Common Laboratory Equipment
Filter
Showing 10261–10290 of 18041 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFE500 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFE500AO |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFE550 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFE600 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFE700 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFE800 |
| Pricing | Upon Request |
| Internal Volume | 749 L |
| External Dimensions (W×H×D) | 1190 × 1620 × 750 mm |
| Net Weight | 170 kg |
| Temperature Range | RT +5 °C (min. 30 °C) to 220 °C / 300 °C (optional) |
| Temperature Uniformity (DIN 12880) | ≤ ±2.2 °C at 150 °C |
| Control System | E-Class (Enhanced Electronic PID with Fuzzy Logic) |
| Sensor Configuration | Dual 4-wire Pt100 (Class A) |
| Data Logging | 1024 kB circular memory, 1-min intervals, ≥6 months retention |
| Interface | RS232, optional USB via converter |
| Software | Celsius 2007 (Windows NT4/2000/XP/Vista compatible) |
| Compliance | TB Class 1, TWW Class 3.1, TWB Class 2, GLP-ready audit trail support |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFP600 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UFP800 |
| Pricing | Upon Request |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Series | UN30, UN55, UN75, UN110, UN160, UN260, UN450, UN750, UN1060 / UF30, UF55, UF75, UF110, UF160, UF260, UF450, UF750, UF1060 |
| Temperature Range | +20 °C to +300 °C |
| Convection Options | Natural Convection (UN series) or Forced Convection with Adjustable Airflow (UF & UFplus series) |
| Air Exchange Control | Motorized damper with programmable opening angle (UFplus only) |
| Fresh Air Preheating | Integrated preheating chamber for incoming ambient air |
| Safety Certification | Complies with EN 61010-1, IEC 61000-6-3, and applicable parts of ISO 13485 when configured with A6 High-Temperature Alarm Module |
| Regulatory Use | Validated for sterilization of microbiological textiles and wrapping materials (per DIN EN ISO 17665-1 and DIN EN 285 when equipped with A6 module and operated within validated parameters) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Models | UN plus 30 / 55 / 75 / 110 / 160 / 260 / 450 / 750 |
| Temperature Range | 20–300 °C |
| Temperature Uniformity | ±0.5 °C |
| External Dimensions (H×W×D) | up to 1060 mm |
| Internal Chamber Dimensions (H×W×D) | up to 1060 mm |
| Chamber Material | AISI 304 Stainless Steel |
| Heating Configuration | Quadrilateral (4-sided) Heaters |
| Convection Options | Natural or Forced Air |
| Control Interface | Dual high-resolution TFT displays with ControlCOCKPIT™ operating system |
| Air Exchange Control | Motorized adjustable air inlet/outlet dampers |
| Fresh Air Preheating | Integrated preheating chamber for incoming ambient air |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Imported Laboratory Equipment |
| Models | UN30, UN55, UN75, UN110, UN160, UN260, UN450, UN750 |
| Temperature Range | 20–300 °C |
| Temperature Uniformity | ±0.5 °C |
| External Dimensions (H×W×D) | up to 1060 mm |
| Internal Chamber Dimensions (H×W×D) | up to 1060 mm |
| Interior Material | AISI 304 Stainless Steel |
| Heating Configuration | Quadrilateral (4-Side) Heating System |
| Convection Options | Natural or Forced Air Circulation |
| Air Exchange Control | Adjustable Ventilation Flaps with Preheated Fresh Air Inlet |
| Brand | Memmert |
|---|---|
| Origin | Germany (not USA — corrected per official Memmert documentation) |
| Model Series | UN, UNplus, UF, UFplus |
| Temperature Range | Ambient +5 K (UN/UNplus) or +10 K (UF/UFplus) to +300 °C |
| Temperature Uniformity | ≤ ±0.1 °C at ≤99.9 °C |
| External Dimensions (W×H×D) | 585 × 707 × 434 mm |
| Internal Chamber Volumes | 30, 55, 75, 110, 160, 260, 450, 750 L |
| Convection Type | Natural (UN) or Forced-air (UF) |
| Compliance | ICH Q1A, GLP/GMP-ready, FDA 21 CFR Part 11–compatible software options (AtmoCONTROL), ISO 17025 traceable calibration support |
| Air Exchange Control | Electronically adjustable via ControlCOCKPIT interface |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UNB400 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UNB500 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UNE 400 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UNE 500 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UNE 600 |
