Common Laboratory Equipment
Filter
Showing 1261–1290 of 4952 results
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA Small Sample Adapter |
| Sample Volume Range | 2.1–16.1 mL |
| Compatible Spindles | SC4-14, SC4-15, SC4-16, SC4-18, SC4-21, SC4-25Z, SC4-27(D), SC4-28, SC4-29, SC4-31, SC4-34 |
| Shear Rate Range | 0.22–1.32 s⁻¹ (spindle-dependent) |
| Compatible Instruments | DVNext, DV2T, DV3T, DV1, DV2, DV3, LV/ RV/ HA/ HB series digital viscometers and rheometers |
| Compliance | Designed for ASTM D2196, ISO 2555, USP <911>, and GLP-compliant viscosity testing workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TC Series |
| Instrument Type | Constant Temperature Bath |
| Circulation Function | Internal & External Circulation |
| Temperature Control Mode | Heating/Refrigeration Type |
| Bath Volume | 6–10 L |
| Temperature Range | −20 °C to 200 °C |
| Temperature Stability | ±0.01 °C |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Controller Options | AP (touchscreen), SD (LCD scroll), MX (basic LCD) |
| Bath Types | Refrigerated (TC-650/TC-550) and Tap-Water-Cooled (TC-250/TC-150) |
| Reservoir Capacity | 6 L (TC-150), 10 L (TC-250), 7 L (TC-550/TC-650) |
| Temperature Range | −20 °C to +200 °C (refrigerated models) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Pump Configuration | Variable-speed (AP), dual-speed (SD), single-speed (MX) |
| Max Flow Rate | 12–16 L/min |
| Internal Work Area (D×W×H, in) | 4.5×4.0×6.0 (TC-150) to 6.18×5.59×5.0 (TC-550/TC-650) |
| Compliance | Designed for integration with Brookfield rheometers (DV2T/DV3T/DVNext), cone-plate viscometers (Wells-Brookfield), R/S-CC & R/S-CPS rheometers, SSA, ULA, and DIN adapters |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-150 |
| Temperature Range (MX) | Ambient +10°C to 135°C |
| Temperature Range (SD/AP) | Ambient +10°C to 150°C |
| Temperature Stability (MX) | ±0.07°C |
| Temperature Stability (SD) | ±0.04°C |
| Temperature Stability (AP) | ±0.01°C |
| Controller Options | MX (basic digital), SD (dual-speed pump, PC-controllable via Rheocalc), AP (touchscreen, programmable, multi-language UI, variable-speed pump) |
| Pump Type | Single-speed (MX), Dual-speed (SD), Variable-speed (AP) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-250 |
| Temperature Range | –20 °C to +150 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Controller Options | AP (touchscreen, programmable, multi-language), SD (dual-speed pump, Rheocalc-compatible), MX (basic digital display, single-speed pump) |
| Pump Type | Variable-speed (AP), dual-speed (SD), fixed-speed (MX) |
| Software Integration | Compatible with Brookfield Rheocalc v3.0+ for remote programming and data logging |
| Temperature Range | -45 °C to +200 °C |
|---|---|
| Stability | ±0.05 °C (±0.01 °C with programmable controller) |
| Accuracy | ±0.5 °C |
| Bath Capacity | 6 L or 13 L |
| Control Options | Digital or Programmable |
| Temperature Units | °C / °F selectable |
| Display | Multilingual LCD |
| Software Integration | Compatible with Brookfield PC software for remote control and logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-550 |
| Temperature Range (MX) | –20 °C to +135 °C |
| Temperature Range (AP) | –20 °C to +200 °C |
| Temperature Range (SD) | –20 °C to +170 °C |
| Temperature Stability (MX) | ±0.07 °C |
| Temperature Stability (AP) | ±0.01 °C |
| Temperature Stability (SD) | ±0.04 °C |
| Control Interface | MX — large-character LCD |
| Pump Configuration | MX — single-speed pump |
| External Circulation | Yes |
| Max Internal Bath Volume Capacity | 600 mL (standard beaker compatibility) |
| Software Integration | Compatible with RheocalcT v3.0+ for remote parameter setting, real-time monitoring, and GLP-compliant data logging |
| Brand | Brookfield |
|---|---|
| Origin | Germany |
| Model | TC-650 |
| Temperature Range (TC-650AP) | –20 °C to +200 °C |
| Temperature Range (TC-650SD) | –20 °C to +170 °C |
| Temperature Range (TC-650MX) | –20 °C to +135 °C |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Bath Capacity | 7.0 L |
| Pump Flow Rate | 16 L/min (AP), 11 L/min (SD), 12 L/min (MX) |
| Pump Type | Adjustable-speed (AP), 2-stage (SD), 1-stage (MX) |
| Internal Dimensions (W×D×H) | 157 × 142 × 127 mm |
| External Dimensions (W×D×H) | 540 × 220 × 617 mm (AP/SD), 540 × 220 × 645 mm (MX) |
| Weight | 45 kg (AP/SD), 42 kg (MX) |
| Power Supply | Voltage and frequency specified at order |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-650 |
| Temperature Range | –20 °C to +200 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Bath Capacity | 7 L |
| Max Vessel Size | 600 mL beaker compatible |
| Control Type | Microprocessor-based SD, AP, or MX digital controller |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, UL-listed components |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Thermosel |
| Temperature Range | Up to 300 °C |
| Control Mode | Programmable (1–10 setpoints) |
| Compatibility | DV Series, DVNext, and Rheometers with analog/RS-232 interface |
| Sample Volume | 7–13 mL (depending on spindle & cup configuration) |
| Output Signal | 0–4 VDC (chart recorder), RS-232 (digital communication) |
| Spindle Support | SC4 series (e.g., SC4-18, SC4-27, SC4-29), HT-DIN-81, and other Brookfield geometry spindles |
| Shear Rate Range | 0.25–116.8 s⁻¹ (dependent on spindle, speed, and geometry) |
| Reusable Vessel | Stainless steel sample holder included |
| Disposable Cups | Aluminum single-use cups (e.g., SC4-27D-100 pack available) |
| Optional Accessories | SC4-DSY adapter, HT-106 cable (for RheocalcT QC), DVP-141 cable (for DVNext integration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | ULA |
| Viscosity Range (with compatible viscometers) | 1.0–2,000 cP (mPa·s) |
| Compatible Instruments | LVT, DV-I/II/III/Next series (LV, RV, HA, HB spindles) |
| Sample Volume | 16 mL |
| Geometry | Cylindrical cup-and-rotor system |
| Material | Stainless steel (cup, rotor, mounting hardware) |
| Optional Disposable Component | Low-density polyethylene (LDPE) bottom cap |
| Brand | Bruker |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | minispec Automation |
| Pricing | Upon Request |
| Brand | BAYE SMART |
|---|---|
| Origin | Shanghai, China |
| Model | BS280CD |
| External Dimensions (L×W×D) | 900 × 710 × 845 mm |
| Cabinet Material | Black Explosion-Proof Glass + Brushed Stainless Steel |
| Chamber Material | SUS 316L Mirror-Finish Stainless Steel |
| Chamber Welding | Laser-Welded |
| Surface Roughness | Ra = 0.2 µm (large-area), Ra = 0.4 µm (small-area) |
| Capacity | 280 × 25 mL Volumetric Flasks per Cycle |
| Basket Configuration | 2 Adjustable Layers, Modular & Interchangeable |
| Loading Flexibility | Optimized for Partial Loads |
| Cleaning Method | High-Pressure Spray Wash |
| Control System | Microprocessor-Based with Intelligent Touchscreen Interface |
| Circulation Pump | Variable-Speed, Max Flow Rate 600 L/min |
| Reagent Storage Compartment | Integrated |
| Conductivity Monitoring | Real-Time Onboard Sensor |
| Full Process Data Logging | Timestamped, Audit-Trail Enabled |
| IoT Connectivity | Ethernet/Wi-Fi Enabled for Remote Monitoring & Diagnostics |
| Compliance | EN ISO 15883-1:2009, EN ISO 15883-2:2009, FDA 21 CFR Part 11, Chinese Pharmaceutical GMP Validation Guidelines (2003), China Pharmaceutical Industry EHS Guidelines (2020) |
| Brand | Acmer |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Peristaltic Pump |
| Model | BT-100D |
| Flow Rate Range | 0.00013–560 mL/min |
| Speed | 150 rpm |
| Control Interface | RS485/USB (configurable address, baud rate 1200–9600 bps) |
| External Control | 5–24 V TTL-level start/stop signal |
| Status Outputs | Run/Stop, Direction, Alarm |
| Leak Detection | Optional visual and audible alarm |
| Calibration Modes | Volumetric and flow-based |
| Density Compensation | Supported for mass-based dispensing |
| Real-time Adjustment | On-the-fly volume/flow fine-tuning during operation |
| Pause Function | Supported in both distribution and transfer modes |
| Display Guidance | Dynamic range validation for user-defined parameters |
| Brand | Acmer |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Peristaltic Pump |
| Model | BT-300D |
| Flow Rate Range | 0.0063–1730 mL/min |
| Speed | 400 rpm |
| Control Interface | External TTL/DC (5–24 V) |
| Alarm Output | Visual & Audible Leak Detection (Optional) |
| Unit Mode | Volumetric (mL, µL) or Gravimetric (g, mg) via Density Input |
| Operation Modes | Dispensing, Transfer, Continuous, Timed, Volume-Based |
| Calibration | Multi-point Flow/Liquid Volume Calibration |
| Real-time Adjustment | Flow rate and dispense volume adjustable during operation |
| Pause Function | Supported during dispensing or transfer |
| Status Outputs | Run/Stop, Direction, Fault Alarm |
| Brand | Acmer |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Peristaltic Pump |
| Model | BT-600D |
| Flow Rate Range | 0.0063–2600 mL/min |
| Maximum Speed | 600 rpm |
| Control Interface | External TTL/DC (5–24 V), Digital Status Outputs (Start/Stop, Direction, Alarm) |
| Calibration Options | Volumetric, Gravimetric, and Flow-Based |
| Leak Detection | Optional Visual/Audible Alert |
| Operating Modes | Distribution, Continuous Transfer, Timed Dispense, Volume-Based Dispense |
| Real-Time Adjustment | On-the-fly flow rate and dispense volume modulation |
| Unit Flexibility | Volume (mL, µL) or Mass (g) input with density compensation |
| Parameter Guidance | Dynamic range validation feedback during setup |
| Pause Functionality | Full operational pause/resume during active dispensing or transfer |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Solid-Liquid Extraction System |
| Model | E-914 |
| Temperature Range | 50–200 °C |
| Pressure Range | 50–150 bar |
| Extraction Cell Volumes | 40, 60, 80, 120 mL |
| Extraction Time per Batch | 20–40 min |
| Sample Capacity | 4 positions |
| Dimensions (W × D × H) | 670 × 725 × 500 mm |
| Nitrogen Supply | 5–10 bar |
| Solvent Mixer | 4-port |
| Pump Flow Rate | 50 mL/min |
| Brand | Buehler |
|---|---|
| Origin | USA |
| Model | AutoMet 250 Pro |
| Motor Power | 1 hp (0.75 kW) |
| Maximum Sample Diameter | 40 mm (1.5 in) |
| Control Interface | Full-color LCD touchscreen |
| Sample Mounting | Apex S and magnetic disc system |
| Diamond Suspension Delivery | Up to 5 programmable Burst dispensers |
| Automation Capability | Multi-step method programming, Z-axis material removal mode |
| Cleaning | One-touch auto-clean function |
| Fixture Compatibility | Medium- and large-size sample holders |
| Compliance | Designed for GLP/GMP-aligned metallurgical lab workflows |
| Brand | Buehler |
|---|---|
| Origin | USA |
| Model | SimpliMet 4000 |
| Type | Automatic Hot Mounting Press |
| Mounting Force Range | 1000–4400 psi (70–300 bar) |
| Preload Pressure | 350 psi (24 bar) |
| Heating Temperature Range | 50°C–220°C (120°F–420°F), adjustable in 5°C (10°F) increments |
| Heating Time | 1–20 min, adjustable in 10-sec increments |
| Cooling Mode | Manual (1–30 min) or Smart Cool™ automatic cooling to 40°C |
| Mold Sizes | 25 mm, 30 mm, 40 mm, 50 mm (1", 1.25", 1.5") |
| Heating Power | 1500 W @ 115 VAC / 1900 W @ 230 VAC |
| Dimensions (W × D × H, locked) | 311 mm × 540 mm × 498 mm |
| Weight | 54 kg |
| Compliance | CE, PSE, RoHS, WEEE |
| Max Noise Level | 62 dB(A) at 1 m (lid open, piston actuating) |
| Operating Environment | 5–40°C, 30–90% RH non-condensing |
| Input Voltage/Frequency | 85–264 VAC, 50/60 Hz, single-phase |
| Water Inlet/Outlet | 1/4" OD inlet, 1/4" ID × 1/2" OD drain & outlet tubing |
| Brand | 1 mK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Buzz-Mac |
| Price | USD 1 (FOB) |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GA-SPAKv |
| Dimensions | 18.8 × 3.35 × 5.4 cm |
| Weight | 175 g |
| Operating Temperature | –20 to +50 °C (North American mode) |
| Relative Humidity | 5–95% RH (non-condensing) |
| Sampling Flow Rate | 300 mL/min (typical) |
| Maximum Sampling Distance | 15.2 m (50 ft) |
| Sampling Delay | 3 s per 0.3 m (1 ft) |
| Power Source | Two AA alkaline or NiMH rechargeable batteries (up to 30 h runtime) |
| Inlet Connection | 1/8″ (3.2 mm) barb for flexible tubing |
| Audible/Visual Alarms | 90 dB sounder |
| Compliance | Designed for use with BW Technologies single- and multi-gas detectors in accordance with OSHA 1910.146, CSA Z1000, and ATEX/IECEx-certified accessories (when paired with certified gas monitors) |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-75M |
| Instrument Type | Benchtop |
| Max Temperature | 135 °C |
| Operating Pressure | 0.22 MPa (Design: 0.25 MPa) |
| Chamber Dimensions | Ø400 mm × 700 mm |
| External Dimensions | 750 mm × 800 mm × 1080 mm |
| Chamber Volume | 75 L |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | TTs625 |
| Max Temperature | 650 °C |
| Heating Method | Direct infrared radiation onto digestion tubes |
| Rated Power | 2000 W |
| Voltage | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 636 × 354 × 740 mm |
| Weight | 21 kg |
| Digestion Tube Capacity | 6 × 250 mL (up to 800 mL with compatible racks) |
| Programmable Steps | Up to 40 segments per method, 99 methods storable |
| Tube Volume Range | 100–800 mL |
| Compliance | CE-marked, designed for GLP/GMP-aligned laboratories |
| Brand | Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PG-2 / PG-2A |
| Dimensions (L×W×H) | PG-2: 810 × 400 × 920 mm |
| PG-2A | 810 × 400 × 350 mm |
| Number of Polishing Discs | 2 |
| Disc Diameter | 200 mm |
| Rotational Speed | 900 rpm (adjustable to 1400 rpm) |
| Motor | YS7116, 0.2 kW |
| Power Supply | 380 V, 50 Hz |
| Weight | PG-2: 26 kg |
| PG-2A | 23 kg |
| Brand | Caikon Optical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | QG-5 |
| Instrument Type | Metallographic Cutting Machine |
| Cutting Method | Manual, Y-axis Handwheel Feed |
| Max Cutting Cross-section | 100 × 100 mm |
| Grinding Wheel Specification | Φ350 × 2.5 × Φ32 mm |
| Spindle Speed | 2800 rpm |
| Motor Power | 4 kW |
| Cutting Table Dimensions | 195 × 180 mm |
| Quick-Action Fixture | Yes |
| Input Power Supply | 380 V, 50 Hz |
| Machine Dimensions (W×D×H) | 700 × 940 × 1300 mm |
| Net Weight | 190 kg |
| Integrated Coolant Tank Capacity | 32 L |
| Circulating Pump Power | 90 W |
| Pump Flow Rate | 25 L/min |
| Pump Voltage | 380 V, 50 Hz |
| Tank Dimensions | 480 × 320 × 460 mm |
| Tank Weight | 14 kg |
| Construction Materials | Stainless steel clamping jaws, worktable surface, and inner shroud |
| Lighting | Integrated LED illumination |
| Viewing Window | Dual-side transparent acrylic panels |
| Noise Level | Low-noise, waterproof motor |
| Safety Design | Fully enclosed dual-shell housing with interlocked guard doors |
| Brand | Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | YMP-2C |
| Price | USD 920 (approx.) |
| Dimensions (L×W×D) | 810 × 750 × 350 mm |
| Weight | 51 kg |
| Number of Grinding/Polishing Plates | 2 |
| Plate Diameter | 230 mm |
| Speed Range | 50–1500 rpm (infinitely variable) |
| Motor Power | 350 W |
| Input Voltage/Frequency | 220 V, 50 Hz |
| Control Interface | LED digital display with membrane keypad |
| Cooling System | Integrated water supply & drainage with adjustable flow |
| Bearing Protection | Sealed main shaft design for extended service life |
| Structural Material | Molded ABS housing with reinforced base plate |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CBS-B |
| Price | USD 1,350 (FOB Shanghai) |
| Brand | CEAULIGHT |
|---|---|
| Model | CEL-GPPCM |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Reaction Pressure Range | ±0.01 MPa |
| Maximum Operating Temperature | ≤800 °C |
| Catalyst Loading Capacity | 0.1 mg–100 mg |
| Gas Inlet Channels | 3 (expandable to 4) |
| Liquid Injection Port | 1 dedicated interface |
| Flow Control Accuracy | ±1% FS |
| Pressure Display Resolution | ±0.01 MPa |
| Temperature Control Accuracy | ±1 °C |
| Temperature Display Resolution | ±0.1 °C |
| Reactor Material | Fused Quartz |
| Reactor Dimensions | Compatible with standard quartz tube configurations (ID/OD specified per configuration) |
| System Footprint | 400 mm (W) × 700 mm (H) × 700 mm (D) |
| Safety Features | Dual-stage temperature & pressure alarm with automatic interlock shutdown |
| Data Logging | Real-time acquisition, timestamped storage, CSV export capability |
| Compliance Framework | Designed for GLP-aligned operation |
| Brand | CEA-Light (CEL) |
|---|---|
| Model | HT5 |
| Type | Dual-Compartment Photoelectrochemical Reactor |
| Capacity | 100 mL (total, 50 mL per chamber) |
| Operating Pressure | Low-pressure / Ambient Pressure |
| Vacuum Capability | Atmospheric (no active vacuum system) |
| Window Material | Standard Quartz (25 mm diameter, ≥185 nm UV transmission) |
| Optional Windows | CaF₂ (down to 125 nm), KBr (IR-transmissive) |
| Electrode Compatibility | External electrodes with 6 mm outer diameter |
| Membrane Integration | Compatible with ion-exchange membranes (e.g., Nafion™) |
| Connection | DIN 25/35 ISO-K flange interface |
| Construction Material | Borosilicate glass body with PTFE-sealed stainless steel flanges |
| Application Domain | In situ photoelectrochemical (PEC) characterization, dual-compartment redox coupling, controlled potential electrolysis under illumination |
| Brand | CELLINK |
|---|---|
| Origin | Sweden |
| Model | BIO MDX |
| Maximum Microplate Capacity | 27 standard microplates or 140 microscope slides |
| Droplet Volume Resolution (with sciDROP PICO) | <200 pL |
| Nozzle Temperature Range | 0–350 °C |
| Build Platform Temperature Range | −10–80 °C |
| Ambient Control | HEPA-filtered laminar airflow, programmable humidity, temperature, and dew point |
| Positioning Accuracy | ≤1 µm |