Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHR250A
Instrument TypeAnalytical Balance
Capacity Range200–500 g
Readability0.1 mg
Calibration MethodInternal Automatic Calibration
Maximum Capacity252 g
Accuracy±0.3 mg
Repeatability0.2 mg
Stabilization Time2 s
Sensitivity Drift±2 ppm/°C (10–30 °C)
Operating Environment5–40 °C, RH <85% non-condensing
Display Update Rate5 or 10 Hz
Counting Mode Minimum Unit0.1 mg
Sample Count Options10 / 25 / 50 / 100 pcs
% Weighing Minimum Reference Weight10.0 mg
% Display Resolution0.01% / 0.1% / 1%
InterfaceRS-232C
Software CompatibilityWinCT Data Acquisition Suite
External Calibration Weights250 g / 200 g / 100 g / 50 g
Pan DiameterØ90 mm
Draft Shield Dimensions193(W) × 262.5(D) × 84.5(H) mm
Power SupplyAC adapter (~11 VA), region-specific voltage compliance
Net Weight~3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGR200
Instrument TypeAnalytical Balance
Capacity210 g
Readability0.1 mg
CalibrationInternal Automatic Calibration with Built-in Weights + External Calibration Support (50 g / 100 g / 200 g / 250 g)
Repeatability (SD)0.1 g
Linearity Error±0.2 g
Stabilization Time2 s
Sensitivity Drift±2 ppm/°C (10–30 °C)
Operating Environment5–40 °C, RH <85% non-condensing
Display Update Rate5 or 10 Hz
Counting Mode Minimum Unit0.1 mg
Sample Count Options10 / 25 / 50 / 100 units
InterfaceRS-232C
Software CompatibilityWinCT Data Acquisition Suite
Pan DiameterØ85 mm
Draft Shield Dimensions249 × 330 × 328 mm (W×D×H)
Power SupplyAC Adapter (~11 VA), Region-Specific Input Voltage
Net Weight~6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGH120
Instrument TypeAnalytical Balance
Capacity120 g
Readability0.1 mg
Accuracy±0.2 mg
Repeatability0.1 mg
CalibrationInternal Automatic Calibration with Built-in Weights
Stabilization Time3.5 s
Linearity Error±0.2 mg
Sensitivity Drift±2 ppm/°C (10–30 °C)
Operating Environment5–40 °C, <85% RH (non-condensing)
Display Update Rate5 or 10 Hz
Weighing Unitsg, mg, oz, ct, lb, %, pcs, etc.
ConnectivityRS-232C
Software CompatibilityWinCT Data Acquisition Suite
Pan DiameterØ90 mm
Draft Shield Dimensions217(W) × 442(D) × 316(H) mm
Power SupplyAC adapter (~11 VA)
Net Weight8.2 kg