Chemical Analysis Instruments
Filter
Showing 1561–1590 of 4495 results
| Brand | ESI/ESL |
|---|---|
| Origin | France |
| Manufacturer | ESL (Elemental Scientific Lasers) |
| Type | Imported |
| Model | ESL193HE |
| Pricing | Upon Request |
| Brand | ESS |
|---|---|
| Origin | United Kingdom |
| Model | Ecosys-P |
| Power Supply | 100–240 V AC, 170 W |
| Battery | 24 V DC, 8 h continuous operation |
| I/O Ports | 4 analog outputs, 2 analog inputs, 2 digital inputs, 2 digital outputs |
| Detection Limit | sub-ppt (parts-per-quadrillion) for selected VOCs |
| Sample Introduction | Integrated thermal desorption unit with long-distance sampling capability |
| Operational Mode | Fully autonomous, unattended field deployment |
| Data Handling | Per-point data file generation, automated reporting, optional auto-calibration |
| Brand | EST |
|---|---|
| Origin | USA |
| Model | Centurion |
| Sample Positions | 100 |
| Injection Precision | RSD < 3% |
| Trap Tube Temperature Range | Ambient to 280 °C |
| Purge Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | 4–10 °C |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3017 |
| Analysis Principle | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0–100% |
| Repeatability | ±0.5% RSD |
| Sample Mass Capacity | ≤5 g (solid) |
| Dimensions (L×W×H) | 480 mm × 480 mm × 600 mm |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3100 |
| Measurable Elements | C, H, N, S, O |
| Analysis Time | CN ≤ 3 min |
| Detection Limit | ppm-level |
| Measurement Accuracy | ±0.1% (relative) |
| Sample Introduction | Tin or silver capsules, filled to capacity |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | TurboFlash dynamic combustion up to 1800 °C |
| Brand | Eutech |
|---|---|
| Origin | USA |
| Model | ORPTEST10 |
| Instrument Type | Laboratory & Field-Portable ORP Meter |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Manual 1-point |
| Electrode Type | Replaceable Double-Junction Ag/AgCl |
| Power Supply | 4 × A76/LR44 batteries |
| Battery Life | >500 hours |
| Auto-Off | 8.5 min idle |
| Operating Temperature | 5–45 °C |
| IP Rating | IP67 |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Dimensions | 16.5 × 3.8 cm |
| Weight | 90 g |
| Data Hold & Low-Battery Indication | Yes |
| Temperature Compensation | None (ORP-only measurement) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher Scientific brand) |
| Type | Portable Multi-parameter Electrochemical Analyzer |
| Model | pH450 |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | Up to 5 (USA/NIST), up to 6 (DIN), or up to 5 user-defined points |
| Buffer Recognition | Automatic (USA/NIST/DIN) |
| Calibration Expiry Alert | Configurable |
| Data Storage | 500 datasets with timestamp (RTC) |
| Connectivity | USB and RS232 |
| Power | 2 × AA batteries (typical life >2000 hours) or optional AC adapter |
| Enclosure Rating | IP67 |
| Electrode Interface | BNC |
| Temperature Unit | °C/°F selectable |
| GLP Compliance | Yes (time-stamped calibration & measurement records) |
| Heating Temperature Range | Ambient to 350 °C |
|---|---|
| Heater Type | Cartridge Heater |
| Max. Sample Volume | <10 mL |
| Carrier Gas | Nitrogen or Dry Air (dry air compressor optional) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 VA |
| Dimensions (W×D×H) | 220 × 430 × 200 mm |
| Weight | Approx. 8 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EV-2000L |
| Pricing | Available Upon Request |
| Moisture Evaporation Method | Azeotropic Distillation with Inert Carrier Gas |
| Heating Range | Ambient to 200 °C |
| Heater Type | Band Heater |
| Max Sample Volume | ≤10 mL |
| Azeotropic Solvent | Toluene or Xylene (5–10 mL per analysis) |
