Chemical Analysis Instruments
Filter
Showing 1471–1500 of 10661 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | GC-9860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring (Drinking Water Compliance) |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| [Origin | Hebei, China |
|---|---|
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 450 °C → 50 °C |
| Carrier Gas Flow Control | 0–1200 mL/min |
| Carrier Gas Pressure Control | 0–970 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| Column Compatibility | Packed (3–5 mm OD) & Capillary (6-inch standard interface) |
| Dimensions (L×H×W) | 520×480×500 mm |
| Weight | 50 kg |
| Power | 2500 W |
| Voltage | 220 V ±10% |
| Temperature Stability | ±0.1 °C |
| Programmable Steps | 8-stage linear ramp |
| Max Run Time | 6000 min |
| Detector Support | Up to 4 simultaneous (FID/TCD/ECD/NPD/FPD), configurable in series or parallel |
| Data Storage | 20 method sets with full chromatogram recall |
| Display | 5.7″ LCD (320×240), bilingual Chinese/English UI] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GC-9860 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | Universal (Environmental, Petrochemical, Pharmaceutical, Food & Safety, Public Health, Research) |
| Oven Temperature Range | +5 °C to 450 °C |
| Temperature Programming | 8-step linear ramp |
| 升温 Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 450 °C → 50 °C (with dual rear doors) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Compatibility | Packed columns (3–5 mm OD), Capillary columns (standard 6-inch mounting span) |
| Detector Capacity | Up to 4 detectors simultaneously (e.g., dual FID, dual TCD, dual ECD, or mixed configurations) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (γ-BHC) |
| Data Storage | 20 method/data sets on internal FLASH memory |
| Display | 5.7″ LCD (320×240), bilingual Chinese/English interface |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Environmental Analysis |
| Temperature Control Range | Ambient ±8 °C to 450 °C (1 °C increment) |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Oven Cooling | Motor-driven rear door with intelligent stepper control |
| Detector Compatibility | FID, TCD, ECD, FPD, Ni-converter furnace |
| Inlet Configurations | Two independent inlets + one valve inlet |
| Autosampler Ready | Compatible with multi-position liquid autosamplers, headspace samplers, and thermal desorbers |
| Data System | Embedded bidirectional control software with valve timing control (e.g., 6-port, 10-port) |
| Pressure Protection | Automatic power cutoff at carrier gas pressure <0.1 MPa |
| Power | 220 V, 50 Hz, 2000 W |
| Dimensions | 59 × 48 × 49 cm |
| Weight | 40 kg |
| Temperature Zones | 10 independently controlled zones |
| Programmed Temperature | 16-step ramping |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860 |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | GC-9860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Baijiu (Chinese Spirit) Chromatographic Analysis |
| Oven Temperature Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Air Monitoring |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Air Quality Monitoring |
| Oven Temperature Range | 4 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ≤8 min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–450 psi |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–500 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Detection | Dual FID (Flame Ionization Detectors) |
| Column Compatibility | Packed & Capillary (including 50 m × 0.32 mm × 1 µm TVOC-specific column and 2 m × 3 mm benzene-packed column) |
| Included Accessories | ATDS-3420 Thermal Desorber, BF-300E H₂ Generator (99.999%, 0–300 mL/min), BF-2L Zero-Air Generator (oil-free, 0–2000 mL/min), HL-10 Tube Aging Unit, ZM-102B Electronic Soap Film Flowmeter, Tenax-TA & Activated Carbon Sampling Tubes (6 mm), Certified TVOC & Benzene Standard Solutions (10/100/1000 µg/mL)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Safety Testing |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (350→100 °C) | ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GC-9860 |
| Communication Interface | 10/100 Mbps Adaptive Ethernet |
| Max Concurrent Instruments | 5,000 |
| Data Import Format | AIA/CDF (ASTM E1947-compliant) |
| Analog Input Range | ±2.5 V |
| Integration Sensitivity | 0.05 µV·s |
| Minimum Resolution | 1 µV |
| Dynamic Range | 10⁷ |
| Linearity | ±0.005% |
| Repeatability | ±0.005% |
| Sampling Rate | Adjustable from 10 to 50 Hz |
| Peak Detection | Intelligent automated peak identification with baseline correction and deconvolution of co-eluting peaks |
| Quantitation Methods | Normalization, corrected normalization, single-point internal/external standard, multi-point internal/external calibration |
| Software Architecture | Multi-threaded, seat-scalable client-server system |
| Remote Data Export Protocols | HTTP/HTTPS, MODBUS TCP, CANopen, GPRS, 3G, private wireless network |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | 5 °C above ambient to 400 °C |
| Temperature Programming | 8-step linear ramping |
| Max. Heating Rate | 0.1–50 °C/min |
| Cooling Rate | ~6 min from 350 °C to 100 °C |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Temperature Range | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Column Compatibility | Packed columns (3–5 mm OD), capillary columns (standard 6-inch mounting span) |
| Detectors Supported | Up to four simultaneous (FID, TCD, ECD, FPD, NPD) |
| Data Storage | 20 method/data sets onboard |
| Display | 5.7″ LCD (320×240), bilingual Chinese/English interface |
| Power Supply | 220 V ±10%, 2500 W |
| Dimensions (L×H×W) | 520×480×500 mm |
| Net Weight | 50 kg |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Operating Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860-FID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Alcoholic Beverage Chromatography |
| Oven Temperature Range | 450 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Time | ~8 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9860-IV-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Food Safety Testing |
| Oven Temperature Range | 450 °C |
| Maximum Ramp Rate | 80 °C/min |
| Maximum Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0.4–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860-VI |