| Pricing | Upon Request |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | UN/UF/UNplus/UFplus |
| Instrument Type | Forced-Air & Natural-Convection Drying Oven |
| Temperature Range | +20 °C to +300 °C |
| Temperature Uniformity | ±0.1 °C at ≤99.9 °C |
| External Dimensions (W×H×D) | 824 × 1186 × 684 mm |
| Internal Chamber Dimensions (W×H×D) | 640 × 800 × 500 mm |
| Air Exchange Control | Electronically adjustable via ControlCOCKPIT interface |
| Optional Software | AtmoCONTROL for programmable temperature profiles and dynamic airflow regulation |
| Chamber Volumes Available | 30–750 L (eight standard capacities) |
| Brand | Memmert |
|---|---|
| Model | UNpa |
| Type | Paraffin Bath Oven (Laboratory-Scale, Sealed-Cavity Design) |
| Origin | Germany |
| Construction | Stainless Steel Interior (ASTM 304 / 1.4301), Four-Side U-Groove Heaters |
| Temperature Control | Touchscreen Interface with PID Algorithm |
| Chamber Sealing | Near-Hermetic Enclosure |
| Heating Method | Conduction-Only (No Forced Air Convection) |
| Compliance | Designed for GLP/GMP-Compliant Histology & Pathology Labs |
| Connectivity | USB Port, Ethernet Interface |
| Accessories | Adjustable Stainless Steel Grid Inserts (1–2 per chamber size), Optional Mounting Feet |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model Series | UNpa 30 / UNpa 55 / UNpa 75 / UNpa 110 / UNpa 160 |
| Temperature Range | +20 °C to +80 °C |
| Chamber Volume | 30 L / 55 L / 75 L / 110 L / 160 L |
| Heating Principle | Quadruple-wall conduction heating with passive thermal homogenization |
| Safety | Dual independent overtemperature protection (mechanical + electronic), hermetically sealed chamber design |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), CE-marked for laboratory use |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Model Variants | UNpa 30 / 55 / 75 / 110 |
| Temperature Range | 20–80 °C |
| Temperature Uniformity | ±0.5 °C |
| External Dimensions (W×H×D) | 585 × 704 × 434 mm |
| Internal Chamber Dimensions (W×H×D) | 400 × 320 × 250 mm |
| Chamber Material | AISI 304 Stainless Steel |
| Heating Configuration | Four-Side Radiant Heating |
| Compliance | CE, ISO 17025-supportive design, GLP-compatible operation |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Model Variants | VO29, VO49, VO101 |
| Temperature Range | 20–200 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Direct Shelf Heating |
| Control System | CONTROL-COCKPIT Touch Interface & AtmoCONTROL Software |
| Vacuum Integration | Compatible with External Vacuum Pumps (e.g., Memmert VAC 06/12) |
| Compliance | CE, ISO 17025-supportive design, GLP/GMP-ready audit trail capability |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | VO 29 / VO 49 / VO 101 |
| Temperature Range | +20 °C to +200 °C |
| Vacuum Range | 2 mbar to 1100 mbar |
| Heating Method | Direct plate heating with integrated Pt100 sensors |
| Control System | ControlCOCKPIT touchscreen interface + AtmoCONTROL software |
| Vacuum Pump Compatibility | Memmert chemically resistant diaphragm vacuum pump (optional, auto-synchronized) |
| Compliance | CE, ISO 17025-compatible operation, GLP/GMP-ready audit trail support |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | VO200 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +20 °C to +200 °C |
| Temperature Uniformity (at 160 °C / 50 mbar) | ≤ ±5 °C (on shelf surface) |
| Temperature Stability | ±0.3 °C (per DIN 12880) |
| Chamber Volume | ~29 L |
| Internal Dimensions (W×H×D) | 385 × 305 × 205 mm |
| External Dimensions (W×H×D) | 550 × 600 × 400 mm |
| Shelf Capacity | Up to 3 stainless steel shelves |
| Shelf Spacing | 75 mm |
| Max Load per Shelf | 20 kg |
| Max Total Load | 40 kg |
| Chamber Material | Electropolished AISI 316L stainless steel (EN 1.4404 / ASTM A240) |
| Outer Casing | Textured stainless steel with galvanized steel rear panel |
| Heating System | Direct-backplate MLC (Multi-Level Control) resistive heating elements integrated into each shelf |
| Temperature Sensing | Pt100 Class A, 4-wire, per-shelf independent probes |
