Chemical Analysis Instruments
Filter
Showing 1501–1530 of 10661 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Model | GC9860-IV |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Cooling Rate | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Accuracy | ±0.05 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | ±0.05 kPa |
| Total Injector Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 6 independent zones |
| Temperature Increment | 1 °C |
| Temperature Stability | ±0.1 °C |
| Programmed Temperature Steps | 16 |
| External Events | 8 channels |
| Auxiliary Outputs | 4 channels |
| Supported Inlet Types | Packed column, capillary column, 6-port gas valve, headspace auto-sampler |
| Detector Capacity | Up to 3 simultaneous detectors |
| Compatible Detectors | FID, TCD, ECD, FPD, NPD |
| Gas Control Mode | Full Electronic Pressure Control (EPC) |
| EPC Operating Modes | Constant Flow, Constant Pressure |
| Supported Carrier Gases | N₂, H₂, Air, He, Ar |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SE2 |
| Application | Field and Laboratory Quantitative Determination of Chlorine Dioxide in Water Samples |
| Light Source | 520 nm LED |
| Optical Stability | ±0.005 Abs/20 min |
| Detection Limit | 0.02 mg/L |
| Measurement Range | 0.00–3.00 mg/L |
| Measurement Time | 1 minute |
| Accuracy | ±5% |
| Power Supply | DC 9 V battery |
| Auto Power-Off | After 30 minutes idle |
| Battery Status Indicator | Integrated low-battery diagnostic circuit |
| Compliance | GB/T 5750.11–2006 (Standard Method for Examination of Disinfectants in Drinking Water) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SN |
| Application | Field-deployable photometric analyzer for residual and total chlorine in water |
| Detection Method | DPD colorimetric method per GB/T 5750.11–2006 |
| Detection Time | ≤3 min |
| Detection Range | 0.00–9.99 mg/L Cl₂ |
| LOD | 0.10 mg/L |
| Accuracy | ±5% of reading |
| Power Supply | 9 V alkaline battery (≥40 h continuous operation) |
| Reagent Format | Single-use, pre-packaged DPD reagent kits (50 tests per kit) |
| Included Accessories | Complete set of calibrated colorimetric cuvettes and reagents (50 tests) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SN2 |
| Application | Quantitative residual chlorine analysis in water samples |
| Detection Method | DPD colorimetric method per GB/T 5750.11–2006 |
| Detection Time | ≤3 minutes |
| Detection Range | 0.00–5.00 mg/L |
| Lower Detection Limit | 0.05 mg/L |
| Accuracy | ±5% of reading |
| Power Supply | 9 V alkaline battery (operating life: ≥40 hours) |
| Reagent Format | Single-use, pre-packaged DPD reagent kits (50 tests per kit) |
| Accessories Included | Complete set of calibrated colorimetric cuvettes and reagents (50 tests) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SV |
| Application | Quantitative sulfide analysis in drinking water, surface water, domestic wastewater, and treated effluent |
| Detection Method | Colorimetric (methylene blue method per GB/T 5750.5–2006) |
| Detection Time | ≤10 min |
| Detection Limit | 0.02 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Power Supply | 9 V alkaline battery (operational life ≥40 h) |
| Reagent Format | Single-use, pre-packaged assay kits (50 tests per kit) |
| Included Accessories | Complete set of colorimetric glassware and reagents (50 assays) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Oven Temperature Range | 40–220 °C (±1 °C stability) |
| Loop Volume | 1 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-2001 |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HL-10A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 10 tubes |
| Tube Dimensions | 6.35 mm (1/4″) OD × ≥88.9 mm (3.5″) L |
| Control Accuracy | ±1 °C |
| Max Aging Duration | >999 h |
| Simulated Sampling Time | 0–99 min |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | <200 W |
| Dimensions (H×W×D) | 225 × 265 × 345 mm |
| Net Weight | 10.5 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HL-10A |
| Price | USD 1,920 (approx.) |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 10 tubes |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Model | HP-6900N |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Count | Not Applicable |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP-6900N |
| Instrument Type | Dual-stage Thermal Desorber |