| Temperature Control Range | Ambient to 450 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~8 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Method | Flame Ionization Detection (FID) |
| Sample Introduction | Automated Headspace Sampling (AHS-20A Plus) |
| Compliant Standard | GA/T 842–2019 (China Public Security Industry Standard for Blood Alcohol Testing) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific |
| Temperature Control Range | Up to 450 °C |
| Maximum Ramp Rate | 50 °C/min |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 sccm |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–1200 sccm |
| Key | Brand: Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical & Cosmetic Quality Control |
| Max Oven Temperature | 450 °C |
| Heating Rate | 0.1–80 °C/min |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range | 0–1200 sccm |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–0.4 MPa |
| Injector Total Flow Set Range | 0–1200 sccm |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860 with FID Detector + AHS-610 Headspace Sampler |
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Temperature Control Range | 450 °C |
| Oven Ramp Rate | 39 °C/min |
| Oven Cool-down Rate | 35 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–450 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–450 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Key | Brand: Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Temperature Control Range | Ambient to 400 °C |
| Maximum Ramp Rate | 39 °C/min |
| Cooling Rate | 50 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (Electronic Flow Control) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (Electronic Pressure Control) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860HP |
| Temperature Control Range | 100–450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-down Time | ~7 min (from 450 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–400 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–400 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Detection Method | Flame Ionization Detection (FID) |
| Column Compatibility | Capillary columns (e.g., 30 m × 0.32 mm × 0.5 µm LZP-930) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860HP |
| Temperature Control Range | 100–450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Cool-down Time | ~7 min (from 450 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–400 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–400 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Number of Temperature-Controlled Zones | 6 |
| Max Programmed Temperature Ramps | 8 steps |
| Detection Modes | FID, TCD, ECD, FPD, NPD (configurable up to 3 detectors) |
| Data Interface | IEEE 802.3 Ethernet |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Maximum Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860II |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | Up to 40 °C/min |
| Oven Cool-down Rate | Up to 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860II |
| Temperature Control Range | 4–450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 450 °C → 50 °C |
| Carrier Gas Pressure Control Range | 0–60 kPa |
| Carrier Gas Flow Control Range | 0–60 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–60 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 6 independent zones |
| Programmed Temperature Ramping | up to 8 steps |
| Detection Options | FID, TCD, ECD, FPD, NPD (up to 3 detectors simultaneously) |
| Interface | IEEE 802.3 Ethernet |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GC-9860Ⅲ |
| Temperature Control Range | 8 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Cool-down Time | ~7 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Control | 8 pressure steps |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Temperature Zones | 6 independent zones |
| Programmable Temperature Ramps | 16 stages |
| EPC/EFC Modes | Constant Flow, Constant Pressure, Split Flow |
| Supported Gases | N₂, H₂, Air, He, Ar |
| EPC/EFC Ramp Stages | 4 |
| Detector Options | FID, TCD, ECD (⁶³Ni), FPD, NPD |
| FID Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥4000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/s |
| Communication Interface | IEEE 802.3 Ethernet |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GC-9860III/AHS-610 |
| Temperature Control Range | 450 °C |
| Oven Ramp Rate | 39 °C/min |
| Oven Cool-down Rate | 39 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–450 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–450 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9860IV |
| Temperature Control Range | Up to 350 °C |
| Maximum Oven Ramp Rate | 22 °C/min |
| Maximum Cooling Rate | 410 °C/min |
| Carrier Gas Flow Range & Control | 0–562 mL/min (EPC) |
| Carrier Gas Pressure Range & Control | 0–485 kPa (EPC) |
| Injector Max Temp | 350 °C |
| Injector Pressure Setting Range | 0–512 kPa |
| Injector Total Flow Setting Range | 0–846 mL/min |
| Detectors Supported | FID, TCD, ECD, FPD, NPD |
| Temperature Zones | 6 independently controlled |
| Programmed Temperature Ramping | 16 steps |
| EPC/EFC Modes | Constant Flow / Constant Pressure |
| Supported Carrier Gases | N₂, H₂, He, Ar, Air |
| Communication Interface | Ethernet (IEEE 802.3) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Method | Flame Ionization Detection (FID) |
| Column Configuration | Capillary Column (30 m × 0.25 mm × 0.25 µm) |
| Headspace Autosampler | AHS-20A (20-position) |
| Application Field | Food Industry–Specific Solvent Residue Testing |
| Compliance Standard | GB/T 5009.262–2016 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GC2010+AHS-610 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cool-down Time | ~10 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Model | GC9860-5U |
| Price Range | USD 4,200 – 7,000 (FOB Beijing) |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Cool-down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 6 independently controlled |
| Programmed Temperature Ramping | Up to 16 steps |
| EPC/EFC Capabilities | Dual-mode (constant pressure / constant flow), supports N₂, H₂, Air, He, Ar |
| Pressure Accuracy | ±0.01 kPa |
| Flow Accuracy | ±0.01 sccm |
| Detector Options | FID, TCD, ECD, NPD (up to 3 simultaneously) |
| Data Interface | Ethernet (IEEE 802.3) |
| Display | 192×64 dot-matrix LCD or optional 7-inch industrial tablet |