| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model Series | Optima L-100XP, L-80XP, L-100K, L-90K |
| Max RCF | 802,400 × g (L-100XP/L-100K), 602,000 × g (L-80XP), 694,000 × g (L-90K) |
| Max Speed | 100,000 rpm (L-100XP/L-100K), 80,000 rpm (L-80XP), 90,000 rpm (L-90K) |
| Temperature Control Accuracy | ±0.3 °C (L-100XP), ±0.5 °C (L-80XP/L-100K/L-90K) |
| Software | eXPert Centrifuge Software (full version) |
| Vacuum System | Oil-free, dehydration-based |
| Motor Drive | Hermetically sealed vacuum drive |
| Safety | Dynamic rotor inertia monitoring, automatic rotor recognition, HEPA-filtered exhaust |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Optima MAX-TL |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Ultracentrifuge (>30,000 rpm) |
| Function | General-purpose ultracentrifugation |
| Configuration | Horizontal rotor compatible |
| Separation Level | Cellular and bacterial subfractionation |
| Maximum Capacity | 40.8 mL |
| Maximum Speed | 120,000 rpm |
| Maximum RCF | 657,000 × g |
| Dimensions (W × D × H) | 73.9 × 61.7 × 39.4 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Desktop Ultracentrifuge |
| Speed Range | Up to 120,000 rpm |
| Maximum RCF | 657,400 × g |
| Maximum Capacity | 8 × 5.1 mL |
| Refrigeration | Yes (Cryogenic Cooling) |
| Rotor Compatibility | Full backward compatibility with Optima TL-series rotors (fixed-angle, swinging-bucket, vertical, near-vertical) |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Safety Certification | BioSafe-compliant design |
| Display | Full-color LCD touchscreen with multilingual UI (including Chinese and English) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Optima MAX-TL |
| Instrument Type | Tabletop Centrifuge |
| Speed Range | Up to 120,000 rpm |
| Max RCF | 657,000 × g |
| Max Capacity | 6 × 85 mL |
| Dimensions (W×D×H) | 61.7 × 73.9 × 34.5 cm |
| Rotors Compatibility | Full interchangeability with Optima TL series rotors (fixed-angle, swinging-bucket, vertical, near-vertical) |
| Safety Features | Integrated HEPA filtration, biosafety-certified rotors and tubes |
| Display | Touchscreen LCD with bilingual (English/Chinese) UI support |
| Application Scope | Subcellular fractionation, virus purification, lipoprotein isolation, macromolecular sedimentation |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Benchtop Ultracentrifuge |
| Speed Range | Up to 150,000 rpm |
| Max RCF | 1,019,400 × g |
| Max Capacity | 194.4 mL |
| Sample Volume Range | 0.175–194.4 mL |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Compliance | Designed for GLP/GMP environments with electronic audit trail support |
| Rotor Types | Fixed-angle, swinging-bucket, vertical, near-vertical |
| Safety | Integrated biosafety features including optional HEPA aerosol containment |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Optima MAX-XP |
| Centrifuge Type | Benchtop Ultracentrifuge |
| Maximum Speed | 150,000 rpm |
| Maximum RCF | 1,019,000 × g |
| Maximum Capacity | 6 × 32.4 mL |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Sample Volume Range | 0.175–194 mL |
| Operating Temperature Range | 0–40 °C |
| Noise Level | <55 dBA (typical at 150,000 rpm) |
| Interface Language | English / Chinese selectable |
| Security Compliance | User authentication, electronic audit trail, FDA 21 CFR Part 11–ready software architecture |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Type | Floor-standing ultracentrifuge |
| Speed Range | 100,000 / 90,000 rpm |
| Max RCF | 802,400 / 694,000 × g |
| Max Capacity | 1.5 L |
| Temperature Range | 0–40 °C (1 °C increment) |
| Temp Accuracy | ±0.5 °C |
| Acceleration Profiles | 10 selectable |
| Deceleration Profiles | 11 selectable (including coast-down) |
| Speed Control Resolution | ±2.00 rpm (≥1,000 rpm) |
| Runtime | up to 999 h 59 min |
| Noise Level | <51 dBA |
| Dimensions | 94 × 68.1 × 125.7 cm |
| Compliance | FDA 21 CFR Part 11 ready, ISO 13485 certified, GLP/GMP-compatible design |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Drive System | Refrigerated Brushless Induction Motor |
| Temperature Control | 0–40 °C (±0.5 °C) |
| Power Supply | 180–264 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Acoustic Noise Level | <51 dBA |
| Standby Power Consumption | <60 W |
| Compliance | ISO 13485, IEC 61010-1, FDA 21 CFR Part 11 (software-enabled audit trail), GLP/GMP-ready configuration options |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Optima XPN |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Class | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Primary Function | Analytical & Preparative Ultracentrifugation |
| Typical Configuration | Fixed-angle Rotor System |
| Separation Target | Subcellular Organelles, Viruses, Macromolecular Complexes |
| Maximum Capacity | 1.5 L |
| Max Speed Options | 100,000 / 90,000 / 80,000 rpm |
| Max RCF | 802,000 × g / 694,000 × g / 548,300 × g |
| Dimensions (W × D × H) | 94 × 68.1 × 125.7 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Floor-standing ultracentrifuge |
| Speed Range | 100,000 / 90,000 / 80,000 rpm |
| Maximum RCF | 802,000 / 694,000 / 548,300 × g |
| Maximum Capacity | 1.5 L |
| Rotor Compatibility | Fixed-angle, swinging-bucket, vertical, near-vertical, and zonal rotors |
| Dimensions (W × D × H) | 94 × 68.1 × 125.7 cm |
| Safety Compliance | Meets IEC 61010-1, UL 61010-1, and FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Cooling | Refrigerated (2–30 °C) |
| Display | 15-inch capacitive touchscreen |
| Voltage Range | 180–264 VAC (auto-sensing) |
| Power Consumption (standby) | <60 W |
| Noise Level | <51 dBA |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP traceability features, ISO 13485-aligned design |
| Software | eXPert Centrifuge Software v5.x |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | ProteomeLab™ XL-A/XL-I |
| Instrument Type | Floor-standing Analytical Ultracentrifuge |
| Speed Range | Up to 70,000 rpm |
| Maximum RCF | 601,000 × g |
| Dimensions | 94 × 68.1 × 125.7 cm |
| Detection Systems | UV-Vis (XL-A: 190–800 nm) or Interference Optics (XL-I) |
| Sample Capacity | Up to 21 cells simultaneously |
| Vacuum System | High-efficiency dehydration-type |
| Power Consumption | 3.4 kW/h |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Safety Features | Dynamic rotor inertia monitoring, hermetic vacuum drive, HEPA-filtered exhaust |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr B10dN / B22dN / B45dN |
| Pure Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count / Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Max. Operating Pressure | 8 bar |
| Housing Material | Polyamide (PA66-GF30) |
| Exchange Capacity (B10dN/B22dN/B45dN) | 1.2 / 2.4 / 5.5 kL @ 10 °dH hardness removal |
| Max. Flow Rate (L/h) | 300 / 500 / 800 |
| Overall Height (cm) | 68 / 112 / 125 |
| Housing Height (cm) | 55 / 98 / 110 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr B5/B10 |
| Pricing Range | USD 720 – 7,200 (FOB) |
| Water Grade | ASTM Type I Ultra-Pure Water |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 10 ppb |
| Microbial Count / Endotoxins | < 0.001 EU/mL |
| Particulates (>0.1 µm) | < 1 particle/mL |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr Coated Stainless Steel Mixed-Bed Ion Exchange Cartridge System |
| Purity Grade | ASTM Type I Ultra-Pure Water |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count / Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Max. Flow Rate | 500 L/h |
| Operating Pressure | Up to 10 bar (permanent) |
| Conductivity Monitoring Threshold | 20 µS/cm (configurable limit switch) |
| Enclosure Material | V4A (1.4404/1.4435) stainless steel with vulcanized polyurethane coating |
| Structural Protection | Vulcanized elastomeric collars at top/bottom |
| Integrated Conductivity Sensor | Pre-installed, supports local display and remote signal output (4–20 mA or digital interface) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr CUS 2 |
