Chromatography Instruments
Filter
Showing 931–960 of 1498 results
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Flexar |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 1.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Loop Capacity | 1.5 mL (100-position tray) |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FLEXAR™ |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Pump Configuration | Dual Binary Solvent Delivery |
| Maximum Pressure Rating | >18,000 psi |
| Integrated Piston Wash Function | Yes |
| Real-Time Pressure Monitoring | Supported via Chromera CDS |
| Gradient Delay Volume | Minimized for UHPLC compatibility |
| Column Oven Temperature Range | Ambient to 90 °C (optional extension to 110 °C) |
| UV-Vis Detector Wavelength Range | 190–900 nm (with optional diode array) |
| Data Acquisition Rate | Up to 100 Hz |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready architecture |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | GC 2400 |
| Instrument Type | Laboratory Gas Chromatograph-Mass Spectrometer |
| Application Scope | General-Purpose GC-MS Analysis |
| Key Feature | Integrated Split Touchscreen Control Interface |
| Detection Technology | Quadrupole Mass Spectrometry (MS 2400 SQ) with Clarifi™ Detector |
| Sample Introduction | Smart Liquid Autosampler with Pressure-Balanced Injection |
| Safety System | Integrated Hydrogen Sensor |
| Source Technology | SMARTsource™ Replaceable Ion Source |
| Software Platform | Simplicity™ GC/MS Workstation |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC 300 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) / High-Performance Liquid Chromatograph (HPLC) |
| Pressure Rating Options | 10,000 psi (HPLC mode) or 18,000 psi (UHPLC mode) |
| Detector Options | PDA, Multi-Channel UV/Vis, Single-Channel UV/Vis, Fluorescence, Refractive Index |
| Software Platform | Simplicity™ Chrom CDS |
| Gradient Accuracy | <0.2% RSD |
| System Dispersion Volume | <12 µL (typical, full system configuration) |
| Autosampler Features | Integrated color touchscreen display, programmable sample cooling (4–40 °C), low carryover (<0.005%) |
| Column Oven Temperature Range | 5–90 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SNFR |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Torion T-9 |
| Instrument Type | Portable GC-MS |
| Application Field | Environmental Monitoring |
| Weight | 14.5 kg |
| GC Technology | Low Thermal Mass (LTM) Capillary Column |
| MS Technology | Miniature Toroidal Ion Trap |
| Mass Range | 45–500 amu |
| Resolution | Unit resolution or better |
| Operating Temperature | 175 °C (ion trap) |
| Power Source | Rechargeable Li-ion battery (2.5 h runtime) |
| Carrier Gas | Integrated high-pressure helium cylinder |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Ramp Rate | Up to 2.5 °C/s |
| Column Heating/Cooling | Rapid thermal cycling enabled by resistive LTM heating |
| Vacuum Requirement | ~10⁻³ Torr |
| Display | Color touchscreen interface |
| Software | CHROMION with NIST library integration, deconvolution, spectral averaging, and quantitative methods (internal/external standard) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | G5 |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +7°C to 400°C |
| Max. Number of Simultaneous Inlet/Detector Mounts | 3 |
| Temperature Program Steps | 10-step |
| Inlet/Detector Configuration Flexibility | Modular |
| Carrier Gas Control | Digital Precision Flow/Pressure Regulation |
| Compliance | Designed to meet core requirements of ISO/IEC 17025, ASTM D3606, USP <621>, and FDA 21 CFR Part 11 for data integrity |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | G600 |
| Temperature Control Range | 7 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min (adjustable in 0.1 °C increments) |
| Maximum Injector Temperature | 450 °C |
| Injector Configuration | Up to three independently configurable inlets |
| Column Oven Cooling | Forced-air active cooling |
| Detector Options | FID, TCD, ECD, PID (field-selectable) |
| Compliance | GLP/GMP-ready software audit trail, 21 CFR Part 11–compatible data handling |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Maximum Column Oven Ramp Rate | 0–120 °C/min |
| Simultaneous Inlet Configuration | Up to 3 Independent Inlets |
| Compatible Detectors | TCD, FID, ECD, FPD, NPD, PDD, MSD |
| Flow Control System | Precision Smart Flow Control (SFC) |
| Inlet Temperature Capability | Not Specified |
| Pressure & Flow Ranges | Not Specified |
