Environmental Monitoring Instruments
Filter
Showing 8881–8910 of 8927 results
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZM-GC-FID NMHC CEMS |
| Pricing | Available Upon Request |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZM-WQMS-7P “Water Sentinel” |
| Pricing | Available Upon Request |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TSC-10 Temperature Chain Profiling System |
| Pricing | Available Upon Request |
| Number of Sensors | 10 |
| Operating Temperature Range | −55 °C to +80 °C |
| Accuracy | ±0.2 °C (−40 °C to +85 °C, typical), ±0.4 °C (−40 °C to +85 °C, worst-case), ±0.5 °C (−55 °C to −40 °C) |
| Max Pressure Rating | 150 PSI |
| Communication Protocol | RS-485 / MODBUS-RTU |
| Sensor Spacing | Customizable (min. 12 cm) |
| Max Chain Length | 155 m |
| Max Sensor Capacity | 150 nodes |
| Sensor Diameter | 5 cm |
| Supply Voltage | 3.3–24 V DC |
| Current Consumption | 10 mA + (N × 1 mA), where N = number of active sensors |
| Warm-up Time | 10 s |
| Minimum Sampling Interval | 10 s |
| Standard Cable Length Options | 10 m, 20 m, 50 m |
| Optional Sensor Integration | Dissolved Oxygen (DO), Conductivity |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZM-OFEMS |
| Pricing | Upon Request |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Model | HQ-6200 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Performance Colorimetry (Molybdenum Blue Method) |
| Detection Range | 0.05–5 mg/L PO₄–P and 0.5–50 mg/L PO₄–P (dual-range auto-switching) |
| Detection Limit | 0.02 mg/L PO₄–P |
| Sample Cycle Time | ≤5 minutes (from aspiration to result output) |
| Reagent Consumption | <10 µL per measurement |
| Operating Mode | Programmable single-shot, continuous, periodic, or event-triggered measurement |
| Cleaning System | Integrated automated ultrasonic + air-pulse cleaning module |
| Compliance | Designed to support ISO 15586, ASTM D515-18, and EPA Method 365.1 workflows |
| Software Interface | RS485/Modbus RTU, optional Ethernet/IP and OPC UA |
| Enclosure Rating | IP65 |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HQ-6700 Silicate Auto Analyzer |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Price Range | USD 7,000 – 70,000 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Reflectance-Transmittance Measurement System |
| Price Range | USD 7,000 – 70,000 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Welcome Light Automated Inspection System |
| Price Range | USD 7,000 – 70,000 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | DPE12 |
| Price | USD 2,100 (FOB Beijing) |
| Operating Temperature Range | −20 °C to +55 °C |
| Spectral Range | 1.5–12 µm |
| Active Area | 2 mm × 2 mm |
| Responsivity | ≥80,000 V/W (at 10 Hz, λ = 10.6 µm) |
| Detectivity (D*) | ≥3 × 10⁸ cm·√Hz/W (at 10 Hz, λ = 10.6 µm) |
| Shunt Resistance (R<sub>d</sub>) | 0.1–0.3 MΩ |
| Recommended Modulation Frequency | 10 Hz |
| Frequency Response Bandwidth | 5–100 Hz |
| Output Signal Type | Voltage |
| Bias Voltage | 3 V DC |
| Rise Time | <100 ms (typ.) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Assembly Auto-Measurement System |
| Price Range | USD 7,000 – 70,000 |
| Motion Stage Accuracy | ±0.01 mm |
| Max Test Area | 2000 mm × 1500 mm |
| Measurement Parameters | Luminance, Luminance Distribution, Chromaticity (CIE x,y & u'v'), Chromaticity Uniformity, Defect Detection (pixel-level anomaly), Antenna Resistance (4-wire Kelvin) |
| Data Traceability | Full Audit Trail with Timestamped Metadata |
| Automation | Automatic Power-on/Power-off via Relay-Controlled Socket & Motorized Connector Actuation |
| Software | Region-of-Interest (ROI) Customization, Arbitrary Shape Definition, Large-Area Image Mosaic & Photometric Calibration Integration |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Light Color Measurement and Calibration System |
| Price Range | USD 7,000 – 70,000 |
| Core Components | Integrating Sphere + Light-Tight Enclosure + Fiber-Optic Spectrometer + Dedicated Calibration Software + Host PC |
| Measurement Principle | Spectroradiometric Analysis via CCD-based Fiber-Optic Spectroscopy |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZLDM-118 |
| Price Range | USD 1,400 – 2,800 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | CH₄ (Methane), other hydrocarbons (C₁–C₄) |
| Measurement Range | 0–5% vol and 0–100% vol selectable |
| Resolution | 0.01% vol (0–5% vol range), 0.1% vol (0–100% vol range) |
| Output Interfaces | Analog (4–20 mA / 0–5 V / 0–10 V) and Digital (RS485 Modbus RTU) |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Tolerance | Unaffected by relative humidity under non-condensing conditions |
| Calibration | Factory-calibrated per customer-specified span gas |
| Compliance | GB 15322 (Combustible Gas Detectors), GB 3836.1–2000 (Explosion-Proof General Requirements), GB 3836.4–2000 (Intrinsically Safe “i” Equipment) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZLDM-126T |
| Price Range | USD 1,400 – 2,800 |
| Technology | Non-Dispersive Infrared (NDIR) |
| Measurement Principle | Absorption Spectroscopy at 4.26 µm |
| Output Signal | Analog (0–5 V / 4–20 mA) and Digital (UART/I²C) |
| Operating Temperature | −10 °C to +50 °C |
| Humidity Range | 0–95 % RH (non-condensing) |
| Accuracy | ±(30 ppm + 3 % of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | < 120 s |
| Zero Drift | < 2 ppm/month |
| Span Drift | < 2 %/year |
| Lifetime | > 15 years |
| Power Supply | 5 VDC ±5 % |
| Current Consumption | < 35 mA |
| Dimensions | 32 × 22 × 12 mm |
| Weight | ~8 g |
| Compliance | RoHS, CE (EMC/LVD), ISO 8573-1 Class 4 (for internal gas path) |
| Brand | -- |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZSCA04 |
| Quotation | Upon Request |
| Net Weight | 25 kg |
| Input Voltage | 110–230 VAC, 50–60 Hz |
| Dimensions (L×W×H) | 60 × 54 × 36 cm (lid closed) |
| Interface | USB 2.0 |
| Optical Resolution | 4800 dpi |
| Image Dimensions | 14150 × 22640 pixels (≈320 MP, ~1 GB per scan) |
| Illumination | Uniform LED-based transmitted-light system optimized for plankton contrast and shadow-free imaging |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | ZR-A03 |
| Pricing | Available Upon Request |
| Brand | Junray |
|---|---|
| Model | ZR-B02 |
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Pricing | Available Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Junray Instrument Co., Ltd. |
| Type | ZR-G01 |
| Compatible Instruments | ZR-2050 & ZR-2050A Airborne Microbial Samplers |
| Pressure Regulation | Integrated pressure-reducing valve (max inlet pressure ≤ 1.0 MPa, output flow stabilized at 100 L/min ± 5%) |
| Material | Anodized aluminum adapter body |
| Connection | Pneumatic quick-coupling interface (ISO 8573-1 Class 2 compliant) |
| Design | Modular, field-deployable assembly |
| Compliance | Designed per Annex 1 (2022) of EU GMP and USP <797> requirements for compressed gas microbiological monitoring |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-J01 |
| Pricing | Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-J02B |
| Pricing | Available Upon Request |
| Flow Rate Compatibility | 16.7 L/min, 50 L/min, 100 L/min |
| Compliance Standard | HJ 955–2018 |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ZWIN-CHL1006 |
| Application | Online Chlorophyll-a Monitoring |
| Measurement Principle | Chlorophyll Fluorescence Detection |
| Chlorophyll-a Range | 0–500 µg/L |
| Limit of Detection (LOD) | 0.01 µg/L |
| Accuracy | <5% FS |
| Resolution | 0.01 µg/L |
| Response Time | <15 s |
| Operating Temperature | 0–50 °C |
| Dimensions (Ø × L) | 34 × 225 mm |
| Housing Materials | POM + Titanium Alloy + 316L Stainless Steel |
| Ingress Protection | IP68 (1 bar) |
| Power Supply | 12–24 VDC |
| Output Interface | RS485 with Modbus RTU Protocol |
| Self-Cleaning Function | Yes |
| Light Source | High-Brightness LED |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZWIN-VOCS |
| Price Range | USD 1,400 – 7,000 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Continuous Online Analyzer |
| Typical Configuration | Total VOC (TVOC) Monitor |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ≤ ±5% FS |
| Response Time | T90 < 5 s |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | ZWIN-YC06-PLAT |
| Price Range | USD 1,400 – 7,200 (FOB) |
| Measured Pollutants | CO, CO₂, NO₂, PM₂.₅, PM₁₀ |
| Measurement Principle | Optical Scattering (PM), Electrochemical (Gases), Piezoelectric (Noise), Ultrasonic/Cup Anemometry (Wind), Capacitive (RH), Thermistor/RTD (Temp), Piezoresistive (Baro) |
| Display | 7-inch capacitive touchscreen |
| Data Transmission | 3G/4G LTE, RS485, Ethernet |
| Environmental Rating | IP65 enclosure, IP67 sensors |
| Power Options | AC220V ±10% or solar-battery hybrid (optional) |