| Pricing | Available Upon Request |
| Material | Borosilicate Glass (Compliant with ISO 9377-2) |
| Configuration | Dual-Column Parallel Setup |
| Weight | ~3 kg |
| Dimensions (W×D×H) | ~23 × 27 × 50 cm |
| Included Components | Support Stand, Two 100 mL Graduated Collection Flasks, Two Purification Columns (Part No. 2804800203), Two Dropping Funnels, Two Kuderna-Danish Concentration Vessels |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Behr Diaphragm Pump |
| Price Range | USD 70–280 (est.) |
| Instrument Type | Diaphragm Vacuum Pump |
| Product Type | Oil-Free Pump |
| Max Flow Rate | 300–500 L/h |
| Max Vacuum Level | 3.1–3.3 mbar (abs) |
| Voltage | 220–240 V |
| Frequency | 50 Hz |
| Power Consumption | 48 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr E28/E40d |
| Output Water Grade | Type I Ultra-Pure Water |
| Resistivity | 18.2 MΩ·cm |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Max. Operating Pressure | 10 bar (E28d/E40d), 8 bar (E40dA) |
| Exchange Capacity (at 10 °dH) | 2,800 L (E28), 4,000 L (E40d) |
| Max. Flow Rate | 500 L/h (E28), 700 L/h (E40d) |
| Housing Diameter | 24 cm |
| Overall Height | 74 cm (E28), 84 cm (E40d) |
| Cartridge Height | 60 cm (E28), 70 cm (E40d) |
| Conductivity Alarm Threshold | 20 µS/cm |
| Material | ASTM A276 Type 316L (V4A) stainless steel |
| Integrated Conductivity Monitoring | Yes |
| Optional Features | Solenoid Valve + Limit Switch (Model “A”), Spare Cartridge Kit (Model “Z”) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ET2 |
| Price | Upon Request |
| Dimensions (W×H×L) | 14.0 × 10.0 × 27.0 cm (unit only) |
| Weight | ~17 kg |
| Voltage | 220 V / 50 Hz |
| Max. Power Output | 2200 W |
| Load Type | Resistive (Ohmic), 4-pole threaded connector |
| Sensor | PT100, 3-wire configuration, via 3-pole screw terminal |
| Control Principle | PID with anti-drift compensation |
| Temp. Range | 20–450 °C |
| Temp. Accuracy | ±1 K |
| Time Range | 1–999 min (±1 min), continuous heating mode enabled |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr EX1000 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr HB4 / HB6 Multi-Sample Heating Block |
| Pricing | Available Upon Request |
| Dimensions (W×H×L) | HB4 ≈ 53 × 74 × 32 cm |
| Weight | HB4 ≈ 15.1 kg |
| Rated Voltage | 230 V~, 50/60 Hz |
| Rated Power | HB4 = 1440 W |
| Independent Temperature Control per Position | Yes |
| Sample Port Diameter | 94 mm |
| Optional Support Stand | HBS-4 (for HB4), HBS-6 (for HB6) |
| Accessories Part Numbers | 80 48 00506 (HB4), 80 48 00507 (HB6), 80 48 00508 (HBS-4), 80 48 00509 (HBS-6) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr IRF10 |
| Price Range | USD 1,400 – 7,200 |
| Instrument Type | Box-Type Furnace |
| Maximum Temperature | 1150 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 1.5 kW |
| Heating Rate (to 1000 °C) | ≤10 s |
| Heating Method | Elliptical Reflector Infrared Radiation with Gold-Coated Interior |
| Internal Chamber Dimensions | 350 × 325 × 410 mm |
| Quartz Tube Outer Diameter Options | 18–20 mm, 22–24 mm, 26–28 mm |
| Infrared Heating Zone Length | 200 mm |
| Communication Interface | RS-232 (D-Sub 9-pin female) |
| Cooling Method | Passive Heat-Pipe-Assisted Rapid Quenching |
| Gas Inlets | Dual Mass Flow Controlled (O₂ + inert gas) |
| Thermocouple | Type K (NiCr–Ni), Mounted on Outer Wall of Quartz Combustion Tube |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KEX Compact Soxhlet Extraction System |
| Pricing | Available Upon Request |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Current | 3 A / 6 A |
| Power Rating | 450 W |
| Weight | ~7.5 kg |
| Dimensions (W×D×H) | ~23 × 33 × 71.5 cm (KEX 30) / ~23 × 33 × 80 cm (KEX 100) |
| Extraction Vessel Capacity | 30–500 mL |
| Sample Throughput | 1 sample per unit (compact configuration) |
| Condenser Interface | Standard threaded joint (compatible with Weibull/Stoldt acid hydrolysis units) |
| Drain Valve | Integrated piston valve for post-extraction solvent transfer |
| Cooling Requirement | Compatible with UK 12/400 recirculating chiller (380 W) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr KOSTA 2 |
| Price Range | USD 420–1,400 (FOB) |
| Heating Method | Dry-Block Heating |
| Temperature Range | Ambient to 99 °C |
| Temperature Stability | ±0.5 °C |
| Sample Tube Diameter Compatibility | 10–29 mm |
| Nitrogen Flow Rate | 0–15 L/min |
| Sample Positions | 2 |
| Heating Power | 150 W |
| Dimensions (W×D×H) | 23 × 27 × 50 cm |
| Weight | ~4 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Behr KSMA |
| Pricing | Upon Request |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Current | 3 A / 6 A |
| Power Consumption | 450 W |
| Weight | approx. 6 kg |
| Dimensions (W × D × H) | approx. 230 × 330 × 800 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Behr Metal Guarded Heating Mantle |
| Pricing | Upon Request |
| KP1 | Ø90 mm, 500 W, 230 V |
| KP2 | Ø145 mm, 1100 W, 230 V |
| Weight (KP1) | ~1.2 kg |
| Weight (KP2) | ~1.3 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr PLP Series |
| Pricing | Available Upon Request |
| Motor | AC 220 V / 50 Hz (also available in 115 V / 60 Hz variants) |
| Roller Configuration | Dual-roller compression with four guide rollers |
| Flow Range | PLP 330: 0.4–25 L/h |
| PLP 66 | 1.0–45 L/h |
| PLP 3304 | 4.0–245 L/h |
| PLP 1000 | 15–605 L/h |
| Tubing Replacement | Tool-free, rapid exchange design |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr R-Series Multi-Sample Soxhlet Extraction System |
| Pricing | Available Upon Request |
| Configuration Options | 4-position & 6-position variants |
| Solvent Reservoir Capacity | 100 mL, 250 mL, or 300 mL per extraction chamber |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Power Consumption | 1140 W (4-position), 2160 W (6-position) |
| Current Rating | 8 A / 16 A (230 V), 10 A / 20 A (115 V) |
| Net Weight | ~15.1 kg (4-position), ~19.8 kg (6-position) |
| Dimensions (W×D×H) | ~530 × 320 × 740 mm (4-position), ~760 × 320 × 740 mm (6-position) |
| Condenser Cooling | Dual-path分流 water jacket with independent flow control per channel |
| Heating Control | Individual PID-regulated heating blocks per sample position |
| Safety Features | Overtemperature cutoff, solvent vapor containment design, drip-resistant condenser interface |
| Compliance | Designed in accordance with DIN EN ISO 14555 and AOAC Official Method 991.36 for fat determination |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr SMA-ARB |
| Instrument Type | Electric Heating Digestion System |
| Voltage | 230 V~ |
| Configurations | 6-position or 12-position |
| Heating Range (SAM unit) | 20–300 °C |
| External Controller (ET2) Range | 20–450 °C |
| Timer Range | 10–999 min or continuous mode |
| Digestion Vessels | SR2 round-bottom tubes, 250 mL, NS29/22 standard taper, PVDF gaskets |
| Condensers | SFK50 spherical reflux condensers (6 per 12-position unit) |
| Absorption Vessels | AS1 scrubbing containers |
| Support Frame | Stainless steel SG/B insert frame with integrated coolant distributor and condenser support |
| Dimensions (W × D × H) | approx. 45 × 65 × 100 cm |
| Weight | ~30 kg (SMA-ARB 6), ~39 kg (SMA-ARB 12) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr SMA-ARM |
| Instrument Type | Electric Heating Digestion System |
| Voltage | 230 V~ |
| Part Numbers | 80 48 80011 (6-position), 80 48 80012 (12-position) |
| Weight | ~35 kg (6-pos), ~44 kg (12-pos) |
| Dimensions (W × D × H) | ~45 × 65 × 100 cm |
| Temperature Range | 20–399 °C |
| Time Setting | 1–999 min |
| Programmable Steps | Up to 10 temperature/time ramps |
| Controller | TRS300 external microprocessor unit (replaces ET2) |
| Sample Capacity | 6 or 12 positions |
| Accessories | PTFE-sealed glassware support frame (SG/B), transport & prep rack (TS) with integrated coolant distributor and condenser support, nitrogenous fume hood (AH) for 6/12 samples |