Chromatography Instruments
Filter
Showing 961–990 of 1569 results
| Brand | PUREN |
|---|---|
| Model | PIC-10 Dual-System |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PIC-10 Dual-System Fully Automated |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Instrument |
| Model | PIC-10A Dual-System |
| Instrument Type | Benchtop Laboratory Ion Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Inorganic Ions |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop IC System |
| Configuration | Dual-Channel Simultaneous Anion/Cation Analysis |
| Pump Material Options | Stainless Steel (Max. 42.0 MPa) / PEEK (Max. 35 MPa) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max. Operating Pressure | 10 MPa (1500 psi) |
| Column & Detector Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detection Modes | Conductivity (dual-channel), Amperometric (optional), UV-Vis (optional) |
| Integrated Components | Built-in degasser (pre- and post-suppressor), CO₂ removal module, electrochemical suppressor (continuous regeneration), column switching valve, auto-sampler interface, embedded high-resolution LCD control panel with real-time chromatogram display |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PIC-10A (Dual-System Autosampler Configuration) |
| Detection Modes | Conductivity Detection (Standard), Optional Pulsed Amperometric Detection (PAD), DC Amperometric Detection, Integral Amperometric Detection, Differential Pulse Voltammetry |
| Anion Separation Range | F⁻, Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻, Br⁻, PO₄³⁻, ClO₂⁻, ClO₃⁻, BrO₃⁻ |
| Cation Separation Range | Li⁺, Na⁺, NH₄⁺, K⁺, Ca²⁺, Mg²⁺, Sr²⁺, Ba²⁺ |
| Detector | Dual Conductivity Detector (Simultaneous Anion/Cation Monitoring) |
| Pump System | Dual Microprocessor-Controlled Double-Plunger Reciprocating Pumps |
| Flow Pulsation | Minimized via Intelligent Flow Algorithm |
| Gradient Capability | Binary to Quaternary Gradient Elution |
| Fluidic Path Materials | PEEK (Imported, Acid/Base/100% Organic Solvent Compatible) |
| Suppressor | Auto-Regenerating Membrane Suppressor (pH 0–14, On-Line Regeneration, Low Background Conductivity, Maintenance-Free Operation) |
| Thermostat | Integrated Internal Column & Detector Thermostat (Patent No. 200820019630.3) |
| Data Acquisition | High-Precision Digital-to-Analog Conversion |
| Interface | USB (Workstation Communication), RS-232/485 (Pump & Peripheral Control) |
| Autosampler | Electric-Valve Full-Loop Injection, Trace-Sample Compatible, Residual-Free, High Reproducibility (RSD < 1.2%) |
| Software Functions | Real-Time Parameter Remote Control, Baseline Subtraction, Automatic Peak Integration, Negative Peak Recognition, Fault Diagnostics & Instrument State Monitoring, Report Generation (PDF/CSV/XLS), Audit-Trail Ready Data Logging |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | Universal (Anions & Cations) |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PIC-20 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| System Operating Pressure Limit | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-20 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–36.0 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detector Configuration | Dual Conductivity Detectors + Optional Amperometric Detector |
| Column Oven | Integrated Peltier-heated Column/Suppressor Compartment (Patent No. ZL200820019630.3) |
| Data Storage | Local SSD + Cloud Synchronization |
| Connectivity | USB 2.0, Wi-Fi, Mobile App Remote Control (iOS/Android) |
| Compliance | Designed for ISO/IEC 17025 environments |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PIC-30 |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 36 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.04 °C |
| Eluent Concentration Range | 0–20 mM |
| Detector Options | Dual-Channel Conductivity Detector / Single-Channel Voltammetric Detector / Dual-Channel UV-Vis Detector |
| Fluidic Path | All-PEEK Non-Metallic Flow Path |
| Integrated Components | Embedded Chromatography Workstation, Auto-Sampler Interface, Onboard Dilution Module, Eluent Generator Compatibility (Optional), Internal Degasser, CO₂ Suppressor, Column Oven with Integrated Conductivity Cell & Suppressor |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Ion Chromatograph |
| Model | PIC-60 |
| Pump Pressure Rating | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 0–65 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 0–80 mmol/L |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PIC-80 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel) / 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PIC-80B |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Online Analyzer |
| Application | General-Purpose Environmental & Industrial Process Monitoring |
| Pump Pressure Rating | 0–42.0 MPa (Stainless Steel) / 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriMaster-3500C1 |
| Application Level | Laboratory-grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Pump Pressure Rating | 300 bar |
| Flow Rate Range | 0–50 mL/min per pump |
| Flow Stability | ≤2% RSD |
| UV-Vis Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Detector Light Source | Dual-lamp system (Deuterium + Tungsten) |
