Food Safety Rapid Detectors
Filter
Showing 61–90 of 164 results
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102B |
| Price Range | USD 1,400–2,800 |
| Function Type | Multi-analyte Quantitative Immunoassay Reader |
| Sample Format | Single-strip Lateral Flow Assay (LFA) Cartridge |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time | ≤ 180 s per strip |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-102Cd |
| Price Range | USD 1,400 – 2,800 |
| Function Type | Multi-analyte (Cadmium-focused with expandable panel) |
| Sample Applicability | Generic for cereal grains and milled rice matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per test |
| Repeatability (CV) | ≤0.3% |
| Detection Channels | 6 independent lateral-flow strip readers |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102DY |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Format | Single-strip, Lateral Flow Assay (LFA) Cartridge |
| Optical Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time | ≤ 180 s per test |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Measurement Speed | < 0.5 s per image capture |
| Quantitative Precision | CV < 1% (using certified reference lateral flow strips) |
| Sensitivity Threshold | ≤ 0.001 OD unit (optical density) |
| Output Modes | Colorimetric analysis, C/T ratio calculation, Test line (T) and Control line (C) intensity quantification |
| Data Storage | 32 GB internal flash memory (≥100,000 assay records with full-image archiving) |
| Operating System | Windows 10 IoT Enterprise |
| Processor | Intel quad-core, 14 nm architecture |
| Display | 8.3-inch capacitive touchscreen (1280 × 800) |
| Connectivity | USB 2.0, Wi-Fi 802.11ac, Bluetooth 5.0, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Internal Battery | Rechargeable Li-ion, ≥24 h standby |
| Power Consumption | <10 W (operational) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102JD |
| Function Type | Single-Analyte Rapid Immunoassay Platform |
| Sample Type | Egg and Duck Egg Matrix Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 s per test |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Measurement Speed | < 0.5 s per image capture |
| Optical Precision | CV < 1% (certified control strips), Inter-batch Variation < 3% |
| Sensitivity Threshold | < 0.001 ng/mL (matrix-dependent, per validated analyte) |
| Data Storage | 16 GB internal (expandable to 32 GB), ≥ 100,000 test records with full-image archiving |
| Power Supply | AC 220 V / 5 V DC / Internal Li-ion battery (≥24 h standby) |
| Power Consumption | < 10 W |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, Optional 3G/4G module |
| Output Formats | C/T line intensity ratio, colorimetric quantification, CT value, digital chromatographic profile export (CSV, PDF, XML) |
| Regulatory Alignment | Designed for compliance with GB/T 22286–2008, NY/T 761–2008, and supports audit-trail-ready data handling per GLP principles |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-102M |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Reader |
| Sample Format | Single-strip lateral flow assay (LFA) |
| Optical Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time per Test | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-103JS |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte (Cd, Pb, and expandable panel) |
| Sample Compatibility | Cereals, rice, flour, feed, edible oils, and processed food matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤180 seconds per sample |
| Repeatability (RSD) | ≤0.3% |
| Detection Channels | 3 independent optical lanes |
| Detection Limits | Cd ≤0.2 ppm, Pb ≤0.1 ppm |
| Measurement Speed | <1 second per test strip image capture |
| Output Metrics | Colorimetric intensity, C/T ratio, T-line intensity, C-line intensity, qualitative/quantitative classification |
| Interface | USB 2.0 |
| Connectivity | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 4G LTE module |
| Operating System | Android 7.0 |
| Hardware | Quad-core ARM processor, 2 GB RAM, 16 GB internal storage + microSD expansion |
| Display | 10.1-inch capacitive touchscreen |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Built-in Thermal Printer | Yes |
| Cloud Integration | HTTPS-based secure API for Ruixin Cloud Platform (ISO/IEC 27001-compliant infrastructure) |
| Data Compliance | Supports audit trail, user login authentication, and GLP-aligned electronic record retention |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JT-103M |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Feed, Herbal Medicines, Edible Oils, Condiments, Milk & Dairy Products |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Optical Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 3 independent optical lanes |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-103SY |
| Price | USD 5,300 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Applicability | Universal for Animal-Derived Foods |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 3 minutes per test |
| Repeatability | ≤ 0.3% CV |
| Detection Channels | 3 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-108B |
| Price | USD 5,300 (approx.) |
| Functionality | Multiplex Rapid Screening Platform |
| Sample Versatility | Universal for Solid & Liquid Food Matrices |
| Optical Detection Range | 380–680 nm |
| Assay Time per Test | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 10 parallel optical lanes |
| Image Acquisition | High-Resolution CCD Sensor |
| Data Output | C/T Ratio, Colorimetric Intensity, Control Line (C), Test Line (T), Qualitative/Quantitative Interpretation |
| Connectivity | Wi-Fi 802.11 b/g/n, RJ45 Ethernet, USB 2.0, Optional 4G LTE Module |
| Operating System | Android 9.0 (Custom Embedded UI) |
| Display | 10.1-inch Capacitive Touchscreen |
| Onboard Storage | Internal eMMC + SD Card Slot (Supports ≥128 GB, >1,000,000 records) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JT-108Cd |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Flour, Paddy, Polished Rice, and Processed Cereal Matrices |
| Optical Detection Range | 380–680 nm |
| Assay Time per Batch | ≤3 min (including image capture & AI quantification) |
| Photometric Repeatability (CV) | ≤0.3% |
| Detection Channels | 6 independent optical lanes |
| LOD for Cd in Rice | 0.1 ppm (mg/kg) |
| Imaging Speed | <1 s per test strip |
| Quantitative Accuracy | CV <1% (intra-assay, certified control strips), Inter-batch Variation <3% |
| Output Modes | Colorimetric Intensity, C/T Ratio, T-line Absorbance, C-line Normalization |
| Interface | USB 2.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JT-108JS |
| Price Range | USD 2,800 – 4,300 (FOB Shanghai) |
| Function Type | Multi-analyte (Pb, Cd) |
| Sample Compatibility | Solid & semi-solid food matrices (grains, vegetables, herbs) |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤15 min (full assay cycle) |
| Repeatability (CV) | ≤0.3% |
| Detection Channels | 10 independent optical channels |
| LOD for Cd | 0.2 ppm |
| LOD for Pb | 0.1 ppm |
| Imaging Speed | <1 s per strip |
| Quantification Accuracy | CV <1% (within-run, certified control strips) |
| Output Modes | Colorimetric intensity, C/T ratio, T-line presence/absence, C-line validation |
| Interface | USB 2.0 |
| Connectivity | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JT-108JY |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Legume, Leaf, and Processed Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Optical Reproducibility (CV) | ≤ 0.3% |
| Detection Channels | 10 parallel lateral-flow immunoassay (LFIA) readers |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JT-108M |
| Detection Principle | Immunochromatographic Colloidal Gold Assay |
| Optical Detection Range | 380–680 nm |
| Detection Time | ≤ 3 min per sample |
| Measurement Speed | < 1 s per test strip |
| Detection Channels | 10 parallel |
| Repeatability (CV) | ≤ 0.3% |
| Precision | CV < 1% (standard test strips), inter-batch variation < 3% |
| Sensitivity | LOD down to 0.5 ppb (aflatoxin B₁ and M₁) |
| Quantitative Output | C/T ratio, colorimetric intensity, control line (C) & test line (T) signal analysis |
| Data Storage | Internal SD card support, ≥ 1 million records |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Display | 10.1-inch capacitive touchscreen, Android OS |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Designed for ISO/IEC 17025-aligned workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108SC |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Compatibility | Universal for Aquatic Products (e.g., shrimp, fish, crab, mollusks) |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Repeatability (CV) | ≤ 0.3% |
| Number of Detection Channels | 6 |
| Measurement Speed per Strip | < 1 s |
| Precision | CV < 1% (certified control strips), Inter-batch Variability < 3% |
| Sensitivity | LOD ≤ 0.001 µg/kg (matrix-dependent, per analyte-specific validation) |
| Output Modes | Colorimetric Intensity, C/T Ratio, Test Line (T), Control Line (C) Quantification |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE Module |
| Power Supply | AC 220 V ±10%, 50 Hz (with optional Li-ion battery pack for field use) |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | JT-108SR |
| Price | USD 5,300 (approx.) |
| Function Type | Multi-analyte Screening Platform |
| Sample Compatibility | Universal for Porcine, Bovine & Ovine Tissues |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤180 s per assay |
| Repeatability (CV) | ≤0.3% |
| Detection Channels | 8 parallel optical readout units |
| Measurement Speed | <1 s per test strip |
| Precision | CV <1% (intra-assay, certified control strips) |
| Sensitivity | LODs ranging from 0.5 ppb (clenbuterol, salbutamol, ractopamine) to 100 ppb (ribavirin) |
| Output Modes | Chromaticity analysis, C/T ratio quantification, T-line intensity, C-line validation |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating System | Android-based embedded UI |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal eMMC + microSD expansion (≥1 million records) |
| Connectivity | Cloud API support, QR-code–enabled traceability, GPS/AGPS geotagging |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JT-108SY |
| Price | USD 3,950 (approx.) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Applicability | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 s per assay |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 6 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108SY |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 s per test strip |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 8 independent optical lanes |
| Measurement Speed | < 1 s per lane |
| Precision | CV < 1% (certified control strips), Inter-batch Variation < 3% |
| Sensitivity | LOD < 0.001 ng/mL (matrix-dependent, per analyte) |
| Output Modes | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) validation |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50 Hz (with optional Li-ion battery pack) |
| Operating System | Android 9.0 |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), ≥ 1,000,000 records |
| Connectivity Protocols | HTTP/HTTPS, MQTT, TLS 1.2 |
| Cloud Integration | RESTful API compliant with ISO/IEC 17025 traceability framework |
| Compliance | Designed in alignment with GB/T 27404–2008 (CNAS GLP guidelines), supports audit-ready data logs per FDA 21 CFR Part 11 requirements (electronic signatures, time-stamped audit trails, role-based access) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-108SYFM |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Format | Single-format Strip-Based Assay |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 8 parallel optical paths |
| Measurement Speed per Channel | < 1 s |
| Inter-batch CV | < 3% |
| Sensitivity Limit | ≤ 0.001 ng/mL (typical for chloramphenicol in honey matrix) |
| Output Metrics | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Power Supply | AC 220 V ±10%, 50 Hz (optional Li-ion battery pack available) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet, optional 4G LTE module |
| Data Storage | Internal eMMC + microSD slot (up to 128 GB), ≥ 1,000,000 test records |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108Y |
| Price | USD 9,200 (approx.) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Compatibility | Universal for Solid & Liquid Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 seconds per test strip |
| Repeatability | ≤ 0.3% CV |
| Detection Channels | 10 independent optical channels |
| Measurement Speed | < 1 second per channel |
| Output Metrics | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE module |
| Positioning | Integrated GPS/AGPS |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), ≥ 1,000,000 records |
| Display | 10.1-inch capacitive touchscreen, Android OS 11 |
| Printing Options | Thermal label printer (adhesive), thermal roll paper, A4 inkjet-compatible export |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NCD-100A |
| Price | USD 10,800 (FOB Shanghai) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Broad-spectrum food & agricultural matrices |
| Wavelength Range | 410–630 nm (with fixed filters at 410, 450, 540, 630 nm |
| Assay Time | ≤180 seconds per 96-well plate |
| Photometric Repeatability | ±1.0% CV or ±0.007 Abs |
| Detection Channels | 96 / 48 / 24-well configurable microplate format |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NCD-96DY |
| Detection Principle | Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength Range | 400–1100 nm |
| Optical Channels | 96-well microplate format |
| Photometric Accuracy | ±0.005A (repeatability, 0–2A) |
| Measurement Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ±2.0 nm |
| Bandwidth | 8 ±1.0 nm |
| Inter-channel Variation | ≤0.02A |
| Stability | ≤0.005A/hour |
| Stray Light | ≥2.0A at 510 nm (50.0 g/L NaNO₂) |
| Read Time | ≤5 s per plate |
| Data Storage | ≥100,000 test records |
| Calibration Curves | Up to 126 stored protocols |
| Analysis Modes | Qualitative (positive/negative), quantitative (concentration, P/CO, cutoff), semi-quantitative |
| Curve Fitting Algorithms | 9 methods including linear, logit-log, 4PL, quadratic, exponential regression |
| Interface | RS-232, USB |
| Software Compliance | Supports FDA 21 CFR Part 11 audit trail (via PC-hosted Ruixin ELISA Manager v3.x), GLP/GMP data integrity features |
| Regulatory Alignment | Compatible with ISO 15197, CLSI EP12-A2, and veterinary diagnostic validation frameworks per OIE Terrestrial Manual |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NCD-96S |
| Function Type | Multi-analyte Quantitative & Qualitative Detection |
| Sample Compatibility | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 400–1100 nm |
| Detection Time | ≤3 min per 96-well plate |
| Photometric Repeatability | ±0.005 A (0–2 A) |
| Detection Channels | 96-well microplate format |
| Optical System | Auto-calibrating 8-channel photometric system with standard filters at 405/450/492/630 nm (expandable to 10 filters) |
| Light Source | Quartz halogen lamp with auto-dimming idle mode |
| Absorbance Range | 0.000–4.000 A |
| Resolution | 0.001 A |
| Accuracy | ±1% (0–2 A) |
| Linearity Error | ±0.1% (0–2 A) |
| Inter-channel Variation | ≤0.02 A |
| Stability | ≤0.005 A/h |
| Stray Light | ≥2.0 A at 510 nm using 50.0 g/L sodium nitrite solution |
| Plate Read Time | 5 s |
| Data Storage | ≥100,000 test records |
| Analysis Methods | 9 algorithmic models including linear regression, semi-log, log-log, ratio-based, exponential, and quadratic curve fitting |
| Compliance Support | Configurable audit trail, user access levels, and data export compliant with GLP documentation workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RFE-3 |
| Price Range | USD 4,200 – 7,000 |
| Detection Range | 0–9999 RLU |
| LOD | 1×10⁻¹⁶ mol ATP |
| Detection Time | 10 s |
| Repeatability | CV ≤ 8% |
| Detection Channels | 1 |
| Display | LCD |
| Detection Principle | Bioluminescent reaction between ATP and luciferin-luciferase complex |
| Communication Interface | RS232 (Wi-Fi optional per firmware upgrade) |
| Power Supply | Rechargeable Li-ion battery |
| Form Factor | Handheld |
| Net Weight | 400 g |
| Light Source | LED |
| Sample Volume | 1 mL per swab |
| Swab Tube Dimensions | Ø12 × 155 mm |
| Data Storage | 2000 records |
| Limit Sets | 100 user-defined thresholds |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 15–95% RH |
| Battery Life | ≥200 h (AA alkaline, 2 pcs) or equivalent Li-ion cycle |
| Output Units | RLU and configurable CFU (via user-defined conversion factor) |
| Compliance | ISO 15161:2001 (Food & Beverage sector application of ISO 9001), aligned with ISO 22000 hygiene validation requirements |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | RSY-1 |
| Price Range | USD 1,400–2,800 |
| Function Type | Single-parameter Detection |
| Sample Type | Single-species Dedicated |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.3% (70–80% w/w moisture range) |
| Measurement Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-1001AC |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Function Type | Multi-analyte Quantitative Detection System |
| Sample Compatibility | Solid and Liquid Extracts from Tea, Leafy Produce, and Herbal Matrices |
| Wavelength Range | 410–630 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability | ≤ 1.0% (Transmittance) |
| Optical Channels | 8 independent photometric channels |
| Absorbance Accuracy | ±2.0% T |
| Dark Current Drift | ≤0.5% over 3 min |
| Detection Limits | 5.0 mg/kg for all listed analytes |
| Linear Dynamic Range | 0–200 mg/kg (pyrethroids, organophosphates) |
| Brand | Ruixin |
|---|---|
| Model | SP-1001T |
| Origin | Shanghai, China |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min |
| Repeatability | <5% |
| Detection Channels | 8 |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | 1.0% T |
| Dark Current Drift | 0.5% (3 min) |
| Dimensions | 470 × 280 × 150 mm |
| Function Type | Single-analyte Quantitative Detection |
| Sample Compatibility | Multi-sample Universal Format |
| Interface | USB |
| Data Output | Built-in Thermal Printer + PC Software Integration |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-1218D |
| Function Type | Multi-parameter rapid detection (spectrophotometric + dry immunochromatographic gold nanoparticle assay) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.3% (photometric), CV <1% (colloidal gold) |
| Detection Channels | 12 independent optical channels |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±0.5% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Overall Measurement Accuracy | ±5% (vs. reference standards) |
| Colloidal Gold Module | 3 dedicated readers with CT-ratio, colorimetric, and T/C line quantification |
| Connectivity | USB ×3, Wi-Fi, Bluetooth 4.2, 4G LTE |
| Power Supply | AC 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-2418D |
| Function Type | Multi-parameter rapid detection (expandable to 100+ assays) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.2% T |
| Optical Channels | 24 independent photometric channels |
| Colloidal Gold Reader Modules | 3 standard (expandable to 10) |
| Display | 10.1″ capacitive touchscreen (Android OS) |
| Data Connectivity | RJ45 Ethernet, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 4G LTE Cat.4 |
| Power Supply | AC 220 V ±10% |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Overall Measurement Accuracy | ±5% (relative to reference methods) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP-801B |
| Function Type | Multi-parameter (60+ configurable assays) |
| Sample Compatibility | Universal for liquid, extract, and homogenized food matrices |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time per Channel | ≤ 180 s |
| Photometric Repeatability (Transmittance) | ≤ 0.2% |
| Absorbance Resolution | 0.001 AU |
| Transmittance Resolution | 0.01% |
| Optical Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.2% |
| Detection Channels | 24 simultaneous cuvette-based optical paths |
| Display | 7.0-inch capacitive touch TFT-LCD (800×480) with full Chinese UI |
| Data Output | Embedded thermal printer, RS232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-801D |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.3% (T) |
| Optical Channels | 8 independent photometric channels + 1 integrated colloidal gold lateral flow reader |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Absorbance Resolution | 0.001 A |
| Transmittance Resolution | 0.01% T |
| Photometric Accuracy | ±2.0% (T) |
| Dark Current Drift | ≤0.3% over 3 min |
| Measurement Accuracy | ±5% (relative to reference standards) |
| Operating System | Android 9.0 or Windows 10 IoT Enterprise (pre-installed) |
| Storage | 32 GB eMMC (expandable to 64 GB) |
| RAM | 2 GB DDR4 |
| Connectivity | Dual-band Wi-Fi (802.11 a/b/g/n/ac), Bluetooth 5.0, optional 3G/4G LTE module |
| Power Supply | AC 220 V ±10% / Internal rechargeable Li-ion battery (5 h continuous operation) |
| Display | 10.6-inch capacitive multi-touch LCD (1920×1080) |
| Compliance | Designed for GLP-aligned workflows |
