Food Safety Rapid Detectors
Filter
Showing 31–60 of 164 results
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-4000S |
| Function Type | Single-Analyte Detection (Iodine) |
| Sample Versatility | Multi-Sample Compatible |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–80.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤3 minutes per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, parameter configuration, statistical processing, and RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-501S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Universal for Food & Biological Matrices |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Repeatability | ≤ ±1% |
| Linearity | ±1% (0.000–2.000 A) |
| Absorbance Range | 0.0000–4.0000 A |
| Measurement Modes | Single-, Dual-, and Multi-Wavelength |
| Built-in Oscillation | Adjustable speed & duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SU |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Wheat Flour Matrix |
| Wavelength | 538 nm |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 5.0–100.0 mg/kg |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Included | Sample Pretreatment Kit (1 set), Reagent Kit (50 assays) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-1400S |
| Function Type | Single-Analyte Immunoassay Platform |
| Sample Versatility | Multi-sample Compatible (Liquid Food Matrices) |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Linearity | ±1% (0.000–2.000 A) |
| Absorbance Measurement Range | 0.0000–4.0000 A |
| Plate Formats | Standard 96-well and 48-well microplates |
| Filter Positions | Fixed 405 nm, 450 nm, 492 nm, 630 nm + 4 configurable slots |
| Detection Methodology | Single-, Dual-, and Multi-wavelength ELISA photometry |
| Data Processing Algorithms | Linear, Semi-log, 4PL, 5PL, Polynomial, Parabolic, Spline Curve Fitting |
| Plate Shaking | Adjustable speed and duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-210SD |
| Function Type | Single-Analyte Detection System |
| Sample Compatibility | Multi-Matrix Food Samples |
| Detection Limit | 50.0 mg/kg |
| Quantification Range | 0.0–2000.0 mg/kg |
| Measurement Accuracy | ±5% (relative standard deviation under controlled conditions) |
| Control System | Embedded MCU-based platform |
| Data Interface | RS-232 and USB 2.0 |
| Display | Backlit LCD with Chinese UI |
| Portability | Handheld form factor, <1.2 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GDYQ-210SP |
| Price Range | USD 2,800–4,200 (FOB) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Design |
| Detection Range | 10.0%–50.0% (adulteration level) |
| Limit of Detection | 10.0% (adulteration level) |
| Power Supply | 220 V ±20 V, 50–60 Hz |
| Operating Ambient Temperature | 10–30 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-500M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Solid, Semi-solid, and Liquid Food Matrices |
| Detection Principles | UV-Vis Absorbance (Transmission/Reflection), Fluorescence Spectrometry |
| Wavelength Accuracy | ±5 nm |
| Wavelength Repeatability | ±1 nm |
| Detection Modes | Transmission, Reflectance, Fluorescence |
| Quantification Method | External Standard Calibration |
| Regulatory Compliance | GB/T 5009.28–2003, GB/T 5009.29–2003, GB/T 5009.35–2003, GB/T 5009.141–2003, GB 2760–2011 |
| Software | Dedicated PC-based Workstation with Chromatogram-like Peak Visualization, Automatic Integration, and Audit-Trail-Ready Data Export |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-6000S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Detection Wavelength | 400 nm |
| Detection Channels | 1 |
| Lower Detection Limit | 10.0 mg/kg |
| Quantification Range | 0.0–1000.0 mg/kg |
| Measurement Accuracy | ±2% |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-900M |
| Price Range | USD 7,000–14,000 (FOB) |
| Functionality | Multi-analyte (simultaneous detection of >20 food safety parameters) |
| Sample Versatility | Universal for solid, liquid, and semi-solid food matrices |
| Optical Detection Range | 495–530 nm |
| Repeatability | ≤ ±5% CV or ±5 RLUs |
| Detection Channels | 16 independent optical/analytical channels |
| Power Supply | AC/DC dual-mode |
| Display | 10.1" capacitive touchscreen, 1024 × 768 resolution |
| Data Storage | Internal SSD (≥64 GB) |
| Connectivity | Wi-Fi 802.11 b/g/n, Ethernet (RJ45), USB 2.0 × 2 |
| Output | Integrated thermal printer + external printer support via USB/Ethernet |
| Operating System | Windows Embedded Standard 7 |
| Software | Proprietary modular detection platform with remote OTA and local USB firmware update capability |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-901SC2 |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Wavelength | 538 nm |
| Detection Channels | 1 |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–200.0 mg/kg |
| Accuracy | ±2% |
| Regulatory Method | Modified GB/T 5009.33–2003 |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-RS1101 |
| Function Type | Single-parameter Moisture Determination |
| Sample Scope | Multi-sample Universal (Fresh Mammalian & Poultry Muscle Tissue) |
| Measurement Range | 65–85% w/w |
| Sampling Time | <1 s per acquisition |
| Output Interval | One result per 10 acquisitions or per single acquisition (configurable) |
| Accuracy (70–80% range) | ±1.0% w/w |
| Repeatability (70–80% range) | ≤0.5% w/w |
| Operating Temperature | 0–40 °C |
| Power Alert | Yes |
| Auto-shutdown | Yes |
| Data Storage | Onboard memory with total count display and recall |
| PC Connectivity | USB interface for data export and post-processing |
| Brand | JiDa-Xiaotianshen |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GDYQ-100CX |
| Price Range | USD 0–1,450 (est.) |
| Function Type | Multi-analyte (simultaneous detection of multiple food contaminants) |
| Sample Compatibility | Universal for solid and liquid food/ agricultural samples |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | MBS(Fitlylab) MBS-MR |
| Function Type | Multi-analyte Quantitative Microbial Detection |
| Sample Types | Solid, Liquid, Surface, Paste, Slurry |
| Wavelengths | Simultaneous Blue-Green-Red (450 nm, 530 nm, 630 nm) |
| Detection Time | 2–10× faster than conventional culture methods |
| Reproducibility | High (CV < 5% across replicate runs) |
| Detection Channels | 8 independent, temperature-controlled wells |
| Sensitivity | 1 CFU per test |
| Specificity | ≥99.999% |
| Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | MBS(Fitlylab) |
| Detection Channels | 8 |
| Wavelengths | Triple-wavelength (Blue, Green, Red) |
| Detection Time | 2–10× faster than conventional plate culture methods |
| Repeatability | High |
| Sample Types | Solid, liquid, surface swabs, pastes, slurries |
| Regulatory Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories), ISO/TR 13843:2000 (water quality — validation of microbiological methods) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Migration Cell |
| Quotation | Available Upon Request |
| Single-Side Contact Area | 0.05–2.0 dm² |
| Double-Side Contact Area | 0.1–4.0 dm² |
| Volume | 10–200 mL |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NX-300 |
| Function Type | Multi-analyte (Cd, Pb, As, Hg, Cr, etc.) |
| Sample Type Compatibility | Solid food matrices (rice, grains, flour, spices, infant formula, dried vegetables) |
| Detection Time | ≤3 min for screening |
| Power Supply | 220 VAC ±10%, 50/60 Hz, 1.5 A |
| Dimensions | 550 W × 330 D × 440 H mm |
| Weight | 30 kg |
| X-ray Source | Air-cooled microfocus X-ray tube |
| Detector | Fast Silicon Drift Detector (FastSDD) |
| Optical Path | Non-destructive, optimized beam collimation and scatter suppression architecture |
| Radiation Safety | Compliant with GBZ 115–2002 “Hygienic Protection Standard for X-ray Diffraction and Fluorescence Analyzers” |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1218CY |
| Function Type | Multi-analyte (Pesticide Residue Screening) |
| Sample Type | Single-sample dedicated platform |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Photometric Repeatability | ≤0.2% (T) |
| Optical Channels | 12 colorimetric + 3 colloidal gold lateral flow channels |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Dark Current Drift | ≤0.2% over 3 min |
| Measurement Accuracy | ±5% (vs. reference standards) |
| Display | 10.1″ capacitive touch LCD (1024×600), IP65-rated front panel, 400 cd/m² brightness |
| OS | Android 7.0, Quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage |
| Connectivity | Dual-band Wi-Fi, RJ45 Ethernet, Bluetooth 4.2, optional 3G/4G/5G module |
| Integrated Thermal Printer | Label & A4 report output |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1218LS |
| Function Type | Multi-analyte (Pesticide Residues, Mycotoxins, Heavy Metals) |
| Sample Compatibility | Universal for Grains and Cereals |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.2% T |
| Absorbance Repeatability | ≤0.3% |
| Optical Channels | 12 photometric + 3 colloidal gold (expandable to 10) |
| Display | 10.1″ TFT-LCD, 1024×600, IP65-rated front panel |
| Operating System | Android 7.0 (Quad-core, 1.8 GHz, 2 GB RAM, 16 GB storage) |
| Data Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Power Supply | AC 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1218NS |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte (Pesticide, Veterinary Drug, Mycotoxin & Heavy Metal Residues) |
| Sample Compatibility | Universal for Solid & Liquid Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% T |
| Absorbance Repeatability | ≤ 0.3% |
| Optical Channels | 12 photometric + 3 colloidal gold lateral flow readers |
| Display | 10.1″ capacitive touchscreen (Android OS) |
| Data Connectivity | Wi-Fi, RJ45 Ethernet, optional 4G LTE module |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218ZY |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% (T) |
| Optical Channels | 12 (spectrophotometric) + 3 (colloidal gold, expandable to 10) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Measurement Accuracy | ±5% |
| Display | 10.1-inch Android touchscreen |
| Connectivity | Dual USB, Wi-Fi, RJ45, optional 3G/4G/5G |
| Power Supply | 220 V ±10% AC |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1618NS |
| Function Type | Multi-analyte (pesticide, veterinary drug, mycotoxin & heavy metal residues) |
| Sample Compatibility | Universal for agricultural commodities (fruits, vegetables, grains, tea, aquatic products, livestock tissues, eggs) |
| Wavelength Range | 400–680 nm |
| Detection Time | ≤10 min per sample |
| Repeatability (CV) | <5% |
| Optical Channels | 12 independent photometric channels |
| Absorbance Range | 0.000–4.000 A |
| Absorbance Resolution | 0.001 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Dark Current Drift | ≤0.2% (3 min) |
| Measurement Accuracy | ±5% |
| Integrated Lateral Flow Immunoassay (LFIA) Module | 3 strips |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Data Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Storage | Internal high-capacity flash memory + dual USB ports |
| Database | Preloaded Chinese national standard sample library (>1,000 entries) with pinyin-based search |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-16ZD |
| Price Range | USD 7,000–14,000 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Applicability | Broad-spectrum for fruits, vegetables, and aqueous extracts |
| Wavelength Range | 380–680 nm (Primary Detection at 412 nm) |
| Assay Time per Sample Batch | ≤3 min |
| Photometric Repeatability | ≤0.3% CV |
| Detection Channels | 16 independent optical channels |
| Incubation Temperature Control | 37.0 °C ±0.5 °C |
| Operating System | Android-based embedded UI |
| Display | 7-inch capacitive color touchscreen |
| Data Storage Capacity | ≥10,000 assay records (1,000 visible on-screen) |
| Connectivity | Wi-Fi, dual USB 2.0 ports, RJ45 Ethernet |
| Power Supply | AC 220 V / DC 12 V |
| Net Weight | 7 kg |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-2418NS |
| Function Type | Multi-analyte (pesticide, veterinary drug & heavy metal residues) |
| Sample Compatibility | Universal for agricultural commodities |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.2% (T) |
| Optical Channels | 24 photometric + 3 colloidal gold immunochromatographic channels |
| Display | 10.1″ capacitive touchscreen (1024×600), IP65-rated front panel |
| OS | Android 7.0 (quad-core 1.8 GHz, 2 GB RAM, 16 GB storage) |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module, Bluetooth |
| Power Supply | 220 V ±10% AC |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Measurement Accuracy | ±5% (relative to reference standards) |
| Integrated Thermal Printer | Yes |
| Data Export | Cloud sync, USB, A4 report generation |
| Built-in Database | >1,000 standardized agricultural sample names per national standards (GB, NY) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | HYG-16 |
| Price | USD 6,300 (approx.) |
| Function Type | Multiplex Detection (≥5 targets per run) |
| Sample Compatibility | Universal for food matrices (liquid, homogenized tissue, swab eluates) |
| Excitation Wavelengths | 470 nm |
| Emission Wavelengths | 520 nm (FAM channel) |
| Detection Throughput | 16 wells (8×2 block), up to 14 samples + 2 controls per run |
| Cycle Time | ≤60 min (positive call in ≤15 min |
| Repeatability | ≤0.2% CV |
| Reaction Volume | 10–100 µL |
| Temperature Range | Ambient to 90 °C |
| Temperature Accuracy | ±0.4 °C |
| Temperature Uniformity | ±0.4 °C across block |
| Heating Rate | ≥1 °C/s |
| Thermal Lid | Integrated active pressure-controlled lid |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Dimensions | 300 × 260 × 150 mm |
| Net Weight | 4.0 kg |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HYG-16YB |
| Price | USD 16,500 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Animal Tissues, Blood, Oral Fluids, Swabs, and Processed Food Matrices (e.g., Dumpling Fillings) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤60 min (including nucleic acid extraction and amplification) |
| Repeatability | CV ≤0.2% |
| Detection Channels | 16 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JCX-04D |
| Function Type | Multi-analyte (28 target parameters) |
| Sample Compatibility | Solid & liquid food matrices (meat, dairy, grains, oils, condiments, aquatic products, spices) |
| Optical Range | 400–680 nm |
| Assay Time | <2 minutes per test |
| Repeatability | CV <5% |
| Detection Channels | Single-channel (sequential analysis) |
| Kit Contents | 28 pre-formulated rapid test reagents, calibrated portable instruments (pH meter, moisture analyzer, conductivity meter), supporting labware (aluminum case, digital balance, homogenizer, pipettes, timers, glassware) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JCX-105 |
| Price | USD 630 (FOB) |
| Function Type | Multi-analyte Screening Platform |
| Sample Compatibility | Universal for Liquid & Semi-solid Food Matrices |
| Optical Range | 400–680 nm |
| Assay Time per Test | <2 minutes |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 10 simultaneous visual/semi-quantitative assays |
| Kit Capacity | 14 validated food safety parameters with defined reagent yields |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JCX-3SL |
| Price | USD 495 (FOB Shanghai) |
| Function Type | Multi-analyte (Clenbuterol, Ractopamine, Salbutamol) |
| Sample Compatibility | Urine, animal tissue, feed |
| Wavelength Range | 400–680 nm |
| Detection Time per Test | <2 min (instrument-assisted readout) |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 3 |
| Sensitivity | Clenbuterol — urine (3 ppb), tissue (5 ppb), feed (10 ppb) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JCX-JC10 |
| Price | USD 495 (FOB Shanghai) |
| Function Type | Multi-analyte Screening System |
| Sample Compatibility | Liquid Alcoholic Beverages, Distillates, Blended Spirits, Fermented Liquors |
| Wavelength Range | 400–680 nm |
| Detection Time | <120 seconds per sample |
| Coefficient of Variation (CV) | <5% |
| Optical Channels | Single-beam photometric detection |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JCX-STWS10 |
| Price | USD 285 (FOB Shanghai) |
| Detection Capabilities | ATP bioluminescence (surface hygiene), anionic synthetic detergent residue (MBAS assay), food core temperature (–50 to 200 °C), storage/refrigeration temperature (–32 to 400 °C), free chlorine concentration (50–2000 mg/L as Cl₂) |
| Net Weight | 3.0 kg |
| Carry Case | Aluminum alloy portable case (350 × 270 × 110 mm) |