Common Laboratory Equipment
Filter
Showing 11491–11520 of 17931 results
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20S3 |
| Heating Method | Far-infrared quartz radiation |
| Number of Digestion Ports | 20 |
| Temperature Range | Ambient to 550 °C |
| Temperature Stability | ±1 °C |
| Programmable Control | LCD-based, multi-step ramping (timer + n-segment program) |
| Power Supply | AC 220 V |
| Rated Power | 1950 W |
| Thermal Insulation | Dual-layer (ceramic fiber + air gap) |
| Safety Features | Over-current protection, earth-leakage circuit breaker, integrated explosion-proof vent, corrosion-resistant stainless steel fume hood with lift mechanism and acid-resistant tray |
| Compliance | CE-marked |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20T |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Max Heating Temperature | 680 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Infrared Radiation via Quartz Heaters |
| Programmable Temperature Stages | ≥64 |
| Safety Features | Overcurrent Protection, Earth Leakage Protection, Dual Independent Power/Heating Switches |
| Control System | PID-Based Digital Temperature Controller |
| Sample Vessel Material | PTFE (Polytetrafluoroethylene) Digestion Tubes |
| Compliance | CE Certified |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3800 |
| Instrument Type | Quartz Glass Distillation Apparatus |
| Heating Method | Electric heating (stainless steel heating element) |
| Cooling Method | Recirculating water cooling |
| Distillation Rate | 15–30 mL/min (adjustable) |
| Heating-up Time | 10–15 min |
| End-point Control | Quantitative volume-based automatic termination |
| Steam Power | 750–1500 W (adjustable) |
| Dimensions | ~370 × 300 × 680 mm |
| Housing Material | Acid- and alkali-resistant ABS |
| Nitrogen Detection Range | 0.1–210 mg per sample |
| Sample Capacity | ≤5 g solid or ≤15 mL liquid per run |
| Distillation Time per Sample | 3–9 min |
| RSD | ≤0.5% |
| Recovery Rate | ≥99.5% |
| Reagent Dispensing Accuracy | ±0.05 mL |
| Titration Range | 0–99 mL standard acid (with 10× acid replacement capability) |
| Display | 10.1-inch touchscreen with Chinese UI |
| Data Output | Thermal printer + USB export + LIMS-compatible interface |
| Safety Features | Dry-run protection for steam generator, condensate flow & temperature monitoring, reagent level sensing, safety door & digestion tube presence detection, condensate interruption shutdown |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-48S2 |
| Number of Digestion Positions | 48 |
| Temperature Range | Ambient to 680 °C |
| Heating Rate | 22 min (to 400 °C, empty chamber) |
| Temperature Uniformity | ±1 °C |
| Voltage | AC 220 V |
| Power Rating | 1950 W |
| Digestion Tube Dimensions | 25 mm × 300 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-800 |
| Sample Capacity | ≤5 g (solid) / ≤15 mL (liquid) |
| Nitrogen Range | 0.08–200 mg N |
| Recovery Rate | >99.5% |
| Precision (RSD) | ≤0.5% |
| Distillation Time | 1–99 min |
| Distillation Rate | 14–28 mL/min (adjustable) |
| Power Adjustment | 750–1500 W |
| Cooling Water Requirement | ≥1.5 L/min at ≤20 °C, min. pressure 0.15 MPa |
| Data Storage | ≥100 distillation programs, ≥1000 sample records |
| Safety Features | Dual-level digestion flask level sensing, real-time cooling water flow/pressure monitoring, reagent level detection (H₂SO₄, NaOH, boric acid, diluent), digestion chamber temperature monitoring, condensate temperature cutoff, interlocked safety door sensor, intermittent alkali addition control |
| Construction | Monolithic ABS engineering plastic chassis |
