range | 0–200 °C (Digital PID Control) |
| Temperature Accuracy | ±1 °C |
| Power Supply | AC 220 V, 50/60 Hz |
| Power Consumption | 600 W |
| Dimensions (W × D × H) | 240 × 240 × 150 mm |
| Net Weight | 2.5 kg |
| Wavelength Range for Visualization Support | 200–700 nm |
| Compliance | CE-marked design principles |
| Software Interface | None (standalone hardware unit) |
| Brand | YOKO |
|---|---|
| Model | YOKO-2000 |
| Origin | Hubei, China |
| Instrument Type | TLC Scanner |
| Operation Mode | Automatic |
| Measurement Modes | Reflectance, Fluorescence |
| Wavelength Range | 200–700 nm |
| Light Source | UV Lamp |
| Wavelength Accuracy | ±1 nm |
| Minimum Resolution | 10 µm |
| Imaging Wavelengths | 254 nm, 365 nm |
| Sample Stage | 100 mm × 200 mm Pre-coated TLC Plates |
| Brand | YOKO |
|---|---|
| Model | YOKO-2002 |
| Instrument Type | Preparative Thin-Layer Chromatography Imaging System |
| Operation Mode | Automatic |
| Detection Method | Fluorescence and Reflectance |
| Wavelength Range | 200–700 nm |
| Light Source | UV (254 nm & 365 nm) and Visible |
| Monochromator | Fluorescence Linear Scanning |
| Spectral Bandwidth | 6 mm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Minimum Spatial Resolution | 10 µm |
| Imaging Wavelengths | 254 nm, 365 nm |
| Sample Stage Dimensions | 200 × 200 mm |
| Maximum Scan Speed | 100 mm/s |
| Quantitative Algorithms | Normalization, Internal Standard, External Standard (Single-Point Linear, Two-Point Quadratic) |
| Software Platform | Windows XP/2000/NT |
| Regulatory Compliance | Designed to support USP <621>, EP 2.2.27, and ChP monograph requirements for TLC densitometry |
| Brand | YOKO |
|---|---|
| Model | YOKO-2005 |
| Origin | Hubei, China |
| Instrument Type | TLC Scanner |
| Operation Mode | Automatic |
| Detection Modes | Reflectance, Fluorescence (Transmittance optional) |
| Wavelength Range | 200–720 nm |
| Minimum Spatial Resolution | 10 µm |
| Sample Stage | 10 × 20 cm Pre-coated TLC Plates |
| Brand | YOKO |
|---|---|
| Model | YOKO-3000 |
| Origin | Hubei, China |
| Instrument Type | TLC Scanner |
| Operation Mode | Automatic |
| Measurement Modes | Reflectance, Fluorescence, Absorption |
| Wavelength Range | 200–800 nm |
| Light Sources | Tungsten-Halogen Lamp & Deuterium Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Minimum Spatial Resolution | 10 µm |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Scan Speed | 50 mm/s |
| Baseline Flatness | ±1% |
| Interface | USB 2.0 |
| Power Supply | 220 V AC, 300 W |
| Operating System Compatibility | Windows 2000/XP |
| Brand | YOKO |
|---|---|
| Model | YOKO-AD |
| Instrument Type | TLC Sample Spotter |
| Spotting Method | Contactless Pneumatic Spray & Precision Syringe Deposition |
| Programmable Methods | 50 (100 steps each) |
| Spotting Accuracy | ≥99% |
| Spotting Reproducibility | ≥99% |
| Heating Platform | 0–200 °C, Digital PID Control, Max Plate Size 200 × 200 mm |
| Spotting Range | 0 mm (point) to 190 mm (band/strip) |
| Syringe Options | 10, 25, 50, 100, 500 µL |
| Air Supply | Oil-Free Compressor, 0–0.12 MPa, Flow Rate 0.1–2.0 L/min |
| Power | 220 V ±10%, 50–60 Hz, 650 W |
| Dimensions | 500 × 400 × 330 mm |
| Weight | 18 kg |
| Brand | YOKO |
|---|---|
| Origin | Hubei, China |
| Model | YOKO-FD1 |
| Spotting Mode | Contactless Pneumatic Spray & Precision Needle Deposition |
| Programmable Methods | 50 (100 steps each) |
| Heating Platform | 0–200 °C, 200 × 200 mm stainless steel |
| Spotting Accuracy | ≥99% |
| Spotting Reproducibility | ≥99% |
| Syringe Options | 10 µL, 50 µL (standard) |
| Air Supply | Oil-free compressor, 0–0.12 MPa adjustable, gas flow 0.1–2.0 L/min |
| Dimensions | 480 × 420 × 390 mm |
| Weight | 20 kg |
| Power | 220 V ±10%, 50–60 Hz, 650 W |
| Brand | YOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Preparative Thin-Layer Chromatography (TLC) Imaging System |
| Operation Mode | Manual |
| UV Wavelengths | 254 nm, 365 nm |
| Visible Light Source | Standard White Light (6 W, GB-compliant) |
| UV Lamp Configuration | Dual 254 nm (6 W each), Dual 365 nm (6 W each), Dual White Light (6 W each) |
| UV Transmittance | ≥68% at 254 nm, ≥86% at 365 nm |
| Filter Dimensions | 50 × 200 mm (2 pcs) |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Total Power Consumption | 36 W |
| Dimensions (L×W×H) | 400 × 390 × 290 mm |
| Weight | Not specified |
| Brand | YOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YOKO-CS |
| Instrument Type | TLC Imaging System |
| Operation Mode | Manual |
| UV Lamps | 254 nm (2 × 12 W), 365 nm (2 × 12 W), 312 nm (5 × 20 W), All at 220 V / 50 Hz |
| Visible Light | GB-standard daylight lamps (2 × 12 W) |
| UV Transmission Filters | Two 50 × 200 mm filters (for reflected UV), One 150 × 200 mm filter (for transmitted UV) |
| Power Supply | 220 V AC, 50 Hz |
| Ballast | High-efficiency electronic ballast (instant start) |
| Brand | YOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | YOKO-IA |
| Instrument Type | TLC Developing Chamber Accessory |
| Operation Mode | Manual |
| Input Voltage Range | 100–220 V AC |
| Rated Voltage | 220 V AC |
| Power Consumption | 60 W |
| Heating Platform | Anodized Aluminum Base with Stainless Steel Surface |
| Temperature Control | Continuously Adjustable via Potentiometer |
| Brand | Yokogawa |
|---|---|
| Model | AQ6370D |
| Wavelength Range | 600–1700 nm |
| Wavelength Accuracy | ±0.01 nm |
| Wavelength Resolution | 0.02 nm |
| Dynamic Range | 78 dB (typ.) |
| Power Range | +20 to −90 dBm |
| Sweep Time | 0.2 s (for 100 nm span) |
| Fiber Compatibility | Single-mode and multimode fiber |
| Origin | Japan (manufactured in Yokogawa facilities |
| Brand | York |
|---|---|
| Model | DPT-70 |
| Type | Portable Dew Point Meter |
| Principle | Capacitive Polymer Sensor |
| Measurement Range | -70 to +30 °C (Dew Point) |
| Resolution | 0.01 °C (DP) |
| Accuracy | ±2.0 °C (DP) |
| Response Time (T90) | <120 s |
| Operating Temperature | -10 to +60 °C |
| Sample Pressure Range | 0–20 bar (absolute) |
| Power Supply | Rechargeable Li-ion Battery (220 VAC charger included) |
| Weight | 0.7 kg |
| Dimensions (Handheld Unit) | 250 × 70 × 25 mm |
| Display | Backlit LCD with Multi-parameter Readout |
| Data Logging | Internal storage with USB export to Excel-compatible CSV format |
| Brand | York Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DPSS-6100 |
| Product Type | Online Dew Point Analyzer Sampling System |
| Measurement Principle | Capacitive Polymer Sensor-Based Dew Point Detection |
| Pressure Rating | Up to 20 MPa (for integrated pressure regulator) |
| Filtration Precision | 2 µm (stainless steel sintered filter element) |
| Flow Control Range | 0–2 L/min (adjustable via precision needle valve) |
| Compliance Standards | GB 50029-2014 (Compressed Air Station Design Code), GB 50093-2013 (Code for Construction and Quality Acceptance of Automation Instrumentation Engineering), GB 50030-2013 (Oxygen Station Design Code) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | York Instrument |
| Product Type | Import |
| Model | FGS |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YKDC220 |
| Application | Laboratory-grade dew point calibration system |
| Measurement Principle | Chilled-mirror hygrometry |
| Operating Temperature | 20–25 °C |
| Accuracy | ±0.1 °C (dew point) |
| Repeatability | ±0.1 °C (dew point) |
| Dry Gas Generator | GS-1000 with PSA drying |
| Minimum Achievable Dew Point | ≤ −80 °C |
| Input Pressure | ≥ 0.8 MPa |
