| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AQ270 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 57 positions |
| Reagent Positions | 18 |
| Cuvette Path Length | 10 mm |
| Light Source | Halogen Lamp |
| Compliance | EPA-approved methods, ISO 15681, ISO 11923, ISO 7827 |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AQ300 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Positions | 57 or 97 (selectable) |
| Reagent Positions | 18 (with cooling capability) |
| Cuvette Path Length | 10 mm (quartz) |
| Light Source | Quartz-halogen lamp |
| Brand | SEAL |
|---|---|
| Origin | Imported |
| Model | AQ300 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 80 or 120 positions |
| Reagent Positions | 26 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | SEAL |
|---|---|
| Origin | Imported |
| Model | AQ400 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 80 or 120 positions |
| Reagent Positions | 26 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AQ400 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 80 or 120 positions |
| Reagent Positions | 26 (with refrigerated and ambient zones) |
| Cuvette Path Length | 10 mm (optional 20 mm) |
| Light Source | Quartz-halogen lamp |
| Detection Principle | Static photometric absorbance measurement using Hellma quartz flow cuvettes |
| Linear Range | 0.0001–3.500 AUFS |
| Resolution | 0.0001 AUFS |
| Reaction Temperature Control | 30–45 °C (±0.1 °C) |
| Sample Volume Precision | 0.5–500 µL (0.5 µL increments) |
| Reagent Dispensing | 10–600 µL (0.5 µL increments) |
| Max. Throughput | 200 samples/hour |
| Calibration | Up to 20-point multi-level calibration |
| Auto-dilution | Up to 100× pre- and post-analysis |
| Compliance | CE, UL, CSA |
| Power | 220 V, 50 Hz, 150 W |
| Dimensions (W×D×H) | 70 × 22 × 62 cm |
| Weight | 43 kg |
| Operating Environment | 5–40 °C, 5–95% RH |
| Brand | SEAL |
|---|---|
| Model | AQ700 |
| Instrument Type | Discrete Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 1 rack (up to 120 positions, configurable per tray) |
| Reagent Positions | 1 rack (up to 60 positions) |
| Cuvette Pathlength | 10 mm |
| Light Source | Tungsten-halogen lamp |
| Detection Principle | Photometric Absorption Spectrophotometry |
| Automation Architecture | 4-axis robotic arm with 4 independent sample trays |
| Operational Mode | Unattended batch processing with integrated reagent cooling and temperature-controlled reaction zones |
| Brand | SEAL |
|---|---|
| Origin | Netherlands |
| Model | AS2 |
| Sample Capacity | 180 × 0.5–2 mL vials or 120 × 4–10 mL vials |
| Compatible Platforms | SEAL AA500 Continuous Flow Analyzers, SEAL segmented flow analyzers, AACE software |
| Material | Stainless steel & PEEK probe |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 120 / 180 / 270 positions |
| Reagent Positions | Unlimited |
| Flow Cell Path Length | 10 mm, 50 mm |
| Light Source | High-Pressure Krypton Lamp or LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | QuAAtro |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 120 / 360 / 540 positions |
| Reagent Positions | 39 |
| Cuvette Path Length | 10 mm |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | Sampler 6 |
| Instrument Type | Automated Sampler for Continuous Flow Analyzers (CFA) |
| Sample Capacity | 89 positions (10 mL vials) |
| Sampling Mode | Random-access, non-sequential |
| Wash Pump | Integrated visual wash pump |
| Probe Compatibility | Chemically resistant stainless steel needle (acid-compatible) |
| Sample Types | Aqueous, acidic, and buffered solutions |
| Integration | Designed exclusively for SEAL AA1001 Continuous Flow Analyzer |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Instrument Type | 3D Robotic Autosampler |
| Sample Capacity | Up to 540 positions (6 sample racks) |
| Needle Configuration | Single, dual, or quad needle options |
| Compatible Platforms | SEAL AA3 and QuAAtro continuous flow analyzers |
| Sample Vial Sizes | 4 mL, 5 mL, and 11 mL |
| Dedicated Standard & QC Racks | Yes |
| Random Access Sampling | Yes |
| Acid-Resistant Needle Material | PTFE-coated stainless steel |
| Compliance | Designed for GLP/GMP environments with audit-ready operation |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XY-2 / XY-3 |
| Product Category | Continuous Flow Analyzer (CFA) Sampler |
| Sample Positions | 270 / 180 / 120 |
| Max Sample Vessel Height | 150 mm |
| High-Profile Variant Compatibility | Standard 300 mL Laboratory Tubes |
| Interface | USB 2.0 |
| Optional Injector Dilutor | SEAL Injector Dilutor 3 (2.5 mL / 5 mL / 10 mL syringe volumes) |
| Software Control | AACE v5.x or later with variable-speed dilution protocol support |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020BJ |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Cup Capacity | 100 / 180 / 270 positions (5 mL, 8 mL, or 10 mL per cup) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Pathlength | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020FL |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Volumes | 5/8/10 mL per cup |
| Capacity | 100/180/270 positions |
| Reagent Positions | 100/180/270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | FLOWSTAR 2020HS |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Volumes | 5 mL / 8 mL / 10 mL |
| Sample Rack Capacity | 100 / 180 / 270 positions |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Path Lengths | 10 mm / 30 mm / 50 mm |
| Light Source | LED or Krypton Lamp |
| Detection Principle | Segmented Flow Analysis (SFA) with Air Segment Isolation, Dual-Beam Dual-Wavelength Photometry |
| Compliance | HY/T 147.1, GB 5750, HJ 665/667/670, SL/T 788, CJ/T 141, ISO 6878, ISO 11905-1, EPA 353.2, APHA 4500-N, AOAC Official Methods |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | Flowstar 2020NY |
| Price Range | USD 28,000 – 70,000 (FOB Shanghai) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Carrier Capacity | 100 / 180 / 270 positions (vials: 5 mL, 8 mL, or 10 mL) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | High-Stability LED and Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020YC |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Capacity | 100 / 180 / 270 positions (vials of 5, 8, or 10 mL) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Pathlength | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMARTCHEM 140 |
| Pricing | Available Upon Request |
| [Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 200 |
| Product Type | Discrete Flow Analyzer |
| Measurement Speed | 200 samples/hr |
| Sample Capacity | 5 racks × 126 positions |
| Reaction Temperature | 37.2 °C ± 0.1 °C |
| Optical Range | 420–880 nm |
| Absorbance Linearity | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 300 µL |
| Pipetting Range | 3–450 µL |
| Dilution Factor | Up to 100× |
| Reagent Positions | 16 (10 refrigerated + 6 ambient) |
| Standard Positions | 10 |
| Diluent Positions | 2 |
| Filter Wheel | 9 optical filters + 1 blank filter |
| Reaction Cuvettes | 60-position rotating disc, semi-reusable, auto-cleaned and QC-verified |
| Compliance | ASTM, ISO, AOAC, US EPA Method 353.2 (NO₃⁻/NO₂⁻), AFNOR, COFRAC, BATF, USEPA] |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
| Brand | Systea |
|---|---|
| Origin | Italy |
| Model | Easychem Pro |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (standard carousel) / 30 positions (dual-carrousel configuration) |
| Reagent Positions | 30 |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Output |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA 7Plus |
| Product Type | Flow Injection Analyzer |
| Category | Chemical Analysis Instrumentation — General Analytical Instruments — Flow Injection Analyzer |
| Manufacturer Status | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Type | Integrated Flow Injection Analyzer (FIA) System |
| Configuration | Fully Automated, Channel-Independent Modular Design |
| Standard Package | Auto-sampler, Main Unit, Control PC, Thermal Printer |
| Optional Modules | MAC3 Multi-Analyte Configuration Module (17 parameters) |
| Compliance Context | Designed for ASTM D129, ISO 6775, ISO 1192, EPA 300.0, EPA 354.1, USP <643>, and GLP/GMP-aligned data integrity workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 10–50 mL per vial / 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA L9 |
| Wavelength Range | 600–700 nm |
| Sample Capacity | 50–212 positions |
| Reagent Ports | 7 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA5+ |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA7 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 Plus |
| Product Type | Flow Injection Analyzer |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | iFIAE |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume Capacity | 10–50 mL per vial |
| Sample Tray Capacity | 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Halogen Lamp |