| Cryo-trap Temperature Range | −35 °C to ambient, 1 °C increments |
| Desorption Temperature Range | Ambient to 350 °C, 1 °C increments |
| Valve & Transfer Line Temp Range | Ambient to 220 °C, 1 °C increments |
| Temperature Control Accuracy | < ±0.5 °C |
| Adsorption Flow Rate | 0–300 mL/min (adjustable) |
| Desorption Recovery Rate | >90% |
| Sample Position Count | 1 |
| Dimensions | 400 × 220 × 420 mm |
| Power Consumption | ~300 W |
| Weight | ~20 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Model | HP-6900N |
| Desorption Zone Temp Range | Ambient to 350 °C (1 °C increments, ramp rate >2000 °C/min) |
| Valve & Transfer Line Temp Range | Ambient to 220 °C (1 °C increments) |
| Cold Trap Temp Range | −35 °C to ambient (1 °C increments) |
| Temperature Control Accuracy | < ±0.5 °C |
| Adsorption Flow Rate | 0–300 mL/min (adjustable) |
| Desorption/Injection/Backflush Time Range | 0.01–999 min |
| Backflush Flow Rate | 0–160 mL/min (adjustable) |
| Sample Capacity | 1 tube position |
| Desorption Recovery | >90% |
| Dimensions | 400 × 220 × 420 mm |
| Power Consumption | ~300 W |
| Weight | ~20 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP-6900N |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Room Temperature to 350°C (1°C increments) |
| Cold Trap Temperature Range | −35°C to Room Temperature (1°C increments) |
| Valve & Transfer Line Temperature Range | Room Temperature to 220°C (1°C increments) |
| Temperature Control Accuracy | < ±0.5°C |
| Adsorption Flow Rate | 0–300 mL/min (adjustable) |
| Desorption/Injection/Backflush Time Range | 0.01–999 min |
| Backflush Flow Rate | 0–160 mL/min (adjustable) |
| Dimensions | 400 × 220 × 420 mm |
| Power Consumption | ~300 W |
| Weight | ~20 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HP-6900N |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | −35 °C to Ambient (1 °C increments) |
| Temperature Control Accuracy | < ±0.5 °C |
| Sample Loop Capacity | Not Applicable (Direct Air Sampling System) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber with Cryogenic Trapping |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | < ±0.5 °C |
| Sample Loop Capacity | N/A (Continuous Air Sampling) |
| Dimensions | 400 × 220 × 420 mm |
| Power Consumption | ~300 W |
| Weight | ~20 kg |
| Brand | Beifen Sanpu |
|---|---|
| Model | HPGC-9860 |
| Type | Laboratory Gas Chromatograph |
| Origin | Hebei, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Compliance | GB/T 17623–1993, GB/T 7252–2001, DL/T 722–2000 |
| Detection Limits (per 1 mL oil sample) | H₂: 2 µL/L, CO: 2 µL/L, CO₂: 20 µL/L, CH₄: 0.2 µL/L, C₂H₂: 0.1 µL/L, C₂H₄: 0.1 µL/L, C₂H₆: 0.1 µL/L |
| Repeatability | Qualitative ≤1%, Quantitative ≤3% |
| Configuration | Dual-column, triple-detector (TCD/FID) flow path |
| Control | Fully networked workstation with remote bidirectional control (temperature, ignition, bridge current, carrier gas flow) |
| Optional | Electronic Flow Controller (EFC), Electronic Pressure Controller (EPC) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | HPTDS-III |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Quantitative Loop Temperature Control Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL or 3 mL) |
| Sample Vial Capacity | 12 positions |
| Vial Size Compatibility | 10 mL and 20 mL |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| RSD for Injection Precision | ≤1.5% (n = 6, 40 ppm ethanol in water) |
| Purge/Backflush Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions (L × W × H) | 200 × 360 × 420 mm |
| Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSA-20A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Loop Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Carrier Gas Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Pressure Regulation | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Pressurization Time | 0–999 s |
| Bake-out/Flush Flow | 0–100 mL/min (adjustable) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | HTDS-III |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | JAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–1800 s |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–1800 s |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB 2.0 |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 ready (with optional audit trail software module) |
| Brand | Beifen Sanpu |
|---|---|