| Fraction Collection | 6-port switching valve (standard) |
| Auto-sampler Quantitative Loop | 3 mL |
| Gradient Capability | Binary high-pressure mixing |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1100 |
| Temperature Control Range | Ambient +6°C to 399°C |
| Oven Ramp Rate | 0–30°C/min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 200°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Accuracy | ±0.1°C |
| Column Oven Temperature Gradient | ±1.5% |
| TCD Sensitivity | ≥4000 mV·mL/mg (n-hexadecane) |
| TCD Noise | ≤0.04 mV |
| TCD Baseline Drift | ≤0.2 mV/30 min |
| FID Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤0.02 mV |
| FID Baseline Drift | ≤0.2 mV/30 min |
| Dimensions (L×W×H) | 562×550×492.5 mm |
| Weight | 44 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QT-330 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Accuracy at 50 °C | ±0.1 °C |
| Repeatability | ±0.1 °C |
| Heating Chamber Dimensions | 350 mm × 45 mm × 40 mm |
| Display | Dual-line LED with Touch-sensitive Controls |
| Safety Features | Over-temperature Alarm & Auto Cut-off |
| Mounting | Magnetic-latch Lid & Dual Orientation (Vertical/Horizontal) |
| Viewing Window | Integrated Tempered Glass Panel |
| Column Capacity | 1–2 Standard HPLC Columns |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | TS-1 |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Capillary Electrophoresis (CE) Accessory |
| Sample Analysis | Organic Analysis |
| Window Width | 2 mm |
| Processing Time | ≤5 s |
| Compatible Capillary OD | ≤1 mm |
| Coating Removal | Polyimide only |
| Optical Integrity Preserved | Yes |
| Mechanical Integrity Preserved | Yes |
| Brand | Restek |
|---|---|
| Model | 23443 |
| Origin | USA |
| Type | Portable Thermal Conductivity-Based Leak Detector |
| Detectable Gases | He, N₂, Ar, CO₂, H₂ |
| Power Source | Rechargeable Ni-MH Battery (6 h typical runtime) |
| Operating Temperature | 0–48 °C |
| Relative Humidity | 0–97 % RH |
| Certifications | CE, RoHS, WEEE |
| Compliance | Compliant with EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS), and Japan’s JIS C 0950 (RoHS-equivalent) |
| Enclosure Rating | IP54 (dust-protected, water-splashing resistant) |
| Probe Interface | Standard 1/8" Swagelok-compatible stainless steel insertion probe |
| Auto-Shutdown | Enabled after 5 min inactivity |
| Charging Adapter | Universal AC input (100–240 VAC, 50/60 Hz) |
| Brand | Restek |
|---|---|
| Origin | USA |
| Product Lines | Allure® C18, Allure® Basix, Allure® PFP Propyl, Allure® Biphenyl, Ultra C18, Ultra Aqueous C18, Ultra IBD, Kromasil® C18, Viva Wide Pore C18, Pinnacle™ II C18, Pinnacle™ DB C18 |
| Column Dimensions | 50 mm, 150 mm, 250 mm (length) |
| Particle Sizes | 3 µm & 5 µm |
| Catalog Numbers | e.g., 9214352-712, 9414565-712, 9178575-712, etc. |
| Brand | Tlyon (Distributor) |
|---|---|
| Origin | Hungary |
| Manufacturer | RotaChrom GmbH |
| Instrument Type | Benchtop Centrifugal Partition Chromatograph |
| Software Components | CPC Simulator, CPC Visualizer |
| Flow Rate Range | 0.1–25 mL/min |
| Sample Load Capacity | 10 mg–5 g per cycle |
| Detection | UV-Vis (200–600 nm), optional ELSD/MS interface |
| Fraction Collection | Automated, timed or peak-triggered |
| Compliance | GLP-ready architecture, audit trail-capable software logging, ISO/IEC 17025-aligned operation |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROXY |
| Pricing | Available Upon Request |
| Potentiostat | ROXY Potentiostats DCC |
| Autosampler | AS 110 (Cool, Micro, 10-Position Vial) |
| LC Pump | LC 110 |
| Reactor Cell | Integrated with Multi-Electrode Detection (MD) and Gas Collection (GC) Electrodes |
| Organizer | OR 110 |
| Software | Clarity Chromatography Data System |
| Brand | Sanbei Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | TBF-8 |
| Pricing | Upon Request |
| Dimensions | 280 mm × 40 mm |
| Inlet/Outlet Ports | M8×1 thread, Φ3.2 mm, 1/8" NPT |
| Maximum Flow Rate | 5000 mL/min |
| Operating Temperature | Ambient (20–25°C) |
| CO₂ Residual Concentration | ≤0.1 ppm |
| H₂O Residual Concentration | ≤0.1 ppm |
| Adsorption Mechanism | Chromatographic adsorption using proprietary metal oxide-based desiccant and CO₂-selective sorbent |
| Compliance | Designed for GC carrier gas and sample stream purification per ASTM D6299, ISO 8573-1 Class 1 air quality requirements, and GLP-compliant laboratory environments |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Apurifier 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Apurifier 150 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–150.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | aPurifier 50 |
| Price Range | USD $14,000–$28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium- to Low-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Biolot 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BioLot 50 |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm (TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Biolot200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CS100 |
| Price Range | USD $14,000 – $28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–10.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |