Gene Sequencer
Filter
Showing 1–30 of 36 results
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3130xl |
| Instrument Type | First-Generation Sanger Sequencer |
| Category | Capillary Electrophoresis–Based DNA Sequencing System |
| Regulatory Designation | Import-Class Life Science Instrument |
| Vendor Status | Authorized Refurbishment & Distribution Partner |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-NGS 180S |
| Sample Throughput | 8–24 samples per run (full automation) |
| Pipetting Channels | 24-channel adjustable (1/8/16/24-channel modes) |
| Pipetting Range | 0.5–200 µL |
| Accuracy (A) | ±10% at 0.5 µL, ±2% at 20 µL, ±1% at 100/200 µL |
| Precision (CV) | ≤5% at 0.5 µL, ≤2% at 20 µL, ≤1% at 100/200 µL |
| Minimum Sample Volume for Fluorometric Quantification | 2 µL |
| dsDNA Detection Limit | 0.4 ng |
| Fluorescence Module | 24-well integrated fluorometer, CV ≤1.5% repeatability |
| Thermal Modules | Dual 4–105 °C refrigeration units (±0.5 °C accuracy/uniformity), one heating module (RT–105 °C), one heating-shaking module (RT–105 °C, 200–3000 RPM, 2 mm orbit), one PCR thermal cycler (block: 4–99 °C, lid: 30–120 °C, uniformity ±0.7 °C, accuracy ≤±0.3 °C) |
| Magnetic Bead Purification | 96-well circular magnetic stand (compatible with PCR/deep-well plates) |
| Tip Capacity | Up to 10 tip boxes (6 single-layer + 2 double-layer positions) |
| Brand | Anxuyuan |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AxiLona AXP-100 |
| Instrument Type | Third-Generation Sequencer |
| Medical Device Classification | Non-Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 1–100 kbp |
| Sample Input Requirement | ≥100 ng |
| Throughput | ≤100 Gb per run |
| Base Call Quality | >80% of bases ≥ Q20 |
| Raw Read Accuracy | 99.2% |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 3730xl |
| Instrument Type | First-Generation Capillary Electrophoresis DNA Sequencer |
| Read Length Range | 400–600 bp |
| Throughput | 768–3,936 reads/day |
| Detection Accuracy | 99.99% |
| Reproducibility | 90% |
| Run Frequency | 8–72 runs/day |
| Capillary Array Compatibility | 48- and 96-capillary formats |
| Laser Source | 505 nm solid-state laser |
| Temperature Control Range | 18–70 °C |
| Polymer System | POP-7™ polymer |
| Dye Capacity | Up to 6-color detection |
| Unattended Operation | Up to 48 hours |
| Integrated Barcode Reader | Yes |
| Onboard Plate Piercing | Yes |
| Automated Base Calling & Quality Value (QV) Scoring | Yes |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 3500/XL |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Category | Imported |
| Distributor Type | Authorized Third-Party Reseller |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3100 |
| Instrument Type | First-Generation Capillary Electrophoresis Sequencer |
| Sample Throughput | Up to 768 samples per unattended run (2 × 384-well plates or 4 × 96-well plates) |
| Capillary Array | 16-capillary array |
| Excitation Source | Single 488 nm argon-ion laser |
| Detection | Dual-side illumination with grating-based full-spectrum fluorescence detection using CCD camera |
| Voltage Range | Up to 20 kV |
| Operating Temperature | 18–65 °C |
| Dimensions (W×D×H, door closed) | 74 × 54.8 × 81 cm |
| Weight | 130 kg |
| Power Requirement | 200–240 V AC, 50/60 Hz, ≤15 A, 2000 W |
| Environmental Conditions | 15–35 °C ambient, 20–80% non-condensing humidity |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730 |
| Instrument Type | First-Generation Sanger Sequencer |
| Configuration | Refurbished Unit with Full System Validation |
| Compliance | Designed to meet legacy GLP/GMP-relevant operational standards for nucleic acid analysis |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730XL |
