| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & Direct Producer |
| Instrument Class | Laboratory-Scale Medium-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–150.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Purifier 200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–700 nm (D₂ lamp) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & Direct Producer |
| Instrument Class | Laboratory-Grade Medium-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 5 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU @ 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Gradient Types | Step, Linear, Real-Time Modifiable |
| UV Detector | Dual-Lamp (Deuterium + Tungsten), Dual-Wavelength Simultaneous Detection |
| Autosampler/Collector | 2×60-position rack for 15 mm × 150 mm test tubes |
| Software Platform | Sanochrom™ Chromatography Workstation (Windows 7/8/10 compatible, USB + RS-232 interface) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM & In-House Producer |
| Product Category | Domestic |
| Model | Purifier 50 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZG-100 |
| Price Range | USD 14,000–28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| Gradient Types | Step, Linear, On-the-Fly Adjustable |
| Detection Modes | Dual-Wavelength Simultaneous Monitoring |
| Fraction Collection | Automated, 2×60-tube rack (Φ15×150 mm), Time/Peak/Threshold/Sequential/Cyclic Modes |
| Injection | Manual Prep Valve (10 mL loop standard), Solid or Liquid Sample Loading |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, user access control) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ZG-50 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Purifier-100 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Gradient Types | Step, Linear, Real-Time Modifiable |
| Minimum Gradient Increment | 1% |
| Pressure Pulsation | ≤0.2 MPa |
| UV Detector Light Source | Dual Deuterium & Tungsten Lamps (Imported) |
| Absorbance Range | 0–2 AU |
| Fraction Collector | Automated, 2 × 60 positions (Φ15 mm × 150 mm vials, optional configurations available) |
| Collection Modes | Time-based, Peak-triggered, Threshold-triggered, Sequential, Recirculating |
| Sample Injection Valve | Prep-Grade Manual Injector (10 mL loop standard) |
| Sample Introduction | Solid or Liquid Loading |
| Fluidic Materials Options | 316L Stainless Steel, PEEK, Pure Titanium, Hastelloy |
| Software Compliance | Fully 21 CFR Part 11 & CFDA GxP Compliant |
| System Bus | High-Speed Digital Communication Architecture |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & Direct Producer |
| Product Category | Domestic |
| Model | Purifier300 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC System |
| Flow Rate Range | 0.01–300.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–700 nm (D₂ + W lamp) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU @ 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Purify-150 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Q0502 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–50 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Operating Pressure | 6 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise | ≤1×10⁻⁵ AU |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Q0510 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–50 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Q2005 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–50 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ±1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | S-100 |
| Price Range | USD 14,000–28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | S10C3025 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure Rating | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Model | S26310 |
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Pressure Preparative Liquid Chromatography Column |
| Internal Diameter | 26 mm |
| Length | 310 mm |
| Maximum Operating Pressure | 40 bar (4 MPa) |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Column Material | Borosilicate Glass with Reinforced Stainless Steel Jacket |
| Sample Introduction Design | Flared Inlet Head (No Traditional Frit-Based Packing) |
| Compatible Packing Materials | 30–50 µm C18, Silica, Amino, Cyano, and Other Standard Prep LC Phases |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | S26460 |
| Application Level | Laboratory Grade |
| Instrument Type | Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Column Dimensions | 26 mm ID × 460 mm L |
| Max. Pressure Rating | 40 bar (glass body), compatible with medium-pressure preparative LC systems |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SW100 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Gradient Types | Step, Linear, Online Adjustable |
| UV Detector | Dual-lamp (Deuterium + Tungsten), Simultaneous Dual-Wavelength Detection |
| Fraction Collector | Automated, 2 × 60 positions (Φ15 mm × 150 mm tubes), Time/Peak/Threshold/Sequential/Cyclic Collection Modes |
| System Materials | 316L Stainless Steel, PEEK, Titanium, Hastelloy options |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access control, database-driven project management) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ZB-100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ZB100 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ZD100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Safety & Pesticide Residue Testing |