| Dimensions | 370 × 300 × 680 mm |
| Electrical | 220 V AC, 50 Hz, 3.5–7 A |
| Brand | Ted Pella |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PELCO easiGlow™ 91000 |
| Plasma Current | 0–30 mA |
| Power | 30 W |
| Electrode Polarity | Reversible (Positive/Negative) |
| Sample Stage Diameter | 75 mm |
| Stage Height Adjustment | 1–25 mm |
| Delay Time | 0–14,400 s |
| Treatment Time | 0–900 s |
| Chamber Dimensions | 120 × 100 mm |
| Gas Inlets | Two 6 mm ports |
| Vacuum Control | Electromechanical proportional valve with Pirani gauge |
| Operating Vacuum Range | 1.1–0.20 mbar |
| Ultimate Vacuum (with optional GD4 pump) | 0.03 mbar |
| Pump Speed (GD4) | 2.5 m³/hr |
| Display | 3″ LED-backlit touchscreen with five dedicated function keys |
| Control Modes | Auto-programmable (up to 4 user-defined protocols) + Manual mode |
| Safety | Dual hardware/software vacuum interlock |
| Dimensions (unit) | 305 × 292 × 230 mm (L×W×H) |
| Weight (unit) | 6.26 kg |
| Optional GD4 Pump Dimensions | 337 × 138 × 244 mm |
| GD4 Weight | 11 kg |
| Electrical Requirement | 230 V, 50 Hz, 10 A |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Model | PLD-DGCS |
| Gas Channels | Up to 8 independent mass flow-controlled inlets |
| Output Ports | Dual configurable outlets (selectable single or simultaneous output) |
| Max Outlet Pressure | 0.4 MPa (gauge) |
| Temperature & Pressure Monitoring | Integrated sensors per outlet |
| Control Modes | Manual (fixed-ratio) and Time-Programmed (dynamic ratio/flow ramping) |
| Display | 7-inch capacitive touchscreen interface |
| Standard Conditions Reference | 0 °C, 101.325 kPa (for all stated flow values) |
| Compliance | Designed for GLP-compliant gas standard generation and traceable calibration workflows |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-CTPR-O500 |
| Reactor Volume | 3 × 300 mL (modular) |
| Operating Pressure | 0–0.3 MPa |
| Temperature Range | −20 to 100 °C |
| Light Source | 800 W low-pressure mercury lamp (UVC, ~254 nm) |
| Illumination Geometry | Internal cylindrical irradiation |
| Reactor Tube Material | UV-transparent polymer (Φ6 mm standard, customizable) |
| UV Window Material | High-transmittance quartz-glass |
| Outer Housing | Reflective polymer cylinder (Φ140 × 1500 mm) |
| Overall Dimensions | 1000 × 1000 × 1900 mm |
| Weight | 50 kg |
| Configuration | Modular, vertical/horizontal adaptable |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLR-GPTR (Gas-Phase) |
| Pressure Rating | 0.3 MPa |
| Volumes Available | 25 mL, 50 mL, 100 mL, 200 mL |
| Built-in Catalyst-Zone Heating | Optional (denoted by “T” suffix) |
| Max. Heating Temperature | 300 °C |
| Temperature Control | 10-segment programmable, ±0.5 °C accuracy |
| Sensors | Integrated pressure transducer and catalyst bulk temperature sensor |
| Reactor Geometry | Flat-bottomed, low-diffusion-height design |
| External Modularity | Compatible with humidity control, mass flow controllers, and online gas analyzers (e.g., GC, FTIR, MS) |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WLK-1000 |
| Pricing | Available Upon Request |
| Light Source Wavelength Range | 255–760 nm (Multi-wavelength Selectable) |
| Optical Power Output | 10–120 W (Adjustable) |
| Temperature Control Range | −20 to +80 °C (Precision Thermostatic Regulation) |
| Reaction Volume per Chip Unit | 5 µL / 10 µL |
| Liquid Flow Rate | 0.1–70 mL/min |
| Compatible Phases | Liquid–liquid (homogeneous & heterogeneous) |
| Chip Substrate Materials | Fused Silica, Borosilicate Glass, PDMS, Polymer |
| Footprint | 620 mm × 540 mm × 430 mm |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CHF-XM Series |