| Category | Imported Instrument |
| Condition | Refurbished Unit |
| Sample Throughput | 96-capillary array |
| Read Length | Up to 1,000 bases (typical under standard POP-7 polymer and BigDye Terminator v3.1 chemistry) |
| Data Output Format | AB1 (.ab1), SCF, FASTA, QUAL |
| Base Calling Accuracy | ≥99.99% (Q40+ for >80% of bases in high-quality templates) |
| Run Time | ~2.5 hours per 96-well plate (standard sequencing protocol) |
| Detection System | CCD-based fluorescence detection with four-color laser excitation (488 nm, 532 nm, 595 nm, 635 nm) |
| Capillary Array | 96 × 50 cm fused-silica capillaries with polymer matrix (POP-7 or POP-6) |
| Brand | Autobio |
|---|---|
| Model | Sikun1000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVD & NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Throughput | 110M–330M Reads per Run |
| Data Output | 5–100 Gb per Run |
| Run Time | 3.5–24 h |
| Base Call Accuracy (Q30) | >85%–90% |
| Optical Detection Method | Fluorescence-Based Sequencing-by-Synthesis on Solid-Phase Amplified Flow Cell |
| Compliance | ISO 13485, IEC 62304, FDA 21 CFR Part 820, GLP/GMP-Aligned Data Integrity Framework |
| Brand | Autobio |
|---|---|
| Model | Sikun2000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVDR and NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 50–300 bp |
| Data Quality | Q30 ≥ 85%–90% |
| Accuracy | >99.9% Base Call Accuracy (per-cycle consensus) |
| Run Time | As fast as 3.2 hours (dependent on read length and chip configuration) |
| Throughput | Mid-Throughput Chip: 220 million reads (11–66 Gb) |
| High-Throughput Chip | 660 million reads (33–200 Gb) |
| Chemistry | Surface-Based Bridge Amplification with Reversible Dye-Terminator Fluorescence Detection |
| Compliance | Designed and validated per ISO 13485, IEC 62304, and aligned with FDA 21 CFR Part 820 and EU IVDR Annex I essential requirements |
| Brand | Autobio |
|---|---|
| Model | Sikun500 |
| Instrument Type | Second-Generation Sequencing Platform |
| Medical Device Classification | Class III (China NMPA) |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Q30 Score | >85–90% |
| Sequencing Accuracy | >99.9% |
| Run Time | 3.5–24 hours |
| Throughput | 60M–170M Reads per Run |
| Data Output | 5–50 Gb per Run |
| Origin | Henan, China |
| Regulatory Status | CE-IVD compliant (pending), NMPA registered |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Model | DNBSEQ-E25 |
| Instrument Type | Short-Read Sequencing Platform |
| Form Factor | Benchtop |
| Read Length Options | Single-End 100 bp (SE100), Rapid SE100 mode |
| Core Technology | DNA Nanoball (DNB) Sequencing with Patterned Flow Cell and Self-Illuminating Chemistry |
| Signal Detection | Integrated On-Chip Photodetector Array |
| Footprint | 0.1 m² |
| Power Consumption | Low-power architecture optimized for decentralized deployment |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | iSeq 100 |
| Instrument Category | Next-Generation Sequencing (NGS) Platform |
| Regulatory Status | Not a Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 2 × 150 bp |
| Throughput | Up to 4 million reads per run |
| Accuracy | ≥99.5% Q30 at 2 × 150 bp |
| Run Time | ~17 hours for 2 × 150 bp sequencing |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniSeq |
| Instrument Class | Next-Generation Sequencing (NGS) Platform |
| Medical Device Classification | Non-Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 2 × 150 bp |
| Throughput | Up to 25 Gb per run |
| Run Time | ~17–32 hours depending on workflow |
| Supported Applications | Targeted sequencing, small RNA-seq, amplicon sequencing, gene expression profiling, and microbiome analysis |
| Library Prep Compatibility | Illumina-compatible library kits (e.g., TruSight, Nextera XT, RNA Prep with Enrichment) |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Model | NextSeq 1000/1000-CN |
| Instrument Type | Short-Read Sequencing Platform (Illumina SBS Chemistry) |
| Read Length | Up to 2 × 150 bp |
| Output per Flow Cell | Up to 30 Gb (P1), 120 Gb (P2), 360 Gb (P3) |
| Q30 Score | ≥85% at 2 × 150 bp |
| Run Time | ~19–48 hours depending on read length and flow cell type |
| Flow Cell Compatibility | P1, P2, P3 (P3 limited to NextSeq 2000/2000-CN) |
| On-Instrument Secondary Analysis | Integrated DRAGEN Bio-IT FPGA Accelerator |
| Laser Wavelengths | 449 nm, 523 nm, 820 nm |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 20–80% non-condensing |
| Altitude Limit | ≤2000 m |
| Safety Classification | Class 1 Laser Product |
| Compliance | IEC 61010-1, CE, FCC/IC, NRTL certified |
| Brand | Illumina |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | NextSeq 550 |
| Instrument Class | Second-Generation (NGS) Sequencer |
| Regulatory Status | FDA-cleared IVD Device (Class II) |
| Form Factor | Benchtop Sequencing Platform |
| Integrated Functionality | NGS + Cytogenomic Microarray Scanning |
| Compliance | CE-IVD, FDA 510(k) cleared (K182913), ISO 13485 certified |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (P.R.C.-assembled) |
| Model | NovaSeq 6000 |
| Instrument Class | Next-Generation Sequencing (NGS) Platform |
| Regulatory Status | Not a Medical Device (Non-IVD) |
| Form Factor | Benchtop High-Throughput Sequencer |
| Output Capacity | Up to 6 Tb per run |
| Read Yield | Up to 20 billion reads per run |
| Run Time | 3–5 hours (for rapid kits) |
| Read Length Configurations | 2 × 50 bp, 2 × 100 bp, 2 × 150 bp, and 2 × 250 bp (paired-end) |
| Flow Cell Options | S1, S2, S4, and SP flow cells (single or dual flow cell loading) |
| Compatibility | Illumina-compatible library prep kits (e.g., TruSight, Nextera, NovaSeq Xp) |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovaSeq X |
| Instrument Category | Next-Generation Sequencing (NGS) Platform |
| Medical Device Classification | Not a Medical Device (Research-Use-Only) |
| Form Factor | Benchtop High-Throughput Sequencer |
| Read Length | 2 × 150 bp (paired-end) |
| Output per Run | Up to 8 Tb (NovaSeq X), up to 16 Tb (NovaSeq X Plus, dual flow cell) |
| Throughput per Flow Cell | Up to 26 billion single-end reads |
| Chemistry | XLEAP-SBS (eXtended LEAP – Sequencing by Synthesis) |
| Run Time | ~15–48 hours (dependent on application and read length) |
| Sample Input Capacity | Scalable from 165 Gb to 16 Tb per run |
| Integrated Bioinformatics | On-instrument DRAGEN Bio-IT Platform (supports concurrent execution of up to four secondary analysis pipelines per flow cell) |
| Data Output Format | Variant Call Format (VCF) and other standardized genomic outputs (e.g., BAM, CRAM) directly generated onboard |
| Brand | Thermo Fisher Scientific (Life Technologies) |
|---|---|
| Origin | USA |
| Model | Ion Proton™ |
| Instrument Type | Semiconductor-Based Next-Generation Sequencer |
| Form Factor | Benchtop |
| Primary Application | Whole Human Genome Sequencing, Exome Sequencing, Targeted Panels, RNA-Seq, Epigenetics (e.g., ChIP-seq, methylation analysis) |
| Regulatory Status | For Research Use Only (RUO) |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Life Technologies |
|---|---|
| Origin | USA |
| Model | SOLiD™ 5500 |
| Configuration | FlowChip-based, addressable channel architecture |
| Sequencing Chemistry | Ligation-based sequencing |