| Vacuum Control | Digital electromagnetic valve with programmable setpoint range 5–1100 mbar (display resolution 1 mbar) |
| Gas Inlets | Two digitally controlled, programmable inlets (air + optional process gas) |
| Pressure Regulation | Closed-loop digital pressure control with real-time feedback |
| Safety Systems | Dual independent overtemperature protection (MLOP + mechanical TB), ASF (Automatic Setpoint Linking), microprocessor-based fault diagnostics with audible/visual alarms |
| Programming | Up to 40 temperature–vacuum profiles |
| Compliance | Designed and manufactured in accordance with EN 61010-1, EN 61000-6-3, EN 61000-6-4, and meets essential requirements of EU Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VO200 |
| Pricing | Upon Request |
| Temperature Range | +20 °C to +200 °C |
| Vacuum Range | 10–1100 mbar (digital electromagnetic valve control) |
| Chamber Volume | ~29 L |
| Internal Dimensions (W×H×D) | 385×305×205 mm |
| Max. Shelf Capacity | 3 shelves |
| Shelf Spacing | 75 mm |
| Load Capacity | 20 kg/shelf, 40 kg/oven |
| Shelf Usable Area | 365×230 mm |
| Internal Material | Electropolished stainless steel 1.4404 (ASTM 316L) |
| External Material | Textured stainless steel housing with galvanized steel rear panel |
| Door | Spring-loaded safety glass (ESG) with annular silicone gasket |
| Temperature Uniformity (at 160 °C / 50 mbar, surface) | ≤±5 °C |
| Temperature Stability (DIN 12880) | ≤±0.3 °C |
| Sensor | Pt100 Class A, 4-wire, per-shelf independent measurement |
| Control System | Microprocessor-based PID controller with MLC (Multi-Level Control), self-diagnosis, and ASF (Automatic Setpoint Linking) |
| Vacuum & Temperature Programming | Up to 40 programmable cycles, each with adjustable vacuum/temperature ramp rates and dwell times |
| Pressure Display Range | 5–1100 mbar (digital) |
| Leak Rate | ≤0.01 bar/h |
| Ultimate Vacuum | 0.01 mbar |
| Safety | Dual overtemperature protection (MLOP per shelf + mechanical limiter TB), audible/visual alarms, relay-based heater cutoff on fault, real-time monitoring of high/low temperature deviations |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model | VO200 / VO400 / VO500 |
| Temperature Range | +20 °C to +200 °C |
| Temperature Uniformity (at 160 °C / 50 mbar) | ≤ ±2 K |
| Temperature Stability | ±0.3 K |
| Vacuum Control Range | 5–1100 mbar (digital electronic pressure control) |
| Chamber Volume | 29 L / 49 L / 101 L |
| External Dimensions (W×H×D, mm) | 550×600×400 / 550×680×480 / 710×760×550 |
| Internal Chamber Dimensions (W×H×D, mm) | 385×305×250 / 385×385×330 / 545×465×400 |
| Max. Shelf Load | 20 kg per shelf |
| Max. Total Load | 40 kg / 60 kg / 60 kg |
| Heating Power (230 V, 50/60 Hz, full shelf configuration) | ~1200 W / ~2000 W / ~2400 W |
| Shelf Quantity | 3 / 4 / 4 |
| Shelf Spacing | 75 mm / 75 mm / 95 mm |
| Shelf Type | Aluminum (ASTM B209), individually heated with 4-wire Pt100 sensor and independent PID control loop |
| Safety | Triple overtemperature protection (MLOP), TB mechanical limiter, ASF automatic setpoint linkage, Class 3.1 overtemperature safety controller (DIN 12880), audible/visual alarms, ESG safety glass door with silicone ring seal |
| Compliance | DIN 12880:2007-05, EN 61010-1, IEC 61000-6-3, CE marked |
| Software | Celsius software (free, Windows-based), supports unlimited-stage programming, real-time monitoring, audit-trail-capable data logging (1024 KB internal memory, 1-min sampling, ~3 months retention), 21 CFR Part 11-ready configuration options |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | VO29 / VO49 / VO101 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +5 °C above ambient to 200 °C |
| Temperature Stability | ≤ ±0.3 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Vacuum Control Range | 5–1100 mbar |
| Ultimate Vacuum | ≤2 mbar |
| Chamber Dimensions (W×D×H) | 340×340×250 mm (VO29), 420×420×280 mm (VO49), 520×520×370 mm (VO101) |
| External Dimensions (W×D×H) | 520×625×645 mm (VO29), 620×725×745 mm (VO49), 720×825×845 mm (VO101) |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Direct Shelf Heating |
| Operating Ambient Temperature | 5–40 °C |
