Food Safety Rapid Detectors
Filter
Showing 91–120 of 163 results
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-B |
| Price | USD 1,800 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Fresh and Processed Meat Samples |
| Wavelength Range | 410–630 nm |
| Assay Time | ≤ 3 min per sample |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 8 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-CHN |
| Price | USD 780 (approx.) |
| Functionality | Single-analyte, dedicated assay |
| Sample Format | Homogenized tissue extract (liquid phase) |
| Wavelength Range | 400–680 nm |
| Assay Time | <120 s per sample |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 1 |
| Detection Limit | 10 mg/100 g in fish and aquatic animal tissues |
| Linear Range | 10–200 mg/100 g (typical for enzymatic/colorimetric histamine assays) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-FM2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-analyte Quantitative Detection |
| Sample Type | Dedicated to Honey Matrix Only |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Display | 4.3-inch Color TFT Touchscreen |
| Absorbance Range | 0.000–4.000 (Resolution: 0.001) |
| Transmittance Range | 0.00–100.00% (Resolution: 0.01%) |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.3% drift over 3 min |
| Detection Limits & Ranges | Fructose + Glucose — LOD 12.0%, Range 0–95.0% w/w |
| Interface | RS-232, USB 2.0 |
| Power Options | Internal Rechargeable Li-ion Battery, DC 5 V Input, AC 220 V ±10% 50/60 Hz |
| Dimensions & Weight | 220 × 160 × 85 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-GYS2 |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min |
| Repeatability | <5% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Stability (3 min) | ≤0.3% |
| Peroxide Value Detection Limit | 0.05 g/100g |
| Peroxide Value Range | 0.05–5.00 g/100g |
| Acid Value Detection Limit | 0.1 mg KOH/g |
| Acid Value Range | 0.0–30.0 mg KOH/g |
| Interface | RS232, USB |
| Power Supply | AC 220 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-NH2 |
| Price | USD 780 (FOB Shanghai) |
| Functionality | Single-Analyte Detection System |
| Sample Format | Single-sample cuvette-based assay |
| Wavelength Range | 400–680 nm |
| Analysis Time | <120 s per sample |
| Relative Standard Deviation (RSD) | <5% |
| Detection Channels | 1 |
| Detection Limit | 200.0 mg/kg |
| Quantification Range | 0–15,000 mg/kg |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability | ≤1.0% |
| Dark Current Drift | ≤0.5% over 3 min |
| Power Supply | AC 220 V / DC 12 V (with rechargeable 12 V Li-ion battery) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SP-Z2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Milk Powder & Liquid/Processed Dairy Matrices |
| Wavelength | 540 nm (Fixed-Channel Photometric Detection) |
| Assay Time | ≤180 seconds per sample |
| Photometric Repeatability | ≤0.2% CV |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SPb-201FM |
| Wavelength Range | 400–680 nm (discrete fixed wavelengths at 410 nm, 510 nm, 630 nm) |
| Detection Time | <2 min per sample |
| Repeatability | ≤5% CV |
| Optical Resolution | Absorbance 0.001 AU |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.2% T (3 min) |
| Detection Channels | 1 |
| Sample Type | Liquid honey (pre-diluted or direct injection per protocol) |
| Compliance | Designed for routine QC in food processing labs compliant with GB 14963–2011 (Chinese National Standard for Honey), supports internal GLP documentation workflows |
| Connectivity | USB interface for data export |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-AJ2 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Throughput | Single-Sample Mode |
| Optical Wavelength | 410 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BH2 |
| Price | USD 1,080 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Type | Dedicated Single-Sample Format |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BJ2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Format | Single-Sample Mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (at 540 nm) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-CX2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cartridge/Tube |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% RSD |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | SPb-DB2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Type | Solid/Liquid Food Matrices (Homogenized Extracts) |
| Optical Wavelength | 410 nm |
| Assay Time per Sample | ≤ 180 s |
| Photometric Repeatability (Transmittance) | ≤ 0.2% RSD |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-DL2 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Type | Single-Sample Format |
| Wavelength | 630 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-DY2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-analyte, dedicated assay |
| Sample Type | Solid edible salt samples only |
| Wavelength | 540 nm |
| Assay Time | ≤3 min per sample |
| Photometric Repeatability | ≤0.2% (transmittance) |
| Optical Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (transmittance) |
| Baseline Stability | ≤0.3% over 3 min |
| LOD | 2.0 mg/kg |
| Quantitation Range | 0–80 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply | Rechargeable Li-ion battery (7.4 V, 4400 mAh), AC 220 V ±10%, DC 5 V input |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-EY2 |
| Price | USD 795 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Type | Single-Sample Dedicated Use |
| Optical Wavelength | 540 nm |
| Assay Time | ≤3 min per sample |
| Photometric Repeatability | ≤0.2% (Transmittance) |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (Transmittance) |
| Baseline Stability | ≤0.3% over 3 min |
| SO₂ LOD | 1.0 mg/kg |
| SO₂ Linear Range | 0–500 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply | Internal rechargeable Li-ion battery (7.4 V/2600 mAh), AC 220 V ±10%, DC 5 V input |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | SPb-GB2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Format | Single-Sample Mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-GY2 |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Edible Oil Samples Only |
| Wavelength | 540 nm |
| Assay Time | ≤ 3 min per sample |
| Photometric Repeatability | ≤ 0.5% |
| Absorbance Range | 0–2.500 A |
| Detection Limit | 0.3 mmol/kg |
| Measurement Range | 0–11 mmol/kg |
| Photocurrent Drift | ≤ 0.002 A (within 3 min) |
| Data Interface | RS-232 |
| Power Supply | 9 V DC battery / 9 V DC adapter / 220 V AC input |
| Dimensions | 175 × 100 × 85 mm |
| Net Weight | < 0.8 kg |
| Detection Channel | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SPb-HF2 |
| Price | ¥7,800 |
| Functionality | Single-Analyte Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Assay Time | ≤3 min |
| Repeatability | ≤0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-I2 |
| Function Type | Single-Parameter Detection System |
| Sample Type | Dedicated to Edible Salt Samples |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min per sample |
| Repeatability (RSD) | <5% |
| Detection Channels | 1 |
| Absorbance Display Range | 0.000–4.000 |
| Transmittance Display Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Baseline Stability (3 min) | ≤0.3% |
| Limit of Detection (LOD) | 0.1 mg/kg |
| Quantification Range | 0–10 mg/kg |
| Communication Interfaces | RS232, USB |
| Power Options | Integrated Li-ion battery, AC 220 V, DC 5 V |
| Built-in Thermal Printer | Yes |
| Touchscreen | 4.3-inch HD color LCD with Chinese UI |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SPb-JAS2 |
| Price Range | USD 2,800 – 4,200 |
| Function Type | Single-Analyte Detection System |
| Sample Format | Single-Sample Dedicated Platform |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JC2 |
| Price | USD 790 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-JCd2 |
| Price Range | USD 4,200 – 7,000 |
| Functionality | Single-Analyte Detection (Cadmium Only) |
| Sample Format | Single-Sample Dedicated System |
| Optical Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JHg2 |
| Price Range | USD 4,200 – 7,000 |
| Functionality | Single-Analyte Detection (Mercury Only) |
| Sample Format | Single-Sample Dedicated Use |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JPb2 |
| Functionality | Single-Analyte Detection (Lead Only) |
| Sample Format | Single-Sample Dedicated Use |
| Wavelength | 540 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3 min) | ≤0.3% |
| LOD for Pb | 0.5 mg/kg |
| Quantification Range for Pb | 0–15 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply | Integrated Li-ion Battery, AC 220 V, DC 5 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JQ2 |
| Price | USD 1,380 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Single-Sample Dedicated System |
| Optical Wavelength | 410 nm |
| Detection Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JS2 |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Type | Rapeseed Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% |
| Optical Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3 min) | ≤0.3% |
| Limit of Detection (Erucic Acid) | 0.5% (w/w) |
| Interface | USB |
| Power Supply | AC 220 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LG2 |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Type | Rapeseed Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability (RSD) | ≤0.2% |
| Optical Channels | 1 |
| Absorbance Display Range | 0.000–4.000 |
| Transmittance Display Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.3% |
| Limit of Detection (LOD) | 10 µmol/g |
| Interface | USB |
| Power Supply | 220 V AC |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LL2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cartridge/Well |
| Optical Wavelength | 630 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LS2 |
| Price | USD 920 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Dedicated Single-Sample Cartridge |
| Wavelength | 630 nm |
| Assay Time | ≤ 180 s |
| Optical Repeatability (Transmittance) | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-PS2 |
| Price Range | USD 2,800 – 4,200 (FOB Shanghai) |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Single-Sample Format |
| Optical Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Measurement Channels | 1 |
