Gas Chromatograph
Filter
Showing 241–270 of 583 results
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HQX-101 |
| Price Range | USD 7,000–14,000 (FOB Beijing) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-Down Rate | 0.1–40 °C/min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | Up to 5 MPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | Atmospheric (constant-pressure mode) |
| Injector Total Flow Setting Range | Up to 200 mL/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | HQX-2010 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Temperature Control Accuracy | Better than ±0.1 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Maximum Injector Temperature | 450 °C |
| Injector Temperature Setpoint Range | 5 °C above ambient to 450 °C |
| Injector Total Flow Setting Range | 5 °C above ambient to 450 °C |
| Number of Independent Temperature Zones | 6 |
| Programmed Temperature Ramps | 8-step |
| Column Compatibility | Capillary (including 0.53 mm ID) and Packed Columns |
| Injector Configurations | Dual or triple inlet options (gas/liquid), optional six-port valve and methanizer support |
| Detector Support | Multiple detector modules (FID, TCD, ECD, FPD — detector-specific specs not provided) |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HF-901A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-Down Rate | 350 °C → 50 °C in <5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Zones | 8 independent zones with over-temperature protection |
| Display | 7-inch industrial color LCD touchscreen |
| Language Support | English & Chinese |
| Programmed Temperature Ramping | Up to 16 steps (expandable) |
| Maximum Run Time | 999.99 min |
| Injection Modes | Split/splitless capillary, packed column, valve injection, auto liquid/gas sampling |
| Detector Capacity | Up to 4 detectors simultaneously |
| Supported Detectors | FID, TCD, ECD, FPD, NPD, PDHID, PED |
| FID Detection Limit | ≤3.0×10⁻¹² g/s (n-hexadecane in iso-octane) |
| FID Linear Dynamic Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene/toluene) |
| TCD Linear Dynamic Range | ≥10⁵ |
| FPD Detection Limits | S ≤2×10⁻¹¹ g/s, P ≤1×10⁻¹² g/s (methyl parathion) |
| ECD Detection Limit | ≤1.0×10⁻¹⁴ g/mL (γ-HCH) |
| NPD Detection Limits | N ≤1.0×10⁻¹² g/s (azobenzene), P ≤1.0×10⁻¹² g/s (malathion) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-1860 |
| Temperature Control Range | 8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed) |
| Cooling Rate | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1860Ⅱ |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–300 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–300 kPa |
| Injector Total Flow Setting Range | 200 mL/min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1860III |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Oven Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–300 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–300 kPa |
| Injector Total Flow Setpoint Range | 200 mL/min |
| Temperature Zones | 6 independent zones |
| Max Programmed Temperature Steps | 16 |
| Max Ramp Rate (with auxiliary heating) | 80 °C/min |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously) |
| Electronic Pressure Control (EPC) | Yes, dual-mode (constant pressure / constant flow) |
| Supported Gases | N₂, H₂, Air, He, Ar |
| Communication Interface | 10/100 M Adaptive Ethernet with embedded TCP/IP stack |
| Modbus/TCP & Profibus-DP Protocol Support | Yes |
| Software | STI-netChrom (supports up to 253 instruments, DCS integration via built-in Modbus/TCP server) |
| Display | Vacuum Fluorescent Display (VFD), bilingual (English/Chinese) |
| Auto-Start Scheduling | Yes |
| Auto-sampler Interface | Standard RS-232 and TTL trigger support |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 0–399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 30 °C/min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Detection Limit (FID) | ≤1×10⁻¹¹ g/s |
| Baseline Noise (FID) | ≤5×10⁻¹⁴ A |
| Drift (FID) | ≤1×10⁻¹³ A/30 min |
| Linear Dynamic Range | ≥10⁶ |
| Programmable Temperature Steps | 8-stage |
| Relative Humidity Limit | ≤85% |
| Operating Ambient Temperature | +5 °C to +35 °C |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz, 10 A |
| Power Consumption | ≤1500 W |
| Dimensions (H×W×D) | 490×730×490 mm |
| Net Weight | ~48 kg |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HP 5890 Series II |
| Detection Options | FID / TCD |
| Injection Options | SSI / PPI |
| Data System | Integrated GC Control & Analysis Software |
| Autosampler | HP 7673 |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9100 |
| Temperature Control Range | Ambient +20 °C to 400 °C (oven, inlet, detector) |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Display | Color LCD with bilingual (English/Chinese) UI |
| Control Interface | PC-based software with remote operation capability |
| Automation Interfaces | Built-in driver support for autosamplers, thermal desorbers, purge-and-trap systems |
| Safety Features | Auto flame ignition, flame-out detection & re-ignition, gas leak protection, automatic gas-line initialization |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Oven Temperature Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard Mode) |
| Oven Cool-Down Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FID Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane in iso-octane) |
| FID Baseline Noise | ≤5×10⁻¹⁴ A |
| FID Baseline Drift | ≤1×10⁻¹³ A/30 min |
| FID Linear Dynamic Range | ≥10⁶ |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Oven Temperature Range | Ambient + 20 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Time | ≤5 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Temperature Range | Ambient + 20 °C to 400 °C |
| TCD Sensitivity | ≥5000 mV·mL/mg (n-heptane) |
| FID Detection Limit | <8×10⁻¹² g/s (n-decane) |
| NPD Detection Limits | ≤1×10⁻¹² g/s (N), ≤1×10⁻¹³ g/s (P) |
| FPD Detection Limits | ≤8×10⁻¹¹ g/s (S), ≤4×10⁻¹² g/s (P) |
| Column Compatibility | Packed columns (2–4 mm ID), Capillary columns (0.1–0.53 mm ID), Including Wide-Bore (0.53 mm) Systems |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-Universal Series |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient + 4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (Standard) |
| Cool-Down Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Programmable Steps | 16-stage |
| Hold Time per Step | 0–655 min |
| TCD Sensitivity | ≥5000 mV·mL/mg |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-decane) |
| ECD Detection Limit | ≤1×10⁻¹³ g/s (γ-BHC) |
| FPD Detection Limit | ≤5×10⁻¹³ g/s (S), ≤1.4×10⁻¹³ g/s (P) |
| NPD Detection Limit | ≤5×10⁻¹³ g/s (N) |
| Power Supply | 220 V ±10% AC, 50 ±0.5 Hz |
| Max Power Consumption | ≤1500 W |
| Dimensions (L×W×H) | 628 × 465 × 460 mm |
| Weight | 50 kg |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Time | ~6 minutes (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Solvent Residue GC for Plastic Flexible Packaging |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific |
| Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | ~6 min (400°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | Refinery Gas-Specific GC |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD and FID |
| Column Types | Packed and Capillary |
| Multi-Valve Auto-Switching | Yes |
| Signal Auto-Switching | Yes |
| Analysis Scope | H₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Solvent Residue Analysis in Edible Oils, Food Additives, and Pesticide Residues |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column Compatibility | Capillary columns for volatile organic solvent separation (e.g., DB-VRX, HP-PONA, or equivalent polar/non-polar GC columns) |
| Data System | Integrated GC workstation with peak integration, calibration curve generation, and audit-trail-capable reporting |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Solvent Residue-Specific Gas Chromatograph |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Laboratory-Grade Gas Chromatograph |
| Primary Application Domain | Food Packaging Safety Testing |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column | Pre-configured Capillary Column for Volatile Organic Solvent Separation |
| Data System | Integrated Chromatography Workstation with Audit Trail Capability |
| Required Gases | High-Purity Nitrogen (carrier), Hydrogen (detector fuel), and Compressed Air (detector oxidant) |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis (Specialized for Kr, He, Ne, Xe, Ar) |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate (350 °C → 50 °C) | ≤8 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Limit (for N₂, O₂, CH₄, CO, CO₂, H₂, H₂O, CF₄) | ≤5 ppb (v/v) |
| Detector Type | High-Sensitivity Helium Ionization Detector (HID) |
| Column Configuration | Multi-Column Oven with Independent Temperature Zones |
| Sample Introduction | Dual-Channel Valve System with Purge-Protected Switching Valves |
| Flow Compensation | Automatic Inlet Pressure Correction Algorithm for Variable Base-Gas Matrices |
| Compliance Reference | GB/T 5829–2006 (Krypton Specification), GB/T 28123–2011 (High-Purity Noble Gases), ASTM D7606–22 (Trace Impurity Analysis in Ultra-High-Purity Gases) |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-PDD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Dedicated High-Purity & Electronic Specialty Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | ~7 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–500 psi |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-9560-HD DGA System |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Power Industry–Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Column Oven Cooling Time | <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399 °C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detection Limits (as per DL/T 703–1999) | H₂ <2 µL/L, O₂ <5 µL/L, N₂ <5 µL/L, CO <2 µL/L, CO₂ <2 µL/L, Hydrocarbons <0.1 µL/L |
