Chromatography Instruments
Filter
Showing 901–930 of 1569 results
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 Series |
| Instrument Type | Online Gas Chromatograph |
| Detector Configurability | Up to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID) |
| Injection Options | Packed column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector |
| Oven Temperature Range | +4 °C above ambient to 450 °C (1 °C increment) |
| Oven Temperature Stability | ±0.1 °C at 200 °C |
| Oven Programmable Stages | 16 temperature ramps |
| Cooling Rate | 260 °C to 50 °C in ~6 min |
| Temperature Zones | 8 independently controlled zones |
| Carrier Gas Control | Electronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm |
| Display | 5.7-inch color TFT touchscreen |
| Data Interface | Ethernet (IEEE 802.3), PC-controlled operation or standalone mode |
| Remote Capability | Network-enabled remote monitoring, unattended operation, distributed acquisition, centralized control |
| Multidimensional GC Support | Center-cutting and valve-switching configurations enabled |
| Software | Method-driven acquisition with full parameter storage and recall |
| Compliance | Designed for GLP/GMP environments |
| Brand | MNK |
|---|---|
| Model | GC8800-II |
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Control Interface | IEEE 802.3 Ethernet |
| EPC Module | Integrated Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) |
| Autosampler Compatibility | Dual-tower 24-position liquid autosampler |
| Optional Gas Autosampling | MNK Cylinder & Gas-Phase Autosampler |
| Ancillary Module Support | MNK Flash Vaporizer for LPG, Butadiene, and 1-Butene analysis |
| Data System | Multi-instrument data aggregation |
| Regulatory Alignment | Designed to support GLP-compliant workflows and 21 CFR Part 11–ready audit trail configuration (when paired with validated software) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8810 |
| Instrument Type | Online Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Detector Configuration | Up to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD) |
| Communication Interface | Ethernet-enabled Industrial Bus Architecture |
| Compliance Context | Designed for GLP/GMP-aligned environments with audit-ready data handling capabilities |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Detector Configuration | Dual-detector, multi-column parallel architecture |
| Temperature Control | 8 independent zones, 20-step programmable ramping |
| Advanced Functionality | Built-in back-flush module enabling heart-cutting and column switching |
| Data System | Dedicated GC workstation with automated flammability triangle (CH₄–O₂–N₂) explosion hazard assessment |
| Detection Limits (v/v) | PDHID — H₂ (0.06 µL/L), CH₄ (0.08 µL/L), CO (0.08 µL/L), C₂H₆ (0.01 µL/L), CO₂ (0.09 µL/L), C₂H₄ (0.01 µL/L), C₂H₂ (0.01 µL/L), C₃H₈ (0.01 µL/L), H₂S (0.01 µL/L), C₃H₆ (0.01 µL/L), SO₂ (0.23 µL/L) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Dual-Detector Configuration | PDHID + TCD |
| Independent Temperature Zones | 8 |
| Oven Programmed Ramps | 20-step |
| Back-Flush & Heart-Cut Capability | Integrated |
| Detection Limits (v/v) | PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L |
| TCD — O₂ | 49 µL/L, N₂: 70 µL/L |
| PDHID Specifications | Pulsed Discharge Helium Ionization Detector |
| TCD Specifications | Baseline Noise ≤ 20 µV |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MS200S |
| Pricing | Available Upon Request |
| Liquid Sample Inlet Pressure Range | 0.69–2.75 MPa |
| Gas Sample Inlet Pressure Range | 0.69–2.07 MPa |
| Temperature Control Range (Heating & Trace Heating) | Ambient +5°C to 230°C |
| Temperature Stability | ±0.1°C |
| Carrier Gas Flow Rate | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Operating Ambient Temperature | −18°C to +65°C |
| Surface Passivation | SilcoTek® SilcoNert®-treated Stainless Steel Tubing |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | PGC-8800 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Detectors | PDHID, TCD, FID |
| Detection Limits (ppb) | H₂ (5), He (5), O₂ (10), N₂ (10), Ar (10), Ne (10), CO (25), CO₂ (5), CH₄ (5), CF₄ (10), C₂F₆ (20), SO₂ (20), F₂ (20), C₃F₈ (20) |
| Temperature Control Accuracy | ±0.01°C |
| Baseline Noise | ≤0.1 mV |
| Analog Outputs | 5–12 channels of 4–20 mA |
| Communication Interfaces | 1× Ethernet, 1× RS-232 (expandable) |
| Display | 10.1″ high-resolution capacitive touchscreen |
| Enclosure | Standard 5U rack-mount chassis (482 × 432 × 222 mm) |
| Brand | MNK |
|---|---|
| Model | PGC-8800 |
| Type | Online Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Detection Limits (PDHID) | H₂ (5 ppb), He (5 ppb), O₂ (10 ppb), N₂ (10 ppb), Ar (10 ppb), Ne (500 ppb), CO (25 ppb), CO₂ (5 ppb), CH₄ (5 ppb), CF₄ (10 ppb), C₂F₆ (20 ppb), SO₂F₂ (20 ppb), C₃F₈ (20 ppb) |
| Complementary Detectors | TCD, FID |
| Sample Phase | Gaseous |
| Operating Mode | Continuous Unattended Online Monitoring |
| Origin | Beijing, China |
| Brand | NANOSPACE |
|---|---|
| Origin | Japan |
| Model | F3012 |
| Max. Operating Pressure | 35 MPa |
| Dead Volume | 1.0 µL |
| Wetted Materials | PEEK, Ceramics |
| Control Modes | Manual, Time-Programmable (0.00–999.99 min), External TTL Trigger (Start Signal), SYSCON & PC Communication |
| Power Supply | AC 100 V ±10%, 50/60 Hz, 15 W |
| Dimensions | 120(W) × 230(H) × 491(D) mm |
| Weight | 10 kg |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NBGC-60 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Brand | North Branch Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-8000 |
| Pricing | Available Upon Request |
| Brand | North分Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | AHS-610 Headspace Autosampler + Thermo TRACE 1300 GC |
| Temperature Control Range | 400 °C |
| Heating Rate | 40 °C/min |
| Cooling Rate | from 450 °C to 50 °C in ~5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–16 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NP7001 |
| Price Range | USD 14,000–28,000 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) Pump |
| Flow Mode | Dual-Piston Serial Configuration |
| Flow Range | 0.001–9.999 mL/min |
| Flow Increment | 0.001 mL/min |
| Flow Accuracy | ≤0.5% or ≤10 µL/min |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.5 MPa |
| Maximum Operating Pressure | ≤42 MPa |
| Tubing Connection | 1/16″ Stainless Steel Standard Fittings |
| Display | 4.7″ LCD (320 × 240 pixels), Tab-Based UI |
| User Programs | 10 Predefined Methods |
| Gradient Capability | Linear Flow Gradient Programming |
| Communication Protocol | Open ASCII-Based RS-232/RS-485 Protocol (Third-Party Software Compatible) |
| Maintenance Feature | Optional Automatic Back-Flush Mechanism for Piston Seal and Rear Seal Area |
| Sealing Architecture | Floating Piston Design with Extended Seal Life |
| Flow Damping | Integrated Electronic Pulse Damping Control |
| Calibration | Multi-Point Flow Calibration Curve (Spanning Full Range) |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | OG-2000V |
| Instrument Type | Laboratory Gas Chromatograph for Geochemical Pyrolysis |
| Application Domain | Petroleum & Petrochemical Industry |
| Temperature Control Range | 360 ± 0.5 °C (FID), 600 ± 0.5 °C (Pyrolysis Furnace & Oxidation Furnace) |
| Ramp Rate | < 0.5 °C/min |
| Maximum Injector Temperature | 800 °C |
| Detection Principle | Flame Ionization Detection (FID) |
| Minimum Hydrocarbon Detection | 0.001 mg HC/g rock |
| Baseline Drift | < 0.1 mV/30 min |
| Linear Dynamic Range | 10⁶ |
| Analysis Cycle Time (Full Pyrolysis–Residual Carbon) | 14.5 min |
| Number of Predefined Thermal Programs | 4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined) |
| Temperature Linearity Deviation | < 0.5 °C/min |
| Interface | USB 2.0 (Direct Signal Output to PC) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 006BCC-03-02-FF |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Max Operating Pressure | 1200 psi (80 bar) |
| Column Material | Borosilicate Glass |
| End Frit Material | PCTFE |
| Bed Support Plate | PCTFE & Stainless Steel |
| O-Ring Material | FKM/FPM |
| Tubing Fittings | Glass-Filled Polypropylene (PP) |
| Included Tubing | Two PTFE tubes (2 m and 0.5 m, OD 1/16", one end with 1/4-28 UNF PP fitting) |
| Column Dimensions | 3 mm ID × 25 mm length |
| Frit Options Available | 2–50 µm (PTFE, PE, SS) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 006BCC-15-25-AF |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Max Operating Pressure | 900 psi (60 bar) |
| Column Internal Diameter | 15 mm |
| Column Length | 250 mm |
| End Configuration | One Fixed & One Adjustable End |
| Filter Disc Material | PTFE |
| Filter Pore Size | 5–50 µm (configurable) |
| Column Body Material | Borosilicate Glass |
| Fitting Materials | Acetal (adjustment nut, locking nut), Glass-Filled Polypropylene (tubing nuts & connectors), FKM/FPM O-rings |
| Temperature Range | 4–20 °C |
| pH Range | 1–14 |
| Chemical Compatibility | Aqueous solutions and most common HPLC solvents |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 006EZ-10-25-AF |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Max Operating Pressure | 900 psi (60 bar) |
| Column ID | 10 mm |
| Column Length | 250 mm |
| End Configuration | Axial Compression (One-End Adjustable) |
| Material | Borosilicate Glass Tube, PTFE End Fittings, PE Frits, FKM O-Rings, Acetal Adjustment Nuts, GF-Reinforced PP Hardware |
| Temperature Range | 4–40 °C |
| pH Stability | 1–14 |
| Chemical Compatibility | Aqueous buffers, acetonitrile, methanol, isopropanol, ethanol, THF, DMF, DMSO |
| Compliance | Designed for GLP-compliant workflows and integration with ISO/IEC 17025-accredited purification platforms |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 006EZ-06-15-AF |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative Liquid Chromatography |
| Max Operating Pressure | 900 psi (60 bar) |
| Column Material | Borosilicate Glass Tube with PTFE End Fittings, PE Frits, FKM O-Rings, Acetal Compression Nuts, GF-Reinforced PP Connectors |
| Temperature Range | 4–40 °C |
| pH Stability | 1–14 |
| Solvent Compatibility | Aqueous buffers and common HPLC solvents |
| Included Accessories | 2 m × 1/16″ ID PTFE tubing with 1/4-28 UNF PP fitting + 0.5 m × 1/16″ ID PTFE tubing with 1/4-28 UNF PP fitting |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 006EZS-10-33-AF |
| Price Range | USD 13,500–27,000 (FOB) |
| Application Level | Laboratory-Scale Preparative Purification |
| Instrument Class | Medium-Low Pressure Preparative Liquid Chromatography System |
| Max Operating Pressure | 900 psi (62 bar) |
| Temperature Range | 4–40 °C |
| pH Stability | 1–14 |
| Chemical Compatibility | Fully compatible with aqueous buffers, acetonitrile, methanol, isopropanol, chloroform, DCM, DMF, DMSO, pyridine, toluene, and formamide |
| Column Construction | Borosilicate glass tube, PEEK™ end fittings, Chemraz® O-rings, PTFE frits (10 µm), ETFE compression nuts and ferrules |
| Axial Compression | Single-ended adjustable (AF configuration) |
| Internal Diameter | 10 mm |
| Bed Height | 330 mm |
| Total Volume | ~25.9 mL |
| Flow Rate Range | 0.1–25 mL/min (system-dependent) |
| Flow Precision & Reproducibility | ≤±1% RSD (with calibrated pump) |
| UV Transparency | Full spectral transmission from 190–800 nm (glass + PEEK path) |
| Base Noise (UV-Vis detector compatible) | < ±0.5 mAU (typical, 1 s response) |
| Data Acquisition Rate | Up to 10 Hz (dependent on connected detector) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 006EZ-06-25-AF |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Max Operating Pressure | 900 psi (60 bar) |
| Internal Diameter | 6.6 mm |
| Column Length | 250 mm |
| End-Fitting Configuration | One Fixed + One Adjustable (AF) |