| Output Pressure Range | 0–0.3 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (W×D×H) | 485 × 500 × 260 mm |
| Weight | 20 kg |
| Interface | RS485 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DM9200 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled Mirror Condensation |
| Operating Temperature Range | −30 to +90 °C |
| Accuracy | ±0.15 °C |
| Repeatability | ±0.05 °C |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Condensation |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±0.1 °C (dew point) |
| Repeatability | ±0.05 °C (dew point) |
| Display | High-Resolution Capacitive Touch LCD |
| User Interface | Graphical, Multilingual (English/Chinese), Step-by-Step Guidance |
| Mirror Control | Digital Fuzzy Logic with Auto-Balance Algorithm |
| Mirror Maintenance | Integrated Mirror Inspection and Automated Cleaning Sequence |
| Diagnostics | Real-Time Self-Diagnostic Engine with Fault Classification |
| Communication Interfaces | RS-485, USB 2.0 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | -70 °C to +20 °C |
| Resolution | 0.01 °C |
| Response Time | ≤60 s (for 10 °C step change) |
| Mirror Material | Chromium-Plated Copper |
| Flow Rate Range | 0–2 L/min (accuracy ±5%) |
| Pressure Sensor Range | 0–200 kPa (abs), accuracy ±0.25% FS |
| Remote Temperature Sensor | 4-wire PT100, accuracy ±0.1 °C, cable length <2 m |
| Power Supply | 80–264 VAC, 47–63 Hz, 400 W |
| Analog Outputs | 4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V (3-channel, user-configurable) |
| Alarm Outputs | 2 programmable SPDT relays (250 VAC/5 A, 30 VDC/5 A, resistive load) |
| Communication | USB, RS-485, Modbus RTU protocol |
| Data Storage | SD card (FAT32, up to 32 GB) |
| Display | 7" LCD touch screen, 1024×600 RGB WVGA, 16:9 aspect ratio |
| Supported Units | °C, °F, ppmv, ppmw, %RH, g/kg, mg/m³ |
| Sample Gas Temp | -20 °C to +40 °C |
| Sample Gas Pressure | 0–200 kPa (abs) |
| Sample Flow Rate | 0.3–1 L/min |
| Environmental Humidity Limit | <80% RH |
| Storage Temperature | -20 °C to +50 °C (optimal at 20 °C) |
| Dimensions | 190 mm (H) × 483 mm (W) × 498 mm (D) |
| Weight | 15 kg |
| Gas Inlet Fitting | 1/4" stainless steel compression fitting |
| Enclosure Material | Aluminum alloy |
| Gas Path Materials | 316L stainless steel |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | 10–35 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | −90 to +20 °C |
| Resolution | 0.01 °C |
| Response Time | ≤60 s (for ±10 °C step change) |
| Mirror Material | Chromium-Plated Copper |
| Flow Rate Range | 0–2 L/min (±5% FS) |
| Pressure Range | 0–200 kPa (abs), ±0.25% FS |
| Remote Temperature Sensor | 4-wire PT100, ±0.1 °C |
| Display | 9.7" LCD, 1024×768 RGB, 4:3 aspect ratio |
| Analog Outputs | 3-channel configurable (4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V) |
| Digital Interfaces | USB, RS-485 (Modbus RTU) |
| Data Storage | SD Card (FAT32, up to 32 GB) |
| Enclosure | 6U 19″ rack-mountable aluminum chassis (278 × 483 × 578 mm, 40 kg) |
| Gas Inlet/Outlet | 1/4″ VCR (in), 1/4″ stainless steel compression (out) |
| Wetted Materials | 316L stainless steel, chromium-plated copper mirror |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | -10 °C to +35 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | -95 °C to +20 °C (at 20 °C ambient) |
| Display | 9.7" TFT LCD Touchscreen |
| Resolution | 0.01 °C |
| Output Options | 4–20 mA, 0–10 V, RS-485 (Modbus RTU), USB |
| Data Storage | SD Card (FAT32, up to 32 GB) |
| Sample Flow Rate | 0.3–1 L/min |
| Sample Pressure | 0–200 kPa (abs) |
| Sample Temperature | -20 °C to +40 °C |
| Mirror Material | Rhodium-plated Copper |
| Enclosure | Aluminum Alloy |
| Dimensions | 278 mm (H) × 483 mm (W) × 578 mm (D) |
| Weight | 40 kg |
| Power Supply | 198–254 VAC, 47–63 Hz, 1000 W |