| Accuracy | Up to 99.99% per base (with ECC error correction) |
| Multiplexing Capacity | Up to 96 barcodes per run |
| Software Platform | SOLiD™ System Software Suite v4.x |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11 audit trail requirements (when deployed with validated IT infrastructure) |
| Brand | LIVOBOT |
|---|---|
| Model | EosBot Seq24 |
| Origin | Beijing, China |
| Instrument Type | Integrated Library Prep Platform (Not a DNA Sequencer) |
| Throughput | 8–24 samples per run |
| Regulatory Status | Not a medical device |
| Automation Level | Fully automated, walk-away library construction |
| Compliance | Designed for GLP-compliant laboratories |
| Software Communication | TCP/IP Socket protocol |
| Dimensions | 850 × 1200 × 1050 mm |
| Weight | 260 ± 5 kg |
| Power Supply | AC 100–240 V, 180 VA |
| Operating Environment | 20–30 °C, 20–80% RH (non-condensing), 80–106 kPa |
| Liquid Handling | Single-channel and 8-channel fixed-pitch pipettors (2–500 µL) |
| Positioning Accuracy | ±0.05 mm repeatability |
| Thermal Modules | PCR block (4–100 °C, automated heated lid), incubation (RT +5 to 70 °C), refrigeration (4 ±1 °C) |
| Air Quality Control | HEPA filtration + UV sterilization |
| Safety | Meets Class II biological safety cabinet performance criteria |
| Compatible Platforms | Illumina, MGI/BGI, Thermo Fisher Ion Torrent (via adapter-compatible protocols) |
| Compatible Kits | QIAGEN, Vazyme, TIANGEN, Yeasen, Phalanx, Kangweiji, Abbkine, and other major commercial NGS library prep kits |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Second-Generation Sequencer |
| Platform | DNBSEQ™ Technology |
| Form Factor | Benchtop |
| Regulatory Status | Medical Device |
| Read Lengths | SE100, PE50, PE150, PE300, SE400 |
| Throughput per Run | 8–96 Gb |
| Q30 Score | >85% (PE150) |
| Run Time | 12 h (PE150) |
| Compliance | CE-IVDR, NMPA Class II/III registered (as applicable), supports 21 CFR Part 11-compliant software modules |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MGISEQ-T7 |
| Instrument Type | Second-Generation Sequencer |
| Medical Device Classification | Yes (Class II/III per NMPA) |
| Throughput | 1–6 Tb per run |
| Read Lengths | SE50, PE100, PE150 |
| Accuracy | Q30 ≥ 85% (PE100), ≥ 80% (PE150) |
| Run Time | ~20 h (PE100), ~24 h (PE150), ~5 h (SE50) |
| Maximum Effective Reads per Flow Cell | 5,000 M |
| Flow Cells per Run | 1–4 (independently controlled) |
| Data Output per Flow Cell | up to 1.5 Tb |
| Daily Max Output | 6 Tb (4-flow-cell mode) |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Sciclone G3 NGSx iQ |
| Instrument Type | Next-Generation Sequencing (NGS) Library Preparation Automation Platform |
| Regulatory Classification | Non-Medical Device |
| Form Factor | Benchtop Automation System |
| Compatibility | Vendor-Neutral NGS Library Prep Kits (Illumina®, Thermo Fisher™, IDT®, Takara Bio®, etc.) |
| Certified Validation | PKI-Validated Protocol Suite |
| Integrated Thermal Cycler | Inheco ODTC Desktop Dry Block Thermocycler |
| Robotic Arm | Twister III 5-Axis Articulated Robot |
| Liquid Handling | Dual-Channel (Sciclone G3 NGSx) + Optional 384-Channel Head (NGSx iQ HT Variant) |
| Tip Storage | 27-Position Tip Rack Carousel |
| User Interface | Graphical Touchscreen with Workflow Visualization |
| Automation Level | Unattended End-to-End DNA-to-Library Processing |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | Thermo Fisher 3500xL Genetic Analyzer |
| Pricing | Available upon Request |
| Capillary Count | 24 |
| Laser Wavelength | 505 nm (solid-state, single-line) |
| Capillary Length | 36 cm / 50 cm |
| Electrical Requirement | 15 A, 220–240 V AC |
| Operating System | Windows 7 SP1 |
| Software | 3500 Series Data Collection Software |
| RFID-Enabled Consumables | Yes |
| Dye Capacity | Up to 6 fluorescent dyes |
| Polymer Compatibility | POP-4™, POP-6™, POP-7™ |
| Throughput | Up to 1,104 samples/day (ShortReadSeqPOP7 module) |
| Weight | 82 kg |
| Warranty | 1-year limited warranty covering parts, labor, installation, and application training |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ABI 3130 |
| Instrument Type | Capillary Electrophoresis-Based DNA Sequencer |
| Sample Format | 96-well or 384-well plates |
| Detection Method | Laser-Induced Fluorescence (LIF) with CCD imaging |
| Separation Chemistry | POP-7 polymer |
| Excitation Source | Solid-state 488 nm and 532 nm lasers |
| Data Output | .fsa, .ab1, .txt |
| Software Platform | Data Collection v3.0 / Sequence Analysis v5.4 / GeneMapper v4.1 |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Calibration Standard | Internal size standards (e.g., GS500-LIZ, ROX) |
| Run Time | ~45–60 min per 96-capillary run (standard sequencing protocol) |
| Read Length | Up to 800–1000 bases (Sanger sequencing, depending on template quality and chemistry) |
| Throughput | 384 samples per 24-hour period (with automated plate handling and dual-injection capability) |
| Accuracy | ≥99.99% base call accuracy under optimal conditions (per manufacturer specifications for Sanger chemistry) |
| Reproducibility | CV < 2% for fragment sizing across runs (validated with STR and SNP panels) |
| Resolution | ≤1 bp for fragments 50–500 bp (using GS500-LIZ standard) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3500 Dx / 3500xL Dx |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Throughput | 1104 samples/day |
| Read Length Range | 30–1000 bp |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Run Time | 1000 reads per 120 min |
| Data Format | Capillary Electrophoresis-Based Sequencing |
| Software | Data Collection Software v3, Sequencing Analysis v6, KB Basecaller v1.4.1, Variant Reporter™, SeqScape®, GeneMapper®, GeneMapper ID-x®, MicroSEQ ID® |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 3500 / 3500xL |
| Instrument Type | First-Generation Sanger Sequencer |
| Throughput | 368 samples/day |
| Read Length | 1000 bp |
| Accuracy | 99.99% |
| Reproducibility | 90% |
| Run Time | 1000 bp per 125 min |
| Capillary Configuration | 8-capillary (3500) or 24-capillary (3500xL), field-upgradeable |
| Laser Source | 505 nm solid-state, air-cooled |
| Temperature Control Range | 18–70 °C |
| Electrophoresis Voltage | up to 20 kV |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SeqStudio 24 Flex |
| Price | Upon Request |
| Capillary Length | 36 cm or 50 cm |
| Sample Format | 96-well plates, 384-well plates, or 8-tube strips |
| Polymer Compatibility | POP-4™, POP-6™, POP-7™ |
| Operating Temperature Range | 15–30°C (59–86°F), ≤80% RH (non-condensing), ±2°C stability required during operation |
| Oven Temperature Control Range | 18–70°C |
| Electrophoresis Voltage | Up to 20 kV |
| Dimensions (W×D×H) | 70 × 67.5 × 86.5 cm (27.6 × 26.6 × 34.1 in) |
| Weight | 115 kg (253.5 lbs) |
| Power Requirement | 100–240 VAC ±10%, 50/60 Hz |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Import |
| Model | SeqStudio |
| Instrument Category | First-Generation (Sanger) Sequencer |
| Read Length | 800 bp |
| Throughput | 192 samples/day |
| Base Call Accuracy | 90% |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Run Time | 35 min |
| Data Output Format | Capillary Electrophoresis-Based Sequencing Traces |
| Software Suite | Sequencing Analysis Software, SeqScape™, Variant Reporter™, GeneMapper™, Minor Variant Finder (MVF) |