Common Laboratory Equipment
Filter
Showing 11461–11490 of 17931 results
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Precision Hydrogen 100 |
| Hydrogen Generation Principle | Pure Water Electrolysis via Proton Exchange Membrane (PEM) |
| Output Flow Rate | 100 cm³/min |
| Output Pressure | 100 psi (6.9 bar) |
| Hydrogen Purity | 99.9995% |
| Power Consumption | 309–422 W |
| Safety Certifications | CE, UKCA, UL/CSA-compliant design |
| Dimensions (H×W×D) | 360 × 280 × 420 mm |
| Weight | 18.5 kg |
| Internal H₂ Storage Volume | < 15 mL (at operating pressure) |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Peak Precision Hydrogen 1200 |
| Hydrogen Generation Principle | Pure Water Electrolysis via Proton Exchange Membrane (PEM) |
| Output Flow Rate | 1200 mL/min |
| Output Pressure | 100 psi (6.9 bar) |
| Hydrogen Purity | 99.9995% |
| Power Consumption | 600 W |
| Safety Certifications | CE, UKCA, UL-compliant design |
| Warranty | 3-year standard warranty on electrolyzer stack and control electronics |
| Dimensions (W×D×H) | 340 × 500 × 420 mm |
| Weight | 28 kg |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Precision Hydrogen 200 |
| Hydrogen Generation Principle | Pure Water Electrolysis via Proton Exchange Membrane (PEM) |
| Output Flow Rate | 200 cm³/min |
| Output Pressure | 100 psi (6.9 bar) |
| Hydrogen Purity | 99.9995% |
| Power Consumption | 367–422 W |
| Safety Certifications | CE, UKCA, UL/CSA-compliant design |
| Dimensions (W×D×H) | 280 × 440 × 380 mm |
| Weight | 18.5 kg |
| Internal H₂ Storage Volume | < 50 cm³ |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Peak Precision Hydrogen 300 |
| Hydrogen Generation Principle | Pure Water Electrolysis via Proton Exchange Membrane (PEM) |
| Output Flow Rate | 300 cm³/min |
| Output Pressure | 100 psi (6.9 bar) |
| Hydrogen Purity | 99.9995% |
| Power Consumption | 405–422 W |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Precision Hydrogen 450 |
| Hydrogen Generation Principle | Pure Water Electrolysis via Proton Exchange Membrane (PEM) |
| Output Flow Rate | 450 cm³/min |
| Output Pressure | 100 psi (6.9 bar) |
| Hydrogen Purity | 99.9995% |
| Power Consumption | 422 W |
| Warranty | 3-year standard warranty on PEM stack and critical components |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Precision Hydrogen Trace 500 |
| Hydrogen Generation Principle | Pure Water Electrolysis via Proton Exchange Membrane (PEM) |
| Output Flow Rate | 500 cm³/min |
| Output Pressure | 100 psi (6.9 bar) |
| Hydrogen Purity | 99.9999% (6.0 N) |
| Maximum Power Consumption | 600 W |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Precision Hydrogen Trace 500cc |
| Hydrogen Generation Principle | PEM Electrolysis of Deionized Water |
| Output Flow Rate | 500 cc/min |
| Output Pressure | 0–100 psi (0–6.9 bar) |
| Hydrogen Purity | 99.9999% (6.0 N) |
| Dew Point | < –70 °C (< 1 ppmv H₂O) |
| Power Consumption | 1380 W |
| Dimensions (H×W×D) | 440 × 320 × 500 mm |
| Weight | 28 kg |
| Safety Certifications | CE, UKCA, UL/CSA 61010-1, IEC 62368-1 |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Peak Scientific |
| Product Type | Imported |
| Model | Precision Zero Air 3L |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rate | 3 L/min |
| Output Pressure | 80 psi |
| Total Hydrocarbon (THC) Content | < 0.05 ppm |
| Particle Filtration | < 0.01 µm |
| Startup Time | 60 min |
| Operating Temperature | 5–35 °C |
| Electrical Requirement | 110–230 VAC, 50/60 Hz |
| Power Consumption | 1.54 kW |
| Dimensions (W×D×H) | 15.1" × 21.3" × 15.9" |
| Weight | 41 kg (90.3 lbs) |
| Noise Level | Low-noise operation |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Import Status | Imported |
| Model | Precision Zero Air |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Pressure | 80/100 psi |
| Hydrocarbon Content (NMHC) | <0.05 ppm |
| Particle Filtration | <0.01 µm |
| Flow Rate Options | 1.5 L/min |
| Inlet Air Requirement | 120–145 psi, ≥35 L/min |
| Power Supply | 110 V / 230 V, 144 VA |
| Dimensions (H×W×D) | 156 mm × 380 mm × 539.5 mm |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | Solaris Nitrogen Generator |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 10 L/min |
| Output Pressure | 100 psi / 690 kPa |
| Nitrogen Purity | 99.5% |
| Dew Point | −50 °C |
| Dimensions (D×W×H) | 416 mm × 540 mm × 156 mm |
| Weight | 12 kg |
| Power Supply | 100–230 VAC, 50/60 Hz, 0.03 A |
| Power Consumption | 6.9 W |
| Operating Temperature | 5–35 °C |
| Inlet Air Requirement | 30 L/min minimum, 80–130 psi (5.5–8.9 bar), ISO 8573-1:2010 Class 1.4.1 |
| Certifications | CE, FCC |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Solaris Air Compressor |
| Output Flow Rate | 30 L/min |
| Output Pressure | 120 psi (8.27 bar) |
| Dew Point | < 3 °C |
| Voltage Options | 100–115 V AC ±10%, 50/60 Hz / 230 V AC ±10%, 50/60 Hz |
| Power Consumption | 594–1150 W |
| Dimensions (D×W×H) | 416 × 540 × 406 mm |
| Weight | 41.5 kg |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SOLARIS XE |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | Up to 35 L/min |
| Output Pressure | Up to 116 psi |
| Nitrogen Purity | Up to 99.5% |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PEC2000 |
| Reaction Pressure | Ambient (0 bar gauge) |
| Reaction Temperature | Room Temperature (20–25 °C) |
| Catalyst Loading Capacity | Not Applicable (Flow-through / Immobilized Electrode Configuration) |
| Light Source Power | 300 W (Adjustable 150–300 W) |
| Illumination Uniformity | ≤3% |
| Long-term Intensity Drift | ≤2% |
| Spectral Range | 350–800 nm |
| Effective Irradiation Area | 10×10 to 50×50 mm² |
| Irradiance | Up to 3000 mW/cm² |
| Optical Power Measurement Range | 0–20 W (Accuracy: ±1 mW) |
| Chopping Interval | 1 s – 30 min |
| X-axis Translation Range (Chamber) | 0–80 mm |
| Y-axis Translation Range (Turntable) | 0–10 mm |
| Electrochemical Compatibility | Three-electrode configuration (working, counter, reference), integrated gas-tight lid |
| Reactor Volume | 180 mL (Effective Liquid Volume ≈90 mL) |
| Photodetector Spectral Response | 0.2–11 μm |
| Brand | CME (Zhongjiao Jinyuan) |
|---|---|
| Model | PECK125 |
| Body Material | Fused Quartz |
| Dimensions | 50 mm × 50 mm × 50 mm (125 mL) |
| Optical Configuration | Four-side optical access |
| Cap Material | PTFE |
| Standard Electrode Set | Pt wire counter electrode, Ag/AgCl reference electrode, Pt electrode clamp for working electrode |
| Compliance | Designed for ISO/IEC 17025-aligned electrochemical testing environments |
| Brand | PECULIAR |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Omniapure CN |
| Purified Water Grade | ASTM Type III |
| Resistivity | 18.2 MΩ·cm at 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Brand | PECULIAR |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Instrument Type | Recirculating Water-Cooled Soundproof Enclosure |
| Noise Reduction | 30 dB(A) |
| Perceived Noise Reduction | >90% |
| Exhaust Airflow | 480 m³/h |
| Dimensions (L×W×H) | 479 × 329 × 415 mm |
| Weight | 20 kg |
| Fire-Retardant Material Compliance | UL 94 V-0 certified |
| Over-Temperature Alarm | Integrated thermal cutoff with audible/visual alert |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | PQSX2-4-7 |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 4 kW |
| Heating Time to Max Temp | 28 min |
| Heating Chamber Material | Imported Ceramic Fiber |
| Internal Dimensions | 300 × 200 × 120 mm |
| Control Interface | 7-inch Touchscreen Controller |
| Thermocouple Type | K |
| Voltage | AC 220 V / 50 Hz |
| Programmable Stages | 30 |
| Stored Programs | 16 |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | PQZL-1000 |
| Heating Method | Far-Infrared Ceramic Radiant Heating |
| Cooling System | Integrated Compressor-Based Closed-Loop Chiller |
| Distillation Channels | 6 Independent Units |