| Oven Temperature Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Rate | ~6 min from 350 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Temperature Control Range | +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SPGC-9860 |
| Pricing | Upon Request |
| Brand | Santai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | SepaBean Machine |
| Price Range | USD 28,000 – 42,500 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ≤1% |
| Flow Precision (RSD) | ≤2% |
| Maximum Operating Pressure | 200 psi (13.8 bar) |
| Wavelength Range | 200–400 nm / 200–800 nm (DAD) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Baseline Noise | 50 mAU |
| Data Acquisition Frequency | 5 Hz |
| Gradient Configuration | Quaternary Solvent Delivery with High-Pressure Binary Mixing |
| Column Management | RFID-Enabled Auto-Recognition Column Mounting System |
| Fraction Collection | Motorized Rack with Automatic Tube Size Detection (13/15/18/25 mm) and Optional Square Bottles (250/500 mL) |
| Safety Features | Real-Time Solvent Level Monitoring, Leak Detection, Overpressure Protection, Emergency Stop, Power-Fail Recovery |
| Integrated Air Pump Module | Yes |
| Control Interface | Wireless Mobile Device (iOS/Android) via Secure AES-128/AES-256 Encrypted Communication |
| Software Compliance | Audit Trail, User Role-Based Access Control (Admin/Operator/Viewer), Export Permissions Management, GLP-Ready Data Integrity Framework |
| Brand | Santai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | SepaBean Machine U100 – Entry-Level |
| Price Range | USD 7,000–14,000 (FOB) |
| Application Level | Laboratory |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ≤1% |
| Flow Precision | ≤2% |
| Maximum Operating Pressure | 100 psi (6.9 bar) |
| Wavelength Range | 200–400 nm / 200–800 nm (DAD option) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | 50 mAU |
| Data Acquisition Frequency | 5 Hz |
| Gradient Configuration | Binary, Dual-Solvent |
| Detection Modes | Single-Wavelength, Dual-Wavelength, Full-Spectrum Scanning |
| Flow Cell Pathlength | 0.3 mm (standard), 2.4 mm (optional) |
| Collection Modes | Full Fraction, Threshold-Based, Full-Spectrum Triggered, Waste |
| Collection Vessels | Standard: 13/15/18/25 mm test tubes |
| Optional | 250 mL / 500 mL French square bottles or custom containers |
| Safety Features | Solvent level monitoring, leak detection, overpressure protection, emergency stop, power-loss recovery |
| Integrated Air Pump Module | Yes |
| Control Interface | Wireless mobile device (iOS/Android) |
| Software Encryption | AES-128/AES-256 |
| Compliance | CE Marked |
| Brand | Santai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | SepaBean Machine U200 – Entry-Level |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ≤1% |
| Flow Precision | ≤2% |
| Maximum Pressure | 200 psi (13.8 bar) |
| Wavelength Range | 200–400 nm / 200–800 nm (DAD) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | 50 mAU |
| Data Acquisition Frequency | 5 Hz |
| Gradient Configuration | Binary, Dual-Solvent |
| Detection Modes | Single-Wavelength, Dual-Wavelength, Full-Spectrum Scanning |
| Flow Cell Pathlength | 0.3 mm (standard), 2.4 mm (optional) |
| Collection Modes | Full Collection, Threshold-Based, Full-Spectrum Triggered, Waste |
| Solvent Reservoir Monitoring | Yes |
| Leak & Overpressure Protection | Yes |
| Emergency Stop & Power-Fail Recovery | Yes |
| Integrated Air Pump Module | Yes |
| Wireless Control Interface | Yes |
| Data Encryption | AES-128/AES-256 |
| Compliance | CE Marked |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ScalePuri-50 |
| Application Level | Pilot-Scale Laboratory |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Flow Rate | 0–200 mL/min |
| Flow Accuracy | ±2.0% |
| Pressure Rating | Up to 20 MPa |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.5 mAU (at 254 nm) |
| Detection Modes | Quadruple Wavelength Simultaneous Monitoring |
| Column Compatibility | Axial Compression Columns (DAC50, ID 10–50 mm) |
| Fraction Collection | Volume-, Peak-, Time-, or Threshold-Triggered |
| Software Compliance | 21 CFR Part 11 Ready, Audit Trail, Electronic Signatures, User & Role Management |
| Regulatory Alignment | Designed for GLP/GMP environments, supports IQ/OQ/PQ validation |
| Brand | SCIEX |
|---|---|
| Origin | Germany |
| Model | 608010 |
| Package Size | 10 mL per pack |
| Category | Consumable for Capillary Electrophoresis Systems |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | BioPhase 8800 + NFD |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Detector | Native Fluorescence Detector (NFD) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| CE Modes Supported | CE-SDS, cIEF, CZE |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Linear Dynamic Range | >4 decades |
| Correlation Coefficient (R²) | ≥0.995 |
| Sensitivity | Sub-μg/mL for native protein detection |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX BioPhase™ 8800 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Channel Capacity | 8 parallel capillaries |
| Detection Modes | UV-Vis and Laser-Induced Fluorescence (LIF) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| Application Focus | Biopharmaceutical characterization (mAb, bispecifics, ADCs, gene therapy vectors) |
| Sensitivity | ≤1 µg/mL (CE-SDS), linear dynamic range >4 orders of magnitude (R² > 0.995) |