| Pricing | Available Upon Request |
| Light Output Modes | Point Source, Collimated Beam, Fiber-Coupled Output |
| Point Source Diameter | 4–6 mm |
| Collimated Beam Diameter | 50 mm |
| Beam Divergence | ≤0.85° (at working distance < 250 mm) |
| Spectral Range | 300–1100 nm |
| Irradiance Uniformity (Φ60 mm) | ≤ ±11% |
| Local Uniformity (2 cm × 2 cm area) | ≤ ±5% |
| Focusing Capability | Adjustable between point source and Φ60 mm collimated output |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | FZ-A |
| Wavelength Range | 400–1000 nm |
| Irradiance Range | 0.1–1.999×10⁵ µW/cm² |
| Accuracy | ±5% (vs. NIM reference standard) |
| Cosine Error | f₂ ≤ 4% |
| Response Time | 1 s |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% RH |
| Dimensions | 160 × 78 × 43 mm |
| Weight | 0.2 kg |
| Power Supply | 9 V alkaline battery (6F22) or USB 5 V adapter |
| Detector Diameter | 27 mm |
| Sensing Aperture | 7 mm |
| Detector Height | 21.5 mm |
| Compliance | Meets Chinese National Class I Illuminance Meter Standard (JJG 245–2005) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | L-Series |
| Reactor Type | Flow-through Photochemical Reactor |
| Construction Material | Borosilicate Glass |
| Operating Pressure | Medium-pressure (up to 0.6 MPa) |
| Reaction Volume | 1.2 L (photoreaction tube), 5 L (feed reservoir) |
| Tube Inner Diameter | 40 mm |
| Standard Wavelength | 240 nm |
| Standard Light Power | 600 W (flexible LED) |
| Max Flow Velocity | ≤0.65 m/s |
| Temperature Range | Ambient (with dual water-jacket cooling) |
| Compliance | Designed for GLP-compliant photoreaction development and scale-up studies |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | Labsolar-6A Gas-Phase |
| Construction Material | Borosilicate Glass (Duran®-grade) |
| Gas Circulation Time | <10 min for H₂, O₂, CH₄, CO |
| Oxygen Leakage Rate | ≤0.1 μmol/h |
| Detection Limits (� | mol): H₂: 0.05 |
| O₂ | 0.1 |
| CH₄/CO | 0.0005 |
| Quantitative Loop Options | 0.6 mL or 2 mL |
| System Volume | 65 mL |
| Operating Pressure Range | 0 kPa (vacuum) to ambient pressure |
| Vacuum Degree | ≤1.5 kPa (absolute) |
| Temperature Control | 10-segment programmable, ±0.1°C accuracy, up to 200°C |
| Valve Count | 7 |
| Sealing Medium | Dow Corning® High-Vacuum Grease (-40–200°C) |
| Compliance | Designed for GLP-compliant catalyst evaluation under ASTM E2500 and ISO/IEC 17025-aligned workflows |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 6A Liquid-Phase |
| Pricing | Upon Request |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Labsolar-6A |
| Reactor Volume | 150 mL (excl. reactor cavity) |
| Construction Material | Borosilicate glass |
| Operating Pressure Range | 0 kPa to atmospheric pressure |
| Ultimate Vacuum | ≤1.5 kPa (absolute) |
| Vacuum Leakage Rate | ≤1 μmol O₂/24 h |
| Gas Mixing Time | <10 min (H₂, O₂, CH₄, CO) |
| Quantitative Loop Options | 0.6 mL or 2 mL |
| Circulation Line ID | 3 mm |
| Total System Dead Volume | 65 mL |
| Temperature Control Range | Ambient to 200 °C (10-segment programmable, ±0.1 °C accuracy) |
| Detection Limits (� | mol): H₂: 0.05 |
| O₂ | 0.1 |
| CH₄/CO | 0.0005 |
| Repeatability (RSD) | <3% (n=4) |
| Linearity (R²) | >0.9995 (H₂: 100 μL–10 mL) |
| Displacement per Cycle | 6 mL |
| Pump Type | Passive magnetic-drive piston pump (wire-free, no electrolytic H₂ interference) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | Labsolar-IIIAG |
| Temperature Range | −40 °C to 200 °C |
| Reaction Vessel Count | 1 |
| Reaction Volume | 150 mL |
| Vacuum Level | ≤0.1 MPa (absolute) |
| Gas Loop Flow Path ID | 3 mm |
| Quantitative Loop Volume | 1.5 mL |
| Gas Storage Bottle Capacity | 250 mL |
| Condenser Type | Spherical Reflux Condenser |
| Cold Trap | Integrated |
| Vacuum Pump | Single-Stage Rotary Vane, ≥6 L/s |
| Valve Count | 13 |
| Sealing Grease | Dow Corning High-Performance Vacuum Grease (−40 °C to 200 °C) |
| Construction Material | Borosilicate Glass (3.3), Chemically Inert |
| Gas Sampling | Manual Online Sampling via Glass Multi-Position Valve with Quantitative Loop |
| Magnetic Drive Circulation Pump | Brushless, Wire-Free, ≥4000 rpm |
| Linearity (H₂) | R² > 0.999 (100 μL–10 mL) |
| Repeatability (RSD) | <3% (n=4) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Labsolar-IIIAG |
| Pricing | Available Upon Request |
| Vacuum Level | ≤0.1 MPa (absolute) |
| Operating Pressure Range | 0 kPa to ambient pressure |
| Gas Tightness | ≤1 kPa pressure change over 24 h |
| Tubing Material | High-borosilicate glass |
| Minimum Tubing ID | 3 mm |
| Total System Volume | 150 mL |
| Sampling Loop Volume | 1.5 mL |
| Gas Storage Vessel | 250 mL |
| Condenser Type | Spherical condenser |
| Cold Trap | Integrated for low-boiling component separation |
| Vacuum Pump | Single-stage rotary vane pump, pumping speed ≥6 L/s |
| Magnetic Circulator Speed | ≥4000 rpm |
| H₂ Calibration Linearity | R² > 0.999 in range 100 μL–10 mL |
| Repeatability (RSD) | <3% for quadruplicate injections |
| Valve Count | 13 |
| Valve Material | High-borosilicate glass with precision lapped plug-and-body |
| Vacuum Grease | Dow Corning high-performance vacuum grease (–40°C to 200°C, low vapor pressure, chemical resistant) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LC-D Sapphire |
| Instrument Category | High-Pressure Reactor |
| Usable Volume | 500 mL |
| Vessel Material | Hastelloy C-276 |
| Optical Window Material | Sapphire |
| Maximum Operating Pressure | 10 MPa (Burst Disc: 12.5 MPa, Pressure Gauge Range: 0–16 MPa) |
| Temperature Range | Ambient to 150 °C (internal) |
| Heating Power | 1.2 kW Modular Electric Heater |
| Stirring Options | Internal Magnetic Stirring or Paddle-Type Mechanical Stirring |
| Stirring Speed | 0–1200 rpm, Continuously Adjustable |
| Control System | MRSC-LC-D V1.06 with LCD Display (Temperature, RPM, Elapsed Time), Dual-Direction Rotation, Timed Hold/Operation Mode, Audible & Visual Alarm |
| Vacuum Capability | Not Specified |
| Compliance | Designed for GLP-compliant photoelectrochemical research under elevated T/P conditions |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | LightChem Series |
| Reactor Type | Benchtop Micro High-Pressure Photochemical Reactor |
| Effective Volume | 50–500 mL |
| Construction Material | Forged 316L Stainless Steel (weld-free) |
| Operating Pressure | Up to 10 MPa (optional 20 MPa / 30 MPa variants) |
| Operating Temperature | Ambient to 250 °C |
| Heating Method | Integrated Electric Heating Module |
| Stirring | Magnetic or Mechanical Impeller, 0–1200 rpm (infinitely variable) |
| Illumination Modes | Top-, Side-, and Bottom-Irradiation Configurations |
| Optical Window | Round Sapphire Viewport (Φ20 mm or Φ40 mm) |
| Pressure Gauge | 0–16 MPa Bourdon-tube Gauge with Rupture Disc Safety System |
| Temperature Sensing | K-type Thermocouple |
| Valves | Gas Inlet/Outlet Valve, Liquid Sampling Valve, Pressure Relief Valve |
| Control System | MRSC-LightChem Intelligent Controller with Auto-Tuning for Temperature, Speed & Time |
| Safety Features | Overtemperature Alarm, Fault Indication (Audible + Visual), Dual Timer Mode (Hold-Time & Run-Time), Real-time LCD Display (Temp, RPM, Elapsed Time) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | Lightcube2.3 Lightcube |
| Construction Material | Stainless Steel |
| External Dimensions | 500 mm (L) × 500 mm (W) × 600 mm (H) |
| Operating Pressure | Low-Pressure Environment |
| Volume Class | Small-Scale Laboratory Enclosure |
| Design Type | Modular, Reconfigurable Enclosure System |
| Light Source Compatibility | Universal Mounting for Internal/External Lamps (LED, Xenon, Mercury, Halogen, UV-Vis-NIR Broadband & Monochromatic Sources) |
| Application Scope | Photocatalysis, Photochemical Synthesis, Photodegradation, Parallel Photoreaction Screening |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PCX-50C |
| Number of Reaction Stations | 9 |
| Illumination Geometry | Bottom-up vertical irradiation |
| Reactor Material | Optical-grade fused quartz base |
| Temperature Control | Integrated recirculating water chiller |
| Temp. Range | 10–80 °C (custom low-temp options available) |
| Temp. Stability | ±0.1 °C |
| Stirring Method | Synchronized magnetic suspension stirring |
| Speed Range | 0–500 rpm |
| Power Supply | 220 VAC / 50 Hz |
| Max. Current | 1 A |
| Timer Range | 1–999 min |
| Pressure Rating | 0.05 MPa |
| Standard Vial Capacity | 50 mL × 9 |
| Optional Vial Sizes | 1.5 mL, 5 mL, 10 mL |
| Vial Base Enhancement | Reflective cup for sub-50 mL vials |
| Vial Cap Options | C1 (degradation), C2 (gas-tight 3-port with auto-sampling interface) |
| Compatibility | AC1000 atmosphere controller, PLA-MAC1005 multi-gas controller, PLA-GPA1000 automated sampler |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PCX-50C Discover |
| Temperature Range | 10 °C to 80 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Positions | 9 |
| Vessel Capacities | 1.5 mL, 5 mL, 15 mL, 50 mL |
| LED Irradiance Range | 100–450 mW/cm² |
| Customizable Wavelengths | 255–770 nm (UV–Vis–NIR), including solar-spectrum Vlight mode (380–780 nm) |
| Cooling Interface | Quick-connect water-cooling port compatible with external chiller units |
| Optical Configuration | Bottom-illumination with focused collimated optics per channel |
| Optional Accessories | PLS-MAC1005 Multi-Gas Controller, GPA1000 Automated Sampler, reflective-coated reaction vials |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PCX50B Discover |
| Reaction Units | 9 |
| Reaction Volume | 50 mL (standard) |
| Light Source Power | 5 W × 9 |
| Wavelength Options | 365, 385, 420, 450, 485, 520, 535, 595, 620, 630, 760, 880, 940 nm (customizable combinations) |
| Illumination Geometry | Bottom-incident, quartz-bottom vials |
| Temperature Control | Integrated high-speed turbine air cooling, ≤ ambient + 5 °C |
| Stirring Speed | 0–500 rpm (synchronized across all positions) |
| Vial Pressure Rating | 0.05 MPa |
| Input Voltage | 220 VAC / 50 Hz |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR MFPR-I |
| Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Operating Pressure Range | −50 kPa to 0.9 MPa (gauge), i.e., 50–1000 kPa (absolute) |
| Reaction Vessel Material | Stainless Steel with Borosilicate Glass Liner |
| Effective Reaction Volume | 100 mL (total internal volume: 120 mL) |
| Automatic Gas Sampling Pressure Range | 80–900 kPa (absolute) |
| Minimum Sampling Interval | 3 min |
| Sample Volume per Injection | 100 μL |
| Gas Consumption per Sampling Cycle | ~0.5 mL |
| Magnetic Stirring Speed | 200–1500 rpm |
| Stirring Accuracy | ±1 rpm |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR MFPR-I |
| Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Operating Pressure Range | −50 kPa to 0.9 MPa (gauge), i.e., 50–1000 kPa (absolute) |
| Reaction Vessel Material | Stainless Steel with Borosilicate Glass Liner |
| Effective Reaction Volume | 100 mL (total internal volume: 120 mL) |
| Sampling Pressure Range | 80–900 kPa (absolute) |
| Minimum Sampling Interval | 3 min |
| Gas Sample Volume per Cycle | 100 μL |
| Gas Consumption per Sampling | ~0.5 mL |
| Magnetic Stirring Speed | 200–1500 rpm |
| Stirring Accuracy | ±1 rpm |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR PTCS-31 |
| Power Supply | AC 220 V, 50/60 Hz |
| Total Power | 1500 W (LED source: 900 W |
| Water cooling | 600 W) |
| Maximum Achievable Temperature | ≥500 °C (center zone, ±5 cm) |
| Reaction Tube Dimensions | Φ10 × Φ7 × 400 mm (quartz glass standard |
| Collector Tube Dimensions | Φ58 × Φ43 × 330 mm |
| Collector Tube Material | High-borosilicate glass with selective solar-absorbing coating |
| Long-term Operating Temperature Range (collector) | 5–300 °C |
| Short-term Exposure Limit | up to 500 °C (coating degradation risk above 300 °C) |
| Illumination Uniformity | >90% across irradiated surface |
| Peak Irradiance | ≥300 mW/cm² (at 1-sun equivalent, initial condition) |
| Spectral Control | Three-zone independently adjustable LED array (UV–vis–NIR) |
| Temperature Monitoring | Multi-point thermocouple interfaces along U-shaped reaction tube |
| Cooling | Integrated closed-loop water circulation system |
| Ambient Operating Conditions | 0–45 °C, non-condensing |
| Storage Conditions | −10–60 °C, 30–85% RH (drain coolant before storage below 0 °C) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-GPTR |
| Reactor Volume | 50 mL |
| Construction Material | Stainless Steel |
| Operating Pressure | Medium-Pressure (up to 0.3 MPa) |
| Heating Capability | None (base model) |
| Temperature Sensing | Internal Thermocouple for Catalyst Bulk Temperature |
| Pressure Monitoring | Integrated Pressure Sensor |
| Gas Inlet/Outlet | 6 mm OD Stainless Steel Quick-Connect Fittings |
| Catalyst Configuration | Flat-Bed Powder Placement |
| Compliance | Designed for ASTM E2539-21 (Photocatalytic Reactor Testing), ISO 22197-1 (Air Purification Performance), and GLP-aligned experimental traceability |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-GPTR Reactor |
| Reactor Volume | 25–200 mL (selectable) |
| Construction Material | Stainless Steel (316L) |
| Maximum Operating Pressure | 0.3 MPa |
| Operating Temperature Range | Ambient to 300 °C (PLR-GPTRT variant with internal heating) |
| Heating Control | 10-segment programmable PID temperature control |
| Temperature Accuracy | ±0.5 °C |
| Catalyst Bed Geometry | Flat, planar powder bed configuration |
| Gas Inlet/Outlet | Standard 6 mm OD stainless steel tubing with high-pressure quick-connect fittings |
| Pressure Monitoring | Integrated digital pressure transducer |
| Temperature Sensing | In-situ thermocouple embedded in catalyst bed |
| Vacuum Capability | Not rated for vacuum operation |
| Compliance | Designed for laboratory-scale gas–solid photo-thermal catalysis under ambient and low-pressure conditions |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-GSPR |
| Humidity Control Range | 5–95% RH (±3% RH accuracy) |
| Reactor Dimensions | 250 × 120 × 40 mm³ |
| Gas Flow Control | 4 independent mass flow channels (expandable to 8), ±1% F.S. accuracy |
| Display | 8.5-inch LED touchscreen interface |
| Temperature Monitoring Resolution | 0.01°C |
| Pressure Detection Range | 1–200 kPa (±0.2 kPa) |
| Light Window | Quartz glass, 50 × 100 mm² active area |
| Cooling | Integrated bottom-mounted water-cooled thermal control |
| Compliance | Designed in alignment with GB/T 39716–2020 for photocatalytic air purification performance testing |