Chromatography Instruments
Filter
Showing 991–1020 of 1564 results
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CS2501 |
| Price Range | USD 14,000–28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.1–100.00 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 5 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Gradient Types | Step, Linear, Real-Time Adjustable |
| Detector Light Source | Dual Lamp (Deuterium + Tungsten, Imported) |
| UV/Vis Detection Modes | Dual-Wavelength Simultaneous Detection, Time-Programmed Wavelength, Stop-Flow Scanning |
| Sample Collection | Automated Fraction Collector with 2×60 positions (Φ15 mm × 150 mm tubes), Volume/Time/Threshold/Slope-Triggered Collection, Delay Volume Compensation, Independent Waste Channel, High-Accuracy Vial Switching |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, user access control, data integrity safeguards) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DAC Series |
| Price | USD 7,000–85,000 (varies by configuration) |
| Application Level | Laboratory to Pilot-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–6,000 mL/min (model-dependent) |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa (100 bar) |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Column ID Options | 50–300 mm |
| Max. Bed Height | 500 mm |
| Column Tube Material | 316L Stainless Steel |
| Wall Roughness (Ra) | ≤0.2 µm |
| Frit Pore Size | 2 µm |
| Frit Material | 316L Stainless Steel |
| Gradient Types | Step, Linear, Real-Time Adjustable |
| Minimum Gradient Increment | 1% |
| UV Detector Light Source | Imported Deuterium Lamp + Tungsten Lamp |
| Absorbance Range | 0–2 AU |
| Collection Modes | Time-Based, Peak-Triggered, Threshold-Triggered, Sequential, Recirculating |
| Recommended Particle Sizes | 5–10 µm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DAC-100 |
| Application Level | Industrial Preparative Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–1000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Column ID | 100 mm |
| Max Bed Height | 500 mm |
| Column Tube Material | 316L Stainless Steel |
| Wall Roughness (Ra) | ≤0.2 µm |
| Frit Pore Size | 2 µm |
| Frit Material | 316L Stainless Steel |
| Recommended Particle Size | 5–10 µm |
| Pump Max Flow | 600 mL/min |
| Recommended Operational Flow | 200–350 mL/min |
| Gradient Types | Step, Linear, Real-Time Modifiable |
| Minimum Gradient Increment | 1% |
| UV Detector Light Sources | Deuterium + Tungsten Lamps (Imported) |
| Absorbance Range | 0–2 AU |
| Collection Modes | Time-Based, Peak-Triggered, Threshold-Based, Sequential, Recirculating |
| System Dimensions (W×D×H) | 750 × 650 × 2360 mm |
| Net Weight | 240 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DAC300 |
| Application Level | Industrial-Scale Preparation |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–3000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DAC80 |
| Application Level | Industrial Preparative Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–1000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Model | ELSD-6000 |
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | HPLC-Compatible Evaporative Light Scattering Detector |
| Flow Rate Range | 0.01–3 mL/min |
| Max Operating Pressure | 1 bar |
| Sample Injection Positions | 1 |
| Injection Volume Range | 1 µL–100 µL (system-dependent) |
| Drift Tube Temperature Range | Ambient to 150 °C (1 °C increment) |
| Nebulizer Temperature Range | Ambient to 50 °C (1 °C increment) |
| Light Source | 650 nm, 30 mW Semiconductor Laser |
| Photodetector | Photomultiplier Tube (PMT) |
| Data Acquisition Rate | 20 Hz |
| Baseline Noise | ≤ 0.03 mV |
| Baseline Drift | ≤ 0.3 mV / 60 min |
| Quantitative Reproducibility (RSD) | ≤ 2% |
| Minimum Detectable Mass | < 1 ng |
| Typical Linear Quantitation Range | 0.1–30 µg |
| Gas Supply | Clean, oil-free air or nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Flow Control | Mass Flow Controller, accuracy ≤ ±1% or ±0.02 L/min |
| Gain Adjustment | Linear, 0.3–30× continuous |
| Analog Output | –1200 to +1200 mV |
| Digital Interfaces | RS-232, USB, LAN (TCP/HTTP), programmable external event I/O |
| Power | 85–264 VAC, 50 Hz |
| Dimensions (W×H×D) | 260 × 190 × 460 mm |
| Weight | 10 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ELSD9000 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Conventional HPLC-Compatible Detector |
| Flow Rate Range | 0.01–3 mL/min |
| Max Operating Pressure | 1 bar |
| Sample Injection Port | Single-channel |
| Injection Volume Range | Not applicable (flow-through detector) |
| Temperature Control Range | Ambient to 150 °C (1 °C step resolution) |
| Light Source | 650 nm, 30 mW laser diode |
| Data Acquisition Rate | 20 Hz (digital output), 100 Hz (internal sampling) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ePilot-100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ePurify-100 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | Yes |
| Model | ePurify100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Flash 100 |
| Price Range | USD $14,000–$28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Gradient Capability | Up to 4-Solvent Linear/Step Gradients |
| Fraction Collection Modes | Time-, Peak-, Threshold-, and Slope-Triggered |
| Software Compliance | FDA 21 CFR Part 11 & CFDA GxP-Compliant Sanochrom™ Control Software |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FS-100 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–10.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FS-50 |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Grad600 |
| Price Range | USD 14,000 – 28,500 |
| Application Tier | Industrial-Scale Preparative |
| Instrument Class | Medium-to-Low Pressure Preparative LC System |
| Flow Rate Range | 0.01–600.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU @ 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HPLC-10C18E |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure Rating | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HPLC-5C18E |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Model | HT-100 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| UV Detector | Dual-lamp (Deuterium + Tungsten), Dual-wavelength simultaneous detection |
| Fraction Collector | Auto-collector with 2×60 tube rack (Φ15 mm × 150 mm) |
| Collection Modes | Time-based, peak-triggered, threshold-triggered, sequential, cyclic |
| Injection Valve | Manual preparative valve (standard 10 mL loop) |
| Sample Introduction | Solid or liquid loading |
| Gradient Types | Step, linear, real-time modifiable |
| Minimum Gradient Increment | 1% |
| Software Compliance | CFDA GxP & FDA 21 CFR Part 11 compliant Sanochrom™ workstation (Windows 7/8/10) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | HT-50 |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Pressure | 42 MPa |
| Flow Accuracy | ±1% |
| Flow Precision | ±0.5% |
| Injection Volume Options | 2 mL (108-position) or 4 mL (70-position) |
| Column Oven Temperature Range | Ambient +5 °C to 80 °C |
| Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC2200 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Profile | Dedicated-Use Analytical Instrument |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Maximum Operating Pressure | 42 MPa |
| Detector Wavelength Range | 190–700 nm (D₂ + W lamp) |
| Baseline Noise | ≤1×10⁻⁵ AU |
| Baseline Drift | ≤1.5×10⁻⁴ AU/hr |
| Flow Accuracy | ≤±1% |
| Flow Precision | ±0.5% |
| Flow RSD | ≤0.1% |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Detection Range | 0–3 AU |
| Flow Cell Volume | 10 µL |
| Time Constant | 16-step adjustable |
| Auto-Zero | Full-scale |
| Brand | Sanotac |
|---|---|
| Model | Pilot Series |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min (gradient) |
| Max. Operating Pressure | 30 MPa |
| Injection Volume | 1–20 mL |
| Column Temperature Control | 0–80 °C |
| UV Detection Wavelength Range | 190–800 nm (dual-wavelength simultaneous detection) |
| Data Acquisition Frequency | 10 Hz |
| Detector Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Flow Accuracy | ±0.5% |
| Pressure Pulsation | ≤0.2 MPa |
| Pump Material Options | 316L Stainless Steel, PEEK, Titanium, Hastelloy |
| Fraction Collector | Auto, 2 × 60 positions (Φ15 mm × 150 mm tubes), multiple collection modes |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access control, database-driven project management) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Pilot |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot-1000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–1000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Pilot-300 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–300.00 mL/min |
| Maximum Pressure | 15 MPa |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Pressure Pulsation | ≤0.5 MPa |
| Wavelength Range (UV-Vis Detector) | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Flow Cell Path Length | Adjustable (1–5 mm) |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC=1 s) |
| Baseline Drift | 1.5×10⁻⁴ AU (254 nm) |
| Linear Range | ≥3 AU |
| Time Constant Options | 0.1/0.2/0.5/1.0/2.0/5.0/10.0 s |
| Detection Modes | Dual-Wavelength Monitoring, Wavelength-Time Programming, Stop-Flow Scanning |
| Gradient & Flow Programming | 10 User-Defined Methods |
| Column ID Compatibility | 10–30 mm I.D. |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot-50 |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Pilot-600 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–600.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Pilot100 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Pilot200 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Pilot50 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Repeatability | ±0.2 nm |
| Detection Modes | Dual-Wavelength UV, Time-Programmed Wavelength, Stop-Flow Scanning |
| Gradient Programming | 10 User-Defined Methods |
| Column ID Compatibility | 10–30 mm |
| Detector Cell Pathlength | Adjustable (1–5 mm) |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC=1 s) |
| Baseline Drift | 1.5×10⁻⁴ AU (254 nm, 1 h) |
| Time Constant Options | 0.1/0.2/0.5/1.0/2.0/5.0/10.0 s |
| Digital Zero Adjustment | Full-Scale Auto-Zero |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Purifier 100 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |