Chromatography Instruments
Filter
Showing 871–900 of 1498 results
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Model | IC-3000 |
| Pump Pressure Range | 0–35 MPa (0–5000 psi) |
| Flow Rate Range | 0.00–10.00 mL/min |
| Eluent Flow Rate | 0.1–3.0 mL/min |
| Max Operating Pressure | 35 MPa |
| Operating Temperature Range | 30–60°C (86–140°F) |
| Temperature Stability | ±0.1°C |
| Eluent Concentration Range | 0.1–100 mM (varies by eluent chemistry) |
| Brand | LUDAHY |
|---|---|
| Model | LD-MRF1700 |
| Origin | Beijing, China |
| Heating Power | 300 W |
| Temperature Control Range | 0–400 °C |
| Methanization Temperature | 350–380 °C |
| Temperature Sensor | Thermocouple |
| Conversion Tube Configuration | U-shaped, 1/8″ or 1/16″ OD × 250 mm |
| Inlet/Outlet Fitting | 1/8″ or 1/16″ compression |
| Catalytic Efficiency | ≥98% |
| Catalyst Lifetime | ≥2 years (under sulfur- and oil-free sample conditions) |
| Minimum Detectable Concentration (CO/CO₂) | ≤0.1 ppm (when coupled with FID) |
| H₂ Requirement | ≥60% of total carrier gas flow (by volume) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Capel 205 |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (extendable to ±30 kV) |
| Pressure Range | ±1–2000 mbar |
| Detection | UV-Vis (190–600 nm, Xenon lamp, ±1 nm accuracy) |
| Capillary Temperature Control | Liquid-cooled, -10 °C to +65 °C (±0.1 °C stability) |
| Injection Modes | Voltage, Pressure, Vacuum |
| Autosampler | 59-position, Eppendorf 2 mL vials, sealed cap removal |
| Cooling System | Integrated liquid-cooled恒温 water jacket |
| Power | 110/220 VAC, 50/60 Hz, 170 W |
| Dimensions | 470 × 530 × 410 mm |
| Weight | 30 kg |
| Software | Elforun-205 (PC-based, GLP-compliant audit trail, method library, customizable reporting, spectral scanning) |
| Brand | LUMEX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | Capel-105 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis | Inorganic Ions, Small Molecules, Biomolecules |
| Operating Voltage | 1–25 kV (1 kV step increment, polarity auto-switching) |
| Detection | UV Absorbance (190–380 nm) |
| Light Source | High-Intensity Deuterium Lamp |
| Injection Mode | Pressure or Electrokinetic |
| Pressure Range | 0–99 mbar (step resolution: 1 mbar) |
| Electrokinetic Injection Voltage | 1–25 kV (1 kV step) |
| Capillary Cooling | Liquid-Cooled Thermostatic System |
| Temperature Control Range | –10 °C to +30 °C (±0.1 °C stability) |
| Capillary Dimensions | 30–100 cm length × 50/75/100 µm ID |
| Current Range | 0–200 µA |
| Flushing Pressure | 0–1000 / 2000 mbar |
| Power Consumption | 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Capel-105M |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (1 kV step, polarity auto-switching) |
| Detection Wavelength | 190–400 nm |
| Light Source | High-intensity deuterium lamp |
| Pressure Range | 0–99 mbar (1 mbar step) |
| Capillary Flushing Pressure | 1000–2000 mbar (1 mbar step) |
| Capillary Dimensions | 30–120 cm length × 50 or 75 µm ID |
| Temperature Control | Water-cooled thermostating, –10 to +30 °C (±0.1 °C stability) |
| Sample Introduction | Fully automated 20-position sampler (10 inlet + 10 outlet positions), electrokinetic & pressure-driven injection |
| Current Monitoring | 0–200 µA |
| Power Supply | 110/220 VAC, 50/60 Hz, 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Software | Elforun PC-based control and data analysis suite |
| Brand | Lunan Ruihong |
|---|---|
| Model | GC-55 |
| Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–120 °C/min |
| Cool-down Time | ≤4 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Temperature Zones | 8 independent zones |
| Programmed Temperature Steps | up to 100 steps |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| EPC/EFC Resolution | 0.001 psi / 0.001 mL/min |
| Maximum Split Ratio | 1:1000 |
| Detector Support | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously) |
| Data Interface | Ethernet IEEE 802.3 (MODBUS/TCP compliant) |
| Display | 10.1″ capacitive color touchscreen |
| Brand | Lunan Ruihong |
|---|---|
| Model | GC-8850 |
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–60 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~8 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–400 kPa |
| Programmable Pressure/Flow Steps | 16 |
| Injector Max Temp | 420 °C |
| Injector Pressure Setpoint Range | 0–400 kPa |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Temperature Zones | 8 independent zones |
| Temperature Resolution | 0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously) |
| Data Interface | 10/100/1000BASE-T Ethernet (IEEE 802.3), MODBUS/TCP compliant |
| Display | 7-inch color capacitive touchscreen (hot-swappable, handheld-capable) |
| Analog-to-Digital | 24-bit low-noise ADC with baseline storage and subtraction |
| External Events | 8 inputs, 2 auxiliary outputs |
| Injection Modes | Packed column, capillary column, 6-port gas valve, optional autosampler |
| [Brand | LuNan RuiHong |
|---|---|
| Model | LC-1000D |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | ≤ 42 MPa |
| Flow Precision | ≤ 0.1% RSD |
| Injection Volume Range | 0–30 µL |
| Column Oven Temperature Range | Ambient to 80 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Detector Type | Dual-Wavelength UV-Vis Photodiode Array (PDA)-Capable Optical System |
| Compliance | AIA/CDF File Support, GLP-Compliant Audit Trail, 21 CFR Part 11 Ready (Software-Configurable)] |
| Brand | LuNan RuiHong |
|---|---|
| Model | QT-3000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry |
| Column Oven Temperature Range | +5°C above ambient to 250°C |
| Temperature Control Accuracy | ±0.1°C (column oven), ±1°C (inlet/detector) |
| Max Heating Rate | 20°C/min |
| Cooling Time | ≤8 min (180°C → 35°C) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| FID Drift | ≤0.5 mV/h |
| Maximum Temperature Program Steps | 4 |
| Injector | Water-Driven 6-Port Sampling Valve + Manual Syringe Port |
| Software | Dedicated Light Hydrocarbon Qualitative/Quantitative Data Processing Suite |
| Compliance | Designed for ASTM D1945, ASTM D1946, ISO 6974-1, and GB/T 13610-compliant light hydrocarbon analysis workflows |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | SP-6801A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3°C to 399°C |
| Temperature Stability | ±0.1°C |
| Temperature Accuracy | ±3% of setpoint |
| Oven Cooling Rate | ~8 minutes from 250°C to 50°C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (n-hexadecane in iso-octane) |
| FID Linear Range | ≥10⁶ |
| TCD Sensitivity | ≥2000 mV·mL/mg (benzene/toluene) |
| TCD Linear Range | ≥10⁴ |
| ECD Detection Limit | ≤5×10⁻¹³ g/mL (γ-HCH in iso-octane) |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | SP-7890Plus |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 4°C above ambient to 450°C |
| Heating Rate | 0.1–80°C/min |
| Cooling Rate | ≤2 min from 200°C to 100°C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 450°C |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ME99-1 |
| Price | USD 4,500 (FOB Shanghai) |
| UV Wavelengths | 220, 254, 280, 340 nm |
| Timer Range | 1 min – 24 h |
| Flow Rate | 0.1–10 mL/min |
| Fraction Capacity | 12 mL × 100 tubes |
| Temperature Control Range | 0–45 °C |
| Chromatography Cabinet Volume | 250 L |
| Net Weight | 105 kg |
| Detection Principle | UV-Vis Absorbance at Fixed Wavelengths |
| Data Acquisition | Analog signal output to external recorder or PC via dedicated chromatogram acquisition interface |
| Brand | MembraPure |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | A300 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | A300-Advanced |
| Pump Flow Rate | 0.001–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | <8 µL |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A388 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | Default Operating Temperature <10 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | membraPure |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | PR-200A |
| Pump Flow Rate | 0.001–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | <8 µL |
| Brand | MembraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | V388s Series |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 2060 IC |
| Instrument Type | Online Analyzer |
| Application Scope | Universal |
| IP Rating | IP65 |
| Modular Configuration | Single- or Dual-Channel |
| Monitoring Capacity | Up to 20 Sampling Points |
| Integrated Sample Preparation | Inline Metrohm Inline Sample Preparation (ISP) System |
| Eluent Generation | Electrolytic Eluent Generator (EG) |
| Water Supply Compatibility | ELGA PURELAB® flex 5/6 Ultra-Pure Water System |
| Software | MagIC Net™ v4.x (21 CFR Part 11 Compliant) |
| Regulatory Compliance | GLP/GMP-Ready, Audit Trail Enabled |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 850 |
| Instrument Type | Laboratory IC System |
| Application | Universal |
| Maximum Pump Pressure | 2.5 MPa |
| Flow Rate Optimization | iPump with Independent Intelligent Flow Control |
| Operating Temperature Range | 5 °C to 80 °C |
| Column Heating | Dual iColumn Support with Optional Ambient Third-Column Slot |
| Suppressor | MSM II Chemical Suppressor (Noise: 0.2 nS/cm, Solvent-Compatible, 10-Year Warranty) |
| Detector | iDetector with Onboard DSP Processing and Embedded Chromatogram Storage (up to 10 reference chromatograms) |
| Software | MagIC Net™ v3.x (21 CFR Part 11 Compliant, Audit Trail, Electronic Signatures) |
| Sample Preparation | Integrated MISP (Metrohm Inline Sample Preparation) with 858 Professional Sample Processor (USB Interface, 148-Position Tray, Auto-Recognition of >30 Vial Types) |
| Flow Path | Fully Non-Metallic (PEEK, PTFE, Ceramic), Online Degassing for Eluent & Sample |
| Hardware Recognition | Full Plug-and-Play Identification of iPump, iColumn, iDetector, MSM II, and Dosino Modules |
| Brand | Metrohm |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | 925 CN |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 50 MPa |
| Flow Rate Range | 0.001–20.000 mL/min |
| Eluent Flow Rate | 0.001–20 mL/min |
| Maximum Operating Pressure | 35 MPa (5000 psi) |
| Operating Temperature Range | 20–50 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100% |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 930 Compact |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Range | 0–50 MPa |