| Model | KAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C on request), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| Rinse Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication with PC |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Model | KS-1 |
| Standard Compliance | GB/T 3536, ASTM D92 |
| Flash Point Range | Ambient to 400 °C |
| Repeatability | ±2 °C (≤150 °C), ±4 °C (>150 °C) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 400 W |
| Temperature Control | Solid-State Voltage Regulator (Continuous Ramp) |
| Dimensions (W×D×H) | 285 × 185 × 350 mm |
| Net Weight | 7 kg |
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KS100 |
| Compliance | GB/T 267–1988, GB/T 3536–2008, GB/T 1671–2008, ASTM D92 |
| Measurement Range | Ambient to 400 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤3 °C |
| Temperature Resolution | 0.1 °C |
| Sensor | Imported Class A PT100 Platinum Resistance Thermometer |
| Ignition Detection | Ionization Ring Sensor |
| Power Supply | AC 220 V ±20%, 50 Hz ±10% |
| Rated Power | 400 W |
| Dimensions | 440 × 280 × 290 mm |
| Weight | 18 kg |
| Operating Environment | 0–40 °C, ≤85% RH |
| Control Interface | Capacitive Touchscreen with Screen Protection |
| Data Storage | 255 Test Records with Timestamps |
| Heating Control | Adaptive PID Algorithm per Standard Protocols |
| Atmospheric Compensation | Integrated Barometric Sensor with Auto-Calibration |
| Ignition Options | Selectable Electronic Spark or Gas Flame Ignition |
| Multi-Furnace Capability | Single Host Controls Multiple Independent Test Furnaces |
| Automation Level | Full Cycle Automation (Heating, Lid Opening, Ignition, Flash Detection, Alarm, Cooling, Reporting) |
| Built-in Thermal Printer | High-Speed, Dot-Matrix, Offline Printing Support |
| Self-Diagnostic System | Real-Time Sensor Health Monitoring and Over-Temperature Safeguard |
| Brand | Beifen Sanpu |
|---|---|
| Model | LC-3000 |
| Pump Type | Dual-plunger reciprocating high-pressure solvent delivery system |
| Detector | UV-Vis (190–700 nm) with deuterium/tungsten lamp source |
| Flow Rate Range (Analytical) | 0.001–9.999 mL/min |
| Flow Precision | RSD ≤ 0.5% at 1 mL/min |
| Flow Repeatability | RSD ≤ 0.1% at 1 mL/min |
| Max Pressure (Analytical, stainless steel) | 42 MPa |
| Max Pressure (Analytical, PEEK) | 30 MPa |
| Baseline Noise | ≤1.5 × 10⁻⁵ AU/h (254 nm, MeOH/H₂O 80/20, 1 mL/min) |
| Baseline Drift | ≤4 × 10⁻⁴ AU/h (254 nm, MeOH/H₂O 80/20, 1 mL/min) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Data Interface | RS-232 serial control + direct analog/digital signal output to PC |
| Software | GLP-compliant intelligent remote-control chromatography workstation with audit trail capability |
| System Architecture | Modular, field-upgradable from isocratic to binary or quaternary gradient configuration |
| Biocompatibility Option | PEEK pump heads and fluidic path components available |
| Dimensions (Pump/Detector) | 398 × 149 × 267 mm |
| Weight | 10 kg per module |
| Power | 220 V ±10%, 50 Hz, 40 W |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-10 |
| Temperature Control Range | Ambient to 450 °C |
| Gas Flow Rate | 0–200 mL/min |
| Tube Capacity | 10 tubes |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Temperature Accuracy | ±1 °C |
| Maximum Aging Duration | >999 h |
| Simulated Sampling Time | 0–99 min |
| Flow Adjustment Range | 0–1000 mL/min |
| Tube Dimensions (Standard) | Ø6 mm × ≥110 mm |
| Dimensions (H×W×D) | 225 × 265 × 345 mm |
| Net Weight | ~10.5 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-10A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 10 tubes |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LH-24A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–500 mL/min (expandable to 0–1000 mL/min per specification) |
| Tube Capacity | 24 adsorption tubes |
| Control Accuracy | ±1 °C |
| Max Aging Duration | >999 h |
| Dimensions (H×W×D) | 350 mm × 230 mm × 330 mm |
| Net Weight | ~12 kg |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-24B |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 24 tubes |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Temperature Accuracy | ±1 °C |
| Maximum Aging Duration | >999 h |
| Simulated Sampling Time | 0–99 min |
| Tube Dimensions (Standard) | Ø6 mm × ≥110 mm or 1/4″ OD × ≥3.5″ |
| Dimensions (H×W×D) | 350 × 230 × 330 mm |
| Net Weight | ~12 kg |