Empowering Scientific Discovery

Damotianyu Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMitsubishi Chemical
OriginJapan
ModelGT-200
Measurement Range0–14 pH, −2000 to +2000 mV, 0–20 µA
Titrant Dispensing Accuracy±0.01 mL (20 mL burette)
Resolution0.002 mL
Titration Resolution1/10000
Display5.7″ color LCD
Operating Temperature5–40 °C
Humidity≤85% RH (non-condensing)
Power Supply100–240 V AC, 100 VA
Dimensions (main unit)175 × 408 × 176 mm (W×D×H)
Weight4 kg
GLP ComplianceFull audit trail for calibration, electrode validation, titrant standardization, and user access logs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITSUBISHI CHEMICAL
OriginJapan
ModelCA-200
Measurement PrincipleCoulometric Karl Fischer Titration
Detection Range10 µg – 100 mg H₂O
AccuracyCV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10)
Electrolysis Current430 mA
Average Titration Speed2.2 mg H₂O/min (36 µg H₂O/sec)
Display5.7-inch color LCD
Data Storage20 user-defined methods × 50 sub-files each
InterfaceRS-232C (optional), USB storage port, analytical balance input
Power SupplyAC 100–120 V / 230–240 V, 50/60 Hz
Host Dimensions & Weight220 × 350 × 360 mm, ~5 kg
Stirrer Dimensions & Weight120 × 180 × 148 mm, ~1 kg
VA-200 Sample HeaterTemp. Range 70–300 °C, N₂ carrier gas flow 0.1–0.5 L/min, max. sample mass 10 g, weight ~5.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNittoseiko Analytech
OriginJapan
ModelCA-310KB
Measurement Range10 mgBr/100g – 500 gBr/100g
Relative Standard Deviation< 0.3%
Detection Resolution10 µg Br₂
Titration Accuracy±5%
Electrolysis Current430 mA (516 mA in High-Speed Mode)
Display8.4-inch color TFT touchscreen
Max. Simultaneous Channels4 (optional)
ComplianceASTM D1159, SH/T 1767, SH/T 1485.5, GB/T 11136
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNittoseiko Analytech
OriginJapan
ModelCA-310CB
Instrument TypeUniversal Coulometric Potentiometric Titrator
Measurement Range1–10,000 mg Br/100 g
Electrode Readout AccuracyRSD < 0.3%
Resolution0.1 µg Br₂
Titration Accuracy±3%
Compliance StandardsGB/T 1815–2019, SH/T 1551–2018, SH/T 0630–1996, ASTM D1492–13
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITSUBISHI CHEMICAL
OriginJapan
ModelGT-310
Instrument TypeGeneral-purpose Potentiometric Titrator
pH Range0–14
mV Range–2000 to +2000 mV
Meter Accuracy±0.2% of full scale
pH Resolution0.001 pH unit
Titration Endpoint Precision±0.3 mV
Maximum Simultaneous Modules4 titration units (potentiometric and/or Karl Fischer)
Endpoint Detection ModesFirst Derivative (Inflection Point), Fixed Potential, Pre-/Post-Intersection, V-Crosspoint, and Second Derivative
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0