| Flow Rate Range | 0.001–20.000 mL/min |
| Eluent Flow Rate Range | 0.001–20.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Operating Temperature Range | 0–80 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100 % |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Laboratory Instrument |
| Model | 940 Professional |
| Instrument Category | Laboratory Ion Chromatograph |
| Application Scope | Universal |
| Pump Pressure Range | 0–50 MPa |
| Flow Rate Range | 0.001–20.000 mL/min |
| Eluent Flow Rate Range | 0.001–20.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Operating Temperature Range | 0–80 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100% |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Laboratory Instrument |
| Model | MCIC |
| Pump Pressure Rating | 0–50 MPa |
| Flow Rate Range | 0.001–20.000 mL/min |
| Eluent Flow Rate Range | 0.001–20.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Temperature Range | 0–80 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100% |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ECO IC |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 50 MPa |
| Flow Rate Range | 0.001–20.000 mL/min |
| Eluent Flow Rate Range | 0.001–20 mL/min |
| Maximum Operating Pressure | 35 MPa (5000 psi) |
| Operating Temperature Range | 20–50 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100% |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MIDAC Dynamic Calibration System |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatography Calibration Standard Generator |
| Application Scope | Universal Calibration for GC & FTIR |
| Gas Dilution Stages | Triple-stage |
| Mass Flow Controllers (MFCs) | Multi-channel digital MFC support |
| Corrosive Gas Compatibility | Yes (acidic, alkaline, organic) |
| Dilution Ratio Programmability | Yes, time-scheduled auto-run |
| Real-time Flow Monitoring | Yes |
| Repeatability | ≤ ±0.8% RSD (N₂ baseline, 10–1000 sccm) |
| Control Interface | PLC-based with 7″ TFT touchscreen (800×600) |
| PLC Cycle Time | Standard mode 160 µs |
| Onboard Memory | Display buffer 26 MB |
| Touchscreen Lifetime | ≥ 5 years (MTBF) |
| Brand | Minik |
|---|---|
| Model | MS210 |
| Origin | Beijing, China |
| Category | Other Chromatography Instruments |
| Application | Pre-analytical vaporization of liquid hydrocarbons for GC and coulometric Karl Fischer analysis |
| Compliance | GB/T 3727–2003, GB/T 6023–2008 |
| Liquid Inlet Pressure | 0.69–2.75 MPa |
| Output Flow Rate | 0–5 L/min (adjustable) |
| Vaporization Temperature Range | Up to 230 °C |
| Heating & Jacket Temperature Control Range | Ambient +5 °C to 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Mass Flow Control Range | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Sample Introduction | Liquid or gas phase |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC-8810 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Coal Industry Specific |
| Detection Limits | Permanent Gases (N₂, CO₂, O₂) < 10 ppm |
| Analysis Time | ≤ 2 min (including backflush) |
| Modular Configuration | Up to 4 independent GC channels |
| Detector Technology | NEMS-based silicon micro-TCD |
| Flow Control | Electronic Pressure Control (EPC) per channel |
| Temperature Control | Independent oven and column-zone heating per module |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Regional Classification | Domestic (China-Made) |
| Model | GC7890B |
| Pricing | Upon Request |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 (Dual-Detector) |
| Instrument Type | Laboratory Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detector Configuration | Pulsed Discharge Helium Ionization Detector (PDHID) + Secondary Detector (e.g., TCD or FID) |
| Carrier Gas | Ultra-High-Purity Helium Only |
| Linear Range | 10⁵ |
| Detection Limit | Sub-ppb for H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₆, C₂H₄, C₂H₂, H₂S, C₃H₈, C₃H₆ |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 Series |
| Instrument Type | Online Gas Chromatograph |
| Detector Configurability | Up to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID) |
| Injection Options | Packed column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector |
| Oven Temperature Range | +4 °C above ambient to 450 °C (1 °C increment) |
| Oven Temperature Stability | ±0.1 °C at 200 °C |
| Oven Programmable Stages | 16 temperature ramps |
| Cooling Rate | 260 °C to 50 °C in ~6 min |
| Temperature Zones | 8 independently controlled zones |
| Carrier Gas Control | Electronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm |
| Display | 5.7-inch color TFT touchscreen |
| Data Interface | Ethernet (IEEE 802.3), PC-controlled operation or standalone mode |
| Remote Capability | Network-enabled remote monitoring, unattended operation, distributed acquisition, centralized control |
| Multidimensional GC Support | Center-cutting and valve-switching configurations enabled |
| Software | Method-driven acquisition with full parameter storage and recall |
| Compliance | Designed for GLP/GMP environments |