| Shelf Interfaces | 1 (VO29), 2 (VO49 & VO101) |
| Safety Features | Over-/Under-Temperature Protection, Acoustic/Visual Alarm, Explosion-Resistant Door, Integrated Fault Diagnosis System |
| Connectivity | Ethernet, USB, Dual TFT Color Displays |
| Software | AtmoCONTROL (via USB stick or network) |
| Compliance | Designed for GLP/GMP environments |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | VO400 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +20 to +200 °C |
| Internal Chamber Dimensions (W×H×D) | 385 × 385 × 330 mm |
| External Dimensions (W×H×D) | 710 × 760 × 550 mm |
| Chamber Material | Electropolished Stainless Steel 1.4404 (ASTM 316L) |
| Heating Method | Internal Radiant Plate Heating with Forced Convection |
| Vacuum Control Range | 5–1100 mbar (digital electromagnetic valve control) |
| Max. Shelf Capacity | 4 adjustable shelves (75 mm spacing) |
| Load per Shelf | 20 kg |
| Total Load Capacity | 60 kg |
| Temperature Uniformity at 160 °C / 50 mbar | ≤ ±5 K (surface) |
| Temperature Stability (DIN 12880) | ≤ ±0.3 K |
| Sensor System | Individual Pt100 Class A (4-wire) per shelf, integrated MLC (Multi-Level Control) architecture |
| Safety Features | Dual independent overtemperature protection (electronic ASF + mechanical TB), door-interlocked rapid venting, leak rate ≤ 0.01 bar/h, residual vacuum ≤ 0.01 mbar |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VO400 |
| Pricing | Upon Request |
| Temperature Range | +20 °C to +200 °C |
| Vacuum Range | 5–1100 mbar (digital display), programmable down to 0.01 mbar ultimate vacuum |
| Chamber Volume | ~49 L |
| Internal Dimensions (W×H×D) | 385×385×330 mm |
| External Dimensions (W×H×D) | 550×680×480 mm |
| Max. Shelf Load | 20 kg per shelf / 60 kg total |
| Shelf Spacing | 75 mm |
| Max. Shelves | 4 |
| Shelf Usable Area | 365×310 mm |
| Internal Material | Electropolished Stainless Steel 1.4404 (ASTM 316L) |
| External Casing | Textured Stainless Steel with Galvanized Steel Rear Panel |
| Door | Tempered Safety Glass (ESG) with Spring-Loaded Mechanism & Annular Silicone Gasket |
| Temperature Uniformity (160 °C / 50 mbar, surface) | ≤±5 °C |
| Temperature Stability (DIN 12880) | ≤±0.3 °C |
| Sensor | Pt100 Class A, 4-wire, independent per shelf |
| Control System | MLC Multi-Level Control with Integrated Diagnostics |
| Programmability | Up to 40 temperature/vacuum profiles |
| Safety | Dual Overtemperature Protection (ASF + MLOP + mechanical TB), microprocessor-based monitoring, audible/visual alarms, automatic heater cutoff on fault |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | VO500 |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient + 5 °C to 200 °C |
| Temperature Uniformity (at 160 °C / 50 mbar) | ≤ ±5 °C (surface) |
| Temperature Stability | ±0.3 °C |
| Chamber Dimensions (W×H×D) | 545 × 465 × 400 mm |
| External Dimensions (W×H×D) | 710 × 760 × 550 mm |
| Chamber Volume | ~101 L |
| Interior Material | Electropolished Stainless Steel 1.4404 (ASTM 316L) |
| Exterior Material | Textured Stainless Steel with Galvanized Steel Back Panel |
| Heating Method | Internal Multi-Level Control (MLC) with Direct-Attached PTC Heating Elements on Perforated Stainless Steel Shelves |
| Shelf Configuration | Up to 4 Adjustable Shelves (95 mm spacing), Load Capacity: 20 kg/shelf (60 kg total) |
| Vacuum Control | Digital Electromagnetic Valve, Adjustable Range: 5–1100 mbar (displayed), Programmable Setpoint from 10–1100 mbar |
| Pressure Accuracy | ±5 mbar |
| Gas Inlets | 2 Independently Controlled (Air & Optional Process Gas), Tubing Material: 1.4571 (ASTM 316Ti) |
| Safety Systems | Dual Pt100 Class A Sensors per Shelf (4-wire), MLOP Multi-Level Overheat Protection, Mechanical Temperature Limiter (TB), Microprocessor-Based Thermal Monitoring with ASF (Automatic Setpoint Linking), Audible/Visual Alarms, Door-Interlocked Rapid Venting, Leak Rate ≤ 0.01 bar/h, Final Vacuum ≤ 0.01 mbar |
| Programming | 40 Programmable Temperature–Vacuum Profiles, Each with Up to 99 Segments |
| Compliance | Designed and tested per DIN 12880, EN 61000-6-3, EN 61000-6-4, IEC 61010-1, and compatible with GLP/GMP documentation requirements including audit-trail-capable operation when used with MEMControl software |