| Cooling Rate | Not Specified |
| Cloud-Enabled Features | Method Optimization Engine, Remote Fault Diagnostics, Centralized Method Library |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | L820 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical HPLC |
| Price Range | USD 56,000 – 84,000 (FOB Beijing) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11, Chinese Pharmacopoeia 2020 Edition, Chinese Veterinary Pharmacopoeia 2020 Edition |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Onyx |
| Instrument Type | Post-Column Derivatization System |
| Derivatization Chemistry | Ninhydrin-based (Trione® reagent) |
| Detection Mode | Visible Absorbance (570 nm & 440 nm) |
| Compatible HPLC Platforms | Standard UV/Vis-equipped HPLC systems |
| Amino Acid Coverage | Up to 50 free amino acids |
| Typical Detection Sensitivity | ≤10 pmol (ninhydrin), ≤2 pmol (OPA alternative) |
| Resolution | ≥1.5 for Leu/Ile, ≥1.2 for all other standard amino acids |
| Equilibration Time | 9 min |
| Run Time | 30 min (hydrolysates), 70 min (free amino acids) |
| Reagent Stability | Trione® ninhydrin reagent exhibits enhanced thermal and oxidative stability vs. conventional ninhydrin solutions |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | France |
| Model Series | PICLab 100 / 150 / 200 / 600 / 1000 |
| Instrument Type | Preparative SFC System |
| Detector Options | DAD, UV-Vis, Mass Spectrometer (MS) |
| Maximum Operating Pressure | 350 bar |
| CO₂ Flow Rate Range | 10–1000 mL/min |
| Application Modes | Analytical, Semi-Preparative (up to 100 g), and Preparative (gram-to-kilogram scale) |
| CO₂ Recycling Capability | Standard on PICLab 150 and above |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR |
| Instrument Type | High-Temperature GPC System |
| Pump Flow Range | 1 mL/min |
| Maximum System Pressure | 1000 psi |
| Column Oven Temperature Range | Up to 250 °C |
| Detector Configuration | IR4 or IR5 MCT Infrared Detector (C–H selective) |
| Optional Detectors | Four-Capillary Viscometer, Multi-Angle Light Scattering (MALS), Refractive Index (RI) |
| Automation | 42-position Autosampler with Integrated Sample Dissolution, Online Filtration & Backflush, Nitrogen Deoxygenation, Flow Marker Injection |
| Software | GPC-One (Multi-Detector Synchronization, Real-Time Data Acquisition, Mark–Houwink Analysis, Branching Quantification) |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | CF2000 |
| Maximum Rotational Speed | 6500 rpm |
| Separation Mechanism | Size-based and Density-based Fractionation |
| Application Focus | Nanomaterial Sizing, Branched vs. Linear Polymer Analysis in Aqueous and Organic Solvents |
| Instrument Type | Centrifugal Field Flow Fractionation System |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | EAF2000 |
| Instrument Type | Asymmetric Flow Field-Flow Fractionation (AF4) with Integrated Electric Field-Flow Fractionation (EF4) |
| Operating Solvent Compatibility | Aqueous only |
| Channel Configuration | Dual-field, orthogonal separation channel module |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | GF2000 GS |
| Separation Mode | Gravitational Sedimentation FFF |
| Core Technology | SPLITT (Split Flow Thin Cell Fractionation) |
| Channel Configuration | Horizontal, Membrane-Free, Stationary-Phase-Free |
| Applicable Sample States | Aqueous or Low-Viscosity Suspensions |
| Typical Particle Size Range | 10 nm – 100 µm (dependent on density contrast and flow conditions) |
| Max. Sample Concentration | ≤ 5% w/v (varies by particle density and dispersibility) |
| Flow Rate Range | 0.1–5.0 mL/min (per inlet) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | SC2000 |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–9.995 mL/min |
| Pump Pressure Limit | 40 MPa |
| RI Detector Drift | 1 × 10⁻⁷ RIU/h |
| RI Detector Cell Volume | 8 µL |
| UV Detector Wavelength Range | 190–800 nm |
| UV Detector Noise | ±0.3 × 10⁻⁵ AU |
| Column Oven Temperature Range | +5 °C to +90 °C |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | TF 2000 |
| Field Type | Thermal |
| Instrument Category | Field Flow Fractionation (FFF) |
| Regulatory Class | Imported Analytical Instrument for Macromolecular & Nanoparticle Characterization |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PRE-2000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision | ≤0.2% RSD |
| Flow Reproducibility | ≤0.2% RSD |
| Maximum Pressure | 5000 psi |
| Wavelength Range | 190–800 nm (±1 nm) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤0.15 × 10⁻⁵ AU |