| Carrier Gas | Nitrogen or Dry Compressed Air (optional integrated air dryer/pump available) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve (4 Å) |
| Power Supply | AC 100–240 V, 50/60 Hz, 150 VA |
| Dimensions (W×D×H) | 220 × 370 × 265 mm |
| Net Weight | ~7 kg |
| Brand | Evident (formerly Olympus) / EVDENT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DELTA DPO-2000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous & Specialty Alloys |
| Elemental Range | Mg to U |
| Quantification Range | ppm to wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AION 1000 |
| Pricing | Upon Request |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ATROP-VA |
| Pricing | Available Upon Request |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Nova UC1000 |
| Pricing | Upon Request |
| Brand | EXFORMMA |
|---|---|
| Origin | Hong Kong |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | ARCUS 5 |
| Instrument Type | HPLC/UHPLC Autosampler |
| Sample Capacity | Up to 108 × 2 mL vials (configurable with 10 mL, 4 mL, or 96-well PCR plates) |
| Max Operating Pressure | 40 MPa |
| Injection Volume Range | 0.1–1000 µL (standard configuration: 0.1–120 µL) |
| Syringe Volume | 200 µL (resolution: 0.1 µL) |
| Sampling Modes | Full-loop, Partial-loop, and Needle-into-loop (NIL) / Zero-dead-volume sampling |
| Vial Height Limit | ≤52 mm (including septum and cap) |
| Pump Lifetime | ≥1,000,000 injections |
| Compliance | Designed for GLP/GMP environments |
| Brand | EXFORMMA |
|---|---|
| Origin | Hong Kong |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | EX1800 Ultra-High-Performance Liquid Chromatography (uHPLC) Analytical System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Solvent Inlet Configuration | Dual 2-position/2-way switching valves enabling four independent solvent channels |
| Degasser Channel Volume | 380 µL |
| Pump Type | Dual-plunger reciprocating parallel pump with integrated binary high-pressure mixer |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% |
| Flow Precision (RSD) | < 0.06% at 1 mL/min and 10 MPa |
| Pressure Pulsation | ≤ 0.1 MPa |
| Power Supply | 220 V AC / 110 V AC |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1330 |
| Instrument Type | Portable |
| Detection Principle | Grating-scanning NIR spectroscopy with InGaAs detector |
| Measurement Time | ≤3 s per sample |
| Sample Forms | Granular, flake, and powdered materials |
| Connectivity | Wi-Fi, USB, Bluetooth (optional) |
| Power Supply | AC adapter or optional rechargeable Li-ion battery |
| Compliance | Supports ASTM E1655, ISO 12099, and GB/T 37878–2019 for NIR calibration transfer and performance validation |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 1340 |
| Instrument Type | Online NIR Spectrometer |
| Optical Design | Grating Scanning |
| Application Domain | Feed Production, Grain & Oil Processing, Brewing Industry |
| Measurement Principle | Diffuse Reflectance / Transmission NIR Spectroscopy |
| Sampling Interface | Customizable Process Probe |
| Connectivity | Ethernet, Fiber Optic, 4–20 mA Analog Output |
| Enclosure Rating | IP65 |
| Data Acquisition Rate | 5 Hz |
| Alarm Logic | Dual-level (Primary/Secondary) Thresholding |
| Software Integration | C# DLL for Custom SCADA/MES Integration |
| Built-in Reference Standard | Yes |
| Self-Diagnostic & Auto-Calibration | Yes |
| Compliance Context | Designed for GLP-aligned process analytical technology (PAT) deployment |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1350 |
| Instrument Type | Portable |
| Wavelength Range | 1000–1800 nm |
| Weight | 6 kg |
| Power Supply | DC 19 V or Built-in Rechargeable Lithium Battery |
| Display | Integrated Full-Color LCD with Chinese UI |
| Data Storage | Internal High-Capacity Flash Memory |
| Connectivity | USB 2.0 |
| Software | RIMP (Remote Instrument Management Platform) |
| Sample Interface | Interchangeable Probes for Solids, Powders, Pastes, Tablets, and Liquids |
| Diagnostic Function | Onboard Reference Material & Self-Diagnostic Routine |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 1360 |
| Instrument Type | Portable |
| Compliance | Meets GB/T and ASTM D7462/D8073 for fuel analysis |
| Operating Temperature Range | −5 °C to 50 °C |
| Temperature Control Range | 15–60 °C |
| Temperature Stability | ±0.2 °C |
| Measurement Time | ≤10 s per sample |
| Software Interface | Fully localized Chinese GUI with integrated modeling, calibration, and data management modules |
| Connectivity | Ethernet and Wi-Fi enabled for NIR network integration, remote diagnostics, model updates, and instrument health monitoring |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory-Based NIR Spectrometer |
| Model | EXPEC 1360A |
| Application Scope | Fuel Quality Analysis (Gasoline, Diesel, Biofuels), Onboard & At-Line Deployment |
| Optional Accessories | U-Tube Oscillating Density Meter (±0.0005 g/cm³), Rechargeable Battery Pack (8 h runtime) |
| Compliance Framework | Designed for ASTM D2887, D5292, D7467, ISO 20846, and GB/T 28768-2012 alignment |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EXPEC 1370 |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Detection Principle | Diffuse Reflectance NIR Spectroscopy |
| Typical Measurement Time | ≤10 s per sample |
| Detector | InGaAs Array |
| Optical System | Fixed Grating Monochromator |
| Wavelength Range | 900–1700 nm (standard configuration) |
| Compliance | Designed for GLP-compliant laboratory environments |
| Software | EXPEC NIR Analysis Suite with User Role Management (Admin/Operator/Reviewer) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1380 |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Detector | TEC-Cooled InGaAs |
| Optical System | Holographic Digital Grating |
| Sample Interface | Rotating Sample Carousel (Ø180 mm standard) |
| Measurement Principle | Diffuse Reflectance NIR Spectroscopy (900–1700 nm) |
| Data Acquisition Time | ≤10 s per sample |
| Built-in Computing | Integrated Industrial PC |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capability |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1680 |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Regulatory Compliance | HJ 920-2017, HJ 919-2017 |
| Target Analytes | >50 Inorganic & Organic Gases |
| Integrated Features | Heated Sample Path, Onboard Sampling System, GPS Geotagging, Touchscreen UI, Wi-Fi Connectivity, Auto Temperature Control, Remote Operation Capability |
| Brand | EXPEC / Superspectra Technology |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online FTIR Remote Sensor |
| Design | Open-Path, Non-Contact, Real-Time Chemical Imaging System |
| Core Detector | Stirling-Cooled MCT (Operating at –200 °C) |
| Gas Library Capacity | >400 Target Compounds (TICs, VOCs, Chemical Warfare Agents, Industrial Solvents) |
| Operational Range | Up to 10 km Diameter Coverage |
| Scanning Capability | 360° Azimuthal Rotation, ±30° Vertical Elevation (60° Total Vertical FOV) |
| Imaging Modalities | Simultaneous Visible Video, Thermal IR Imaging, and Quantitative Chemical Mapping |
| Compliance Framework | Designed for EPA Method 320 & ASTM D6348 Alignment |
| Brand | EXPEC / Hangzhou Superspectra Technology Co., Ltd. |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | EXPEC 2000 (Spec. 112) |
| Instrument Type | Laboratory-Scale Gas Chromatograph with Online Monitoring Capability |
| Detection Principle | GC-FID (Gas Chromatography with Flame Ionization Detection) |
| Sample Introduction | Cryogenic Preconcentration + Thermal Desorption for TNMHC |
| Compliance | Technical Specification for Continuous Automatic Monitoring of Ambient Air TNMHC (Trial Version), China National Environmental Monitoring Centre, January 2021 |
| Installation Form | Wall-Mounted Enclosure |
| Onboard Gas Generation | Integrated Hydrogen Generator (for Carrier and Fuel Gas) |
| Detection Limit | ≤20 ppb (as Carbon) |
| Regulatory Alignment | ASTM D6348, ISO 11890-2, US EPA Method 25A, HJ 1012–2018 |
| Brand | EXPEC / Puyu Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EXPEC 2000 (Specification 113) |
| Instrument Type | Online Gas Chromatograph |
| Certifications | Ex d IIB T4 Gb (IEC/EN 60079-1), IP66 |
| Detection Principle | Flame Ionization Detection (FID) |
| Sample Interface | Direct high-flow sampling with heated sample line (180 °C) |
| Response Time (T₉₀) | ≤2 s |
| Operating Environment | Zone 1 hazardous area (ATEX/IECEx compliant) |
| Installation Mode | Outdoor wall-mounted, no analyzer shelter required |
| Compliance | GB/T 16157–1996, HJ 38–2017, HJ 1012–2018 |
| Brand | EXPEC (Supelco Technology) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph with Flame Ionization Detection (GC-FID) |
| Configuration | Full-Heat Trace Sampling System with Integrated Pre-treatment Unit, H₂ Generator, and Zero Air Generator |
| Compliance | Aligned with EPA Method TO-15 / Method 18 and HJ 1012–2018 (China) |
| Design | Intrinsically Safe and Explosion-Proof Options Available |
| Sample Interface | High-Temperature Heated Probe (up to 200 °C), PTFE or Passivated Metal Sampling Line |
| Data Output | Real-time Modbus TCP / OPC UA / 4–20 mA to DCS/SCADA and Environmental Supervision Platforms |
| Brand | EXPEC (Hangzhou Supeltech Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph with FID |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Preconcentration Method | Cryogenic Trapping & Direct Thermal Desorption |
| Sample Handling | Automated Whole-Air Sampling with Integrated Dehumidification and Enrichment |
| Compliance Context | Designed for continuous unattended operation in ambient air monitoring networks compliant with EPA TO-14/TO-15, ISO 16017-1, and China HJ 644–2013 standards |
| Software | Embedded real-time control with audit-trail-capable data acquisition supporting 21 CFR Part 11–compatible user authentication and electronic signatures |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Principle | GC-FID (Direct Method) |
| Sampling Method | Cryogenic Pre-concentration + Thermal Desorption |
| Sample Line Temperature | 120 °C (Heated Line) |
| Compliance | “Technical Specification for Continuous Automatic Monitoring of Non-Methane Hydrocarbons in Ambient Air (Trial)” (CNEMC-Air-2021-61) |
| Safety Features | Automatic H₂ Cut-off upon FID Flame-Out |
| Gas Control | Electronic Pressure Control (EPC) & Electronic Flow Control (EFC) |
| Surface Treatment | Deactivated (Inertized) Gas Pathways |
| Sample Handling | Back-Flush Function to Prevent High-Boiling Residue Carryover |
| Brand | EXPEC Technology |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 |
| Detection Principle | Dual-detector Gas Chromatography (FID + ECD) |
| Target Analytes | CO₂, CH₄, CO, N₂O, SF₆ |
| Compliance | GB/T 31705–2015 |
| Sample Introduction | Quantitative Loop Injection |
| Separation | Dedicated GHG Capillary Column |
| CO/CO₂ Conversion | Ni-Catalyzed Methanizer at Elevated Temperature |
| Detector Configuration | Simultaneous FID (for CH₄, CO-derived CH₄) and ECD (for N₂O, SF₆) |
| Data Output | Continuous Real-Time Concentration Profiles (ppb–ppm range) |
| Operational Mode | Unattended 24/7 Online Monitoring |