Environmental Monitoring Instruments
Filter
Showing 391–420 of 2621 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 2100S / 3100 |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion (up to 1000 °C) and Dual-Wavelength UV Oxidation (185/254 nm) |
| CO₂ Detection | Focused NDIR with Integrated Optics |
| TOC Range | 0–30,000 mg/L (without dilution) |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A, DIN 38409-H3 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Optional Oxidation | Dual-Wavelength High-Intensity UV Photolysis (for wet chemical oxidation) |
| Detection Modules | NDIR for TOC/TC/TIC/NPOC/POC |
| Sample Introduction | Ceramic Valve-Based Loop Injection System |
| Sample Compatibility | Suspended-solids-rich wastewater, high-salinity matrices, ultrapure water, and solid samples (with optional solid module) |
| Automation Level | Fully Modular, Configurable for Unattended Operation |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Country of Origin | Imported |
| Model | multi N/C Pharma HT |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared Absorption (NDIR) for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion at up to 1000 °C |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | <3% RSD |
| Detection Limit | 4 ppb C |
| Resolution | 0.001 ppb C |
| Repeatability | ±3% RSD |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C UV HS |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Energy UV/Persulfate Oxidation + NDIR CO₂ Detection |
| Measurement Range | 0–30,000 mg/L TOC |
| Detector | High-Focus NDIR |
| Oxidation | Dual-Wavelength UV (185 nm & 254 nm) + Optional Persulfate |
| Compliance | DIN EN 1484, DIN EN 12260, DIN EN 15936, ISO 20236, HJ 501-2009, HJ 695-2014, GB/T 5750.7-2006 |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH & Co. KG |
| Product Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.03 ppb – 10,000 ppm C |
| Repeatability | <1% RSD |
| Compliance | ASTM D5905, ISO 8245, USP <643>, EP 2.2.44, DIN 38409-H41 |
| Software | TOC-Control v4.x with 21 CFR Part 11 compliance options |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | multi X 2500 |
| Price | Upon Request |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | multi N/C X300 |
| Instrument Type | Laboratory-based TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–30,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb |
| Detection Limit | 4 ppb (as C) |
| Repeatability | ≤1% RSD |
| Nitrogen Detection | Chemiluminescence Detector (CLD) and Conductivity Detector (ChD) |
| Calibration | Single-Standard EasyCal™ Protocol |
| Flow Control | VITA™ Variable Intelligent Time-Adaptive Flow Regulation |
| Safety System | SCS™ Self-Checking Safety System |
| Software Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols |
| Brand | Anasys |
|---|---|
| Origin | USA |
| Model | SMEC300 |
| Measurement Principles | Capacitive Volumetric Water Content (VWC), Four-Point Graphite Electrode EC, Precision Thermistor |
| Output | Analog Voltage (Time-Division Multiplexed) |
| VWC Range | 0–Saturation |
| VWC Resolution | 0.1% |
| VWC Accuracy | ±3% |
| EC Range | 0–10 mS/cm |
| EC Resolution | 0.01 mS/cm |
| EC Accuracy | ±2% |
| Temperature Range | −18 to +50 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.8 °C |
| Sensing Volume | 6 cm × 2 cm |
| Cable Options | 1.8 m, 6 m, extendable to 15 m |
| Power | 3 V DC @ 6–10 mA |
| Brand | AND/A&D |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AND1000 |
| Instrument Type | Portable |
| Detection Principle | Fluorescence-based Photometric Assay |
| Target Analyte | Lead (Pb) |
| Analysis Time | < 60 seconds |
| Detection Limit | 2 ppb |
| Quantification Range | 2–100 ppb |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Measurement Principle | DNAzyme-based Fluorescence Detection |
| Detection Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Update | Over-the-air via USB |
| Operating Languages | Multilingual (including Chinese) |
| Sensor Format | Discrete color-coded single-use cartridges |
| Sample Volume | 1 mL |
| Power | Rechargeable battery (USB charging) |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Detection Principle | DNAzyme-based Fluorescence Assay |
| Measurement Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Updates | Over-the-air via USB |
| Operating Languages | English, Chinese, and others |
| Power | Rechargeable battery (USB charging) |
| Sample Volume | 1 mL |
| Sensor Format | Discrete, color-coded single-use cartridges |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3150 Plus |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Gas-Phase Chemiluminescence (GPC) with Onboard Oxidation |
| Measurement Range | 0.08–100 mg/L NH₃–N |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.02 mg/L NH₃–N |
| Analysis Time per Sample | 1–3 minutes |
| Batch Capacity | 80 samples |
| Air Supply | Integrated Clean Air Generator (Atmospheric Pressure, No High-Pressure Cylinders Required) |
| Onboard Functions | Integrated Oxidation Module, Heating Module (for Nitrate & Total Nitrogen), Homogenizing Sparging System, Refrigerated Water Trap, Sintered-Glass Gas–Liquid Separator, Real-Time Graphical Monitoring, Auto-Dilution (≥40×), Adjustable Lamp Current & Automatic Light Gain Control |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-5750 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion Method (Closed-Tube, Reflux-Based) |
| Measurement Range | 16–700 mg/L COD |
| Accuracy | ≤5% (vs. Certified Reference Materials) |
| Repeatability | RSD ≤2.0% |
| Analysis Time | 14 minutes per sample |
| Batch Capacity | ≥21 samples |
| Safety Design | Fully Enclosed Digestion Chamber with Spherical Condenser |
| Operational Alert | Real-Time Reagent Vacuum Loss Detection |
| Compliance Context | Designed to support ISO 6060, ASTM D1252–06 (Method B), and HJ 828–2017 (Chinese EPA Standard) |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AJ-600 |
| Pricing | Available Upon Request |
| Dispensing Volume Range | 50–1000 mL |
| Dispensing Accuracy | ≤ ±2% |
| Temperature Control Range | 4–60 °C |
| Temperature Stability | ±1 °C |
| Full-Volume Preparation Time | <15 min |
| Onboard Protocol Storage | ≥10 preloaded methods |
| Integrated Log System | Audit-trail-capable user activity logging |
| Touchscreen Interface | Color LCD with intuitive GUI |
| Built-in Functions | Automated stirring, temperature regulation, system self-cleaning, headspace liquid-path purging, method recall and execution |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6400 |
| Target Analytes | Thallium (Tl), Lithium (Li) |
| Response Time | ≤2 min |
| Power Supply | Integrated Rechargeable Li-ion Battery (≥12 h continuous operation) |
| Operating Pressure | Ambient Atmospheric Pressure |
| Sample Introduction | Direct Liquid Injection (No Pretreatment Required) |
| Data Storage Capacity | >2000 Records with Real-time Spectral Display |
| Connectivity | USB for Data Export & Firmware Update |
| Compliance | Designed for Field Deployment under ISO/IEC 17025-aligned QA/QC Practices |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6400A |
| Detection Target | Thallium (Tl) in aqueous samples |
| Response Time | ≤2 min |
| Power Supply | Integrated rechargeable lithium battery (≥12 h continuous operation) |
| Data Storage | >2000 measurement records with real-time spectral display |
| Interface | Touchscreen GUI, USB for data export & firmware update |
| Operating Environment | Ambient atmospheric pressure, no external gas supply or AC power required |
| Sample Handling | Direct liquid injection, no pretreatment |
| Calibration | Built-in standard curves + on-site curve generation capability |
| Remote Diagnostics | Supported |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ5700 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion with Potassium Dichromate (Cr(VI)) Oxidation |
| Measurement Range | 0–700 mg/L COD<sub>cr</sub> |
| Accuracy | ≤5% (vs. certified reference materials) |
| Repeatability | RSD ≤2.0% |
| Cycle Time | <15 min per sample |
| Sample Capacity | ≥30 positions |
| Digestion Stations | ≥30 |
| Titration Stations | ≥2 |
| Reagent Dispensing Precision | ±0.2% |
| Safety Design | Negative-pressure enclosed chamber with fume containment |
| Waste Handling | Integrated废液 collection with overflow alarm |
| Connectivity | TCP/IP & Wi-Fi |
| Data Export Formats | PDF, Word, Excel, CSV, RTF, HTML |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | APA-500 |
| Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Type | Online Analyzer |
| Range | 0–5 mg/L |
| Repeatability | ±2% RSD |
| Accuracy | ±5% of reading |
| LOD | 0.05 mg/L |
| Resolution | 1 µL |
| Cycle Time | 4 min per sample |
| Temperature Control | 40–100 °C (adjustable water bath) |
| Environmental Monitoring | Integrated ambient temperature, humidity, and atmospheric pressure sensors |
| Sample Handling | Motorized adaptive gripper (pneumatic-free) |
| Endpoint Detection | RGB-spectral colorimetric endpoint simulation with real-time video recording |
| Compliance | Designed for ISO 8467:2021, EPA Method 4500-PERM, and GB/T 5750.7–2023 |
| Brand | ANJIE |
|---|---|
| Model | APA-500 |
| Origin | Shanghai, China |
| Sample Capacity | 48 positions |
| Water Bath Capacity | 8 positions |
| Sample Volume | 100 mL |
| Measurement Range | 0–5.0 mg/L |
| Repeatability | RSD ≤ 2.0% |
| Detection Limit | < 0.07 mg/L |
| Titration Resolution | 1 µL |
| Analysis Time | < 4 min per sample |
| Constant-Temperature Titration Temperature Range | 40–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Brand | Ankersmid |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Ankersmid |
| Price Range | USD 1,400 – 7,000 (est.) |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Preconditioning Unit |
| Measurement Accuracy | ±1% FS |
| Repeatability | ≤1% RSD |
| Response Time | ≤1 s (T90) |
| Drift Stability | ≤2% over 1 h |
| Measured Medium | Flue Gas (including CO, CO₂, SO₂, NOₓ, O₂, HCl, HF, NH₃, hydrocarbons, particulates, moisture) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DNM-4024 |
| Mixing Method | Dynamic Flow-Based Dilution |
| Instrument Type | Constant-Volume Dilutor |
| Dilution Ratio Range | 1:1 to 3000:1 (configurable or custom-expandable) |
| Dilution Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Equilibration Time | 2–30 minutes |
| Operating Temperature | 10–35 °C (recommended at 25 °C) |
| Operating Humidity | 10–90% RH (non-condensing) |
| Input Gas Channels | 2 (standard, expandable) |
| Output Flow Rate | 0–500 mL/min |
| Output Volume Range | 0–999 L |
| Flow Measurement Range | 0–1000 mL |
| Flow Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Power Supply | 24 V DC, 1 A |
| Max Power Consumption | 20 W |
| Dimensions (W×D×H) | 260 × 160 × 90 mm |
| Weight | ~1 kg |
| Applicable Gases | CH₄, CO, CO₂, volatile halogenated hydrocarbons, BTEX, sulfur compounds (e.g., H₂S, methanethiol), NOₓ, and other VOCs |
| Diluent Gases | Clean air, N₂, He |
| Compliance Standards | GB/T 14678–1993, HJ 1078–2019 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DNS-4024 |
| Mixing Method | Dynamic Flow-Based Dilution |
| Instrument Type | Multi-Channel Dynamic Gas Dilutor |
| Dilution Ratio Range | 1:1 to 1000:1 (standard configuration |
| Dilution Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Equilibration Time | 0.1–999 min |
| Input Channels | 2 (standard |
| Output Flow Rate | 0–5000 mL/min |
| Flow Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Analytical Timing Range | 0.1–999 min |
| Max Power Consumption | 20 W |
| Dimensions | 320 × 260 × 150 mm |
| Power Supply | 24 V DC, 1 A |
| Weight | ~2 kg |
| Compatible Carrier Gases | Clean Air, N₂, He |
| Target Analytes | CH₄, CO, CO₂, VOCs (e.g., halogenated hydrocarbons, BTEX), H₂S, other sulfur compounds, NOₓ |
| Concentration Range Supported | 10 ppb – 10,000 ppm |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | THB-8021 |
| Instrument Type | Portable |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Range | 1.0–50,000 ppm (as methane or propane equivalent) |
| Detection Limit | 0.5 ppm (FID, ethane |
| Repeatability | ±2% at 100 ppm methane (FID) |
| Accuracy | ±10% of reading or ±1.0 ppm (FID, whichever is greater) |
| Response Time (FID) | ≤3.5 s to 90% of final value (10,000 ppm CH₄) |
| Recovery Time (FID) | ≤4.5 s to within 10% of baseline (10,000 ppm CH₄) |
| Dynamic & Linear Range (FID) | 1.0–50,000 ppm |
| Detector Lifetime (FID) | >5,000 h (with routine maintenance) |
| Power Supply | Internal rechargeable battery (10 h operation, 4 h charge) |
| Dimensions | 219 × 260 × 70 mm |
| Weight | 4.1 kg |
| Operating Temperature | −10 to +50 °C |
| Data Output | USB (TXT format), Bluetooth, optional 4G/GPS |
| Intrinsic Safety | Certified for Class I, Division 1 hazardous areas (per IECEx/ATEX standards) |
| Compliance | Designed to support LDAR (Leak Detection and Repair) programs per US EPA Method 21, ASTM D6420, and ISO 16000-29 |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | AGA800 |
| Measurement Principle | Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Installation Type | In-situ probe-mounted |
| Response Time | ≤8 s |
| Operating Temperature (Probe) | Up to 400 °C (heated optical path) |
| Target Gases | SO₂, NO, NO₂ (total NOₓ) |
| Calibration | Automated in-situ optical zero/span correction |
| Compliance Context | Designed for continuous emission monitoring systems (CEMS) per HJ 75-2017 & HJ 76-2017 (China), compatible with ISO 12039, EN 15267, and EPA Method 6C/7E requirements |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ARX-C200 / ARX-G310 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% of Full Scale (F.S.) |
| Response Time | ≤ 200 s |
| Measured Parameters | SO₂, NO, NO₂, O₂, Particulate Matter (PM), Flue Gas Temperature, Static Pressure, Flow Velocity, Relative Humidity |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARX-C200H |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% F.S. |
| Response Time | ≤120 s |
| Measured Parameters | SO₂, NO, NO₂, O₂, NH₃, Particulate Matter (PM), Temperature, Pressure, Flue Gas Velocity, Relative Humidity |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARX-MA100 |
| Measurement Principle | Optical Scattering (for Particulates), Electrochemical (for SO₂/NO₂/CO/O₃), Photoionization Detection (PID) for TVOC |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, NO₂, CO, SO₂, O₃, TVOC, Temperature, Relative Humidity, Wind Speed, Wind Direction, Atmospheric Pressure |
| Optional Gases | NH₃, H₂S |
| Sampling Pump | Brushless Vacuum Pump with Stable Flow Control |
| Sample Conditioning | Dynamic Heating System (DHS) with Real-time Temperature Feedback |
| Data Transmission | Industrial-grade Multi-protocol Module (RS485, 4G LTE, Ethernet, LoRaWAN) |
| Alarm Function | Full-range Configurable Thresholds with Dry Contact Output for Dust Suppression Integration (e.g., Fog Cannon Trigger) |
| Compliance | Designed to Support ISO 12103-1, EPA EQOA-1 Reference Methods (for comparative monitoring), and GLP-aligned data logging architecture |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | LFS800 |
| Measurement Principle | Laser Forward Scattering |
| Sample Type | Wet Flue Gas |
| Measured Parameter | Particulate Matter (PM) |
| Range | 0–5 mg/m³ (Low Range), Dual-Range Auto-Switching |
| Detection Limit | 0.01 mg/m³ |
| Accuracy | ±10% (Gravimetric Reference Method) |
| Isokinetic Sampling Flow Rate | Up to 200 L/min |
| Heating | Full-Path Heated Sampling Line |
| Calibration | Automated Zero and Span Calibration |
| Display | Integrated LED Interface |
| Output | Analog 4–20 mA + Digital RS485/Modbus RTU |
| Compliance | Designed for China’s HJ 75–2017 & HJ 76–2017 CEMS Technical Specifications |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | LSS2014 |
| Measurement Principle | Laser Backscatter (90°–180° detection geometry) |
| Measurand | Particulate Matter (PM) in Flue Gas |
| Range | 0–20 mg/m³ (Ultra-Low Mode), Dual-Range Operation Supported |
| LOD | 0.05 mg/m³ |
| Installation Type | In-Situ, Non-Extractive |
| Gas Condition Requirement | Dry, Non-Condensing Flue Gas |
| Compliance Context | Designed for continuous emission monitoring systems (CEMS) per Chinese HJ 76-2017 and compatible with international flue gas monitoring frameworks (e.g., EN 15267, ISO 12141, US EPA Method 9 and Performance Specification PS-11) |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | MB11 |
| Instrument Type | Online Gas Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Optical Technique | High-Frequency Scanned Wavelength Modulation Spectroscopy with Dual-Wavelength Differential Compensation |
| Operating Environment | High-Temperature In-Situ or Extractive Sampling |
| Sample Handling | Heated Probe + Heated Sample Line (up to 200 °C) |
| Interference Resistance | Immune to H₂O, CO₂, SO₂, NOₓ, and Particulate Obscuration |
| Output Interfaces | 4–20 mA Analog, RS485 Modbus RTU, Relay Status Outputs, Optional Integrated Humidity Sensor |