| Data Acquisition Rate | 100 Hz |
| Pump Configuration | Dual Isocratic or Gradient Capable |
| Gradient Composition Range | 0–100% B |
| Auto-Cleaning Pump Head | Integrated |
| Maintenance Interval | ≥6 months under continuous operation |
| Brand | Prin-Cen |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | ELSpe-2 |
| Pricing | Upon Request |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Autosampler Capacity | 120 positions × 2 mL vials |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | PUREN |
|---|---|
| Model | PAGM |
| Instrument Type | Online Ion Chromatograph with Integrated Aerosol Sampling & Pre-treatment System |
| Origin | Shandong, China |
| Manufacturer | PUREN Instrument Co., Ltd. |
| Pump Pressure Rating | 36 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 1.0 mL/min |
| Max Operating Pressure | 15 MPa |
| Operating Temperature Range | 14–35 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 1.0–5.0 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-10 Dual-System |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PIC-10 Dual-System Fully Automated |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Instrument |
| Model | PIC-10A Dual-System |
| Instrument Type | Benchtop Laboratory Ion Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Inorganic Ions |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop IC System |
| Configuration | Dual-Channel Simultaneous Anion/Cation Analysis |
| Pump Material Options | Stainless Steel (Max. 42.0 MPa) / PEEK (Max. 35 MPa) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max. Operating Pressure | 10 MPa (1500 psi) |
| Column & Detector Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detection Modes | Conductivity (dual-channel), Amperometric (optional), UV-Vis (optional) |
| Integrated Components | Built-in degasser (pre- and post-suppressor), CO₂ removal module, electrochemical suppressor (continuous regeneration), column switching valve, auto-sampler interface, embedded high-resolution LCD control panel with real-time chromatogram display |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PIC-10A (Dual-System Autosampler Configuration) |
| Detection Modes | Conductivity Detection (Standard), Optional Pulsed Amperometric Detection (PAD), DC Amperometric Detection, Integral Amperometric Detection, Differential Pulse Voltammetry |
| Anion Separation Range | F⁻, Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻, Br⁻, PO₄³⁻, ClO₂⁻, ClO₃⁻, BrO₃⁻ |
| Cation Separation Range | Li⁺, Na⁺, NH₄⁺, K⁺, Ca²⁺, Mg²⁺, Sr²⁺, Ba²⁺ |
| Detector | Dual Conductivity Detector (Simultaneous Anion/Cation Monitoring) |
| Pump System | Dual Microprocessor-Controlled Double-Plunger Reciprocating Pumps |
| Flow Pulsation | Minimized via Intelligent Flow Algorithm |
| Gradient Capability | Binary to Quaternary Gradient Elution |
| Fluidic Path Materials | PEEK (Imported, Acid/Base/100% Organic Solvent Compatible) |
| Suppressor | Auto-Regenerating Membrane Suppressor (pH 0–14, On-Line Regeneration, Low Background Conductivity, Maintenance-Free Operation) |
| Thermostat | Integrated Internal Column & Detector Thermostat (Patent No. 200820019630.3) |
| Data Acquisition | High-Precision Digital-to-Analog Conversion |
| Interface | USB (Workstation Communication), RS-232/485 (Pump & Peripheral Control) |
| Autosampler | Electric-Valve Full-Loop Injection, Trace-Sample Compatible, Residual-Free, High Reproducibility (RSD < 1.2%) |
| Software Functions | Real-Time Parameter Remote Control, Baseline Subtraction, Automatic Peak Integration, Negative Peak Recognition, Fault Diagnostics & Instrument State Monitoring, Report Generation (PDF/CSV/XLS), Audit-Trail Ready Data Logging |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | Universal (Anions & Cations) |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PIC-20 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| System Operating Pressure Limit | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-20 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–36.0 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detector Configuration | Dual Conductivity Detectors + Optional Amperometric Detector |
| Column Oven | Integrated Peltier-heated Column/Suppressor Compartment (Patent No. ZL200820019630.3) |
| Data Storage | Local SSD + Cloud Synchronization |
| Connectivity | USB 2.0, Wi-Fi, Mobile App Remote Control (iOS/Android) |
| Compliance | Designed for ISO/IEC 17025 environments |