| Control Interface | 7-inch HD Touchscreen LCD |
| Temperature Range | Ambient to 300 °C |
| Heating Ramp Time | <8 min |
| Distillation Modes | Gravimetric (1–600 g, ±2 g accuracy) and Timed (1–600 min) |
| Endpoint Detection | Dual-mode (load cell + timer) with anti-suckback valve activation |
| Cleaning | Integrated auto-cleaning pump |
| Preloaded Methods | 7 factory-default protocols + user-customizable method storage |
| Single-Channel Control | Yes |
| Compliance | Designed for GLP-compliant laboratory workflows requiring audit-ready operation logs |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | PQZL-1000W |
| Heating Method | Far-infrared Ceramic Radiant Heating |
| Temperature Range | Ambient to 300°C |
| Heating Channels | 6 Independent |
| Control Interface | 7-inch HD Touchscreen LCD |
| Control Core | Microcontroller-based Embedded System |
| Distillation Modes | Gravimetric (1–600 g, ±2 g accuracy) & Timed (1–600 min) |
| Cooling | External Compressor-based Refrigerated Circulator |
| Auto-endpoint Detection | Dual-mode (mass-based + timer-based) |
| Anti-suckback Protection | Integrated Solenoid Valve & Flow Locking Mechanism |
| Auto-cleaning Function | Built-in Peristaltic Cleaning Pump |
| Preloaded Methods | 7 Standard Protocols + User-Defined Method Storage |
| Single-Channel Independence | Yes |
| Warm-up Time | <8 min |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SDC-1000 |
| Instrument Type | Nitrogen Blow-Down Concentrator |
| Temperature Range | Ambient +5°C to 100°C (±0.3°C) |
| Temperature Control Accuracy | ±0.3°C |
| Sample Capacity | 1–12 positions |
| Nitrogen Pressure Range | 0–0.10 MPa (10 adjustable steps, 0.01 MPa increment) |
| External N₂ Supply Pressure | 0.20–0.80 MPa |
| Max. Gas Consumption | ~500 mL/min per channel at 0.10 MPa |
| Endpoint Detection | Optical dryness sensor per channel |
| Endpoint Volumes | 1.0 mL, 0.5 mL, or near-dry (~0.1 mL) |
| Timer Range | 0–9999 min |
| Heating Power | 2000 W |
| Dimensions | 600 × 540 × 400 mm |
| Weight | 28 kg |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-08S |
| Pricing | Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S2 |
| Heating Element Type | Opal White Quartz Tube with Embedded Resistive Heating Alloy |
| Radiation Spectrum | Predominantly Far-Infrared (λ = 3–10 µm) |
| Max Operating Temperature | 550 °C (Continuous), 600 °C (Short-Term) |
| Temperature Control Accuracy | ±2 °C |
| Ramp Rate | Programmable, 0.1–20 °C/min |
| Sample Capacity | 8 × 16 mm or 8 × 20 mm Digestion Tubes |
| Power Supply | 220 V AC, 50/60 Hz |
| Safety Compliance | IEC 61010-1, GB/T 12804-2022 |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S2 |
| Heating Method | Quartz Infrared Tubular Heater |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 550 °C |
| Temperature Stability | ±1% of setpoint |
| Ramp Time | ≤10 min to 400 °C (preheating) |
| Power Supply | AC 220 V |
| Rated Power | 1600 W |
| External Dimensions (W×D×H) | 655 × 320 × 210 mm |
| Digestion Tube Dimensions | Ø42 × 300 mm |
| Safety Features | Dual independent switches (power & heating), over-current protection, earth-leakage circuit breaker, stainless-steel fume hood with integrated SO₂ scrubbing duct |
| Control System | Microcontroller-based digital PID temperature controller |
| Compliance | CE-marked heating module |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-08S3 |
| Pricing | Available Upon Request |
| Control Interface | LCD Display with Timer + Multi-Stage Programmable Ramp |
| Heating Method | Infrared Radiation via Quartz Tube |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 680 °C |
| Preheating Time to 400 °C | ≤15 min |
| Temperature Stability | ±1 °C |
| Insulation | Dual-Layer (Ceramic Fiber + Air Gap) |
| Input Voltage | AC 220 V |
| Rated Power | 1.6 kW |
| Digestion Tube Dimensions & Material | 300 mm × 42 mm OD, High-Purity Fused Quartz |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S3 |
| Heating Method | Infrared radiation via opal white quartz tubes |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 550 °C |
| Temperature Stability | ±1 °C |
| Ramp Time | 15 min to 400 °C (preheat) |
| Control Interface | LCD display with n-step programmable ramping and timer |
| Insulation | Dual-layer (ceramic fiber + air gap) |
| Power Supply | AC 220 V |
| Rated Power | 1.6 kW |
| Safety Features | Dual independent switches (power & heating), over-current protection, earth leakage protection, integrated explosion-proof cap, corrosion-resistant stainless steel fume hood with lift mechanism and acid-resistant tray |
| Compliance | CE-marked |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-180 |
| Heating Method | Electric (stainless steel heating element) |
| Cooling Method | Recirculating water cooling |
| Distillation Speed | 5–8 min per 250 mL sample |
| Warm-up Time | 10–15 min |
| Endpoint Control | Quantitative volume detection + automatic termination |
| Heating Power | Adjustable up to 1500 W |
| Distillation Flow Rate | 15–30 mL/min |
| Sample Capacity | ≤20 g (solid) or ≤30 mL (liquid) per run |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Repeatability | RSD ≤0.5% |
| Data Storage | 10 programmable distillation/acid-addition protocols |
| Safety Features | Real-time liquid level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid- and alkali-resistant) |
| Tubing | Custom corrosion-resistant polymer tubing (rated for long-term HCl/NaOH exposure) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, inlet temperature <20 °C |
| Net Weight | 15 kg |
| Dimensions (W×D×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-18S2 |
| Pricing | Available Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-18S2 |
| Heating Method | Infrared radiation via quartz tubes |
| Number of Digestion Ports | 18 |
| Temperature Range | Ambient to 680 °C |
| Temperature Stability | ±1 °C |
| Ramp Time to 400 °C | 15 min |
| Dual Insulation | Ceramic fiber (silica-alumina) + air gap |
| Power Supply | AC 220 V |
| Rated Power | 1600 W |
| Digestion Tube Dimensions | Ø25 mm × 300 mm |
| Control System | Digital PID with 64-step programmable ramping and timer |
| Safety Features | Over-temperature, over-current, and over-pressure protection |
| Exhaust System | Stainless steel fume duct with integrated SO₂ absorption path |
| Optional Accessories | 5000-program touchscreen controller, SF-100 acid gas neutralization system, explosion-proof sample covers |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20S2 |
| Control System | Microcontroller-based (64-step programmable ramp + timer) |
| Heating Method | Far-infrared radiation from opal milky quartz tubes |
| Number of Digestion Ports | 20 |
| Temperature Range | Ambient to 550 °C |
| Ramp Time | 20 min (ambient to 400 °C) |
| Temperature Stability | ±1 °C |
| Voltage | AC 220 V |
| Power Consumption | 1950 W |
| Dimensions (L×W×H) | 655 × 340 × 210 mm |
| Digestion Tube Compatibility | Ø42 × 300 mm |
| Safety Features | Dual independent switches (power & heating), over-current protection, earth-leakage circuit breaker, stainless steel fume hood with SO₂ scrubbing duct |
| Optional Accessory | Sample explosion guard |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20S3 |
| Heating Method | Infrared radiation via quartz tubes |
| Number of Digestion Ports | 20 |
| Temperature Range | Ambient to 680 °C |
| Temperature Stability | ±1 °C |
| Programmable Control | LCD display with timer and multi-stage ramp/soak programming |
| Ramp Time | ≤20 min to 400 °C |
| Insulation | Dual-layer (ceramic fiber + air gap) |
| Voltage | AC 220 V |
| Power Rating | 1.95 kW |
| Digestion Tube Dimensions | Ø30 × 42 mm (quartz) |
| Safety Features | Overcurrent protection, earth leakage protection, dual independent power switches (main power + heating module), integrated stainless-steel fume hood with exhaust port for SO₂ and acid vapors |