| Compliance | GB 3095–2012, HJ 653–2013, HJ 93–2013, ISO 12103-1 (dust calibration reference), ASTM D1319 (for hydrocarbon interference mitigation in CO/NO₂ sensing) |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZWIN-YCB06 |
| Instrument Type | Portable |
| Measurement Principle | Beta-Ray Absorption |
| Measured Parameter | PM10 |
| Measurement Range | (0–1000) µg/m³ or (0–10000) µg/m³ (selectable) |
| Sampling Flow Rate | 16.7 L/min |
| Minimum Detection Limit | ≤2 µg/cm² |
| Filter Spot Area | 1.68 cm² |
| Spot Center-to-Center Spacing | ~18.84 mm ± 0.5 mm |
| Full-Scale Loading | 1.5 mg/cm² |
| Resolution | ±2% |
| Max. Permissible Error | ≤±20% |
| Sampling Tube Material | Stainless Steel (Note: “Drill alloy” in source is nonstandard |
| Sampling Tube Length | 500 cm |
| Operating Temperature | 0–300 °C |
| Relative Humidity | ≤80% RH |
| Flue Gas Pressure Range | −10 to +10 kPa |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Detector | Scintillation Detector with Photomultiplier Tube |
| Data Update Interval | 5 s |
| Data Storage | Onboard non-volatile memory |
| Repeatability | ≤±2% |
| Flow Accuracy | ±2% (at nominal 16.7 L/min) |
| Timing Drift | <10 s per 24 h |
| Acoustic Noise | ≤65 dB(A) |
| System Leak Rate | <200 Pa pressure decay within 1 min after sealing at −5 kPa vacuum |
| Ambient Operating Conditions | Indoor/outdoor portable deployment |
| Brand | ZWINsoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZWINsoft1.0 |
| Pricing | Upon Request |
| Brand | ZWINSOFT |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Z WIN-AQMS-PLAT |
| Pollutant Parameters | SO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀ |
| Compliance Framework | Designed for integration with China’s National Environmental Monitoring Network (CNEMN), aligned with HJ 653–2013, HJ 654–2013, and GB 3095–2012 standards |
| Brand | ZwinSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ZWIN-1.0 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Measurement Principle | Integrated Sensor Network Data Aggregation & GIS-Based Spatial Analytics |
| Measured Parameters | PM₂.₅, PM₁₀, TSP, VOCs, NO₂, SO₂, NH₃, wind speed/direction, humidity, temperature (configurable per deployment) |
| Measurement Range | 0–1,000 µg/m³ (PM), 0–50 ppm (gases) |
| Sampling Interval | 1 minute (configurable) |
| Sampling Flow Rate | 1.0 L/min ±5% |
| LOD (PM) | 1 µg/m³ |
| Flow Stability | ±2% over 24 h |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ZY-10 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Other Flue Gas Analyzer |
| Indication Error | ≤ Class 0.5 |
| Repeatability | ≤ 2% |
| Response Time | ≤ 60 s |
| Stability | ≤ 5% |
| Magnification | 10× |
| Objective Aperture | 50 mm |
| Ringelmann Scale Range | 0–5 (inclusive) |
| Visual Observation Accuracy | ≤ Class 0.5 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ZY-80 |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Visual Smoke Opacity Analyzer |
| Accuracy Class | ≤0.5 |
| Repeatability | ≤2% |
| Response Time | ≤60 s |
| Stability | ≤5% |
| Magnification | 15× |
| Observation Distance | 10–2000 m |
| Objective Aperture | 80 mm |
| Lingerman Scale Range | 0–5 |
| Reticle Imaging Magnification | 2× |
| Dimensions | 605 × 110 × 110 mm |
| Includes | Tripod Mount |
| Optional Accessory | Universal DSLR/Digital Camera Adapter Bracket |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZYET-5100 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Portable Flue Gas Analyzer |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time | ≤ 90 s (T₉₀) |
| Stability | ≤ ±5% FS/8 h |
| Measurement Principles | Electrochemical (O₂, NO, NO₂, SO₂, CO) |
| O₂ Range | 0–20.9 vol% |
| NO | 0–1000 ppm |
| NO₂ | 0–100 ppm |
| SO₂ | 0–2000 ppm |
| CO | 0–2000 ppm |
| Ambient Temp | 0–200 °C |
| Flue Gas Temp | 0–400 °C |
| Static Pressure | −30 to +30 kPa |
| Differential Pressure | 0–2.5 kPa |
| Resolution | O₂: 0.1 vol% |
| Gases | 1 ppm |
| Temp | 1 °C |
| Pressure | 0.01 kPa (Static), 1 Pa (Differential) |
| Accuracy | O₂: ±0.5% FS |
| Gases | ±5% FS |
| Temp | ±1% (Ambient), ±2% (Flue) |
| Pressure | ±3% FS |
| Data Storage | 500 measurement sets |
| Power | Internal 6 V × 2 rechargeable battery |
| Dimensions (W×D×H) | 417 × 234 × 318 mm |
| Weight | ~10 kg (configuration-dependent) |
| Operating Environment | −0°C to +40°C |