| Tube Material | Borosilicate Glass (Type I) |
| Frit Material | 25 µm Polyethylene (PE) |
| Temperature Range | 4–40 °C |
| pH Compatibility | 1–14 |
| Chemical Resistance | Compatible with aqueous buffers, acetonitrile, methanol, isopropanol, ethanol, THF, DMF, DMSO |
| Sealing System | Dual PTFE O-rings + machined PTFE end-fittings |
| Connection Standard | 10-32 conical thread |
| Axial Adjustment Range | 80 mm |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 006EZS-10-25-AF |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Max Operating Pressure | 900 psi (60 bar) for 6.6 mm ID |
| Column Material | Borosilicate Glass Tube, PTFE Frits, Chemraz® O-Rings, ETFE End Fittings |
| Temperature Range | 4–40 °C |
| pH Stability | 1–14 |
| Chemical Compatibility | Compatible with aqueous buffers, acetonitrile, methanol, THF, DMSO, DMF, chloroform, dichloroethane, pyridine, formamide, toluene |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Omnifit® EZ |
| Pressure Rating | Up to 900 psi |
| Column Dimensions | ID 5–50 mm, Length 50–500 mm, Volume 1 mL–940 mL |
| Construction | Borosilicate Glass Tube with PEEK Threaded End Fittings |
| End Fitting Type | 10-32 Conical |
| Sealing | Dual O-ring + PTFE Endpieces (Fixed or Adjustable) |
| Temperature Rating | ≤80 °C |
| Chemical Compatibility | Broad (incl. aqueous buffers, organic solvents, mild acids/bases) |
| Regulatory Alignment | Designed for GLP-compliant lab workflows |
| Brand | ONE ONE INSTRUMENT |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | IC1700 |
| Application Scope | Laboratory-Based General-Purpose Ion Analysis |
| Maximum System Pressure | 0–36 MPa |
| Flow Rate Range | 0.00–10.00 mL/min |
| Eluent Flow Rate Range | 0.00–10.00 mL/min |
| Operating Temperature Range | +5 °C to +65 °C |
| Temperature Reproducibility | ±1 °C |
| Eluent Concentration Range | 0–100 mmol/L (KOH) |
| Brand | Ontech |
|---|---|
| Model | Ontech610 |
| Type | Online Gas Chromatograph |
| Application | Environmental Emission Monitoring |
| Compliance | HJ 38-2017, HJ 212-2017 |
| Sampling Method | Quantitative Loop Injection |
| Valve Configuration | 12-Position Multiport Valve |
| Column Technology | Dual-Column System with Heart-Cut and Back-Flush |
| Pressure Control | Electronic Pressure Control (EPC) |
| Detection | FID (Flame Ionization Detector) |
| Target Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes) |
| Enclosure Rating | IP54 |
| Operating Temperature Range | 5–40 °C |
| Power Supply | 220 V AC, 50 Hz |
| Data Output | RS485, Ethernet, 4–20 mA Analog Outputs |
| Communication Protocol | HJ 212-2017 Compliant Data Transmission |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ontech710 |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Brand | Orienda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Brix-SQ |
| Pricing | Available Upon Request |
| Brand | Otisience |
|---|---|
| Model | DG Series |
| Type | Online Solvent Degasser for HPLC/UHPLC Systems |
| Flow Rate per Channel | 10 mL/min |
| Max. Operating Pressure per Channel | 5 psi |
| Dimensions (W×L×H) | 86 × 278 × 155 mm |
| Weight | 6 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Channel Configurations | 2-, 3-, or 4-Channel Parallel Degassing Modules |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories and compatible with GLP/GMP workflows requiring stable mobile phase delivery |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | Packed Column |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-4000 |
| Pricing | Upon Request |
| Flow Rate | 0.01–20 mL/min |
| Maximum Pressure | 0.0–6000 psi |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Baseline Drift | ≤2 × 10⁻⁴ AU/h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC4006 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 10,000 psi |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient +10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |