| Brand | EXPEC (Hangzhou Supeltech Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph with FID |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Preconcentration Method | Cryogenic Trapping & Direct Thermal Desorption |
| Sample Handling | Automated Whole-Air Sampling with Integrated Dehumidification and Enrichment |
| Compliance Context | Designed for continuous unattended operation in ambient air monitoring networks compliant with EPA TO-14/TO-15, ISO 16017-1, and China HJ 644–2013 standards |
| Software | Embedded real-time control with audit-trail-capable data acquisition supporting 21 CFR Part 11–compatible user authentication and electronic signatures |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Principle | GC-FID (Direct Method) |
| Sampling Method | Cryogenic Pre-concentration + Thermal Desorption |
| Sample Line Temperature | 120 °C (Heated Line) |
| Compliance | “Technical Specification for Continuous Automatic Monitoring of Non-Methane Hydrocarbons in Ambient Air (Trial)” (CNEMC-Air-2021-61) |
| Safety Features | Automatic H₂ Cut-off upon FID Flame-Out |
| Gas Control | Electronic Pressure Control (EPC) & Electronic Flow Control (EFC) |
| Surface Treatment | Deactivated (Inertized) Gas Pathways |
| Sample Handling | Back-Flush Function to Prevent High-Boiling Residue Carryover |
| Brand | EXPEC Technology |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 |
| Detection Principle | Dual-detector Gas Chromatography (FID + ECD) |
| Target Analytes | CO₂, CH₄, CO, N₂O, SF₆ |
| Compliance | GB/T 31705–2015 |
| Sample Introduction | Quantitative Loop Injection |
| Separation | Dedicated GHG Capillary Column |
| CO/CO₂ Conversion | Ni-Catalyzed Methanizer at Elevated Temperature |
| Detector Configuration | Simultaneous FID (for CH₄, CO-derived CH₄) and ECD (for N₂O, SF₆) |
| Data Output | Continuous Real-Time Concentration Profiles (ppb–ppm range) |
| Operational Mode | Unattended 24/7 Online Monitoring |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph |
| Detection Principle | GC-FID (Gas Chromatography with Flame Ionization Detection) |
| Explosion Protection | Ex d e ib px IIC T3/T4 Gb |
| Core Detector | Explosion-Proof FID |
| Sampling Method | High-Temperature Heated Probe + Heated Sample Line + Heated Pre-treatment Unit |
| Data Output | Real-time Temperature, Pressure, Flow Rate, Humidity, O₂ Content, NMHC, Benzene, Toluene, Ethylbenzene, Xylenes (BTEX) |
| Compliance | Designed for EPA Method 25A / ISO 12039 / HJ 1012-2018 Environments |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Ambient | –10 °C to +50 °C |
| Enclosure Rating | IP65 |
| Brand | EXPEC / Superspec |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Configurability | FID, MSD, or PID Detectors |
| Target Analytes | Methane / NMHC, BTEX, Methanol, Acetone, and >100 Volatile Organic Compounds |
| Sampling Line Material | Stainless Steel or PTFE Low-Adsorption Tubing |
| Software Interface | Localized Chinese GUI with Audit-Trail-Capable Control Platform |
| Footprint | ≥1 m² (Modular Cabinet Design, Indoor/Outdoor Deployment Options) |
| Compliance | GB/T 38394–2019, HJ 1012–2018, HJ 759–2015 |
| Brand | EXPEC / Puyu Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Methods | UV Fluorescence (H₂S), Chemiluminescence (NH₃), GC-NPD (methylamine, dimethylamine, trimethylamine), GC-FPD (methanethiol, methyl sulfide, carbon disulfide, dimethyl disulfide), GC-FID (styrene) |
| Detection Limit | As low as 0.1 ppb for selected compounds |
| Cabinet Format | 19-inch standard rack-mount enclosure |
| Compliance | Aligned with GB 14554–2018 (Draft Revision), HJ 1227–2021, and related Chinese environmental monitoring standards |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3050 |
| Instrument Type | Portable Gas Chromatograph with Integrated FID |
| Weight | ~2.0 kg |
| Compliance | GB 37822–2019, HJ 733–2014, HJ 1019–2019 |
| Optional Configuration | FID + PID dual-detector mode |
| Power Supply | Rechargeable Li-ion battery (operational runtime ≥ 4 h) |
| Detection Principle | Catalytic combustion-assisted flame ionization detection |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3100 |
| Instrument Type | Portable Gas Chromatograph with Flame Ionization and Photoionization Detectors |
| Compliance | GB 37822–2019, HJ 733–2014, HJ 1019–2019 |
| Weight | 3.7 kg |
| Response Time | < 3.5 s (FID/PID) |
| Detector Options | FID (standard), PID (optional) |
| Explosion Protection | Intrinsically Safe (handheld controller), Flameproof (FID module), Certified for Class I, Division 1 hazardous locations |
| Brand | EXPEC/Spectrum Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 3200 |
| Instrument Type | Portable Gas Chromatograph |
| Detection Principle | High-Temperature Catalytic Oxidation + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for THC/Methane/NMHC |
| Compliance | HJ 1012–2018, Local NMHC Field Monitoring Standards (Beijing, Tianjin, Shandong, Fujian, Jiangxi, Henan) |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | GC 2000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Electronic Pressure Control (EPC) | Up to 6 modules, controlling up to 18 gas channels |
| EPC Precision | 0.001 psi |
| Sample Path Surface Treatment | Ultra-inert deactivation for N/O/S/P-containing compounds |
| Operating System | Android-based open platform with touch interface |
| Software | Legacy-compatible workstation with sequence/method editing, real-time chromatogram display, multi-sample statistical comparison and trend visualization |
| Compliance Support | Designed for GLP/GMP environments |
| [Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | GC9720PLUS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified (Contact for Details) |
| Oven Ramp Rate | Not Specified (Contact for Details) |
| Oven Cool-Down Rate | Not Specified (Contact for Details) |
| Carrier Gas Flow Range & Control | Not Specified (Contact for Details) |
| Carrier Gas Pressure Range & Control | Not Specified (Contact for Details) |
| Injector Maximum Operating Temperature | Not Specified (Contact for Details) |
| Injector Pressure Setting Range | Not Specified (Contact for Details) |
| Injector Total Flow Setting Range | Not Specified (Contact for Details)] |
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F70Pro |
| Application Scope | General-Purpose Analysis |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F80 |
| Application Scope | General-Purpose |
| EPC Generation | 4th-Generation Electronic Pressure Control (EPC) |
| Column Oven Design | Platinum Resistance Temperature Sensor with Unobstructed Mounting |
| Safety Features | Dual-Temperature Monitoring, Hydrogen Auto-Shutoff, DC Heating, Flame-Retardant Materials |
| Detector Options | Multiple Configurable Detectors |
| Flow Path Flexibility | Multi-Valve/Multi-Column Support, Deans Switch, Micro-Flow Center-Cut, Comprehensive 2D-GC Ready |
| Software Platform | MyLab Chromatography Workstation (Web-Based Remote Access via PC/Tablet/Smartphone) |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable Gas Chromatograph |
| Application Scope | General-purpose Environmental Emission Monitoring |
| Compliance Standards | HJ 1012, HJ 38, HJ 604, GB 37822–2019 |
| Detection Principle | High-Temperature Heated Sample Transfer + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for Total Hydrocarbons, Methane, and BTEX |
| Integrated Power Supply | Rechargeable Lithium Battery (≥4 h continuous operation with heated line) |
| Data Output | Raw Chromatograms & Quantitative Results Exportable in Standard Formats (e.g., .csv, .cdf) |
| Certification | China Metrology Accreditation (CPA), Compatible with CMA Reporting Requirements |
| Sample Introduction | Dual-Stage Filtered Sampling Pump + Fixed-Volume Loop Injection |
| Column Configuration | Capillary GC Column Optimized for C1–C8 Hydrocarbons |
| Detector Temperature | Up to 180 °C |
| Sample Line Temperature | Heated to 180 °C |
| Dimensions & Portability | Integrated All-in-One Chassis with Carrying Handle |
| Optional Accessories | Android Tablet Interface, High-Pressure Gas Cylinders, Metal Hydride Hydrogen Generators |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-2000 Universal |
| Application Scope | General-Purpose Analytical Chemistry |
| Control Interface | Full-Touch Color LCD Display |
| Pneumatic Control | Electronic Pressure and Flow Control (EPC) |
| Software Architecture | Modular Workstation with Method-Driven Workflow |
| Microfluidic Capability | Valveless Flow Switching for Column Back-Flush, Detector Selection, and GC-MS Parallel Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector Options | FID, FPD |
| Control Interface | 7-inch TFT capacitive touchscreen |
| Gas Control | Mechanical valves with electronic pressure & flow monitoring |
| Column Oven | Dual-sensor temperature monitoring, thermal fuse protection, flame-retardant materials (UL94 V-0 rated) |
| Compliance | Designed to support GLP/GMP workflows, ASTM D3606/D1319, ISO 17025-aligned operation |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Control Architecture | Dual-AFC (Carrier Gas & Detector Auxiliary Gas) or Full-AFC Mode |
| Detection Systems | FID, FPD (Wide-Range Configurable) |
| Injection Options | Multiple Configurable Inlet Types |
| Software Platforms | FL97Plus, MyLab Chromatography Data Systems (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows with audit trail-ready CDS options |
| Human-Machine Interface | 7-inch capacitive touchscreen with real-time multi-channel status visualization |
| Maintenance Intelligence | Consumables tracking (septa, liner, split cold trap), usage-based alerts, and automated leak-check protocol |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GM Explosion-Proof Enclosure |
| Price Range | USD 70,000 – 140,000 |
| Instrument Type | External Protective Enclosure for Portable Gas Chromatographs |
| Application Scope | General-Purpose Hazardous Area Deployment |
| Explosion Protection Rating | Exdp II BT1 to Exdp II CT6 (GB 3836 Compliant) |
| IP Rating | IP65 |
| Internal Pressure Range | 30–100 Pa |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Construction Materials | EP-grade stainless steel tubing (welded or VCR-fitted) |
| Viewing Window | Shatter-resistant explosion-proof borosilicate glass |
| Certification Basis | GB 3836.1–2010, GB 3836.5–2017 |
| Brand | Huazhun Chromatography |
|---|---|
| Model | GC-2021plus |
| Origin | Jiangxi, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 5 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | ≤8 min (from 350 °C to 50 °C at 25 °C ambient) |
| Carrier Gas Flow Control Range | 0–200 mL/min (N₂), 0–1250 mL/min (H₂ or He) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (0–150 psi) |
| Injector Maximum Operating Temperature | 420 °C |
| [Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GC-7890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +5°C to 450°C (adjustable in 0.1°C increments) |
| Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 450°C → 50°C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability (≤180°C) | ±0.01°C |
| Column Configuration Support | Dual packed columns + one capillary column, or dual capillary columns |
| Detector Compatibility | Dual TCD, dual FID, or simultaneous TCD/FID operation |
| Programmed Temperature | 8-step ramping across 6 independently controlled zones |
| Auto-Ignition | Yes (patented) |
| Automatic Sample Injection | Yes (patented) |
| Power Supply | 220 V ±10%, 2200 W max |
| FID Sensitivity | ≤3×10⁻¹² g/s (benzene on CS₂), Noise: ≤3×10⁻¹³ A, Drift: ≤5×10⁻¹³ A/30 min, Linearity: ≥10⁶] |
| [Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-HD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–800 mL/min] |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | TP101 |
| Application Scope | General-Purpose |
| Carrier Gas | Nitrogen (standard configuration) |
| Detection Principle | Partition/Adsorption Equilibrium in Gas-Solid or Gas-Liquid Systems |
| Column Compatibility | Capillary and Packed Columns |
| Operating Mode | Temperature-Programmed and Isothermal Elution |
| Detection Systems Supported | FID, TCD (configurable per application) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | BJ-GC128 |
| Price | USD 22,000 (FOB Guangdong) |
| Touchscreen | 7-inch color capacitive display |
| Control Architecture | Dual-mode—embedded real-time OS + PC-based bidirectional software control |
| EFC/EPC | Electronic Flow Control / Electronic Pressure Control on all inlets and detectors |
| Inlet Zones | 2 independently heated (up to 400 °C), compatible with packed columns (φ3/φ4) and split/splitless capillary inlets |
| Detector Options | FID (MDL ≤ 2.5×10⁻¹² g/s n-hexadecane, dynamic range 10⁷), TCD (sensitivity ≥ 5000 mV·mL/mg n-hexadecane, baseline drift ≤ 0.15 mV/30 min), ECD (⁶³Ni source, MDL ≤ 80 fg/s, γ-HCH ≤ 8×10⁻¹⁴ g/mL, dynamic range 10³), FPD (P: MDL ≤ 2×10⁻¹² g/s, S: ≤ 4×10⁻¹¹ g/s, methyl parathion, P/S dynamic range 10³/10²) |
| Oven Specifications | Internal dimensions 280 × 310 × 160 mm |
| operating range | ambient +4 °C to 420 °C |
| Auxiliary Heaters | 2 additional zones (max 400 °C) |
| External Event Ports | 8 TTL-compatible digital I/O channels for valve sequencing, autosampler triggering, or thermal desorption synchronization |
| Connectivity | RS-232 serial port, LAN (LAM protocol), 20 method storage slots |
| Safety Features | Automatic oven fan & heater shutdown upon column chamber door opening |
| Power Requirements | 220 VAC ±10%, 50/60 Hz, 3000 W max |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic HPLC System |
| Model | GB-LC01 |
| Price Range | USD 1,400 – 4,200 |
| Instrument Type | Laboratory-Scale Analytical & Semi-Preparative HPLC System |
| Primary Application Field | Food Safety & Quality Control |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | GC-9802 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 μm film thickness), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (optional packed column inlet) |
| Oven Dimensions | 240 × 210 × 240 mm (W × D × H) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Carrier Gases | High-purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), clean oil-free air (0.4 MPa, dry) |
| Gas Line Interface | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GC-9802-A |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific Analysis |
| Oven Temperature Range | Up to 400 °C |
| Ramp Rate | 0–40 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Detector | FID (Hydrogen Flame Ionization Detector), Optional TCD/ECD/NPD |
| FID Sensitivity | Mt ≤ 1 × 10⁻¹¹ g/s (n-Hexadecane) |
| Baseline Drift | ≤ 0.02 mV/h |
| Noise | ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (Optional Packed Column Injector) |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±0.1% of setpoint |
| Carrier Gas | High-Purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), Clean Air (0.4 MPa, oil-free, particle-free) |
| Gas Line Connection | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |