Gas Chromatograph
Filter
Showing 541–570 of 614 results
| Brand | SRI |
|---|---|
| Origin | USA |
| Model Variants | 110, 310, 410, 8610C, 8610D |
| Configuration | Benchtop or Portable Chassis Options |
| Detectors | FID, TCD, SCD, PID (User-Selectable) |
| Compliance | ASTM D1945, D1946, D3588, ISO 8573-5, USP <467>, EPA Method TO-14A/TO-15 |
| Data System | Standalone PC-Based Acquisition & Processing Software (No Dedicated Terminal Required) |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | SRI-8610C |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (programmable) |
| Cool-down Time | ~15 min (400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Control | 0–80 psi (EPC-programmable) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmable) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Pesticide Residue Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cooling Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Range | Adjustable (EPC-controlled) |
| Carrier Gas Pressure Range | 0–80 psi (programmable EPC) |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmed) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Routine Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cool-down Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Range & Control | 0–80 psi, program-controlled via EPC |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi, fully programmable |
| Injector Total Flow Setpoint Range | Electronically adjustable |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | GC1120 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC1120 NMHC-Dedicated Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-Made) |
| Model | GC1290 |
| Instrument Category | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5°C to 420°C |
| Ramp Rate | 0–80°C/min |
| Cool-Down Time | <2.5 min (from 350°C to 100°C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 420°C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–250 µL/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose (Benzene-Series & TVOC Analysis) |
| Oven Temperature Range | 5°C above ambient to 400°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Rate | 50°C/min |
| Injector Maximum Operating Temperature | 400°C |
| Detector | Photoionization Detector (PID) |
| Benzene LOD | 1 ppb |
| Flow Monitoring | Digital Electronic Pressure & Flow Display |
| Software | TVOC-Specific Reverse-Controlled Workstation with Automated Quantitation & Reporting |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | 5 °C above ambient to 400 °C |
| Ramp Rate | 0.1–39 °C/min |
| Cooling Rate | 50 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Programmable Temperature Ramping | 9-step |
| Column | Specified NMHC Separation Column (O₂/CH₄ Resolution Optimized) |
| Detector Options | FID, TCD, ECD, FPD, NPD, PID, Micro-TCD |
| Simultaneous Detector Capacity | Up to 3 |
| Analog Outputs | 3 channels |
| Digital Output | 1 RS-232/USB port |
| Display | Large Backlit LCD with Real-Time Dual-Chromatogram View |
| Control Interface | Touch-Sensitive Keypad |
| Electronic Pressure Control (EPC) | Optional for Split/Splitless Inlet |
| Septum Purge | Integrated for Ghost Peak Suppression |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Oven Temperature Range | 5 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Oven Cooling Rate | 50 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Programmable Temperature Ramping | 9-Step |
| Injector Configurations | Up to 3 simultaneous inlets (Split/Splitless with septum purge, Packed Column, and Optional Capillary Inlet) |
| Detector Capacity | Up to 3 detectors installed concurrently |
| Detector Options | FID, TCD, ECD, FPD, NPD, PID, Micro-TCD |
| Signal Outputs | 3 analog channels + 1 digital interface (RS-232/USB) |
| User Interface | Touch-sensitive keypad with large LCD display supporting dual real-time chromatogram overlay |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 5 °C above ambient to 420 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Cool-Down Performance | 350 °C to 50 °C in ≤5 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min (EPC) |
| Carrier Gas Pressure Range & Control | 0–100 psi (EPC) |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–100 psi (EPC) |
| Injector Total Flow Setting Range | 0–100 mL/min (EPC) |
| Electronic Pressure Control Channels | Up to 18 independent gas channels |
| Independent Temperature Zones | 10 |
| Injector Configurations Supported | Up to 3 (including packed-column, split/splitless capillary) |
| Signal Outputs | 3 digital + 3 analog + optional 4th detector interface |
| Method Storage Capacity | 9 methods onboard |
| Power Input Compatibility | 100–240 V AC, 50/60 Hz |
| External Event Inputs | 4 isolated TTL-compatible channels |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Carrier Gas Flow Control Range | 0–1500 mL/min |
| Carrier Gas Pressure Control Range | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC7980Plus |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-Down Rate | 0.1–80 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Electronic Pressure Control (EPC) Precision | ±0.001 psi |
| Detector | High-Sensitivity Flame Ionization Detector (FID) with Ceramic Jet |
| Injector Configuration | Modular Split/Splitless Injector |
| Software | CompassCDS Chromatography Data System (CDS), FDA 21 CFR Part 11 Compliant |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo Fisher Corona CAD |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Trace 1600 & 1610 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +3 °C to 450 °C |
| Maximum Ramp Rate | 125 °C/min |
| Cooling Rate | <4 minutes from 450 °C to 50 °C |
| Injector Maximum Operating Temperature | 450 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | Trace 1600 & 1610 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +3°C to 450°C |
| Maximum Ramp Rate | 125°C/min |
| Cooling Rate | <4 minutes from 450°C to 50°C |
| Module Interchangeability | Yes |
| Helium Conservation Mode | Enabled |
| Power Consumption | Optimized for low operational load |
| Dimensions | Compact benchtop footprint |
| User Interface | 7-inch icon-driven capacitive touchscreen with embedded video-guided maintenance workflows |
| Column Installation | iConnect Column Lock (tool-free), integrated column oven lighting |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | TSQ 9610 Triple Quadrupole GC-MS/MS System |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | ISQ 7610 Single Quadrupole GC-MS |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Pricing Range | USD 65,000 – 130,000 (FOB US Port) |
| Module Architecture | Plug-and-Play, User-Replaceable Inlet & Detector Modules |
| Compliance | Designed to support GLP/GMP workflows and 21 CFR Part 11–compliant data integrity requirements |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Module Architecture | Plug-and-Play, User-Replaceable Inlet and Detector Modules |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TRACE 1300E |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 125 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Inlet Maximum Operating Temperature | Not specified (standard SSL inlet rated to 450 °C) |
| Inlet Pressure Setting Range | 0–1000 kPa |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | TRACE 1300E |
| Price Range | USD 135,000 – 205,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Fields | Chemical Analysis, Petrochemical Analysis, Environmental Testing, Food & Flavor Analysis, Pharmaceutical QC |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TRACE 1300E |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 125 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Inlet Maximum Operating Temperature | Not Specified (Configurable per Inlet Type) |
| Inlet Pressure Setting Range | 0–1000 kPa |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | TRACE™ 1300E |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | General-purpose |
| Temperature Control Range | Ambient to 450 °C |
| Maximum Ramp Rate | 125 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Inlet Pressure Setting Range | 0–1000 kPa |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Cooling Rate | Not specified |
| Inlet Maximum Operating Temperature | Not specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TRACE 1310 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +3 °C to 450 °C |
| Injector Maximum Operating Temperature | 450 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | TRACE 1310 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | +3°C to 450°C |
| Injector Maximum Temperature | 450°C |
| Modular Detector/Injector Hot-Swap Capability | Tool-free, <2 min per module |
| Software Platform | Thermo Scientific Dionex Chromeleon CDS |
| Compliance Support | 21 CFR Part 11 (with audit trail enabled), GLP/GMP-ready configuration options |
| Detector Compatibility | FID, TCD, ECD, NPD, FPD, GC-MS interfaces (ISQ, TSQ series, DFS, Delta V) |
| Autosampler Compatibility | TriPlus RSH, TriPlus 300, TriPlus 100 LS, AI/AS 1310 |
| Optional Features | Backflush, Low Thermal Mass (LTM) injectors/detectors, Helium Conservation Module, PTV and SSL inlets |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TRACE 1600 Series |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRACE™ 1600 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Cool-Down Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | TRACE™ 1600 Series GC |
| Pricing | Available upon Request |
| Column Oven Cooling Time | ≤4 min (450°C → 50°C) |
| Heating Rate | Up to 90°C/min |
| Temperature Range | Ambient +3°C to 450°C (optional sub-ambient operation) |
| Power Supply | 120 V |
| Compliance | Machinery Directive 2006/42/EC, Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC |
| Dimensions (L × W × H) | 45 × 44 × 67 cm |
| Inlet Options | SSL, PTV, SSL-BKF, PTV-BKF, COC, GSV (up to 2) |
| Detector Options | FID, TCD, ECD, NPD, FPD, PDD, MS-compatible (up to 2) |
| iConnect™ Module Architecture | Tool-free inlet/detector swapping, column locking, offline maintenance capability |