| Temperature Stability | ±0.1 °C across all zones (oven, injector, detectors, methanizer) |
| Detectors | Dual-channel TCD and FID with Ni-catalyst methanizer |
| Column Configuration | Parallel dual-column gas separation path |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560-HM |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Temperature Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~50 °C in ≤7 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Dimensions | 315 × 300 × 195 mm |
| Temperature Control Precision | ±0.1 °C (six independent zones) |
| Programmed Temperature Ramping | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| Detector | TCD (Thermal Conductivity Detector), dual-channel, rhenium-tungsten filament, constant-current operation |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane/isooctane) |
| Baseline Noise | ≤15 μV |
| Baseline Drift | ≤100 μV/30 min |
| Linearity | ≥10⁴ |
| Compliance | GB 10410–1989 |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HA-9660-PDD |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8°C above ambient to 400°C |
| Ramp Rate | 1–40°C/min |
| Cool-down Rate | 400°C to 50°C in 7 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min (electronic monitoring) |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa (8-step setting) |
| Injector Max Temp | 400°C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detector | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Detection Limit | ≤5 ppb |
| Drift/Repeatability | ±1%–±5% |
| Sample Gas Flow | 50 mL/min |
| Sample Gas Pressure | 0.1 MPa |
| Sample Inlet | 1/4″ Swagelok SS |
| Carrier Gas | He |
| Carrier Inlet | 1/8″ Swagelok SS |
| Display | LED |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 400 W |
| Weight | 20 kg |
| Dimensions | 482 mm (W) × 222 mm (H) × 400 mm (D), 5U rack-mountable |
| Communication Interface | RS-232 / RS-485 |
| Protocol | Modbus |
| Brand | Huai Chromatography |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9560-HC |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 350→50 °C in ≤8 min |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Limit (H₂ matrix, TCD) | O₂/N₂/CO/CH₄/CO₂ ≤ 0.1–2 ppm (3 mL sample) |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petrochemical & Electronic Specialty Gases |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Oven Cooling Time | <5 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~7 min (350 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Precision | ±0.1 °C |
| Programmed Temperature Steps | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (n-hexadecane / isooctane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Drift | ≤2×10⁻¹² A/30 min |
| FID Linearity | ≥10⁶ |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane / isooctane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV/30 min |
| TCD Linearity | ≥10⁴ |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ± 22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC-9560-EG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) and Electronic Grade (EG) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C in ~7 min |
| Carrier Gas Flow Control Range | 0–400 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–400 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | GC-9560-HB |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~7 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~50 °C in ≈7 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-HG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Heating Rate | 1–40 °C/min |
| Cooling Rate | ~7 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization (PDHID) |
| Detection Limit | ≤1.0×10⁻¹⁰ g/mL (for organic compounds) |
| H₂ | 5 ppb, O₂/Ar: 10 ppb, N₂: 10 ppb, CH₄: 5 ppb, CO: 25 ppb, CO₂: 5 ppb |
| Temperature Control Precision | ±0.1 °C (eight independent zones) |
| Programmed Temperature Ramping | 8-step |
| Data Acquisition | 20 Hz, 24-bit A/D, dynamic range 10⁶ |
| Compliance | GB/T 28726–2012, GB/T 3634.2–2011, GB/T 14599–2008, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844–2011, GB/T 17873–1999, GB/T 5829–2006, GB/T 5828–2006, HG/T 3633–1999, GB 10621–2006, GB/T 23938–2009, GB/T 28125.1–2011 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9560-HQ |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~7 minutes from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |